Bharat Sanchar Nigam Limited Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Bharat Sanchar Nigam Limited - BSNL Tender
Electrical Goods and Equipments
Electrical and Electronics
GEM
Opening Date20 Jul 2023
Closing Date10 Aug 2023
Tender Amount₹ 1,97,11,931
Costs
EMD
₹ 3,94,239Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Supply Of 7 Tr Hpac,itc Of 7 Tr Hpac,drain Pipe 40mm,ms Cable Tray 150 Mm,ms Cable Tray 300 Mm,sf X CATEGORY: Supply of 7 TR HPAC , ITC of 7 TR HPAC , Drain pipe 40mm , MS cable tray 150 mm , MS cable tray 300 mm , SF XLPE 1.1 KV CABLE , SF REFRIGERENT PIPE , CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2023/B/3718313Bid Award Id
ViewTender No
GEM/2023/B/3718313Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
atcpaclko_2023-07-20-11-20-55_ffa23d91e294925be9483a4c292da520.pdf
boq_item_hpac_lkoca_2023-07-20-11-20-55_c2b9b526b5a035036d2396dfda90ed5b.csv
BOQ Items
... More
MS cable tray 150 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.150 mm wide x 50 mm deepx1.6 mm thickness
16
-
-
... More
MS cable tray 300 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.300 mm wide x 50 mm deepx1.6 mm thickness.
16
-
-
... More
SF XLPE 1.1 KV CABLE , Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I, 1964 of 4 X 2.5 sq. mm on the existing MS tray for interconnection between the outdoor and indoor units beyond 10 Meters etc comp.as required.
40
-
-
... More
SF REFRIGERENT PIPE , S/F Suitable size copper refrigerant piping interconnection between the outdoor and indoor units as per manufacturers specifications beyond 10 Meters on the existing MS tray etc comp. as required.Only one circuit shall be measured for hot and liquid line.
16
-
-
... More
CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, a. During first year of operation after warranty period.
4
-
-
... More
CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, b. During 2nd year of operationof after warranty period
4
-
-
... More
CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following c. During 3rd year of operation after warranty period.
4
-
-
... More
Supply of 7 TR HPAC , Supply of microprocessor based air cooled type super low noise 7 TR ,sensible cooling capacity Top or bottom discharge type as per requirement Precision Air conditioning unit working on R407C/R410A refrigerant and capable of delivering minimum 3850 CFM comprising of indoor and outdoor units as detailed below with all components, controls, provided with BMS connectivity and interlocking, electrical accessories, refrigerant piping including sequential control and Run hour equalization etc., as per detailed specifications attached. Note 1. Initial charging of oil and refrigerant as required.
2. Filter to be provided on the package unit having 95 percentage efficiency down to 5 microns.
3. Serrated rubber pads for the unit and the condenser as required.
2
-
-
... More
ITC of 7 TR HPAC , Installation, testing and commissioning of the above package AC unit and condensers including providing powder coated MS stand for Indoor unit and corrosion treated and painted frame for condensers, along with supplying and laying of suitable size refrigerant piping for interconnection of indoor and outdoor unit , 4 core 2.5sqmm armoured copper conductor cable, 25mmX5mm GI earth strip between indoor and outdoor unit, suitable perforated MS cable tray , 40 mm dia class B GI drain pipe up to 10 meters, minor civil works like cutting / making openings in walls, floors, ceilings, making good the damages, providing necessary scaffolding, pressure testing, vaccumising, gas charging etc. complete as required.
2
-
-
... More
Drain pipe 40mm , Providing plumbing work for drainage requirements i/c supply of class B GI pipe with all accessories for drain water outlet beyond 10 Meters length including painting etc., as required. ISI marked Tata/Jindal 40mm GI pipe ,Medium Class.
8
-
-
... More
MS cable tray 150 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.150 mm wide x 50 mm deepx1.6 mm thickness
8
-
-
... More
MS cable tray 300 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.300 mm wide x 50 mm deepx1.6 mm thickness.
8
-
-
... More
SF XLPE 1.1 KV CABLE , Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I, 1964 of 4 X 2.5 sq. mm on the existing MS tray for interconnection between the outdoor and indoor units beyond 10 Meters etc comp.as required.
20
-
-
... More
SF REFRIGERENT PIPE , S/F Suitable size copper refrigerant piping interconnection between the outdoor and indoor units as per manufacturers specifications beyond 10 Meters on the existing MS tray etc comp. as required.Only one circuit shall be measured for hot and liquid line.
8
-
-
... More
CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, a. During first year of operation after warranty period.
2
-
-
... More
CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, b. During 2nd year of operationof after warranty period
2
-
-
... More
CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following c. During 3rd year of operation after warranty period.
2
-
-
... More
Supply of 7 TR HPAC , Supply of microprocessor based air cooled type super low noise 7 TR ,sensible cooling capacity Top or bottom discharge type as per requirement Precision Air conditioning unit working on R407C/R410A refrigerant and capable of delivering minimum 3850 CFM comprising of indoor and outdoor units as detailed below with all components, controls, provided with BMS connectivity and interlocking, electrical accessories, refrigerant piping including sequential control and Run hour equalization etc., as per detailed specifications attached. Note 1. Initial charging of oil and refrigerant as required.
2. Filter to be provided on the package unit having 95 percentage efficiency down to 5 microns.
3. Serrated rubber pads for the unit and the condenser as required.
3
-
-
... More
ITC of 7 TR HPAC , Installation, testing and commissioning of the above package AC unit and condensers including providing powder coated MS stand for Indoor unit and corrosion treated and painted frame for condensers, along with supplying and laying of suitable size refrigerant piping for interconnection of indoor and outdoor unit , 4 core 2.5sqmm armoured copper conductor cable, 25mmX5mm GI earth strip between indoor and outdoor unit, suitable perforated MS cable tray , 40 mm dia class B GI drain pipe up to 10 meters, minor civil works like cutting / making openings in walls, floors, ceilings, making good the damages, providing necessary scaffolding, pressure testing, vaccumising, gas charging etc. complete as required.
3
-
-
... More
Drain pipe 40mm , Providing plumbing work for drainage requirements i/c supply of class B GI pipe with all accessories for drain water outlet beyond 10 Meters length including painting etc., as required. ISI marked Tata/Jindal 40mm GI pipe ,Medium Class.
12
-
-
... More
MS cable tray 150 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.150 mm wide x 50 mm deepx1.6 mm thickness
12
-
-
... More
MS cable tray 300 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.300 mm wide x 50 mm deepx1.6 mm thickness.
12
-
-
... More
SF XLPE 1.1 KV CABLE , Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I, 1964 of 4 X 2.5 sq. mm on the existing MS tray for interconnection between the outdoor and indoor units beyond 10 Meters etc comp.as required.
30
-
-
... More
SF REFRIGERENT PIPE , S/F Suitable size copper refrigerant piping interconnection between the outdoor and indoor units as per manufacturers specifications beyond 10 Meters on the existing MS tray etc comp. as required.Only one circuit shall be measured for hot and liquid line.
12
-
-
... More
CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, a. During first year of operation after warranty period.
3
-
-
... More
CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, b. During 2nd year of operationof after warranty period
3
-
-
... More
CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following c. During 3rd year of operation after warranty period.
3
-
-
... More
Supply of 7 TR HPAC , Supply of microprocessor based air cooled type super low noise 7 TR ,sensible cooling capacity Top or bottom discharge type as per requirement Precision Air conditioning unit working on R407C/R410A refrigerant and capable of delivering minimum 3850 CFM comprising of indoor and outdoor units as detailed below with all components, controls, provided with BMS connectivity and interlocking, electrical accessories, refrigerant piping including sequential control and Run hour equalization etc., as per detailed specifications attached. Note 1. Initial charging of oil and refrigerant as required.
2. Filter to be provided on the package unit having 95 percentage efficiency down to 5 microns.
3. Serrated rubber pads for the unit and the condenser as required.
3
-
-
... More
ITC of 7 TR HPAC , Installation, testing and commissioning of the above package AC unit and condensers including providing powder coated MS stand for Indoor unit and corrosion treated and painted frame for condensers, along with supplying and laying of suitable size refrigerant piping for interconnection of indoor and outdoor unit , 4 core 2.5sqmm armoured copper conductor cable, 25mmX5mm GI earth strip between indoor and outdoor unit, suitable perforated MS cable tray , 40 mm dia class B GI drain pipe up to 10 meters, minor civil works like cutting / making openings in walls, floors, ceilings, making good the damages, providing necessary scaffolding, pressure testing, vaccumising, gas charging etc. complete as required.
3
-
-
... More
Drain pipe 40mm , Providing plumbing work for drainage requirements i/c supply of class B GI pipe with all accessories for drain water outlet beyond 10 Meters length including painting etc., as required. ISI marked Tata/Jindal 40mm GI pipe ,Medium Class.
12
-
-
... More
MS cable tray 150 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.150 mm wide x 50 mm deepx1.6 mm thickness
12
-
-
... More
MS cable tray 300 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.300 mm wide x 50 mm deepx1.6 mm thickness.
12
-
-
... More
SF XLPE 1.1 KV CABLE , Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I, 1964 of 4 X 2.5 sq. mm on the existing MS tray for interconnection between the outdoor and indoor units beyond 10 Meters etc comp.as required.
30
-
-
... More
SF REFRIGERENT PIPE , S/F Suitable size copper refrigerant piping interconnection between the outdoor and indoor units as per manufacturers specifications beyond 10 Meters on the existing MS tray etc comp. as required.Only one circuit shall be measured for hot and liquid line.
12
-
-
... More
CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, a. During first year of operation after warranty period.
3
-
-
... More
CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, b. During 2nd year of operationof after warranty period
3
-
-
... More
CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following c. During 3rd year of operation after warranty period.
3
-
-
... More
Supply of 7 TR HPAC , Supply of microprocessor based air cooled type super low noise 7 TR ,sensible cooling capacity Top or bottom discharge type as per requirement Precision Air conditioning unit working on R407C/R410A refrigerant and capable of delivering minimum 3850 CFM comprising of indoor and outdoor units as detailed below with all components, controls, provided with BMS connectivity and interlocking, electrical accessories, refrigerant piping including sequential control and Run hour equalization etc., as per detailed specifications attached. Note 1. Initial charging of oil and refrigerant as required.
2. Filter to be provided on the package unit having 95 percentage efficiency down to 5 microns.
3. Serrated rubber pads for the unit and the condenser as required.
3
-
-
... More
ITC of 7 TR HPAC , Installation, testing and commissioning of the above package AC unit and condensers including providing powder coated MS stand for Indoor unit and corrosion treated and painted frame for condensers, along with supplying and laying of suitable size refrigerant piping for interconnection of indoor and outdoor unit , 4 core 2.5sqmm armoured copper conductor cable, 25mmX5mm GI earth strip between indoor and outdoor unit, suitable perforated MS cable tray , 40 mm dia class B GI drain pipe up to 10 meters, minor civil works like cutting / making openings in walls, floors, ceilings, making good the damages, providing necessary scaffolding, pressure testing, vaccumising, gas charging etc. complete as required.
3
-
-
... More
Drain pipe 40mm , Providing plumbing work for drainage requirements i/c supply of class B GI pipe with all accessories for drain water outlet beyond 10 Meters length including painting etc., as required. ISI marked Tata/Jindal 40mm GI pipe ,Medium Class.
12
-
-
... More
MS cable tray 150 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.150 mm wide x 50 mm deepx1.6 mm thickness
12
-
-
... More
MS cable tray 300 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.300 mm wide x 50 mm deepx1.6 mm thickness.
12
-
-
... More
SF XLPE 1.1 KV CABLE , Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I, 1964 of 4 X 2.5 sq. mm on the existing MS tray for interconnection between the outdoor and indoor units beyond 10 Meters etc comp.as required.
30
-
-
... More
SF REFRIGERENT PIPE , S/F Suitable size copper refrigerant piping interconnection between the outdoor and indoor units as per manufacturers specifications beyond 10 Meters on the existing MS tray etc comp. as required.Only one circuit shall be measured for hot and liquid line.
12
-
-
... More
CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, a. During first year of operation after warranty period.
3
-
-
... More
CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, b. During 2nd year of operationof after warranty period
3
-
-
... More
CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following c. During 3rd year of operation after warranty period.
3
-
-
... More
Supply of 7 TR HPAC , Supply of microprocessor based air cooled type super low noise 7 TR ,sensible cooling capacity Top or bottom discharge type as per requirement Precision Air conditioning unit working on R407C/R410A refrigerant and capable of delivering minimum 3850 CFM comprising of indoor and outdoor units as detailed below with all components, controls, provided with BMS connectivity and interlocking, electrical accessories, refrigerant piping including sequential control and Run hour equalization etc., as per detailed specifications attached. Note 1. Initial charging of oil and refrigerant as required.
2. Filter to be provided on the package unit having 95 percentage efficiency down to 5 microns.
3. Serrated rubber pads for the unit and the condenser as required.
6
-
-
... More
ITC of 7 TR HPAC , Installation, testing and commissioning of the above package AC unit and condensers including providing powder coated MS stand for Indoor unit and corrosion treated and painted frame for condensers, along with supplying and laying of suitable size refrigerant piping for interconnection of indoor and outdoor unit , 4 core 2.5sqmm armoured copper conductor cable, 25mmX5mm GI earth strip between indoor and outdoor unit, suitable perforated MS cable tray , 40 mm dia class B GI drain pipe up to 10 meters, minor civil works like cutting / making openings in walls, floors, ceilings, making good the damages, providing necessary scaffolding, pressure testing, vaccumising, gas charging etc. complete as required.
6
-
-
... More
Drain pipe 40mm , Providing plumbing work for drainage requirements i/c supply of class B GI pipe with all accessories for drain water outlet beyond 10 Meters length including painting etc., as required. ISI marked Tata/Jindal 40mm GI pipe ,Medium Class.
24
-
-
... More
MS cable tray 150 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.150 mm wide x 50 mm deepx1.6 mm thickness
24
-
-
... More
MS cable tray 300 mm , Fabrication and installing following size of perforated M.S. cable tray alongwith 25mmX5mm GI earth strip i/c horizontal and vertical bends , reducers, tees cross members and other accessories as required and duly suspended from the ceiling with MS suspenders i/c painting etc as reqd, beyond 10 Meters length.300 mm wide x 50 mm deepx1.6 mm thickness.
24
-
-
... More
SF XLPE 1.1 KV CABLE , Supplying and laying of 1.1 KV grade, XLPE insulated, armoured and sheathed copper conductor cables confirming to IS 1554 Part I, 1964 of 4 X 2.5 sq. mm on the existing MS tray for interconnection between the outdoor and indoor units beyond 10 Meters etc comp.as required.
60
-
-
... More
SF REFRIGERENT PIPE , S/F Suitable size copper refrigerant piping interconnection between the outdoor and indoor units as per manufacturers specifications beyond 10 Meters on the existing MS tray etc comp. as required.Only one circuit shall be measured for hot and liquid line.
24
-
-
... More
CAMC FOR FIRST YEAR AFTER EXPIRY OF WARANTEE PERIOD , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, a. During first year of operation after warranty period.
6
-
-
... More
CAMC FOR SECOND YEAR AFTER EXPIRY FIRST YEAR CAMC , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following, b. During 2nd year of operationof after warranty period
6
-
-
... More
CAMC FOR THIRD YEAR AFTER EXPIRY OF CAMC OF SECOND YEAR , Comprehensive maintenance of 7TR. HPAC PKG. units which include routine preventive and breakdown maintenance for a period of 3 years including supply of refrigerant gas and other consumables, repair/ replacement of worn out items with minimum down time and warranty/ guarantee of repaired/ replaced items after completion of one year of guarantee period. Rates to be quoted year wise as per following c. During 3rd year of operation after warranty period.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements