Assam Power Distribution Company Limited Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Assam Power Distribution Company Limited - APDCL Tender
Eprocure
Opening Date5 Sep 2018
Closing Date12 Sep 2018
Tender Amount₹ 29,35,13,792 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 29,35,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Tender for Rural Electrification works.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_APDCL_8461_1Bid Award Id
ViewTender No
APDCL/SAUBHAGYA/VEI/ 2018_19/02/DMH_SAU_01Tender Authority
Assam Power Distribution Company Limited ViewPurchaser Address
-Website
http://https://www.apdcl.org
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
GI Barbed Wire for anticlimbing device (12 SWG=2.5mm)
-
-
-
Danger Plate 11KV
-
-
-
Galvanized pre-fabricated steel materials like T Cross arm, channel cross arm, angle, flats and all other GI materials shown in BOQ for over head structures as per technical specification, approved drawings and scope of work.
-
-
-
G I Channel Section 75x40x6x1100 mm and GI top cleat 75x40x6x350 mm for fixing of 11 KV polymeric Pin insulator
-
-
-
Galvanized Channel Cross Arm (75x40x6X2200) mm
-
-
-
GI Angle (40x40x6 mm) as tie for GI Channel Cross Arm
-
-
-
Jam Clamp of GI Flat (50x6 mm)
-
-
-
Galvanized Steel Nuts, Bolts with Washers (Assorted) as per technical specification, approved drawings and scope of work.
-
-
-
Galvanized Stay set with 50x8 mm Stay clamp, HT stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/10 swg GI stranded wire etc as required as per technical specification, approved drawings and scope of work.
-
-
-
Stay set (HT)
-
-
-
Guy Insulator (HT)
-
-
-
GI Stay wire 7/10 SWG
-
-
-
Insulators with mounting hardware, fittings as per technical specification, approved drawings and scope of work.
-
-
-
Composite Polymeric 11 kV Disc Insulator (70 KN) with Hardware fittings
-
-
-
Composite Polymeric 11 kV Pin Insulator
-
-
-
Earthing
-
-
-
CI Earth Pipe 1.8 Mtr. long, 100 mm dia as per TS.
-
-
-
GI wire 6 SWG for Earthing
-
-
-
ACSR Rabbit coductor alongwith Supply of items for erection of ACSR Rabbit Conductor with Jointing sleeves, binding materials, PG clamps, Tension Clamps, bi-metallic clamp etc. for overhead line and jumpers as required as per technical specification, approved drawings and scope of work. (6/1/3.35mm, 50 Sqmm)
-
-
-
Tension Clamp for Rabbit
-
-
-
ACSR Rabbit Conductor 6/1/3.35mm, 50 Sqmm
-
-
-
Jointing Sleeve for Rabbit
-
-
-
PG Clamp for Rabbit
-
-
-
AI. Binding Wire (10 SWG.)
153
-
-
Line Crossing - Line to line / Road: Protective guarding as per REC construction standard, to be provided at locations where 11KV/33 KV line is crossing road, 11 KV line is crossing LT Lines/ P&T lines etc. Supplying 2 Nos guarding GI angle cross arm (50x50x6x2500mm), 2 Nos Y- guy with 7/3.14 mm wire, 2 Nos 16 mm diameter Eye-bolts, 2 Nos earthing of 100mm dia CI earth pipe of 1.8 meter long, 6 SWG GI wires for earthing connection, 6 SWG wire for guard wire, 8 SWG wire for cross lacing.
-
-
-
Galvanized Angle Cross Arm (50x50x6X2500) mm for Guarding
-
-
-
GI wire 8 SWG for cross lacing as per T.S
-
-
-
GI wire 6 SWG for Earthing & Guarding
-
-
-
GI 'I' Hook
-
-
-
CI Earth Pipe 1.8 Mtr. long, 100 mm dia as per TS.
-
-
-
11 kV Drop Out fuse units (set of 3 units) 150 Amp, 3-ph, along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings [For tapping points]
-
-
-
11 KV DO Fuse 150A (Set of three)
-
-
-
Composite Polymeric 11 kV Pin Insulator
-
-
-
Galvanized Channel Cross Arm (75x40x6X2200) mm
-
-
-
Galvanized Channel Cross Arm (100x50x6X2200) mm
-
-
-
GI Nuts & Bolts with GI washer (Assorted)
-
-
-
Pole Clamp of GI flat (50x6) mm
-
-
-
PG Clamp for Rabbit
-
-
-
GI wire 6 SWG for Earthing
-
-
-
CI Earth Pipe 1.8 Mtr. long, 100 mm dia as per TS.
-
-
-
Distribution Transformer Substations
-
-
-
DTR Substation Supports as per technical specification, approved drawings and scope of work.
-
-
-
10 meter long MS Steel Tubular poles 410 MPa, 241Kg. weight with welded steel base plate of SP-56 as per IS and approved GTP .
-
-
-
Danger Plate HT (1.60 mm thick)
-
-
-
GI Barbed Wire for anticlimbing device (12 SWG=2.5mm)
-
-
-
Galvanized pre-fabricated steel materials like channel cross arm, angle, flats for over head structures as per technical specification, approved drawings and scope of work and BOQ
-
-
-
GI Channel Cross Arm (100x50x6X2200)mm
-
-
-
GI Angle (50x50x6x500)mm
-
-
-
Jam Clamp of GI Flat (50x6 mm)
-
-
-
Pole Clamp of GI flat (50x6)mm
-
-
-
Galvanized Steel Nuts, Bolts with Washers (Assorted) as per technical specification, approved drawings and scope of work.
-
-
-
Insulators with hardware fittings, hardware etc as required as per technical specification, approved drawings and scope of work.
-
-
-
Composite Polymeric 11 kV Disc Insulator (70 KN) with Hardware fittings
-
-
-
Composite Polymeric 11 kV Pin Insulator
-
-
-
Level II (equivalent to 4 star category) designated Distrbution Transformer of 3 phase Aluminium wound, manufactured by BIS certiified company including Goat Proof fencing, Sign Board, Danger Plate etc for the DTR substation as per TS .
-
-
-
DTR 11/0.433 KV, 25 KVA, level II (equivalent to 4 star category) BIS Certified
-
-
-
DTR 11/0.433 KV, 63 KVA, level II (equivalent to 4 star category) BIS Certified
-
-
-
Goat Proof Security GI Fencing along with Sign Board for DTR as per TS
-
-
-
Outdoor mounting type weather proof with degree of protection with suitable earthing, front door operated with proper locking arrangement, lugs, mounting channel frame, hardware as per scope of the work, technical specifications and approved drawings suitable for following transformer:
-
-
-
Rewirable Main Switch TPN (3Ph-4w),100 A (Outdoor type water proof) for 25 KVA DTR
-
-
-
Rewirable Main Switch TPN (3Ph-4w),200 A (Outdoor type water proof) for 63 KVA DTR
-
-
-
12 KV, 9KA Lightening Arrester Distribution Class for DTR as per technical specification, approved drawings and scope of work. (Set of Three)
-
-
-
Gang Operated AB Switch 11 kV, 400A, 3-ph, 3 Pin type, Vertical Mounting type, along with Support Insulators, Channels, Pole Clamps, CI Earth Pipes, earth wire, GI Nuts and Bolts, PG Clamp, Base Channel down Pipe, Arcing Horns etc. complete as per technical specifications, scope of works and approved drawings
-
-
-
11 KV Gang operated switch 400 A
-
-
-
GI Channel Cross Arm (100x50x6X2200)mm
-
-
-
Pole Clamp of GI flat (50x6)mm
-
-
-
CI Earth Pipe 1.8 Mtr. long, 100 mm dia as per TS.
-
-
-
GI wire 6 SWG for Earthing
-
-
-
GI Nuts & Bolts with GI washer (Assorted)
-
-
-
PG Clamp for Rabbit
-
-
-
I Hook GI
-
-
-
GI Channel Section (100x50x6X500)mm
-
-
-
11 kV Drop Out fuse units (set of 3 units) 150 Amp, 3-ph, along with Support Insulators, Base Channel, fuse barrel etc. complete as per technical specifications, scope of works and approved drawings
-
-
-
Pipe earthing using 100 mm dia CI earth pipe 1800 mm long (5 nos. per DTR), as per IS 1161 and as per REC construction drawings, connecting risers to various equipment using GS Stranded wires/GI 6 SWG wire as per scope of work of Distribution Transformer Substations, approved drawings and technical specifications.
-
-
-
CI Earth Pipe 1.8 Mtr. long, 100 mm dia as per TS.
-
-
-
GI wire 6 SWG for Earthing
-
-
-
PVC Cable (Stranded, unarmoured cable) bi-metallic connector for connection of transformer LV bushing to Outgoing line through metering cabinet and Main Switch as per Scope of work, technical specification and approved drawings
-
-
-
PVC Cable 1-Core 50 sq. mm (Aluminium) for 25 KVA DTR
-
-
-
XLPE Cable 1.1 KV 1-Core 95 sq. mm unarmoured (Aluminium)
-
-
-
Bi-metallic Lug (assorted)
-
-
-
ACSR Rabbit Conductor 6/1/3.35mm, 50 Sqmm, (15 mtr) alongwith Materials required for erection of ACSR Rabbit Conductor 6/1/3.35mm, 50 Sqmm for jumpering including PG Clamps, Tension Clamp, bi-metallic connectors, hardware etc as per technical specifications, approved drawings and scope of works.
-
-
-
Tension Clamp for Rabbit
-
-
-
ACSR Rabbit Conductor 6/1/3.35mm, 50 Sqmm
-
-
-
PG Clamp for Rabbit
-
-
-
Metering Cabinet made of MS sheet of thickness not less than 1.6 mm CRCA sheet by deep drawn method, dust and moisture vermin, weather proof with degree of protection front door operated with proper locking arrangement which shall house suitable bus bars, earthing bus, earthing terminals, box illumination, , lugs, mounting channel frame, internal wiring with FRLS stranded copper cables of reputed make including outdoor mounting type LTCT (100/5 Amp for 25 KVA DTR and 100/5 AMp for 63 KVA DTR, Accuracy Class 0.5, 4 Nos. from APDCL approved vendor) danger plate, numbering, back clamps, hardware, pilferproof with LT 3 - Ph CT Operated AC Static Trivector Meter; Accuracy Class 0.5( from APDCL approved vendor)with provision of downloading data. as per TS
-
-
-
LT 3 - Ph CT Operated AC Static Trivector Meter; Accuracy Class 0.5 with Water proof Metering Cabinet.
-
-
-
LT CT 100/5 Amp, Accuracy Class 0.5
-
-
-
New LT Line
-
-
-
Support for LT overhead Line as per technical specification, approved drawings and scope of work.
-
-
-
MS Steel Tubular Pole SP-22 duly painted (8.5 Mtr length 141 Kg. weight) 410 MPa as per T.S.
-
-
-
LT Danger Plate (1.60 mm thick)
-
-
-
Galvanised Stay Set with 50x8 mm stay clamp, LT stay guy insulator, nut bolts, 2 Nos turn buckles, 1.8 m long, 16 mm diameter solid GS Stay rod & 7/3.15 mm GI stranded wire etc. as required.
-
-
-
LT Stay set
-
-
-
LT Guy Insulator
-
-
-
GI Stay wire 7/3.15 mm
-
-
-
Earthing as per approved drawings, technical specifications and scope of work
-
-
-
CI Earth Pipe 1.8 Mtr. long, 100 mm dia as per TS.
-
-
-
6 SWG GI wire for earthing & GI nuts, bolts & washers
-
-
-
AERIAL BUNCHED XLPE CABLE 1.1 KV XLPE 3Cx50 sqmm + 1Cx35 sqmm (Insulated messenger cum neutral) alongwith items required for erection of AB cable shown in BOQ for AB Cable 3-Ph. (Cable length =1.1xCkt. Km.)
-
-
-
CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (3C x 50 sqmm + 1Cx35 sqmm)
-
-
-
Plastic Tie of required size for tieing the AB Cables.
-
-
-
GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for MS Steel Tubular Pole SP-22
-
-
-
GI I-Hook
-
-
-
Anchore Clamp Wedge Type LT ABC as per NFC Standard
-
-
-
Suspension Clamp ABC as per NFC Standard
-
-
-
Cable end caps for ABC cables
-
-
-
ASA Distribution box for 140 A, 3-PH (for 6 connections) with spring loaded Busbar System.
-
-
-
Steel Strap for installing DB (Size: 20 mm x 1 mtr long)
-
-
-
Buckles for Steel Straps for DB fixing
-
-
-
Insulating Piercing Connector IPC EP50 for DB Charging as per NFC Std.
-
-
-
Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std.
-
-
-
Insulated crimping type midspan joint (for phase & neutral) as per NFC Std.
-
-
-
10 sq. mm Al. PVC Cable per Distribution Box
-
-
-
Galvanized Channel (100x50x6X2200) mm for height rising
-
-
-
AERIAL BUNCHED XLPE CABLE 1.1 KV XLPE 1Cx35 sqmm +1X25 sqmm (Insulated messenger cum neutral) alongwith items required for erection of AB cable shown in BOQ for AB Cable 1-Ph.(Cable length =1.1xCkt. Km.)
-
-
-
CABLE ABC 1.1 KV XLPE with Insulated Messenger cum Neutral (1C x 35 sqmm + 1Cx25 sqmm)
-
-
-
Plastic Tie of required size for tieing the AB Cables.
-
-
-
GI Pole Clamp with GI Nuts - Bolts & GI Washer (Size: 50x6mm) for MS Steel Tubular Pole SP-22
-
-
-
GI I-Hook
-
-
-
Anchore Clamp Wedge Type LT ABC as per NFC Standard
-
-
-
Suspension Clamp ABC as per NFC Standard
-
-
-
Cable end caps for ABC cables
-
-
-
ASA Distribution box for 140 A, 1-PH (for 6 connections) with spring loaded Busbar System.
-
-
-
Steel Strap for installing DB (Size: 20 mm x 1 mtr long)
-
-
-
Buckles for Steel Straps for DB fixing
-
-
-
Insulating Piercing Connector IPC EP35 for DB Charging as per NFC Std.
-
-
-
Insulating Piercing Connector IPC EP25 for DB Charging as per NFC Std.
-
-
-
Insulated crimping type midspan joint (for phase & neutral) as per NFC Std.
-
-
-
10 sq. mm Al. PVC Cable per Distribution Box
-
-
-
Galvanized Channel (100x50x6X2200) mm for height rising
-
-
-
New Service Connections to Beneficiaries
-
-
-
LT Single Phase Service connection:
Single phase service connection using Thermo-plastic/PVC insulated cable of size 2 Core 4.0 sqmm aluminium conductor (up to 35m length of house hold from LT line), 10 SWG GI tension wire, 25x3000 mm GI Pipe medium class to accept service cable at consumer residence, a meter board (350x200x40 mm), 1-ph energy meter single phase (5-30A) fully static class-1 energy meter, service board (200x150x40 mm), 2 nos. single piano type ISI marked 240V/5A switch, 1 no. 240V/5A socket of ISI marked, 240V/5A ISI marked holder, 144-288V; up to 9 Watts; 710 lumen LED lamp, 240V, 5A capacity ISI marked lamp holder, Internal wiring using 1.5 sqmm copper multistrands PVC insulated ISI marked cable, 240V/16A double pole MCB of ISI marked and a 10mm dia earth terminal point, internal wiring in ISI marked 12mm dia PVC rigid pipes including its clamps, fittings and fixtures as required as per REC drawing and Specifications. Earth point would be connected with existing earthing potential maintained by DISCOM through 10 SWG GI wire etc. as per detail scope of work.
-
-
-
Single Phase Static Energy Meter (with LCD display and data downloading feature), Accuracy Class 1.0, 5-30 A, 240V with pilfer proof box. (as per TS)
-
-
-
Un-armoured PVC Cable 2 core, 4.0 Sq mm.
-
-
-
GI Wire,10 SWG. (for Service Wire Carrier & earthing)
-
-
-
GI Pipe (25x1800) mm for earthing with required nuts-bolts & washer.
-
-
-
Piano type switch (ISI mark), 5A 240V, Switch
-
-
-
Fibre Glass Reinforced (SMC) board 350x200x40 mm for fixing Energy Meter & Cut-out.
-
-
-
Fiber Glass Reinforced Polyester Sheet Moulding Compound (SMC) board 200x150x40mm for fixing Swithes, Socket & MCB.
-
-
-
Pin type LED lamp, operating voltage range 144 -288 Volts up to 9 Watts (capable to produce minimum illumination of 710 lumens) as per specifications. Specially made for DDUGJY.
-
-
-
Bakelite/Plastic lamp holder (ISI marked) 5A, 240 volts, angle.
-
-
-
Bakelite round base to house lamp holder.
-
-
-
Three-pin socket (ISI marked) 5A, 240V.
-
-
-
16 A Double Pole Miniature Circuit Breaker (MCB) (ISI marked).
-
-
-
ISI Marked PVC 1 Core 1.5 sq.mm. copper multi-strand conductor cable as per Specification for internal wiring.
-
-
-
GI Pipe (25x3000)mm with angle, bend, socket & clamp for service support
-
-
-
Plastic Tie of required size for tieing the PVC Service Cable and the GI carrier.