Urban Development And Housing Department Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Urban Development And Housing Department Tender
Civil And Construction
Building Construction
Eprocure
Opening Date21 Jun 2022
Closing Date5 Jul 2022
Tender AmountRefer Documents
Costs
EMD
₹ 4,51,000Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_APUDH_780_1Bid Award Id
ViewTender No
EE/UD/JRP/PLG-01/2021-22/01Tender Authority
Urban Development And Housing Department ViewPurchaser Address
-Website
http://http://udarunachal.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Providing and laying cement concrete 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in :
a) Foundations and plinth
3.4
-
-
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
480.7
-
-
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
b) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
14.6
-
-
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
49.9
-
-
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
13.5
-
-
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement.
b) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
8.9
-
-
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation, footings, bases of columns etc. and mass concrete.
43.2
-
-
c) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
332.8
-
-
d) Lintels, beams, girders, bressumers and cantilevers etc.
135
-
-
e) Column, pillars, posts and struts etc.
138.6
-
-
Reinforcement of RCC work including bending, binding and placing in position complete.
b) Cold twisted bars.
11344.9
-
-
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
310.6
-
-
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.
a) 38 mm thick best available local wood, class - B I
62.4
-
-
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including aluminium butt hinges with necessary screws.
a) 38 mm thick best available local wood, class - B I
85.5
-
-
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.
b) Ornamental grill.
1282.9
-
-
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete.
a) 300 x 16 mm
29
-
-
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete.
a) 300 x 10 mm
74
-
-
c) 150 x 10 mm
158
-
-
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete.
a) 125 mm
226
-
-
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer welded and bolted including special shaped washers etc complete (welding to be paid separately).
138066.5
-
-
Welding by gas or electric plant including transportation of plant at site etc. complete.
7200
-
-
Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately)
(a) 0.71 mm, troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
1697
-
-
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified
a) 2 mm thick flat
160.8
-
-
Providing and fixing of Pre-coated colour or mill finish Aluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)] For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/ tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete :
a)Precoated/mill finish aluminium Ridges plain (500- 600mm)
96
-
-
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size underdeck on ceiling surface, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of 350 kPa listed as per ASTM D 1621, density of 34-36 kg/cum as per ASTM D 1622, water absorptions ? 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
1697
-
-
The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places
1252.9
-
-
Providing and fixing 50 mm thick extruded polystyrene rigid insulation board of required size between cavity wall, complying with ISO 4898:2008 & ASTM C 578-08b - type VI, having thermal conductivity of 0.0289 W/m K as per ASTM C 578 (measured as per IS 3346), compressive strength of 350 kPa listed as per ASTM D 1621, density of 34-36 kg/m³ as per ASTM D 1622, water absorptions ? 1% by volume as per ASTM D 2842, oxygen index of 24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fire retardent property as per DIN 4102, Part 1 of class B2 and as per ASTM E84 class A, fixed with suitable water based adhesive and fastener, complete in all respect as per the direction of Engineer-in-Charge.
1252.9
-
-
Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC), with necesasary profiled edges fixed with 40mm SS screws 5 nos in each tile to frame work made of second class teak wood of size 20x15 mm in centre of each tile and bottom and top of work height, 40x15mm placed at ends of each tile. The cladding shall be laid over backlayment of 1.00 mm thick expanded polyethylene foam of density 40kg/cum in two layers, first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
1252.9
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 1000x1000 mm
416.2
-
-
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
123.7
-
-
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with Second class deodar wood
246.5
-
-
Painting two coats with oil type wood preservative of approved brand and manufacture on new work.
239.1
-
-
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
239.1
-
-
Making plinth protection with 2nd class bricks on edge in cement mortar 1 : 6 (1 cement : 6 fine sand) over 7.50 cm bed of dry bricks aggregate 40 mm nominal size rammed consolidated and grouted with fine sand and the top of bricks pointed with cement mortar 1 : 2 (1 cement : 2 fine sand).
135
-
-
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
600
-
-
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
170
-
-
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
1
-
-
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work).
a) 15 mm nominal bore
54
-
-
b) 20 mm nominal bore
180
-
-
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work).
a) 15 mm nominal bore
768
-
-
b) 20 mm nominal bore
450
-
-
d) 32 mm nominal bore
360
-
-
Providing and fixing brass bib cock of approved quality.
a)15 mm nominal bore
25
-
-
Providing and fixing brass stop cock of approved quality.
a) 15 mm nominal bore
15
-
-
Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet.
a) 100 mm dia
9
-
-
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvanized steel telescopic flush pipe with fittings and clamps 20 mm GI over flow pipe with specials and mosquito proof coupling of approved municipal design and GI chain and pull complete including painting of cistern and fittings, cutting and making good the walls and floors where required.
a) Long Pan patten WC Pan
6
-
-
Providing and fixing white vitreous china pedestal type (European type WC pan) water closet with seat and lid with CP brass hinges and rubber buffers, 12.5 Litres white vitreous china low-level flushing cistern with fittings and brackets 40 mm white porcelain in enamel led flush band, 20 mm over flow pipe with specials and mosquito proof coupling of approved municipal design complete including cutting and making good the walls and floors where required.
a) WC pan with white plastic seat and lid.
6
-
-
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required.
b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
6
-
-
Providing and fixing a pair of white vitreous china foot rest of standard pattern for squatting pan WC.
a) 250 x 130 x 30 mm
6
-
-
Providing and fixing 12.5 litres high level CI flushing cistern of approved make with integral fittings such as ball valve, bell, lever, GI chain and pull complete.
12
-
-
Providing and fixing 100 mm sand cast iron grating for gulley, floors or nahni trap.
12
-
-
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.
a) 100 mm dia
110
-
-
c) 50 mm dia
28.8
-
-
Providing and fixing sand cast iron heel rest sanitary bend.
a) 100 mm dia
15
-
-
Providing and fixing sand cast iron single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete.
a) 100 x 100 x 100 mm
2
-
-
Providing and fixing sand cast iron trap of self cleansing design with sand cast iron screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors.
c) 100 mm inlet and 50 mm outlet
4
-
-
Add 12.5% for internal electrification
1
-
-
Add Carriage Charges
1
-
-
DISMANTLING PORTION
-
-
-
Demolishing cement concrete 1 : 3 : 6 or richer mix including disposal off material within 50 metres lead.
14
-
-
Demolishing RCC work including stacking of steel bars and disposal of unserviceable materials within 50 metres lead.
88
-
-
Demolishing brick work in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
63
-
-
Extra for cutting reinforcement bars in RCC or RB work.
707.2
-
-
Taking out doors, windows and clerestory windows shutters (steel or wood) including stacking within 50 m lead.
28
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutters including chowkhats, architrave, hold fasts etc complete and stcking within 50 m lead.
Of area 3 sq. metres and below
28
-
-
Dismantling wood work of sectional area 40 Sq.cm. and above wrought, framed and fixed in frames, other frames and trusses including stacking the material within 50 m lead. Of sectional area below 40 square centimetres
1.1
-
-
Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 m lead. b) For thickness of tiles above 25 mm and up to 40 mm
819
-
-
Dismantling dry brick pitching in floors, drains etc including stacking of serviceable material and disposal of unserviceable material within 50 m lead.
134.9
-
-
Dismantling GI sheet roofing including ridges, hips, valleys and gutters etc and stacking the material within 50 m lead.
579.6
-
-
Dismantling steel work in built up section excluding dismembering and stacking within 50 m lead.
30
-
-
Extra for dismantling trusses, rafters, purlins etc of steel work for every additional span of one metre or part thereof beyond 10 m.
30
-
-
Dismantling asbestos sheet roofing including ridges, hips, valleys and gutters stacking the material within 50 m lead.
579.6
-
-
SH: Septic Tank for 150 users
-
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 0.00-1.50m
67.2
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) I manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil. 1.50-3.00m
40.3
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
43
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
3.7
-
-
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
10.1
-
-
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns, etc. for mass concrete.
6.5
-
-
Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick.
27.8
-
-
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
23
-
-
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Thermo-Mechanically Treated bars.
1188.1
-
-
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in:
Cement mortar 1:6 (1 cement :4 coarse sand)
20.5
-
-
62 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
18.5
-
-
Cement plaster 1:4 (1 cement: 4 coarse sand) finished with a floating coat of neat cement. 20mm cement plaster
36.9
-
-
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
Square shape 450 mm internal dimension
2
-
-
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
14
-
-
Providing and fixing soil, waste and vent pipes 100 mm dia. Centrifugally cast (spun) iron socketed pipe as per IS: 3989.
3.6
-
-
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x45 cm dry brick honey comb shaft with bricks of class designation 75 and S. W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design
With F.P.S. bricks
1
-
-
Carring charges for building metirials by mechanical means
1
-
-
MS STEEL GATE:-
-
-
-
Earth work in excavation in foundation and trenches etc. in all kinds of soil containing 50% or more of shingle or small size boulders upto 30cm size , saturated soil and rock), lift upto 1.5 m and stacking the excavated soil not more than 3m clear from the edge of the excavation and returning the stacked soil in 15cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
7.5
-
-
Providing and laying cement concrete 1:4:8 (1 cement:4 course sand: 8 graded stone, aggregate 40mm nominal excluding the cost of centering and shuttering a) Foundation and plinth
0.8
-
-
Reinforcement of RCC work including bending, binding and placing in position complete.
244.3
-
-
Centring and shuttering including strutting, propping etc and removal of form work for :
a) Foundation, footings, bases of columns etc. and mass concrete
2.6
-
-
b) Column, pillars, posts and struts etc.
9.3
-
-
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
b) 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
0.2
-
-
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 ement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring,shuttering and reinforcement.
1.2
-
-
c) 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
20 mm cement plaster 1 : 4 (1 cement : 4 fine sand).
7
-
-
Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
21.1
-
-
Steel work in single section including cutting, hoisting, fixing in position and applying a primming coat of red lead paint in tees, angles and channels
b) In Tees, Angles and Channels
11
-
-
Applying priming coat with ready mixed primer of approved brand and manufacture on steel work.
39
-
-
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
39
-
-
Add for cost of Carriage=