Animal Husbandry And Veterinary Department Tender
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 67,420Document Cost
₹ 1,200Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_AHVD_31687_1Bid Award Id
ViewTender No
DVT-223/RIDF-XXVII (S)/Sonitpur/2022-23/ 9Tender Authority
Animal Husbandry And Veterinary Department ViewPurchaser Address
-Website
http://https://veterinary.assam.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
5.2.2A 1:1.5:3 (1 cement : 1.5 coarse sand including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 20% : 3 graded stone aggregate 20mm nominal size Recycled Concrete Aggregate (RCA) upto 20%)
3.43
-
-
6.1.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement Mortar 1:4 (1 cement : 4 coarse sand)
27.15
-
-
6.13.2 Half brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure abopve plinth level upto floor V level. Cement Mortar 1:3 (1 cement : 3 coarse sand)
277.9
-
-
16.12 Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
193.02
-
-
4.1 Providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
15.68
-
-
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns etc. for mass concrete
59.15
-
-
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
131.1
-
-
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, pillars, piers, abutments, posts and struts
166.03
-
-
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbets etc., including edges
33.08
-
-
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick
6.15
-
-
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick
48.78
-
-
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
4270.32
-
-
13.1 12mm cement plaster of mix : 1:4 (1 cement : 4 fine sand)
163.17
-
-
13.2 15mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine sand)
449.58
-
-
13.8 Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
163.17
-
-
11.5 62mm thick cement concrete flooring with concrete hardener topping, under layer 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 Kg. of cement or as per manufacture's sprcifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
137.45
-
-
10.14.1.1 Providing and fixing pressed steel door frames conforming to IS : 4351, manufactured from commercial mild steel sheet of 1.60mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25mm, or base ties of 1.60mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge. Profile B
Fixing with adjustable lugs with split end tail to each jamb.
35.7
-
-
9.145 Providing and fixing factory made PVC door frame made of PVC extruded sections of size 75mm x 53mm, having wall thickness 2.0mm (+0.2mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28mm x 30mm x 2mm thickness (+0.2mm) and 75mm x 200mm long, including reinforcing both ends of the top frame with PVC profile. PVC door frame and PVC reiforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 Nos. of 125mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacture's specification and direction of engineer-in-charge.
4.95
-
-
9.20.1 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross brands and face veneers on both faces of shutters. 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws
13.23
-
-
21.1 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6mm thick clear float glass both side, having 12mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
13.01
-
-
9.48.1 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
427.68
-
-
11.6 Cement plaster skirting upto 30cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18mm thick
121.72
-
-
11.41A Providing and laying vitrified tiles in floor in different sizes 9thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) joiniting with grey cement slurry @ 3.3 Kg./ sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, piler, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/ Antiskid finish of size Size of Tile 600 x 600mm
5.04
-
-
8.31 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 Kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
24.12
-
-
12.45.1 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive)as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200 centre to centre, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x 10 x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45 x 15 x 0.9 mm running at the spacing of 1200mm centre to centre,.....suitable for board, all as per manufacture's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer-in-Charge but excluding the cost of painting with :
12.5mm thick tapered edge gypsum plain board conforming to IS:2095 (Part-I) : 2011 (Board with BIS certification marks)
76.36
-
-
10.16 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes.
648.64
-
-
12.1.3 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead,including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
0.63mm thick with zinc coating not less than 275gm/m2
109.25
-
-
12.4 Providing ridges or hips of width 60cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63mm thick with zinc coating not less than 275gm/ m2
11.5
-
-
13.43 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
788.57
-
-
13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ litre, of approved manufacturer, of required shade and colour complete, as per manufacture's specification.
Two or more coats on new work
220.87
-
-
13.44 Finishing walls with water proofing cement paint of required shade :
New work (Two or more coats applied @3.84 Kg/ 10sqm)
554.21
-
-
13.48 Finsihing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/ 10sqm over an under coat of primer applied @0.80 ltr/ 10sqm of approved brand and manufacture.
76.32
-
-
13.50.1Applying priming coat : With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
26.46
-
-
13.50.3 Applying priming coat : With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanized iron/ steel works.
81.42
-
-
13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
26.46
-
-
2.25a Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete.
298.9
-
-
4.17 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 6 graded stone aggregate 20mm nominal size derived from natural sources) over 75mm thick bed of dry ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth).
19
-
-
Providing bird proof hexagonal galvanized wire netting at ceiling level of Assam type building including fitting and fixing with first class local wood frame of size 50mm x 25mm and beads of size 25mm x 10mm (for fitting and fixing the net with wooden frame) including lifting and fitting the same in position etc. complete as directed including two coats kiricide oiling of timber works. (PWD SCHEDULE)
7.29
-
-
Supplying and installation of signboard where necessary as directed by the department. (Rs. 8400)
1
-
-
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 100mm nominal dia pipes
10
-
-
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 80mm nominal dia pipes
3
-
-
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 25mm nominal dia pipes
14.4
-
-
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 32mm nominal dia pipes
20
-
-
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge. 40mm nominal dia pipes
30
-
-
17.40.1.2 Providing and fixing plain bend of required degree
Sand cast iron S & S as per IS : 3989
3
-
-
17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
17.7.3 Providing and fixing wash basin with C.I. brackets, 15mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required : (a) White Vitreous China wash basin size 550 x 400mm with a 15mm CP Brass single hole basin mixer
1
-
-
17.10.1.1 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510 x 1040 mm bowl depth 250mm
1
-
-
17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190 gms.
1
-
-
Providing and fixing Slotted cowel of 75mm dia Rate @215.00/ each vide Code No. 1639 of Sanitary fittings
1
-
-
19.19.1.2 Providing and fixing in position pre-cast RCC manhole cover and frame of required shape and approved quality
Square shape 450mm internal dimensions
2
-
-
19.33 Constructing soak pit 1.20 x 1.20 x 1.20m filled with brickbats including S.W. drain pipe 100mm diameter and 1.20 m long complete as per standard design.
1
-
-
10.2 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
62.03
-
-
13.48.3 Finsihing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/ 10sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture.
5.09
-
-
2.27 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
0.6
-
-
18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
-
-
18.42.3 Boring with 100mm diameter casing pipe for hand pump/ tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump/ tube well is lowered and tested : Beyond 12m and upto 18m depth
36
-
-
18.43 Providing and placing in position filters of 40mm diameter G.I. pipe with brass strainer of approved quality.
6
-
-
18.44 Providing and fixing to filter and lowering to proper levels 40mm G.I. pipe for tube well including cleaning and priming the tube well.
36
-
-
18.45 Providing and placing in position hand pump of approved quality for 40mm diameter G.I. pipe complete with all accessories.
1
-
-
23.3 Supplying, assembling, lowerig and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-Charge. 100mm nominal size dia
36
-
-
13.12 Development of tube well in accordance with IS:2800 (Part-I) and IS:11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by 'V' notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc. , all as per requirement and direction of Engineer-in-Charge.
9
-
-
18.50.1 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mm nominal bore
6
-
-
18.52 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931
15mm nominal bore
6
-
-
18.71 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.
Internal work - Exposed on wall
15mm nominal dia pipes
15
-
-
Single phase submersible motor pump set (Texmo/ Crompton Greaves/ Aquatic/ CRI/V-Guard/ Calma make) suitable for 100mm bore well and above 1.5 HP STAGE 5 to 26 with control panel. (M.rate 29589.00)
1
-
-
5.1 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement. All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources)
11.21
-
-
2.28 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead up to 50m and lift up to 1.5m.
All kinds of soil
321
-
-
10.25 Steel work welded in built up sections / framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
205.2
-
-
1.1.1 Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
4
-
-
1.1.2 Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
4
-
-
1.1.3 Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
7
-
-
1.3.2 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
4
-
-
1.6 Wiring for light/power plug with 4x4 sq. mm. FRLS PVC insulated copper conductor single core cable in surface recessed steel conduit alongwith 2 nos. 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing
47
-
-
1.7.1 Wiring for circuit wiring alongwith earth wire with the following size of LRLS PVC insulated copper conductor single core cable in surface/ Recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
59.78
-
-
1.7.4 Wiring for circuit wiring alongwith earth wire with the following size of LRLS PVC insulated copper conductor single core cable in surface/ Recessed steel conduit as required 2x6 sq.mm. + 1x6 sq. mm. earth wire
72
-
-
1.23.3 Supplying and fixing following piano type switch/socket and the existing switch box/cover including connection etc. as required. 15/16A switch
4
-
-
1.33 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connection etc. as required.
7
-
-
1.38 Supplying and fixing call bell/buzzer suitable for single phase 230 V complete as required -
1
-
-
1.45 Installation testing and commissioning of ceiling fan including wiring the down rods of standard length with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable including providing and fixing as required.
4
-
-
5.6 Earthing with copper earth plate 600x600 mm x 3mm thick including accessories and providing necessary enclosure with cover plate having locking arrangement and watering pipe of 2.7 m long etc, with charcoal coke and as required.
1
-
-
2.15.1 Supplying and fixing following rating tour pole 415 volts current circuit breaker having a sensitivity 30mm in the existing MLB DB complete with connection, testing and commissioning etc. as required. 25A
1
-
-
27.1.2 Prem. Model 1200 mm sweep orient 1200mm sweep SS-390 Deco (PWD schedule)
5
-
-
ASEB Connection (R.s.6000.00/KV)
4
-
-
Fan Hook (Market Price 273.00)
4
-
-
11.2 Erection of RCC/PCC Pole strut in brick ballast and ramming the foundation including excavation and refilling and secured with holding clamps, bolts nuts etc. as required.
2
-
-
4.1 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5% in convenient section joined with connectors suspended from …… ceiling with MS suspenders including bolts & nuts, pointing suspenders etc. as required.
36
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements