Public Works Department Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Public Works Department - PWD Tender
Civil And Construction
Road Construction
Eprocure
Opening Date11 Oct 2024
Closing Date25 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 6,74,558Document Cost
₹ 5,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_PWDAP_1963_1Bid Award Id
ViewTender No
No. SGMD/eNIT/SGM/2024-25/003Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://arunachalpwd.org
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
SH : RCC Retaining wall, 4.00 mtr Height
-
-
-
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling the excavation earth to the exlent required and utilising the remaining earth locally for road work.)
Ordinary soil Manual Means (Depth upto 3 m)
548.05
10
-
PCC 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crusged stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
43.91
10
-
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications RCC Grade M20 (Height up to 5 m)
30.68
10
-
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications
2.02
10
-
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
31
10
-
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification
A. Granular material
19.52
10
-
SH : B/ wall 10.00 mtr length & 3.80 mtr Height
-
-
-
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Ordinary soil Manual Means (Depth upto 3 m)
30.78
10
-
PCC 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crusged stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
3.42
10
-
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications. Random Rubble Masonry
23.33
10
-
Dry Rubble flooring
25.69
10
-
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification
A. Granular material
6.88
10
-
SH :RCC Slab Culvert 1.00 mtr Span 1.50 mtr Height
-
-
-
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
I. Ordinary soil
A.Manual Means
i. upto 3 m depth
95.88
10
-
PCC 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crusged stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
22.8
10
-
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications.
Coursed Random Rubble Masonry(first Short)
61.84
10
-
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
PCC Grade M20
Height upto 5m
0.54
10
-
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification
RCC Grade M20
Using Concrete Mixer
For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m
2.72
10
-
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
0.54
10
-
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
36
10
-
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification
A. Granular material
4.13
10
-
SH- RCC Steel Composit Bridge
-
-
-
(SH:Sub-Structure)
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Ordinary soil
Manual Means (Depth 3-6 m)
504
10
-
Ordinary rock (not requiring blasting)
Manual Means (Depth upto 3 m)
504
10
-
Hard rock (requiring blasting)
Manual Means
252
10
-
PCC 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crusged stone aggregate 40mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
36.48
10
-
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications. As pe detail attached Annexure-RB
21.64
10
-
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
RCC Grade M25
Height upto 5m using concrete mixer
326.45
10
-
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications
RCC Grade M30
Height upto 10m using concrete mixer
20.06
10
-
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification
A. Granular material
1046.15
10
-
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.
213.85
10
-
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
236
10
-
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
244800
10
-
(SH:Super Structure)
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification.
C.RCC Grade M30
Case-I:Using Concrete Mixer
i. For solid slab super-structure, 20-30% of (a+b+c) r.Height above 10m
22.5
10
-
E.PSC Grade M-40
Case-I:Using concrete mixer.
i. For solid slab super-structure, 20-30% of (a+b+c)
q.Height 5m to 10m
21
10
-
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
15.6
10
-
M30 Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification
15.6
10
-
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
4.36
10
-
Elastomeric Slab Steel Expansion Joint (Providing and laying of an elastomeric slab steel expansion joint, catering to right or skew (less than 20 deg., moderately curved with maximum horizontal movement upto 50 mm, complete as per approved drawings and technical Specifications.
14
10
-
Drainage Spouts complete as per drawing and Technical specification
15
10
-
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications
8.44
10
-
Structural steel work such as bearing plate, 100mm Ø steel tube & HT bolt 50mm Ø as per direction of Engineer incharge and drawing.(Steel work similar to item 12.10 for cutting edge has been consicerded for rate)
At crash barrier pipe rail hoisting and placing etc
0.9
10
-
Supply and fabrication of steel work at Fabricators workshop comprising of Main Girders, Cross Girders, Connecting plates, stringer, stiffening plates etc. and delivered at bridge site in undamaged condition including straightening, descaling, degreasing, cutting to size and shape, drilling, welding and grinding, supply of all MS/HTS shop or site bolts, nuts & washers, holding down bolts and nuts etc., trial assembling at workshop, one priming coat of shop paint with red lead paint conforming to IS-102 with all labour, material, cost of paints, consumables, etc. complete as per specification and as directed by the Engineer-in-Charge
27
10
-
Taking delivery of fabricated steelwork, leading to and at site as necessary, assembling and erection of fabricated steel structure to proper line , level and camber as per approved drawings complete in all respect including transportation and handling in and specification including supply of all fasterners, painting of all exposed surfaces of steelwork after erection with one site coat of red lead to IS-102 and two coats Alumunimium paint to IS-2339, grouting of anchor bolts in position, including all labour, consumables, materials, machinery, tools and tackles complete as per specification and as directed by the Engineer-in-Charge
Case-I:Up to 40m single span or in multiples
27
10
-
Evaluation Notes How It Works ?
Potential Partner