Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Road Construction
Eprocure
Opening Date4 Jul 2024
Closing Date22 Jul 2024
Tender Amount₹ 33,45,43,000
Costs
EMD
₹ 66,90,860Document Cost
₹ 15,000Tender Fee
Refer Documents
Summary
L028- 0.15 Km Pt Of Nampe-sario Rd To Warriam Via Parte Sullung.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEAR_135192_1Bid Award Id
ViewTender No
AR0301075Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Formation Cutting
-
-
-
Hill Area :- Road Formation Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
526390.5
-
-
CC Side Drain
-
-
-
CC Side Drain Earthwork in excavation for structures as per drawing and technical specification Clause 305. i) Plain Cement Concrete M10 grade
51.38
-
-
Stone masonry in cement mortar 1:5
145.58
-
-
Unlined Trapezoidal Side Drain
-
-
-
(b) Unlined Trapezoidal Side Drain Surface Drains in Ordinary Rock (Construction of unlined surface drain of average cross sectional area 0.4 sqm in ordinary rock to specified lines, grades, levels and dimensions as per approved design and to the requirement of clause 301 to 309. Excavated material to be used in embankment at site.) i) Mechanical Means
5832.51
-
-
Pavement
-
-
-
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirementof Table 300.2 with lead upto 1000 m as per
Technical Specification Clause 303.1.
26278.43
-
-
Earthen Shoulder Construction of Subgrade and Earthen Shoulders
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
6999.01
-
-
Granular Sub-Base Construction of gravel/soil-aggregate base by providing well graded material, spreading in uniform layers with motor grader on prepared surface,mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller to achieve the desired density, complete
11023.44
-
-
WBM Grading 3
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
(B) By Mechanical Means
5103.44
-
-
Prime Coat Providing and applying of prime coat with bitumen emulsion (SS-1) on prepared surface of granular base i/c clearing of base surface and spraying emulsion at the rate of 1.2 - 1.5 kg per sqm. using mechanical means as per technical specification clause 502 (high porosity)
68045.91
-
-
Tack Coat Providing and applying tack coat with Bitumen emulsion (CRS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
68045.91
-
-
Mix Seal Surfacing Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509
68045.91
-
-
Cross Drainage
-
-
-
Cross Drainage Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side I. Ordinary Soil Upto 3 m depth.
6092.09
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I). P.C.C grade M 10 Nominal mix 1:3:6
802.85
-
-
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. II) Coursed Rubble Masonry (2nd sort) In 1:4 Cement mortar.
1774.62
-
-
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 II) Coursed Rubble masonry (2nd Sort) (iii) In cement mortar (1:5)
1179.56
-
-
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Granular material
803.03
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
1348
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 m. III) R.C.C. grade M 20 Nominal 1:2:4
89.03
-
-
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
334
-
-
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I) R.C.C grade M 20 Nominal mix 1:2:4
13.33
-
-
Providing & laying reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800,1205.4 and 1205.5 RCC Grade - M -25
216.02
-
-
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
21.91
-
-
Protection Works
-
-
-
Protection Works Excavation for Structures
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Ordinary soil Upto 3 m depth
1349.19
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
P.C.C grade M 10 Nominal mix 1:3:6 Wall Base
355.05
-
-
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204
In cement mortar (1:3) Random rubble masonry
1629.55
-
-
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8(I) Granular material
1194.02
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
877
-
-
Roads Furnitures
-
-
-
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 i) Ordinary 1 km Stone (Size-66x35x25 cm)
17.4
-
-
b) 5th Km. Stone (size 107.50x58x25cm)
3.48
-
-
c) 200m stone (precost)
87
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
31.32
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
31.32
-
-
Providing and fixing of typical VVP informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
34.8
-
-
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
104.4
-
-
Providing and fixing of typical VVP Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint.
1
-
-
Providing and fixing of typical VVP Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
2
-
-
Providing and fixing of typical VVP Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
3
-
-
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001. i) Diversion
4
-
-
ii) Road closed
4
-
-
iii) Stop
4
-
-
iv) Slow
4
-
-
v) Speed Limit
4
-
-
Routine Maintenance
-
-
-
First Year
-
-
-
Second Year
-
-
-
Third Year
-
-
-
Fourth Year
-
-
-
Fifth Year
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements