Urban Development And Housing Department Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Urban Development And Housing Department Tender

Civil And Construction
Eprocure
Opening Date30 Dec 2022
Closing Date6 Jan 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

37.13

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

3.71

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

3.4

-

-

... More
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.

28.18

-

-

... More
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

9.25

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

2.75

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

11.92

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).

7.36

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

11

-

-

... More
c)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

61.37

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

106.5

-

-

... More
e) Column, pillars, posts and struts etc.

33

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel

3590.73

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

23.59

-

-

... More
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.

23.59

-

-

... More
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.

1056

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

25.44

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.

54

-

-

... More
Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint b) In Tees, Angles and Channels

1.75

-

-

... More
c) In Flats up to 10 mm in thickness

3.13

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. b) 250 x 10 mm

36

-

-

... More
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm

36

-

-

... More
25 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.

67.35

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

280.63

-

-

... More
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.

35.46

-

-

... More
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.

50.88

-

-

... More
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.

50.88

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

280.63

-

-

... More
Applying one coat of cement primer of approved brand and manufacture on wall surface

280.63

-

-

... More
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).

18.96

-

-

... More
Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom andplastering and all exposed surfaces with 12 mm thick cementmortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.

51.92

-

-

... More
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore

16

-

-

... More
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore

4

-

-

... More
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan

1

-

-

... More
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm

1

-

-

... More
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.

1

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia

8

-

-

... More
Providing and fixing sand cast iron heel rest sanitary bend. a) 100 mm dia

1

-

-

... More
Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. c) 100 mm inlet and 50 mm outlet

3

-

-

... More
Internal Electrification :-

-

-

-

... More
SUB-HEAD-1 (WIRING)

-

-

-

... More
Note : Rates of only ISI marked M.S. conduit, FR PVC insulated copper conductor single core cables, moulded plate type switches in passivated box and FR PVC insulated earth wire have been taken in the following items unless otherwise specified and as per specification. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Light Points Group A

7

-

-

... More
Group B

3

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Fan points Group B

4

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

20

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

60

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

10

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm

60

-

-

... More
2 x 6 sq. mm

10

-

-

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.

4

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep

6

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 15/16 A switch

2

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

4

-

-

... More
SUB-HEAD-II (FITTINGS & ACCESSORIES)

-

-

-

... More
ERRECTION OF FANS & LIGHT FIXTURES: Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm

4

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

10

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

4

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required Upto 450 mm sweep

1

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

1

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required

15

-

-

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required

10

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

1

-

-

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

10

-

-

... More
SUPPLY OF FANS & LIGHT FIXTURES

-

-

-

... More
Light/fan fixtures :- Supply and of following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips or equivalent/Wipro/Thron). 1 x 18 W FTL, Wall mounted type indoor light fixture

9

-

-

... More
Ceiling fans: Supplying and of 1200 mm sweep ceiling fan with 300/600 mm standard down rod and electrical connection as required etc. Exhaust fans

4

-

-

... More
Supply of heavy duty type exhaust fans of following size sweep with gravity louvers shutters including all accessories/installation materials required make HAVELS/USHA. 450 mm sweep 900 rpm

1

-

-

... More
SUB-HEAD-III (DB's AND MAIN SWITCH)

-

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door

1

-

-

... More
240/415 V, 10 kA, "C" curve, miniature circuit breaker Single pole and neutral

5

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

1

-

-

... More
SUB-HEAD-IV (EARTHING)

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

2.5

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

10

-

-

... More
LIGHTENING PROTECTION

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

1

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

3

-

-

... More
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)

2.5

-

-

... More
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.

1

-

-

... More
Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.

2.5

-

-

... More
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.

1

-

-

... More
Add Carraiage for Type-III Qtr (1nos)

1

-

-

... More
SH: C/o Type-II Quarter (4nos.)

-

-

-

... More
SITE DEVELOPMENT

-

-

-

... More
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.

3514.37

-

-

... More
BUILDING PORTION

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

173.25

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

14.85

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

15.79

-

-

... More
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.

104.37

-

-

... More
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

33.73

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

16.83

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

37.93

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).

29.84

-

-

... More
Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)

8.22

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

66

-

-

... More
c)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

248.65

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

416.17

-

-

... More
e) Column, pillars, posts and struts etc.

158.4

-

-

... More
f) Stairs (excluding landings) except spiral stair cases

13.7

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel

13453.92

-

-

... More
Steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red lead paint b) In Tees, Angles and Channels

6.35

-

-

... More
c) In Flats up to 10 mm in thickness

13.69

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

74.47

-

-

... More
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.

74.47

-

-

... More
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.

3882.38

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

102.72

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.

205.2

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. b) 250 x 10 mm

128

-

-

... More
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm

128

-

-

... More
25 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.

224.85

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

927.22

-

-

... More
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.

97.03

-

-

... More
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.

198.72

-

-

... More
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.

198.72

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

927.22

-

-

... More
Applying one coat of cement primer of approved brand and manufacture on wall surface

61.87

-

-

... More
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).

61.87

-

-

... More
Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.

117.1

-

-

... More
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore

64

-

-

... More
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore

12

-

-

... More
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan

4

-

-

... More
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm

4

-

-

... More
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.

12

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia

32

-

-

... More
Providing and fixing sand cast iron heel rest sanitary bend. a) 100 mm dia

4

-

-

... More
Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. c) 100 mm inlet and 50 mm outlet

12

-

-

... More
Internal Electrification :-

-

-

-

... More
SUB-HEAD-1 (WIRING)

-

-

-

... More
Note : Rates of only ISI marked M.S. conduit, FR PVC insulated copper conductor single core cables, moulded plate type switches in passivated box and FR PVC insulated earth wire have been taken in the following items unless otherwise specified and as per specification. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Light Point Group A

28

-

-

... More
Group B

12

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Fan Points Group A

12

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

80

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

240

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

40

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm

240

-

-

... More
2 x 6 sq. mm

40

-

-

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.

16

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep

16

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 15/16 A switch

8

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

12

-

-

... More
SUB-HEAD-II (FITTINGS & ACCESSORIES)

-

-

-

... More
ERRECTION OF FANS & LIGHT FIXTURES

-

-

-

... More
Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm

12

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

12

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

4

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required

40

-

-

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required

40

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.

4

-

-

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

40

-

-

... More
SUPPLY OF FANS & LIGHT FIXTURES

-

-

-

... More
Light/fan fixtures :- Supply and of following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips or equivalent/Wipro/Thron). 1 x 18 W FTL, Wall mounted type indoor light fixture

40

-

-

... More
Ceiling fans: Supplying and of 1200 mm sweep ceiling fan with 300/600 mm standard down rod and electrical connection as required etc.

12

-

-

... More
SUB-HEAD-III (DB's AND MAIN SWITCH)

-

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N

4

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door

4

-

-

... More
240/415 V, 10 kA, "C" curve, miniature circuit breaker Single pole and neutral

16

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

4

-

-

... More
SUB-HEAD-IV (EARTHING)

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

10

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

40

-

-

... More
LIGHTENING PROTECTION

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

4

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

12

-

-

... More
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)

10

-

-

... More
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.

4

-

-

... More
Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.

10

-

-

... More
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.

4

-

-

... More
Add carraige for Type-II Qtr (4nos)

1

-

-

... More
SITE DEVELOPMENT

-

-

-

... More
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.

480

-

-

... More
BUILDING PORTION

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

40.5

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

4.05

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

3.6

-

-

... More
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.

32.28

-

-

... More
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

14.49

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

3

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

12.35

-

-

... More
Providing best available local wood (Class - B II) work in frames of false ceiling, partitions and trusses etc, sawn and put up in position

126

-

-

... More
Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approvedquality with necessary nails etc.complete (frame work for base to be paid separately).

84

-

-

... More
Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. a) Best local approved quality wood

15

-

-

... More
Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses a) 0.80 mm thick GI sheet

125

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

12

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

90.04

-

-

... More
e) Column, pillars, posts and struts etc.

48

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel

2340.26

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

27.17

-

-

... More
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.

27.17

-

-

... More
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.

1010.95

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

25.4

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.

46.24

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. b) 250 x 10 mm

22

-

-

... More
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm

40

-

-

... More
25 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.

93.45

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

275.69

-

-

... More
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.

10.28

-

-

... More
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.

50.79

-

-

... More
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.

50.79

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

275.69

-

-

... More
Applying one coat of cement primer of approved brand and manufacture on wall surface

275.69

-

-

... More
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).

19.05

-

-

... More
Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cmthick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cementmortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.

41.2

-

-

... More
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore

24

-

-

... More
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore

6

-

-

... More
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan

3

-

-

... More
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm

3

-

-

... More
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.

6

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia

15

-

-

... More
Providing and fixing sand cast iron heel rest sanitary bend. a) 100 mm dia

3

-

-

... More
Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. c) 100 mm inlet and 50 mm outlet

9

-

-

... More
Internal Electrification :-

-

-

-

... More
SUB-HEAD-1 (WIRING)

-

-

-

... More
Note : Rates of only ISI marked M.S. conduit, FR PVC insulated copper conductor single core cables, moulded plate type switches in passivated box and FR PVC insulated earth wire have been taken in the following items unless otherwise specified and as per specification. Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Light Points Group A

6

-

-

... More
Group B

6

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required Fan Points Group A

3

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

30

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

75

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire

10

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm

75

-

-

... More
2 x 6 sq. mm

10

-

-

... More
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.

6

-

-

... More
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep

3

-

-

... More
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required 15/16 A switch

3

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

3

-

-

... More
SUB-HEAD-II (FITTINGS & ACCESSORIES)

-

-

-

... More
ERRECTION OF FANS & LIGHT FIXTURES

-

-

-

... More
Supply and fixing circular/ hexagonal M.S. sheet ceiling fan box with clamp of internal dia 140mm, 73 mm height, 3mm thick rim top lid of 1.5mm thick M.S sheet lidss shall be screwed into M.S. box by means of 3mm round headed screws, clamps shall be made of 12 mm dia M.S bar bent to be shape as per standard drawing with over all length as 80 cm

3

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

12

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

3

-

-

... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required

12

-

-

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required

12

-

-

... More
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

12

-

-

... More
SUPPLY OF FANS & LIGHT FIXTURES

-

-

-

... More
Light/fan fixtures :- Supply and of following type fluorescent/CFL fixtures shall be complete with Electronic Ballast, PF improvement capacitor, Control gear box. Bipin Rotor type lamp holder, starter, starter base, all pre wired upto the terminal block. All fixtures shall be supplied with lamps.(make Philips or equivalent/Wipro/Thron). 1 x 15W FTL, Wall mounted type indoor light fixture

12

-

-

... More
Ceiling fans Supplying and of 1200 mm sweep ceiling fan with 300/600 mm standard down rod and electrical connection as required etc.

3

-

-

... More
SUB-HEAD-III (DB's AND MAIN SWITCH)

-

-

-

... More
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N

1

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door

1

-

-

... More
240/415 V, 10 kA, "C" curve, miniature circuit breaker Single pole and neutral

3

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

1

-

-

... More
SUB-HEAD-IV (EARTHING)

-

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)

2.5

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

6

-

-

... More
LIGHTENING PROTECTION

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

1

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

5

-

-

... More
Providing and fixing GI-tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor as required.(for vertical run)

3

-

-

... More
Providing and fixing testing joint, made of 20 mm x 3 mm thick gi strip, 125 mm long with 4 Nos. brass bolts, nuts check nuts and spring washers etc. complete as required.

1

-

-

... More
Providing and laying GI tape, 32 mm x 6 mm thick from earth electrode directly in ground as required.

2.5

-

-

... More
Earthing with G.I. Earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt complete as required.

1

-

-

... More
Add carraige for Bachelor Barracks

1

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

126.36

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

15.38

-

-

... More
Half brick masonry (with best available local bricks)in cement mortar 1:3 (1cement : 3 coarse sand) in foundation and plinth.

129.84

-

-

... More
Extra for half brick masonry in superstructure above plinth level and up to floor two level.

129.84

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).

5.09

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete

21.72

-

-

... More
b)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

8.13

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild Steel

1365.66

-

-

... More
15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.

156.84

-

-

... More
Neat cement punning.

156.84

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. A) 100 mm dia.

60

-

-

... More
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design

6

-

-

... More
Add Carrige for Septic Tank

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.