Pradhan Mantri Gram Sadak Yojana Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Road Construction
Eprocure
Opening Date3 Oct 2023
Closing Date17 Oct 2023
Tender Amount₹ 10,15,50,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Granular Sub-base with Well Graded Material (Table 400.1) Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For Grading I Material

1177.81

-

-

... More
Cement treated Base Course (CTB) Cement Treated Base (CTB) : Providing, laying and spreading soil on a prepared sub-grade, pulverising, adding the designed quantity of cement to the spread soil, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-base/base as per Technical Specification Clause 404. (Cement Treated Base (CTB) with 75% local & 25% borrow materials (a) For 5% quantity of cement by weight of soil)

5281.67

-

-

... More
Prime coat. Providing and applying primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90- 1.2 kg/sqm using mechanical means as per Technical Specification Clause 502.

42253.34

-

-

... More
Item : Tack Coat. Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

42253.34

-

-

... More
Mix Seal Surfacing Mix Seal Surfacing : Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509 -(Mix Seal Surfacing (MSS) with 5 % waste Plastic -Mechanical Means.Type B (VG-10))

42253.34

-

-

... More
Item : Hume Pipe Clvt. 1000 mm dia.TYPE-I (As per IRC SP-20-2002 & SP :48-1998) = 18 Nos Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

340

-

-

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

18.59

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. (a) P.C.C. grade M 20

8

-

-

... More
Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ] a) Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i) Nominal mix (1:2.5:5)

16.59

-

-

... More
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109. (a) In 1:4 cement mortar

166.81

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106. (a) 1000 mm dia

32.5

-

-

... More
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301

8.64

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 . a) Granular material

111.46

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

80

-

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

51.23

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20]

14.27

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

1.15

-

-

... More
Item : Slab Culvert 1.50 mtr. span, 3.13 mtr high (As per IRC SP-20-2002) = 12 Nos Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

1049.28

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) i) Nominal mix 1:3:6

131.16

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:3 cement mortar

330.11

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:4 cement mortar

414.05

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

112.2

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

532

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Nominal mix

37.63

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25)

68.7

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ), Nominal mix (1:2:4)

10.08

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5, R.C.C grade M 20, a) For nominal mix 1:2:4[hand mixing]

5.38

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

4.86

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(P.C.C grade M10), Nominal mix 1:3:6

165.01

-

-

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3

79.38

-

-

... More
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5, Random rubble masonry in case of stone pitching laid with cement mortar (1:5)

102.38

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9, Sand filling

185.11

-

-

... More
Item : Slab Culvert 2.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002) = 3 Nos Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

95.71

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) i) Nominal mix 1:3:6

9.57

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:3 cement mortar

63.03

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:4 cement mortar

40.88

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

9.59

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

38

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Nominal mix

2.83

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25)

6.17

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ), Nominal mix (1:2:4)

0.72

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5, R.C.C grade M 20, a) For nominal mix 1:2:4[hand mixing]

0.38

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

0.45

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(P.C.C grade M10), Nominal mix 1:3:6

13.96

-

-

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3

6.51

-

-

... More
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5, Random rubble masonry in case of stone pitching laid with cement mortar (1:5)

7.74

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9, Sand filling

20.89

-

-

... More
Item : Slab Culvert 4.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002) = 1 Nos Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

174.1

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) i) Nominal mix 1:3:6

15.76

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:3 cement mortar

97.2

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:4 cement mortar

79.18

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

30.54

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

48

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Nominal mix

3.01

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25)

13.68

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ), Nominal mix (1:2:4)

0.96

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5, R.C.C grade M 20, a) For nominal mix 1:2:4[hand mixing]

0.38

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

0.86

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(P.C.C grade M10), Nominal mix 1:3:6

28.18

-

-

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3

16.59

-

-

... More
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5, Random rubble masonry in case of stone pitching laid with cement mortar (1:5)

13.49

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9, Sand filling

17.15

-

-

... More
Item : Slab Culvert 6.00 mtr. span, 6.00 mtr high (As per IRC SP-20-2002) = 1 Nos Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

211.17

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) i) Nominal mix 1:3:6

20.86

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:3 cement mortar

136.61

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, [I] Coursed rubble masonry (2nd sort), (i) n 1:4 cement mortar

95.93

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

28.51

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

60

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Nominal mix

3.41

-

-

... More
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25)

23.15

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ), Nominal mix (1:2:4)

0.96

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5, R.C.C grade M 20, a) For nominal mix 1:2:4[hand mixing]

0.38

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

1.59

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(P.C.C grade M10), Nominal mix 1:3:6

34.39

-

-

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3

29.75

-

-

... More
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5, Random rubble masonry in case of stone pitching laid with cement mortar (1:5)

16.68

-

-

... More
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9, Sand filling

37.65

-

-

... More
Item : 2.00 mtr High Breast wall ( As per IRC :48)) Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I] Ordinary Soil, (i) Upto 3 m depth

424.13

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. (II) Coursed rubble masonry (2nd sort), (ii) In 1:4 cement mortar

296.76

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. (II) Coursed rubble masonry (2nd sort), (i) In 1:3 cement mortar

820.85

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

435

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

370.84

-

-

... More
Item : Sausage wire crated boulder Protection Structure Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

54

-

-

... More
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. ( Based on SDB Rural Road Chapter-14, Item No.14.2)

337.5

-

-

... More
V - Shaped Side Drain & Trapezoidal Drain ( As per IRC SP-48-1998 Hill Road Manual Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, P.C.C grade M 10 a) Nominal mix 1:3:6

104.18

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204, III Random rubble masonry, iii In cement mortar (1:5)

219.38

-

-

... More
Construction of hill side drain in accordance with the requirement of specifications true to lines and grades. Dimesions and other particulars as per drawing and Technical Specification Clause 1606.1, (v) Cement plaster 15 mm thick 1:4 on stone masonry

1593

-

-

... More
Item : Road Furniture Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

-

... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001. a) Traffic sign ahead

4

-

-

... More
b) Men at work

2

-

-

... More
c) Loose chippings

1

-

-

... More
d) Do not enter

2

-

-

... More
e) Road closed

2

-

-

... More
f) Stop

2

-

-

... More
g) Slow

32

-

-

... More
h) Speed limit

8

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 i] 5th Kilometre Stone (precast)

1

-

-

... More
ii] Ordinary Kilometer Stone (Precast)

9

-

-

... More
Miscellaneous Item Setting out i) 1 km reference benchmark and working benchmark

10

-

-

... More
Construction of reference pillars as per Fig. 1600.1 (b) as per drawing and Technical Specification Clause 1602.1

369

-

-

... More
Construction of back piller as per Fig. 1600.1( c) as per drawing and Technical Specification Clause 1602.3

369

-

-

... More
Construction of Job pillers as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4

46

-

-

... More
Routine Maintenance

-

-

-

... More
First Year

-

-

-

... More
Second Year

-

-

-

... More
Third Year

-

-

-

... More
Fourth Year

-

-

-

... More
Fifth Year

-

-

-

-

-

-

... More
Add GST @ 18%

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.