Airports Authority Of India Tender
... More
BidAssist is a very user-friendly website which helps in finding the specific Assam e-tender that one is looking for. For getting any information or detail about any e-tender the Assam government must have posted, BidAssist is designed in such a manner so as to provide information on all government tenders in one place without any inconvenience.
Costs
EMD
₹ 1,81,835Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
BOQ Title: AMC OF FIRE DETECTION AND ALARM AND FIRE FIGHTING SYSTEM AT DIBRUGARH AIRPORT
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2025/B/6095873Bid Award Id
ViewTender No
GEM/2025/B/6095873Tender Authority
Airports Authority Of India ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
atc_2025-03-28-12-42-13_9edd85a2075a7dbd0cf923caa69952c8.pdf
ATC_f44b08d1-67f6-4af8-aab01743157747131_buycon397.aai.as.pdf
list-of-categories-where-trials-are-allowed_1712126171.pdf
boq_item_sample_file2_-1_2025-03-28-12-42-13_a319c459fb7042c2965593e84723986d.csv
BOQ Items
... More
Painting at fire hydrant line with one coat of primer and two coats of synthetic enamel paint of post office red shade complete as required and as directed by Engineer-in-Charge.
For First Year
40
-
-
... More
Operation, Maintenance and Monitoring of complete Fire fighting (wet riser and Sprinkler system) and Fire detection & Alarm system installed at Terminal building, Glide Path, LLZ, DVOR, Hanger building, NBD building and Existing ATC building by engaging trained man power for carrying out the schedule maintenance & attending the breakdown complaints to ensure serviceability / satisfactory working condition and availability of the entire system in serviceable condition for operation, maintenance of records / documents etc as per special conditions of contract and as per direction of Engineer -In -Charge.
For Second year
12
-
-
... More
The execution of Delhi Schedule of Rates (E&M) 2022 of estimated amount of Rs 50,000.00 for the items mentioned in Chapter 17 & 18 as and when required basis for repair/maintenance/ addition / alteration etc. of Fire Alarm and Detection and Fire Fighting System.
[Quoting in the Rate 10% below the Estimated amount of Rs 50,000.00 means amount will be Rs.45,000/-.Similarly Quoting in the Rate 10% above the Estimated amount of Rs 50,000 means amount will be Rs. 55,000/-
(Note: Payment of DSR rate will be made after deduction of GST considered in the Rate of DSR-2022).
For Second year
50000
-
-
... More
The execution of Delhi Schedule of Rates (E&M) 2022 of estimated amount of Rs 50,000.00 for the items mentioned in Chapter 17 & 18 as and when required basis for repair/maintenance/ addition / alteration etc. of Fire Alarm and Detection and Fire Fighting System.
[Quoting in the Rate 10% below the Estimated amount of Rs 50,000.00 means amount will be Rs.45,000/-.Similarly Quoting in the Rate 10% above the Estimated amount of Rs 50,000 means amount will be Rs. 55,000/-]
(Note: Payment of DSR rate will be made after deduction of GST considered in the Rate of DSR-2022).
for First year
50000
-
-
... More
Supply , installation, testing and commissioning of Electric panel suitable for 3ph, 415V, 50HZ, 60HP sprinkler pump with enclosure protection class IP 42 as required : :125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, phase reversal relay, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. pumps should havedigital Ammeter with selector switches, and LED typeON, OFF, trip indicating lamps etc and shall be compatible with existing sprinkler pump as per site requirement and as directed by Engineer-in-Charge. For First Year
1
-
-
... More
Operation, Maintenance and Monitoring of complete Fire fighting (wet riser and Sprinkler system) and Fire detection & Alarm system installed at Terminal building, Glide Path, LLZ, DVOR, Hanger building, NBD building and Existing ATC building by engaging trained man power for carrying out the schedule maintenance & attending the breakdown complaints to ensure serviceability / satisfactory working condition and availability of the entire system in serviceable condition for operation, maintenance of records / documents etc as per special conditions of contract and as per direction of Engineer -In -Charge.
For First Year
12
-
-
... More
Quarterly / breakdown visit by OEM or OEM Authorised/ OEM recommended Service Personnel including testing of complete Fire alarm and detection system installed at Terminal building,Glide Path (New & old), LLZ(New & old), DVOR(New & old),NDB Building Hanger building and Existing ATC building at Dibrugarh Airport including programming, software updatation and serviceable the system and submission of reports etc. as per special conditions of contract and as per direction of Engineer in charge.
For Second year
4
-
-
... More
Supply, installation , testing and commissioning of pressure gauge of 150 mm dia with syphon tubing, mounting accessories,0-21 kg/ sq.cm range with 15 mm dia stop cock valve, piping etc as required and as per direction of Engineer in charge.
For First Year
6
-
-
... More
Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc and shall be compatible to operate with existing fire alarm and detection system (fire alarm control panel, Make:AGNI) etc. complete as required and as directed by Engineer-in-Charge. 06 zone control panel for fire alarm system.
For First Year
1
-
-