Urban Development And Housing Department Tender

... More
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Urban Development And Housing Department Tender

Works
Building Construction
Eprocure
Opening Date25 Feb 2025
Closing Soon5 Mar 2025
Tender Amount₹ 4,39,76,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

129.35

-

-

... More
Providing and laying in foundations and plinth cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering.

147.58

-

-

... More
Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size)

47.97

-

-

... More
Extra for providing and mixing water proofing material in cement concrete work in the proportion recommended by manufacturers.

12.28

-

-

... More
Applying a coat of hot bitumen (mashphalte 80/100 or equivalent) using 1.70 kg. per sqm. on damp proof course after cleaing the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

47.97

-

-

... More
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.

51

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in: M20 (1 cement : 1.5 cparse samd : 3 stone aggregate 20mm nominal size)

94.58

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size).

114

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement :3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a. M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size).

206.8

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size)

184.19

-

-

... More
Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20mm nominal size)

5.55

-

-

... More
Centring and shuttering including strutting, propping etc. and removal of form work for: Foundation, footings, bases of columns etc. and mass concrete.

204.78

-

-

... More
Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5m height)

1305.52

-

-

... More
Lintels, beams, girders, bressumers and cantilevers etc.

1515.64

-

-

... More
Column, pillars, posts and struts etc.

790

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Tar/ TMT steel

68915.11

-

-

... More
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).

504.21

-

-

... More
Half brick masonry (with best available local bricks) in cement mortar 1:4 (1cement: 4 coarse sand) in foundation and plinth.

230.28

-

-

... More
Grading Roof for water proofing treatment with:Cement Mortar 1:3 (1 cement :3 coarse sand)

52

-

-

... More
Providing gola 75 x 75 mm in cement concrete 1:2;4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge) including finishing with cement mortar 1 : 3 ( 1 cement : 3 fine sand) as per standard design :

133

-

-

... More
Providing and fixing on wall face C.I Rain water pipes including filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2. 100 mm diameter

48

-

-

... More
Providing and fixing M.S. Holder bat clamps of approved design of C.I. or S.C.I. pipes embedded in and including cement concrete block 10mm x 10cm x 10cm of 1:2:4 mix (1 cement : 2 coarse sand: 4 stone aggregate 20mm nominal size) including cost of cutting holes and making good the wall etc. 100 mm diameter

30

-

-

... More
Providing and fixing on wall face C.I. accessories for rain water pipes including filling the joints with spun yarn soaked in neat cement slurry and cement mortar 1:2 (1 cement : 2 fine sand) b)- CI Plain Bend-100mm dia

10

-

-

... More
b)- CI Plain shoe-100mm dia

10

-

-

... More
Making khurras 45 x 45 cm with avg. minimum thickness of 5 cm cement concrete 1 : 2 : 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1 mm x 1 m x 400 micron, finished with 12 mm cement plaster 1 : 3 ( 1 cement : 3 coarse sand) and finishing the outlet complete as per drawing.

6

-

-

... More
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity 0.043 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e.50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. (600 x 600)

598

-

-

... More
Providing and fixing Durashine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet roofing fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutting hoisting and fixing complete, excluding the cost of purlins, rafters and trusses.

1031.4

-

-

... More
Door /Window / Ventilator Frames:- Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineer- in-charge.

241.6

-

-

... More
Providing and fixing flush door shutters, decorative type, core of black board construction with frame of 1st class hard wood and well matched 1st class teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) 40mm thick including anodized aluminum butt hinges with necessary screws.

86.1

-

-

... More
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).

228

-

-

... More
Providing and fixing aluminum handles anodised transparent or dyed to required color or shade with necessary screws etc complete. 125 mm

76

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 300 x 10 mm

38

-

-

... More
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm

38

-

-

... More
Providing and fixing 50 cm long aluminum kicking plate 100x3.15mm anodised, transparent or dyed to required color or shade with necessary screws etc. complete.

38

-

-

... More
Providing and fixing chromium plated finished 100mm mortice latch and lock with 6 levers and a pair of CP handles with necessary screws etc.

18

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 60x60 cm refer carpet area calculation

1389.62

-

-

... More
SKIRTING/ DADO : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 12mm thick cement mortar 1:3 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm

138.96

-

-

... More
Providing and fixing 1 st quality ceramic glazed wall tiles confirming to IS: 15622 ( thickness to be specified by manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any sizes as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 Cement : 3 Coarse sand) and joining with grey cement slurry @3.30kg per sqm including pointing with white cement mixed with pigment of matching shade complete.

357

-

-

... More
Providing and laying rectified Glazed Ceramic floor tiles of size 300x30 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. sqm 1225.10 shades, except White, Ivory, Grey, Fume Red Brown laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.

111.22

-

-

... More
Providing and laying gang saw cut 18 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. With granite stone of area less than 0.50 sqm

201.2

-

-

... More
First class Indian teak wood 25 mm wooden plankings tongued and grooved in flooring including fixing with screw complete.

224.48

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a approved steel priming coat using structural steel as required in gratings, frames, guard bars, railings, brackets, gates, grills etc.

1424.25

-

-

... More
Providing and fixing T-iron frames to door of mild steel Tee-Section, joint mitred and welded with 15x3mm lugs 10 cm long embeded in cement concrete block 15x10x10 cm of 1:3:6 (1 cement:3 course sand:6 graded stone aggregate 20 mm nominal size) with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of steel primer.

887.88

-

-

... More
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).

23200.96

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

726

-

-

... More
12 mm thk cement plaster 1: 4( 1 cement : 4 coarse sand) on walls.

1909.99

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement :4 fine sand)

1909.99

-

-

... More
Applying one coat of cement primer of approved brand and manufacture on wall surface.

3819.99

-

-

... More
Finishing walls with water proofing cement paint of required shade :

1909.99

-

-

... More
Wall painting (two or coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.

4426.35

-

-

... More
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works.

319.95

-

-

... More
With ready mixed pink primer of approved brand and manufacture on resinous wood and plywood works.

189.42

-

-

... More
painting with synthetic enamel paint of approved brand and manufacture to give an even shade- 2 or more coats

621.54

-

-

... More
Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with aluminum paint of approved quality over a priming coat of ready mixed genuine red lead on new work.

32

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : Anodised Aluminium (anodised transparant or dyed to required shade according to IS:1868, minimum anodic coating of grade SC-15)

1596.12

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) With float glass panes of 5.5 mm thickness.

94.95

-

-

... More
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineer-incharge complete. 255 X 19 mm.

45

-

-

... More
Electrical works

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

125

-

-

... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.

4

-

-

... More
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

400

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

380

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

110

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

50

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

125

-

-

150

-

-

55

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

8

-

-

... More
TV antenna socket outlet

4

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

55

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

30

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)

45

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

22

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

15

-

-

... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.

10

-

-

... More
Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.

160

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

15

-

-

... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep

8

-

-

... More
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.

8

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. For Data & CCTV 1 run of cable

125

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC copper conductor single core cable etc. as required. insulated Group C

40

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

12

-

-

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.

8

-

-

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required.

10

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door

1

-

-

... More
Supplying and fixing following way surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCBs & incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required) 8 way (4 + 24), Double door

1

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole

24

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

3

-

-

... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

3

-

-

... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A

4

-

-

2

-

-

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A

1

-

-

1

-

-

1

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB

2

-

-

... More
Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.

6

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

4

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

55

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

20

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

150

-

-

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

150

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.

2

-

-

... More
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.

2

-

-

... More
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.

20

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)

175

-

-

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)

35

-

-

... More
Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.

15

-

-

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.

1

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm

75

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Above 185 sq. mm and upto 400 sq. mm

15

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

245

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

15

-

-

... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

2

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 10 sq. mm (19mm)

12

-

-

... More
3½ X 185 sq. mm (57mm)

2

-

-

... More
4 X 10 sq. mm (25mm)

8

-

-

... More
4 X 16 sq. mm (28mm)

16

-

-

... More
Main Incomer 250 amps TPN MCCB (35KA) terminals suitable to receive 1 x 3.5 x185 sq. mm XLPE AL.AR. cable connection on one side and Busbar connection on the other side. 300 Amps TPN busbar, chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips current density of aluminium shall not be more than 0.8 Amps/ sq.mm. 3 nos phase indicating lamps each backed up with MCB and switch shall be provided for incomer. Provide Intelligent Panel Meter - Scheinder -Model No-EM-6400NG (96 mm x 96 mm) covering 25 electrical parameters with RS 485 port for incomming feeder. 2 Nos. 100 A TPN MCCB (25 kA) terminals suitable to receive cable on one side and wire connection to Bus bars.. 10 Nos. 63 A 4P MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars.. 4 Nos. 40 A 4P MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars.. Main panel as described above and specifications complete.

1

-

-

... More
The SDB UPS in Electrical room shall consists of: Main Incomer 100 amps TPN MCCB (25KA) terminals suitable to receive 4 x 1 x 16sq. Mm copper cable connection on one side and Busbar connection on the other side. 150 Amps TPN busbar, chamber of suitable length with copper busbars. All busbars and interconnections shall be of suitable size copper strips current density of copper shall not be more than1.6 Amps/ sq.mm. 3 nos phase indicating lamps each backed up with MCB and switch shall be provided for incomer. Provide Intelligent Panel Meter - Scheinder -Model No-EM-6400NG (96 mm x 96 mm) covering 25 electrical parameters with RS 485 port for incomming feeder. 8 Nos. 40 A DP MCB (10 kA) terminals suitable to receive cable on one side and wire connection to Bus bars.. SDB UPS as described above and specifications complete.

1

-

-

... More
Rates of only ISI marked conduits, cables, switches and socket outlets have to be taken in the following items. Unless and otherwise specified, only such conduits, cables, switches and socket outlets shall be used in the work. Providing and fixing of Krone make Telephone Tag Block of following pairs consisting of necessary Back Mount Frame, disconnection modules and grommets complete as required. 50 pair Telephone Tag Block

1

-

-

... More
Supply,drawing and making connections with Telephone Main Junction box and Telephone Junction Box with annealed tinned copper conductor (ATC) , PVC insulated and PVC sheathed GI strip armoured Telecommunication cable in False Ceiling/on ceiling from the P & T Junction Box to the Main Telephone junction box includ­ing supporting arrangements from the roof complete with all accessories as required. 20 pair ( 0.61mm ) armoured Telephone cable.

109

-

-

... More
Supplying the following Lighting fixtures including lamps at site. Rate shall include all taxes and duties, transportation etc. complete. Samples of all light fixtures to be submitted to the client for approval prior to procurement of fixtures) WIPRO,(Immaculate DD LED) 33W, Recess mounted- 600 x 600 Type Light Fixture- LM24-421-XXX-57-DD Polycarbonate, Edge Glow Surface LED Downlighter with 270 degree light spread- 3600 lumen, 6500K

60

-

-

... More
P/F PHILIPS Tube Light LED, 1200 length, 15 Watt, 6500K, 2500 Lumen

45

-

-

... More
Emergency exit light

6

-

-

... More
48" dia (1200 sweep) double ball bearing ceiling fan Crompton/Usha/ Havels

18

-

-

... More
12" dia 1 phase exhaust fan, 1400 RPM (Havels make)

8

-

-

... More
Supply of gravity and bird guard screen louvers for exhaust fan

8

-

-

... More
Supply and laying, effecting proper connec­tions, testing & commissioning of the following sizes of 1.1 KV armoured XLPE / unarmoured Cross linked polyethylene insulated, PVC sheathed (XLPE), conforming to IS: 7098 (Part-1)- 1988 ( 90 deg C) aluminium /copper conductor cables conforming to IS : 1554 and IS 694 for Flexible copper cable Part I - 1976 with latest amendments laid over MS supports in existing RCC ducts/ laid in ground /laid on Cable Trays including clamping the cables to sup­ports in an approved manner as required complete with all accessories.All cables shall have thermo setting insulation XLPE and low emission of smoke and corrosive gas when affected by fire 4 c x 16 sq.mm armoured XLPE insulated aluminium cable

190

-

-

... More
4 c x 10 sq.mm armoured XLPE insulated aluminium cable

55

-

-

... More
2 c x 10sq.mm armoured XLPE insulated copper cable

45

-

-

... More
3.5 c x 185 sq.mm armoured XLPE insulated aluminium conductor cable

55

-

-

... More
Supply, Installation, Testing & Commissioning of IP Based CCTV System comprising of following: Supply, Installation, Testing and commissioning of 2.0 MP IP Dome Camera, True Day Night camera with IR Illuminator, 1/2.8" CMOS or better, 2 MP @ 25fps, Min. Illumination required 0.01 lux @F1.4 (color) Lux IR On, AGC - Auto/Manual, 120dB True WDR, Min. Pixels 1920 x 1080 , triple stream, Wide Angle lens 2.8 mm IR corrected lens with angle of view of 120° or better, BLC, HLC, 3DNR, high power LEDs IR with upto 20m IR distance PoE, H.264 High Profile and MJPEG, PoE and 12V DC including cable termination and fixing accessories complete in all respect as per instruction of engineer in-charge.

10

-

-

... More
Supply Installation Testing & commissioning of 2MP IP IR BULLETT CAMERA 2MP IR Outdoor Bullet camera with Motorised Vari-focal Lens,1/2.8" Progressive Scan CMOS, ICR, 0.014Lux/F1.4, 0 lux with IR, Slow shutter, 1920x1080 : 25/30fps, 2.8~12mm/F1.4 Motorized VF lens, H.264/MJPEG/MPEG4, Triple-Stream, Support Intrusion detection, scene change detection, Line crossing detection, motion detection, Support SD/SDXC Card up to 64GB, UP to 30m IR, IP67, DC12V/PoE, Full HD, DWDR, 3D DNR, HLC, Smart IR, 30m IR ONVIF, UL LISTED. CERTIFICATE CE & FCC.

2

-

-

... More
16 Chanel Network Video Recorder Suitable for 30 days 24 hrs recording hard disk capacity Including providing syitable software complete as required etc.

1

-

-

... More
Viewing Station Intel® i7 2600 3.4Ghz/ or higher,» 4 GB of RAM DDR 3 or more » 80 GB of SATA II hard disk for OS & Application or more » 2 GB Graphics Card with 3 Monitor Output » 1600 x 1200 or higher screen resolution » 10/100/1000 Ethernet Network Interface Card » 16x ( HP Make ) Client scope

1

-

-

... More
Supply/Installation/Testing/Commissioning of 32” CCTV color LED Monitor i and all accessories cable connections etc. complete as required.

1

-

-

... More
Networking Cat 6 24 Port Jackpanel - loaded- A DATA

1

-

-

... More
S/I/T/C of Managed Layer 2 POE Ethernet Switch with 24 channel port 10/100/1000 Mbps including lockable racks and other accessories (Max .data transfer rate is 1 GB/S )

1

-

-

... More
6 U rack for CCTV Application Server & Storage

1

-

-

... More
Cat 6 Information Outlets - Blue -Active DATA (User side)

10

-

-

... More
Patchcords- CAT 6- 4 fts-Blue- ( RJ45-RJ45 ) for Resource side (Active Data)

11

-

-

... More
Plumbing works

-

-

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P flush bend with fitting & C.I brackets,40mm flush bend,overflow arrangement with special of standard make and mosquito proof coupling of approved municipal design complete including painting of fitting and bracketss,cutting and making good the walls and floors wherever required. W.C pan with ISI marked white solid plastic seat and lid.

20

-

-

... More
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x430x265 mm sizes respectively with CI automatic flushing cistern with fittings, RS or CI brackets standard size galvanized steel flush pipe and spreaders with brass unions and GI clamps complete including painting of cistern and fittings, cutting and making good the walls and floors where required. b) Range of two urinals with 10 Litre CI automatic flushing cistern

8

-

-

... More
Providing and fixing white vitreous china wash basin with C.I./M.S. brackets, 15 mm CP brass pillar taps, 32 mm CP brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : Flat back wash basin size 550x450 mm with a single 15 mm CP pillar tap

15

-

-

... More
Providing and fixing CP Brass Waste for for wash basin and sinks. 40mm dia

15

-

-

... More
Providing and fixing CP Brass or MI trap for wash basin and sinks. 40 mm dia

15

-

-

... More
Providing and fixing rubber plug for sink or wash basin.

15

-

-

... More
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with CP brass screws and washers.

15

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste & vent pipes. 100 mm dia

140

-

-

... More
75 mm dia

77

-

-

... More
Providing and fixing sand cast iron heel rest sanitary bend. 100 mm

22

-

-

... More
75 mm dia

25

-

-

... More
50 mm dia

18

-

-

... More
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 x100x100 mm

2

-

-

... More
Providing and fixing sand cast iron trap of self cleaning design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet

35

-

-

... More
100 mm inlet and 75 mm outlet

25

-

-

... More
100 mm inlet and 50 mm outlet

18

-

-

... More
Painting sand cast iron soil spun soil waste vent pipes and fittings with paint of any color such as chocolate, grey or buff etc over a coat of primer (of approved quality) for new work. 100 mm diameter pipe

140

-

-

... More
75 mm dia

45

-

-

... More
G I Pipes and Fittings Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good the walls etc. (internal work) 20 mm dia nominal bore

120

-

-

... More
25 mm dia nominal bore

150

-

-

... More
32 mm dia nominal bore

80

-

-

... More
Painting GI Pipes & fittings with 2 coats of anti-corrosive bitumastic paint of approved quality. 20 mm dia nominal bore

120

-

-

... More
25 mm dia nominal bore

150

-

-

... More
32 mm dia nominal bore

80

-

-

... More
Providing and fixing brass full way valve with wheel of approved quality. 32 mm nominal bore

6

-

-

... More
Providing and fixing ball valve (brass) of approved quality complete 20 mm nominal bore

10

-

-

... More
Providing and placing on terrace ( at all floor levels ) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

8000

-

-

... More
Providing and fixing CP brass bib cock of approved quality conforming to IS : 8931 20 mm Nominal bore

8

-

-

... More
Providing and fixing brass stop cock of approved quality. 15 mm Nominal bore

8

-

-

... More
Providing and fixing CP brass angle valve for wash basins mixer and geyser points of approved quality confirming to IS:8931 15mm nominal bore

40

-

-

... More
Providing and fixing PVC Connection pipe with brass union 30 cm length, 15mm nominal bore

40

-

-

... More
Drainage System Providing laying and jointing glazed stone ware pipe grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 150 mm

175

-

-

... More
200 mm

65

-

-

... More
Providing and laying cement concrete 1 : 5 : 10 (1 cement : 5 lime sand : 10 graded stone aggregate 40 mm nominal size) all around SW Pipe including bed concrete 15 cm thick as per standard design. 150 mm

175

-

-

... More
200 mm

65

-

-

... More
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).

7

-

-

... More
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.

1

-

-

... More
Providing and fixing square mouth SW gully trap class SP-1 complete with CI grating brick masonry chamber and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg. as per standard design. 180x150mm size P type, With common burnt clay FPS(non modular) bricks of class designation 7.5.

8

-

-

... More
SH : Construction of Pathway 3 mtr width with Cement concrete

-

-

-

... More
Earth work in surface excavation not exceeding 30 com in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5m disposed soil to be levelled and neatly dressed: Ordinary soil

720

-

-

... More
Providing and laying cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) excluding the cost of centring and shuttering in:

108

-

-

... More
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cemnet: 4 fine sand)

16.56

-

-

... More
Cement concrete pavement (Construction of un-reinforced, dowel jointed plain cement concrete pavement over a prepared sub base with 43 grade cement @400kg per cum, coarse and fine aggregate conforming to IS383, maximum size of coarse aggregate not exceeding 25mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continous operation including provision of contraction, expansion, construction and longitudinal joints, joints filler, separation memberance, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing)

10.8

-

-

... More
Storm Water Drain

-

-

-

... More
Earth work in excavation in foundation trenches not exceeding 1.50 m width or 10 Sq.m. on plan or drains not exceeding 1.50 m in width or 10 Sq.m. on plan including dressing of sides and ramming of bottoms, lift upto 1.50 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. Hard Soil

161.98

-

-

... More
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring an shuttering in:

15.88

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

46.53

-

-

... More
Pre cast RCC Slab M-20 Grade: Providing, hoisting and fixing up to floor two level precast reinforced cement concrete in shelves including finishing and plastering with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm on exposed surfaces to give a smooth and even surface including shuttering etc but excluding cost of reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 12.50 mm nominal size).

11.91

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : Walls

492.28

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. Tar/TMT steel

3064.84

-

-

... More
15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall.

357.3

-

-

... More
Neat cement punning.

357.3

-

-

... More
Septic Tank

-

-

-

... More
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.

105

-

-

... More
Cement Treated Soil Sub Base/ Base (Providing, laying and spreading soil on a prepared sub grade, pulverising, adding the designed quantity of cement to the spread soil, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub base

6.07

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

6.07

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

4.51

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

15

-

-

... More
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

6.3

-

-

... More
Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. b) TMT Steel

451.42

-

-

... More
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).

22.06

-

-

... More
15 mm thk cement plaster 1:4(1cement :4 fine sand)

59

-

-

... More
Neat Cement Punning

59

-

-

... More
Constructing brick masonry manhole with 2nd class bricks in cement mortar 1: 5 (1 cement :5 fine sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone single 20 mm nominal size), foundation concrete 1 : 4 : 8 mix (1 cement : 4 coarse sand : 8 stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1 : 3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) neatly finished complete as per standard design. a) Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover and frame to be not less than 38 kg, (weight of cover 23 Kg and weight of frame 15 Kg).

2

-

-

... More
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.