Urban Development And Housing Department Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Urban Development And Housing Department Tender

Works
Civil And Construction
Building Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date11 Jan 2024
Closing Date30 Jan 2024
Tender Amount₹ 15,39,38,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.50 coarse sand : 3 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth

168.19

-

-

... More
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

252.28

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

199.88

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

430.68

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

333.95

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

173.45

-

-

... More
Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

16.76

-

-

... More
Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

2.21

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

237.12

-

-

... More
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

3083.43

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

3771.37

-

-

... More
e) Column, pillars, posts and struts etc.

1752.19

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.

191525.43

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

1375.99

-

-

... More
Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.

3791.9

-

-

... More
Extra for half brick masonry in superstructure above plinth level and up to floor two level.

3791.9

-

-

... More
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.

659.02

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

176.09

-

-

... More
Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for 9.147A.1 Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm & sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glass pane glazing bead of appropriate dimension. (Area of window upto 0.75 sqm.)

371.88

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.

7437.6

-

-

... More
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm

89

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 300 x 10 mm

178

-

-

... More
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm

178

-

-

... More
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).

13540.95

-

-

... More
Polycarbonate sheet roofing [This versatile thermoplastic maintains its properties over a wide range of temperatures, from -40”F to 280”F. It has the highest impact resistance of any Thermoplastic, transparent up to 2” in special grades, outstanding dimensional and thermal stability, exceptional machinability, stain resistant and non-toxic while having low water absorption

1682.51

-

-

... More
Providing and fixing Durasr,ine zinc-Aluminium alloy coated (TATA Bluescope building product) sheet ridges fixed with necessary fasteners and lapping method as described by the manufacturer inclusive of cutling hoisting and fixing complete, excluding the cost of purlins, rafters and trusses. Details of cost for 11.75m Laying and fixing 4 lenths of 3.05m each require Overall length of 4 x 3.05 plus 3% wastages = 12.566m After laping as per manufacturer's specification, effective Measurable length wi be (4 x 3.05) - (3 Q..15) = 11.75m

54.45

-

-

... More
Providing and fixing 12 mm thick insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately).

966.08

-

-

... More
Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. a) Best local approved quality wood.

966.08

-

-

... More
Extra for chamfered edges in beading

966.08

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete. d) size of tiles 1000x1000mm

2900.6

-

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. d) Size of Tile 1000x1000 mm

247.07

-

-

... More
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.

858.27

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

280.4

-

-

... More
Pre-cast terrazzo tiles 20 mm thick with marble chips of sizes upto 6 mm in skirting and risers of steps not exceeding 30 cm in height on 12 mm thick cement plaster 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry including rubbing and polishing complete with tiles of : a) Light shades using white cement

29.98

-

-

... More
Chequered terrazzo tile_s 22 mm lhick with marble chips of sizes upto 6mm in floors on 25 mm thick bed mortar 1 : 3 (1 cement : 3 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete: a) Light shades using white cement

277.88

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

9006.84

-

-

... More
Painting two coats with oil type wood preservative of approved brand and manufacture on new work.

409.38

-

-

... More
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.

409.38

-

-

... More
Applying one coat of distemper primer of approved brand and manufacture on wall surface.

1952.57

-

-

... More
Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade

1952.57

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

9006.84

-

-

... More
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).

203.83

-

-

... More
Providing and fixing of stainless steel railing of best quality and approved brand including accessories and fittings.

338.4

-

-

... More
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.

246.48

-

-

... More
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore

297

-

-

... More
b) 20 mm nominal bore

468

-

-

... More
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 15 mm nominal bore

705

-

-

... More
b) 20 mm nominal bore

117

-

-

... More
d) 32 mm nominal bore

78

-

-

... More
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore

39

-

-

... More
Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore

39

-

-

... More
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required. a) Long Pan patten WC Pan

20

-

-

... More
Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain in enamel led flush band, 20 mm over flow pipe with specials and mosquito proof coupling of approved municipal design complete including cutting and making good the walls and floors where required. a) WC pan with white plastic seat and lid.

19

-

-

... More
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.

33

-

-

... More
Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC. a) 250 x 130 x 30 mm

40

-

-

... More
Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete.

39

-

-

... More
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.

39

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia

178

-

-

... More
c) 50 mm dia

156

-

-

... More
Providing and fixing sand cast iron heel rest sanitary bend .a) 100 mm dia

156

-

-

... More
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm

39

-

-

... More
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. c) 100 mm inlet and 50 mm outlet

39

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:

648.04

-

-

... More
External water and Electrical service connection

1

-

-

... More
Add Carriage Charges

1

-

-

... More
Add internal electrification

-

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

457

-

-

... More
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C

23.4

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

291

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

1056

-

-

... More
2 X 4 sq. mm +1 X 4 sq. mm earth wire

2100

-

-

... More
2 X6 sq. mm + 1 X 6 sq. mm earth wire

630

-

-

... More
4 X 1.5 sq. mm + 2 X 1.5 sq. mm earth wire

1091

-

-

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

792

-

-

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

1575

-

-

... More
4 X 10 sq. mm + 2 X 6 sq. mm earth wire

40

-

-

... More
4 X 16 sq. mm + 2 X 6 sq. mm earth wire

70

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

100

-

-

... More
25 mm

774

-

-

... More
32 mm

20

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

50

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.

43

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.

144

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

83

-

-

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

161

-

-

... More
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as reqd.

17

-

-

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm X 75mm)

58

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet

7

-

-

... More
Cat6 RJ45 socket outlet

51

-

-

... More
Supply & fixing of telephone tag blocks with gas tight connecton with self- cleaning 'KRONE" terminal connectors fixed in minimum 1.2mm thick powder coated, hinged, lockable door, sheet steel dust proof indoor enclosure including mounting frame and label holder including civil work such as chase cutting, fixing / concealing the box and making good as required including terminations: 10 pair tele tag block

1

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

132

-

-

... More
2 run of cable

198

-

-

... More
3 run of cable

264

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

360

-

-

... More
DISTRIBUTION BOARDS: Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 12 way (4 + 36), Double door

3

-

-

... More
Supplying and fixing 5A to 32A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

108

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

9

-

-

... More
Supplying and fixing 40 A to 63 A rating, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

3

-

-

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

9

-

-

... More
Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following trip le pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 12 way, Double door TPN MCBDB

3

-

-

... More
Supplying and fixing of 160A Four Pole MCCB, 415 V, Breaking capacity of 16 kA (Ics= 100%Icu), Compact sized Din mountable, snap fitted Moulded Case Circuit Breaker (MCCB) with inbuilt adjustable Overload settings, conforming to IS/IEC: 60947-2 and IEC 60947-2, in the Enclosure complete with connections, testing and commissioning etc. as required.

1

-

-

... More
SUPPLY OF LIGHT FIXTURES AND FANS: Note:-The model numbers specified below are only for references for Shape of the product requirement. The product shall supplied, must match the technical specifications. The technical data sheets shall be arranged before the material dispatch and got approved from engineer-in- charge. Supply of 20W 1200mm LED fitting batten light.

427

-

-

... More
Supply of 12W round surface sleek LED fitting .

113

-

-

... More
Supply of 1200mm dia of ceiling fan complete with double ball bearing, motor, blades, downrod, canopy, capacitor etc. suitable for operation on 230 volt, 50 Hz, A.C. supply complete as required.

161

-

-

... More
Supplying, installation and fixing of 250mm sweep energy saving PVC exhaust fans with low power consumption etc complete with base frame and mounting arrangement with lovers complete as required.

37

-

-

... More
INSTALLATIONS OF LIGHT FIXTURES AND FANS: Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

540

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

161

-

-

... More
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc as required.

37

-

-

... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.

738

-

-

... More
EARTHING SYSTEM: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.

2

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

35

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

30

-

-

... More
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL): Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.

84

-

-

... More
Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.

23

-

-

... More
Supplying, installation, testing & commissioning of response indicator on surface/recesss MS box having two LEDs metallic cover complete with all connections etc. as required.

99

-

-

... More
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.

23

-

-

... More
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. 6 Zone

1

-

-

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm

1080

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm

1026

-

-

... More
BUSBAR BOX BUBASR BOX-WALL MOUNTED Busbar 200Amp, 4P, 25kA, Aluminium busbars Outgoing 4 Nos. Holes in 3 phase and Neutral busbar with hardwares suitable for outgoing cable connections upto 4Cx16 Sqmm Al Arm Cable. BUBASR BOX-WALL MOUNTED as described above and shown in SLD.

1

-

-

... More
FIRE EXTINGUISHER

-

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.

23

-

-

... More
Supply, installation, testing and commissioning ISI marked (IS:15683) Fire Extinguisher, Carbon-di-oxide type capacity 4.5 Kg. Flat base including valve, discharge hose of not less than 10 mm dia, 1M long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1966 and walll suspension braket as required as per specifications.

38

-

-

... More
Supply, installation, testing and commissioning of 6kg ABC (Powder Type) Fire Extinguisher. Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 as required as per specifications.

20

-

-

... More
Underground Sump

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t All kind of Soil

81

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

3.8

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

14.16

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

5.75

-

-

... More
Reinforced cement concrete in retaining wall (any thickness) including attached pillasters, buttresses, plinth and string courses, fillets etc from top of foundation up to floor two level excluding cost of centring,shuttering and reinforcement in : a) M20 (1 cement: 1.5 Coarse Sand : 3 stone aggregate 20 mm nominal size).

35.55

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

14.5

-

-

... More
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc

392

-

-

... More
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

110.2

-

-

... More
Reinforcement of RCC work including straightening, cutting, bending, placing in position and binding all complete. a) Cold twisted bar.

6929.53

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

109.38

-

-

... More
15 mm cement plaster 1 : 4 (1 cement : 4 fine sand) on the rough side of single or half brick wall

59.4

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade

109.38

-

-

... More
Supplying and laying under layer of bitumen saturated felt type-I.

59.6

-

-

... More
Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown or/and residual bitumen applied hot @ 1.45 Kg. per Sq.m. of area for each courses, second course of roofing felt type-3 grade-I (hessian base self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea size gravel spread at 6 Cu.dm. per sqm. including preparation of surface excluding grading complete.

59.6

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb ( 225mm wide, 8-11mm thick).

38

-

-

... More
Supplying & Fixing CI Covers for manholes w/o frames, 560 mm dia (Heavy Duty), the weight of the cover to be not less then 108 kg.

4

-

-

... More
Add Carriage Charges

1

-

-

... More
Add Site Development

-

-

-

... More
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.) Girth from 300 mm to 600 mm

15

-

-

... More
Clearing Grass and Removal of Rubbish

0.2

-

-

... More
Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.)

1206.3

-

-

... More
Excavation in ordinary rock by manual means (Excavation in ordinary rock using manual means including loading in a truck and carrying of excavated material to embankment site with in all lifts and leads upto 1000 metres )

3618.9

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment)

225

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) : 2.4.1 Screened through sieve of I.S. designation 20 mm

45

-

-

... More
Rough dressing the trenched ground including breaking clods

750

-

-

... More
Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). 2.10.1 In rows 5 cm apart in both directions

495

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately)

75

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) 2.14.1 Holes 1.2 m dia and 1.2 m deep

12.96

-

-

... More
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge

50

-

-

... More
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

13.5

-

-

... More
Flooding the ground with water including making kiaries and dismantling the same

750

-

-

... More
Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge. 2.30.1 Top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cm with wall thickness of 25.4 mm

90

-

-

... More
Filling of the following size empty pots with mixture of good earth & manure in the ratio of 2:1 (Two part of Good earth & one port of manure) and placing them on approprite place i/c carriage of earth, manure and pots up to 50 mtr, as per direction of officer incharge. (The cost of good earth, earthen pots & manure will be paid seperately.) 2.31.1 Size of Empty Pots 15cm Top dia, 8cm Bottom Dia & 15cm Perpendicular height.

90

-

-

... More
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.

750

-

-

... More
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.

750

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) 2.57.1 Trees Plant

167

-

-

... More
2.57.2 Shrubs Plant

167

-

-

... More
2.57.3 Hedge Plant /Ground cover

167

-

-

... More
Providing and fixing of Tuflex Garden fencing Hexagonal net/or equivalent of green colour having contents ( Weight grams/sqm. 510 (+/- 8%)) in width of 60 cm. with bamboo of 90 cm. length. The bamboo should be painted with green colour paint of approved brand and manufacture (two or more coats) and fixed 30 cm. below ground level and 60 cm. above ground level at a distance of 1.50 mtrs. The net and bamboo should be binded with 2 mm. G.I. Wire at three places properly as per direction of Engineer-in-charge

170

-

-

... More
Removal of garden waste by TATA 407 or equivalent including loading/ unloading and carriage upto 1 km lead,complete disposal upto designated place as per direction of officer-in-charge

6

-

-

... More
Providing and displaying of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.

55

-

-

... More
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge

60

-

-

... More
Add Septic Tank (150User)

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 0.00-1.50m

134.46

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 1.50-3.00m

80.68

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.

86.06

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).

7.3

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)

20.18

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete.

12.98

-

-

... More
Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick.

55.5

-

-

... More
Edges of slabs and breaks in floors and walls. Under 20 cm wide

45.92

-

-

... More
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.

2376.2

-

-

... More
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement :4 coarse sand)

41.04

-

-

... More
62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.

36.96

-

-

... More
Cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement. 20mm cement plaster

73.72

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Square shape 450 mm internal dimension

4

-

-

... More
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

28

-

-

... More
Providing and fixing soil, waste and vent pipes 100 mm dia. Centrifugally cast (spun) iron socketed pipe as per IS: 3989.

7.2

-

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x45 cm dry brick honey comb shaft with bricks of class designation 75 and S. W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With F.P.S. bricks

2

-

-

... More
Add Carriage Charges

2

-

-

... More
Internal Road

-

-

-

... More
Granular Sub-base with Close Graded Material (Table:- 400-1) Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) (i) for grading- I Material

106.88

-

-

... More
Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.)

712.5

-

-

... More
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade.

562.5

-

-

... More
BASES AND SURFACE COURSES (BITUMINOUS): Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)

56.25

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. (ii) 80 mm thick C.C. paver block of M-30 grade with approved color design and pattern.

562.5

-

-

... More
Carrage charges

1

-

-

... More
Retaining wall

-

-

-

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) I)Ordinary soil A)Manual Means (i) Upto 3.0m.

311.8

-

-

... More
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)

32.25

-

-

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications C RCC Grade M20 Case I Using concrete mixer

252.74

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications

5.13

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification

45.95

-

-

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications

197.22

-

-

... More
Supplying of quick setting cement compound as per specification.

2031.37

-

-

... More
Carriage Charge of Material

1

-

-

... More
Boundary Wall & Entrance Gate with Guard Room

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t

46.66

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

1.96

-

-

... More
Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

3.08

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

7.2

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

0.56

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

8.7

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

5.14

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

11.16

-

-

... More
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

5.6

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

95.43

-

-

... More
e) Column, pillars, posts and struts etc.

66.35

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.

2541.8

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

1.73

-

-

... More
Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.

19.42

-

-

... More
Extra for half brick masonry in superstructure above plinth level and up to floor two level.

19.42

-

-

... More
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.

5.74

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

1.52

-

-

... More
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm

1

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 300 x 10 mm

2

-

-

... More
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm

2

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete. b) size of tiles 600x600mm

4.25

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

38.84

-

-

... More
Painting two coats with oil type wood preservative of approved brand and manufacture on new work.

4.44

-

-

... More
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.

4.44

-

-

... More
Applying one coat of distemper primer of approved brand and manufacture on wall surface.

17.53

-

-

... More
Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade

38.84

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

38.84

-

-

... More
Steel work riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. b) In Tees, Angles, Flats and Channels

8.01

-

-

... More
Add Internal Electrification

1

-

-

... More
Add Carriage Charges

1

-

-

... More
Boundary wall

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t

239.36

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

37.44

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

14.99

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

45.37

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

35.92

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

49.98

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

607.4

-

-

... More
e) Column, pillars, posts and struts etc.

478.98

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.

7527.21

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

66.53

-

-

... More
Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.

542.33

-

-

... More
Extra for half brick masonry in superstructure above plinth level and up to floor two level.

542.33

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.

3073.18

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

1412.65

-

-

... More
Applying one coat of distemper primer of approved brand and manufacture on wall surface.

1412.65

-

-

... More
Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade

1412.65

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

1412.65

-

-

... More
Add Carriage Charges

1

-

-

... More
Sub-Head: Kitchen

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning t

84.12

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

17.69

-

-

... More
Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth

2.05

-

-

... More
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.

67.37

-

-

... More
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

10.13

-

-

... More
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

0.43

-

-

... More
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

24.13

-

-

... More
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

4.7

-

-

... More
Reinforced cement concrete in chajjas exceeding 15mm in thickness upto floor two level including centring and shuttering complete but excluding the cost of reinforcement with 1 : 1.5 : 3( 1 cement: 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

0.95

-

-

... More
Reinforced cement concrete work in shelves up to floor two level excluding cost of centering and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).

0.79

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.

14.4

-

-

... More
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

11.1

-

-

... More
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

17.25

-

-

... More
d) Lintels, beams, girders, bressumers and cantilevers etc.

225.99

-

-

... More
e) Column, pillars, posts and struts etc.

62.64

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. b) Cold twisted bars.

4745.25

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

14.31

-

-

... More
Half brick masonry (with best available local bricks) in cement mortar 1:3 (1 cement : 3 coarse sand) in foundation and plinth.

138.63

-

-

... More
Extra for half brick masonry in superstructure above plinth level and up to floor two level.

138.63

-

-

... More
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.

173.76

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

7.77

-

-

... More
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws. a) 38 mm thick best available local wood, class - B I

33.79

-

-

... More
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. b) Ornamental grill.

287.19

-

-

... More
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm

4

-

-

... More
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 300 x 10 mm

8

-

-

... More
c) 150 x 10 mm

32

-

-

... More
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm

35

-

-

... More
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).

2826.71

-

-

... More
Providing corrugated G.I.sheet roofing fixed with galvanised iron J or L hooks, bolts & nuts 8 mm dia with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead complete, excluding the cost of purlins, rafters and trusses. (a) 0.63 mm thick GI sheet

262.2

-

-

... More
Providing ridges or hips 60 cm overall in plain G.I. sheet fixed with galvanised iron J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.

11.8

-

-

... More
Providing and fixing 4.0 mm thick asbestors plain sheet ceiling of approved quality with necessary nails etc.complete (frame work for base to be paid separately). First floor

91.97

-

-

... More
Providing and fixing plain, square edged wooden beading 38 mm x 12 mm section with screws of approved quality for ceiling. a) Best local approved quality wood.

91.97

-

-

... More
Extra for chamfered edges in beading

91.97

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) including grouting the joints with white cement and matching pigments etc, complete. b) size of tiles 600x600mm

91.97

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacture) with water absorption less than 0.08% and conforming to IS: 15622, of approved make , in all colours and shades, skirting, riser of steps, over 12mm thick bed of cement mortar 1:3 (1 cement : 3 course sand) including grouting the joints with white cement and matching pigments etc, complete. b) size of tiles 600x600mm

48.78

-

-

... More
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.

63.42

-

-

... More
12 mm cement plaster 1 : 4 (1 cement : 4 fine sand).

336.3

-

-

... More
Painting two coats with oil type wood preservative of approved brand and manufacture on new work.

33.64

-

-

... More
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.

33.64

-

-

... More
Applying one coat of distemper primer of approved brand and manufacture on wall surface.

99.85

-

-

... More
Painting two or more coats with enamel paint of approved brand and manufacture in any shade on new work to give even shade

99.85

-

-

... More
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work including priming coat of whiting to give an even shade.

336.3

-

-

... More
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).

12

-

-

... More
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.

50

-

-

... More
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.

1

-

-

... More
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15 mm nominal bore

28

-

-

... More
b) 20 mm nominal bore

20

-

-

... More
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 15 mm nominal bore

50

-

-

... More
b) 20 mm nominal bore

20

-

-

... More
d) 32 mm nominal bore

40

-

-

... More
Providing and fixing brass bib cock of approved quality. a)15 mm nominal bore

1

-

-

... More
Providing and fixing brass stop cock of approved quality. a) 15 mm nominal bore

8

-

-

... More
Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain in enamel led flush band, 20 mm over flow pipe with specials and mosquito proof coupling of approved municipal design complete including cutting and making good the walls and floors where required. a) WC pan with white plastic seat and lid.

1

-

-

... More
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.

5

-

-

... More
Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete.

1

-

-

... More
Providing and fixing kitchen sink including making all connection excluding cost of fittings. a) White glazed fire clay sink size 600x450x150 mm

1

-

-

... More
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.

2

-

-

... More
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes. a) 100 mm dia

10

-

-

... More
c) 50 mm dia

6

-

-

... More
Providing and fixing sand cast iron heel rest sanitary bend. a) 100 mm dia

4

-

-

... More
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. a) 100 x 100 x 100 mm

1

-

-

... More
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors. c) 100 mm inlet and 50 mm outlet

1

-

-

... More
Add Internal Electrification

1

-

-

... More
Add Carriage Charges

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.