Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Solid Waste Management
Eprocure
Opening Date3 Oct 2023
Closing Date18 Oct 2023
Tender Amount₹ 4,87,58,327 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 9,88,000Document Cost
₹ 10,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_CEAR_128483_1Bid Award Id
ViewTender No
AR22AR0901043Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
SUB-HEAD:- EARTHEN SHOULDER
Construction of subgrade and earthen shoulders with approved material obtained from way cutting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.
1561.83
-
-
Granular Sub-base with Well Graded Material (Table 400.1)Grade-B :-
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Drawing and Technical Specificateion Clause No 401[Gravel/Soil-Aggregate Base (Table 400.2) Grading B]
2450.01
-
-
WBM 3 FOR BASE COURSE ( 75 mm thick) Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(a)By Manual means.
1421.02
-
-
Prime coat. Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 [Low porosity]
14968.2
-
-
Item : Tack Coat.
Providing and applying Tack Coat with Bitumen Emulsion (RS-1)using emulsion distrubuter @ 0.25 to 0.30 Kg per Sqm. On prepared dry and hungry bituminus surface clean with hydraulic broom as per technical specification 503.
14968.2
-
-
Mix Seal Surfacing
Providing, laying and rolling of close-graded premix surfacing material of 20 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509
Inclusion of 5% waste plastic
18946.93
-
-
R.C.C Slab Culverts [1.50 mtr span - 6 Nos]
FOUNDATION
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material
449.69
-
-
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) (a) Foundation & Plinth
56.21
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
320.79
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
133.73
-
-
Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.[Granular material]
17.96
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
93.6
-
-
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Nominal mix
16.13
-
-
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25) 1:1.5:3
22.96
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ) ( Coping of Return wall)
2.88
-
-
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 a) For nominal mix 1:2:4[hand mixing]
2.3
-
-
Supplying, fitting and placing with HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 a) HYSD Bars Reinforcement
1.17
-
-
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 (DRRM Appron)
34.02
-
-
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 [RRM in CM 1:5] (Toe Wall)
23.09
-
-
Item : Slab Culvert 2.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002) = 3 Nos Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material
259.54
-
-
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) (a) Foundation & Plinth
25.95
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
71.62
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
87.86
-
-
Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.
28.76
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
114
-
-
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Hand mix
8.5
-
-
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25) 1:1.5:3
17.84
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ) ( Coping of Return wall)
2.16
-
-
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 a) For nominal mix 1:2:4[hand mixing]
1.06
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(P.C.C grade M10) (Raft & Cutoff Wall)
84.53
-
-
Supplying, fitting and placing with HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 a) HYSD Bars Reinforcement
1.35
-
-
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 (DRRM Appron)
17.19
-
-
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 [RRM in CM 1:5] (Toe Wall)
40.46
-
-
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 ( Sand filling under Raft and Approns including watering, ramming, consolidating and dressing complete.)
51.45
-
-
Item : Slab Culvert 4.00 mtr. span, 3.64 mtr high (As per IRC SP-20-2002) = 1 Nos Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.
174.1
-
-
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10) (a) Foundation & Plinth
15.76
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
97.2
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
79.18
-
-
BackFilling behind abutment, wing wall and return wall complete as per drawing & techanical specification Clause 1204.3.8(Grannular Meterial)
30.54
-
-
Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7
48
-
-
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 20) 1:2:4 Hand mix
3.01
-
-
Plain/reinforced cement concrete in superstructure complete as per drawings and technical specification Clauses 800, 1205.4 &1205.5(R.C.C grade M 25) 1:1.5:3
13.68
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (P.C.C. grade M 20 ) ( Coping of Return wall)
0.96
-
-
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 a) For nominal mix 1:2:4[hand mixing]
0.38
-
-
Supplying, fitting and placing with HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202 a) HYSD Bars Reinforcement
0.86
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203(P.C.C grade M10) (Raft & Cutoff Wall)
28.18
-
-
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 (DRRM Appron)
16.59
-
-
Item : Hume Pipe Clvt. 1000 mm dia.TYPE-I (As per IRC SP-20-2002 & SP :48-1998) Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.
68
-
-
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109
3.72
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 [P.C.C. grade M 20 Nominal mix (1:2:4)]
1.6
-
-
Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ] Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)
3.32
-
-
Stone Masonry Work in cement mortar in foundation of Head walls complete as per drawing and technical specification Clasue 1109 [In 1:4 cement mortar]
33.36
-
-
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia]
5
-
-
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
1.73
-
-
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]
22.29
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
16
-
-
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
10.25
-
-
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20]
2.85
-
-
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
0.23
-
-
R/Wall & B/Wall
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
161.6
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
181.39
-
-
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
168.22
-
-
Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7
132.3
-
-
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]
148.37
-
-
Sausage wire crated boulder Wall [Gabion Structure] Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
225
-
-
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. ( Based on SDB Rural Road Chapter-14, Item No.14.2)
270
-
-
Road Side Drain [Trapizoidal] Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (i) Upto 3m depth
45
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]
9
-
-
Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]
14.4
-
-
Cement plaster 15 mm thick 1:4 on stone masonry
184
-
-
V-SHAPE SIDE DRAIN
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
129.27
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]
51.15
-
-
Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]
110.67
-
-
Cement plaster 15 mm thick 1:4 on stone masonry
644.8
-
-
Item : Road Furniture
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)
5
-
-
b) 5th Km. Stone (size 107.50x58x25cm)
1
-
-
c) 200m stone (precost)
25
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
9
-
-
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
9
-
-
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
18
-
-
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
20
-
-
Guard Posts
88.96
-
-
Sub-Head : SETTING OUT a] Reference benchmark and working bench mark
5
-
-
b] Reference Pillar
5
-
-
c] Back Pillar.
251
-
-
d] Job Pillar
40
-
-
Routine Maintenance
-
-
-
First Year
-
-
-
Second Year
-
-
-
Third Year
-
-
-
Fourth Year
-
-
-
Fifth Year
-
-
-
GST
-
-
-
Add GST @ 18%
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements