Public Works Department Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Public Works Department - PWD Tender

Civil And Construction
Road Construction
Eprocure
Opening Date2 Dec 2022
Closing Date16 Dec 2022
Tender Amount₹ 20,01,91,537 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
ii. Girth from 600 mm to 900 mm

20

-

-

... More
iii. Girth from 600 mm to 900 mm

10

-

-

... More
Clearing and Grubbing Road Land . (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used orauctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness

-

-

-

... More
i. In area of light jungle

23100

-

-

... More
ii. In area of thorny jungle

9000

-

-

... More
II. FORMATION CUTTING

-

-

-

... More
Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres)

137917.2

-

-

... More
Deduct for quantum of earthwork of all types disposal directly by throwing into the valley without involving any lead and lift (Ordinary and Hard Soil/Hard Shale, Soil containing shingle or small size boulders.

68958.6

-

-

... More
Excavation in Hilly Area in Ordinary Rock by Mechanical Means not Requiring Blasting. (Excavation in hilly area in ordinary rock not requiring ballasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres )

42433.53

-

-

... More
Deduct for quantum of earthwork of all types disposal directly by throwing into the valley without involving any lead and lift. (Ordinary and Hard Rock)

-

-

-

... More
Ordinary and Hard Rock

21216.77

-

-

... More
Excavation in Hilly Areas in Hard Rock Requiring Blasting (Excavation in hilly areas in hard rock requiring blasting, by techanical means including trimming of slopes and disposal of cut material with all lifts and lead upto 1000 metres.)

4762.92

-

-

... More
Deduct for quantum of earthwork of all types disposal directly by throwing into the valley without involving any lead and lift. (Ordinary and Hard Rock)

-

-

-

... More
Ordinary and Hard Rock

2381.46

-

-

... More
III. GSB layer

-

-

-

... More
Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.)

38272.5

-

-

... More
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and re-rolling the sub grade.

38272.5

-

-

... More
Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401)

-

-

-

... More
for grading- I Material

4429.69

-

-

... More
IV. WBM-II

-

-

-

... More
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)

-

-

-

... More
Using Scrining Crushable type such as Moorum or Gravel

5315.63

-

-

... More
V. WBM-III

-

-

-

... More
Water Bound Macadam (Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density.)

-

-

-

... More
Grading- III Using Scrining Type-B (11.2mm agg.)

5315.63

-

-

... More
VI. SDBC

-

-

-

... More
Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.)

35437.5

-

-

... More
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.

35437.5

-

-

... More
MORTH - 504 IRC: SP : 100 - 2004, chapter 7.2 Using Cold Mix Binder (Exceeds IS 8887 : 2004 of SS-2)Providing, laying of Semi Dense Bituminous Concrete with 100-120 TPH HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading (9.5 mm nominal size), premixed with cold mix binder @ 7.5% by weight of mix, transporting the coldheeled, vibratory and tandem rollers to achieve the desired compaction (Application: Cold BM as per Designmix & Implementation by manufacturer's discretion only)

1771.88

-

-

... More
VII. BOX CULVERT (1.50 x 1.50)

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)

-

-

-

... More
Ordinary soil

-

-

-

... More
Manual Means

-

-

-

... More
Depth above 6 m (without de-watering)

235.53

-

-

... More
Ordinary Rock (not requiring blasting)

-

-

-

... More
Manual Means

-

-

-

... More
Depth upto 3 m (without de-watering)

549.57

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.

-

-

-

... More
PCC Grade M15

62.81

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications

-

-

-

... More
RCC Grade M20

227.04

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

38.24

-

-

... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications

168

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

321.6

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification

-

-

-

... More
A Sandy material

977.4

-

-

... More
VIII. BOX CULVERT (2.00 x 2.00)

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)

-

-

-

... More
Ordinary soil

-

-

-

... More
Manual Means

-

-

-

... More
Depth above 6 m (without de-watering)

163.84

-

-

... More
Ordinary Rock (not requiring blasting)

-

-

-

... More
Manual Means

-

-

-

... More
Depth upto 3 m (without de-watering)

382.29

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.

-

-

-

... More
PCC Grade M15

33.47

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications

-

-

-

... More
RCC Grade M20

108.6

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

25.71

-

-

... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications

80

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

155

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification

-

-

-

... More
A Sandy material

351.5

-

-

... More
IX. BOX CULVERT - (4.00X4.00)

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)

-

-

-

... More
Ordinary soil

-

-

-

... More
Manual Means

-

-

-

... More
Depth above 6 m (without de-watering)

100.58

-

-

... More
Ordinary Rock (not requiring blasting)

-

-

-

... More
Manual Means

-

-

-

... More
Depth upto 3 m (without de-watering)

234.68

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.

-

-

-

... More
PCC Grade M15

22.88

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications

-

-

-

... More
RCC Grade M20

95.8

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications.

14.43

-

-

... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications

18

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

61.4

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification

-

-

-

... More
A Sandy material

139.35

-

-

... More
X. CC DRAIN

-

-

-

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material with de-Watering..)

-

-

-

... More
Ordinary soil

-

-

-

... More
Manual Means

-

-

-

... More
upto 3 m depth

825

-

-

... More
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 20 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)

150

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications

-

-

-

... More
CC Grade M15

360

-

-

... More
Plastering with cement mortar (1:3 ) on masonry work in sub-structure as per Technical Specifications

2400

-

-

... More
XI. RRM WALL

-

-

-

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)

-

-

-

... More
Ordinary soil Manual Means, Depth upto 3m

40.8

-

-

... More
Ordinary rock [not reqoiring blasting] Manual Means

163.2

-

-

... More
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)

40.8

-

-

... More
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications

-

-

-

... More
Random Rubble Masonry

394.2

-

-

... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. specifications

120

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification.

360

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification

-

-

-

... More
A) Sandy material

720

-

-

... More
Plastering with cement mortar (1:3 ) on masonry work in sub-structure as per Technical Specifications

438.3

-

-

... More
MINOR BRIDGE-20.00 M SPAN

-

-

-

... More
XIII. ABUTMENT

-

-

-

... More
Excavation for Structures

-

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)

-

-

-

... More
Ordinary soil

-

-

-

... More
Manual Means

-

-

-

... More
Depth upto 3 m (without de-watering)

168.1

-

-

... More
Ordinary Rock (not requiring blasting)

-

-

-

... More
Manual Means

-

-

-

... More
Depth upto 3 m (without de-watering)

168.1

-

-

... More
Hard Rock ( blasting prohibited )

-

-

-

... More
Mechanical Means (without de-watering)

84.05

-

-

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications.

-

-

-

... More
PCC Grade M15

179.52

-

-

... More
RCC Grade M25

-

-

-

... More
Using concrete Mixer

92.73

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications.

-

-

-

... More
RCC Grade M25

124.8

-

-

... More
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications

-

-

-

... More
Random Rubble Masonry

467.45

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

48

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification

-

-

-

... More
A Sandy material

128

-

-

... More
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.

100

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and technical specifications.

9.39

-

-

... More
DECK SLAB

-

-

-

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing & Specification.

-

-

-

... More
RCC M50

153.42

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing & specifications.

13.55

-

-

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209.

10

-

-

... More
Burried Joint (Providing and laying a burried expansion joint, expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide galvanised wieldable structural steel plate as per IS: 2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia. 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, all as specified in clause 2604.)

36

-

-

... More
Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-20 grade concrete with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified.

40

-

-

... More
Bearing (PTFE sliding plate bearing assembly of 80 tonnes )

75

-

-

... More
Excavation for Structures

-

-

-

... More
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material (without de-watering)

-

-

-

... More
Ordinary soil

-

-

-

... More
Mechanical Means

-

-

-

... More
Depth upto 3 m (without de-watering)

81.76

-

-

... More
Ordinary Rock (not requiring blasting)

-

-

-

... More
Mechanical Means

-

-

-

... More
Depth upto 3 m (without de-watering)

327.04

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.

-

-

-

... More
PCC Grade M15

11.68

-

-

... More
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.

-

-

-

... More
RCC Grade M20

5.46

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications

-

-

-

... More
RCC Grade M25

112

-

-

... More
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in sub-structure complete as per Drawing and Technical Specifications.

3.73

-

-

... More
Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical Specifications

20

-

-

... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.

84

-

-

... More
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification

-

-

-

... More
A Sandy material

210

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.