Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Eprocure
Opening Date23 Jun 2020
Closing Date17 Aug 2020
Tender Amount₹ 36,71,66,000
Costs
EMD
₹ 73,43,000Document Cost
₹ 15,000Tender Fee
Refer Documents
Summary
Bridge Point To Parsi Parlo Co Hq
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2020_CEAR_95328_1Bid Award Id
ViewTender No
AR1402039Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
c] Back Pillar.
1951
-
-
... More
d] Job Pillar
312
-
-
... More
EARTHWORK IN ROAD FORMATION,Drain ( Cross section as per IRC SP-20-2002 -RRM , Page 113 , Fig. 6.2.c )
-
-
-
... More
Earthwork in excavation in soil n hilly area by mechanical means including cutting and trimming of sides slopes and disposing of excavated earth with a lift upto 1.5m and a lead upto 20m as per Technical Specification clause 1603.1
137751.27
-
-
... More
Excavation in ordinary rock using mechanical means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
101320.15
-
-
... More
Excavation in Hard rock in hilly area requiring blasting , by mechanical means, and disposal of excavated rock asper Clause 1603.2. a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
13383.61
-
-
... More
Hume Pipe Clvt. 1000 mm dia.TYPE-I ,CD-1.5 m Span,CD-2.00 m Span,(As per IRC SP-20-2002 & SP :48-1998), Sausage wire crated boulder Protection Structure(Retaining Wall-3.00 mtr height) & Breast wall - 2.00 mtr high ( As per IRC SP-20-1979), C.C Side Drain [Trapizoidal Shape & V- Shape]( Cross section as per IRC SP-20-2002 -RRM , Page 113 , Fig. 6.2.c ),Guard Post.
-
-
-
... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
8088.12
-
-
... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
343.82
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 [P.C.C. grade M 20 Nominal mix (1:2:4)]
38.4
-
-
... More
Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ]
-
-
-
... More
Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
79.61
-
-
... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 [In 1:4 cement mortar]
800.66
-
-
... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia]
120
-
-
... More
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
41.48
-
-
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]
1162.46
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
2155.5
-
-
... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
245.9
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20]
68.48
-
-
... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
16.72
-
-
... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
2439.96
-
-
... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
1540.72
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (R.C.C grade M 20)
216.36
-
-
... More
Providing plain concrete for curtain walls complete as per drawings and technical specifications Clause 1303.3(PCC grade M10)
19.44
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
-
-
-
... More
a) For nominal mix 1:2:4[hand mixing]
10.37
-
-
... More
Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
-
-
-
... More
a) MS Deformed Bars
6.73
-
-
... More
Providing and laying boulder apron laid in wire creates with 4mm dia GI wire conforming to IS:280 and IS:4826 in 100mmx100mm mesh(Wooven diagonally)including 10 per cent extra for laps and joints laiad with stone boulders weighing not less than 25 kg each as per drawing and technical specification Clause 1301.
157.5
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]
972.15
-
-
... More
Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]
2056.71
-
-
... More
Cement plaster 15 mm thick 1:4 on stone masonry
1290.4
-
-
... More
RCC M 20 gradeProviding concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807. 1202 and 1204
140.3
-
-
... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
917.13
-
-
... More
Pavement
-
-
-
... More
SHOULDER
-
-
-
... More
Construction of subgrade and earthen shoulders with approved material obtained from way cutting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
12176.17
-
-
... More
Compacting Original ground supporting sub grade:-
-
-
-
... More
Loosining of the ground upto the level of 300mm below the subgrade level , watered, graded and compacted in layers to meet requirement of Table 300.1 and 300.2 for subgrade construction as per technical specification clause 303.5.2.
60396.89
-
-
... More
Sub-Base
-
-
-
... More
Sub-base (100 mm thick ) for ANT stablizer
-
-
-
... More
Stabilized Sub-base : Providing, mixing, laying and compacting chemically Stabilised sub base layer using all plant & equipment having IRC accredited ANT Stabiliser/Technology along with 2.5% cement and with or without 25% aggregates. Rates include all material, labour, hire charges of machinery etc. as per MoRD specifications & direction of Engineer-in-Charge.
1945.53
-
-
... More
Granular Sub-base with Well Graded Material ( Clause Table 400.2) Grade-B :- For Conventional
-
-
-
... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Drawing and Technical Specificateion Clause No 401[Gravel/Soil-Aggregate Base (Table 400.2) Grading - B]
31093.11
-
-
... More
BASE Course
-
-
-
... More
BASE COURSE ( 100 mm thick):- for ANT Stablizer
-
-
-
... More
Stabilized Base: Providing, mixing, laying and compacting chemically Stabilised base layer using all plant & equipment having IRC accredited ANT Stabiliser/Technology along with 5% cement and with or without 25% aggregates. Rates include all material, labour, hire charges of machinery etc. as per MoRD specifications & direction of Engineer-in-Charge.
1942.73
-
-
... More
WBM 3 FOR BASE COURSE ( 75 mm thick) for Conventional
-
-
-
... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(a)By Manual means.
9763.34
-
-
... More
PRIME COAT
-
-
-
... More
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 [Low porosity]
149139.38
-
-
... More
Tack coat
-
-
-
... More
Providing and applying Tack Coat with Bitiminous [RS - I] using emulsion distrubuter @ 0.25 to 0.30 Kg per Sqm. On prepared dry and hungry bituminus surface clean with hydraulic broom as per technical specification 503.
149605.14
-
-
... More
Open Graded Premix Carpet 20mm thickness
-
-
-
... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates using CBR-bitumen Cold mix binder (Tallor made) to requires line grade and level to serve as wearing course on a previously prepared base,including mixing in a suitable plant, laying and rolling with a tree wheel 80-100 KN static roller capacity. fininshed to required level and grades to be follwed by seal coat. (Application: CRRI-Bitchem Cold OGPC as per Designmix & Implementation by Manufacture's discretion only MoRD:508,2;IRC:SP: 100-2014,chapter 6.5 Using CRRI-Bitchem Cold Mix Binder.
149605.14
-
-
... More
Seal Coat :-
-
-
-
... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 By Manual Means. Type-A [Bitumen Emulsion(S-S)]
149605.14
-
-
... More
Road Furniture:-
-
-
-
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
-
-
-
... More
a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)
39
-
-
... More
b) 5th Km. Stone (size 107.50x58x25cm)
7.8
-
-
... More
c) 200m stone (precost)
195
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
70.2
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
70.2
-
-
... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
... More
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
78
-
-
... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
234
-
-
... More
Providing and Fixing PMGSY Logo Board at starting point
-
-
-
... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint.
1
-
-
... More
Providing and Fixing Title information Board of PMGSY Project(RCC)
-
-
-
... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
2
-
-
... More
Providing and Fixing Citizen information Board of PMGSY Project(RCC)"A"
-
-
-
... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
3
-
-
... More
Safety Devices and Signs in Construction Zones
-
-
-
... More
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001.
-
-
-
... More
Men at work
4
-
-
... More
Diversion
4
-
-
... More
Road closed
4
-
-
... More
Stop
4
-
-
... More
Slow
4
-
-
... More
Speed limit
4
-
-
... More
Routine Maintenance
-
-
-
... More
First Year
-
-
-
... More
Second Year
-
-
-
... More
Third Year
-
-
-
... More
Fourth Year
-
-
-
... More
Fifth Year
-
-
-
... More
GST
-
-
-
... More
Add GST @ 12%
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements