Road From Sarli To Milli Village (full Stage)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SH (B):-SETTING OUT

-

-

-

... More
a] Reference benchmark and working bench mark

26.06

-

-

... More
b] Reference Pillar

26.06

-

-

... More
c] Back Pillar.

1304

-

-

... More
d] Job Pillar

208.48

-

-

... More
SH (C):-EARTHWORK IN ROAD FORMATION

-

-

-

... More
Excavation in ordinary rock using mechanical means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.

316499.38

-

-

... More
Excavation in ordinary rock using mechanical means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.

206834.98

-

-

... More
Excavation in Hard rock in hilly area requiring blasting , by mechanical means, and disposal of excavated rock asper Clause 1603.2. a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.

46302.95

-

-

... More
SH (D):-Hume Pipe Clvt. 1000 mm dia.TYPE-I (As per IRC SP-20-2002 & SP :48-1998)

-

-

-

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

1700.01

-

-

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 802,803,1202&1203

92.97

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 [P.C.C. grade M 20 Nominal mix (1:2:4)]

40

-

-

... More
Bedding for Pipe [ Type A ( Concrete Cradle ) Bedding ]

-

-

-

... More
Laying concrete cradle bedding with M15 Grade Cement Concrete as per Clause 1105 (i)

82.93

-

-

... More
Stone Masonry Work in cement mortar in foundation complete as per drawing and technical specification Clasue 702,704,1202&1203 [In 1:4 cement mortar]

834.03

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia]

125

-

-

... More
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301

43.21

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

557.29

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

400

-

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

256.15

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 [R.C.C grade M 20 For design mix RCC M 20]

71.34

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

5.73

-

-

... More
SH (E):-CD-1.50m Span,CD-2.00m Span,CD-4.00m Span & 6.00m Span (As per IRC SP-20-2002)

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

5188.01

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)

-

-

-

... More
a) Foundation & Plinth

562.08

-

-

... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)

3623.62

-

-

... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)

2173.4

-

-

... More
Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.[Granular material]

566.41

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

2208

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (R.C.C grade M 20)

509.59

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5

-

-

-

... More
a) For nominal mix 1:2:4(Hand mixing)

21.88

-

-

... More
Supplying, fitting and placing with MS bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

-

-

-

... More
a) MS Deformed Bars

17.47

-

-

... More
SH (F):-RCC BRIDGE 10 Mtr. SPAN (MINOR BRIDGE)

-

-

-

... More
Abutment

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

-

-

-

... More
(i)Ordinary soil Upto 3 m depth

706.32

-

-

... More
(ii)Below water level Marshy soil

336.68

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203

-

-

-

... More
P.C.C grade M 10[nominal mix 1:3:6]

70.63

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

-

-

-

... More
P.C.C grade M 15 [Nominal mix 1:2.5:5(Hand mixing)]

768

-

-

... More
Centering and Shuttering including strutting , propping and removal of form work etc.

-

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

-

-

-

... More
R.C.C grade M 20

12.67

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

96

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8

-

-

-

... More
(i) Granular material

230.4

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1005,1010 and 1202

11.16

-

-

... More
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete, including all accessories as per drawings and technical specification Clause 1207.1

168000

-

-

... More
RETURN WALL

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.

-

-

-

... More
(i)Ordinary soil Upto 3 m depth

819.5

-

-

... More
(ii)Below water level Marshy soil

448

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203

-

-

-

... More
P.C.C grade M 10[nominal mix 1:3:6]

81.95

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

-

-

-

... More
P.C.C grade M 15 [Nominal mix 1:2.5:5(Hand mixing)]

738.26

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

288

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8

-

-

-

... More
(i) Granular material

324.48

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

5.27

-

-

... More
DECK SLAB

-

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204

-

-

-

... More
R.C.C. grade M 25 [for height upto 5Mtr]

111.06

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

9.83

-

-

... More
Drainages spouts complete as per drawing and technical specification clause 1209.

32

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

10.26

-

-

... More
Providing and laying a buried expansion joint, covered with 12 mm thick, 200 mm wide galvanised weldable structrual steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8mm dia, 100mm long galvanised nails spaced 300mm c/c along the centre lne of the plate. as per technical specifications Clauses 1207.2.3

24

-

-

... More
Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.

24

-

-

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

91.2

-

-

... More
Construction of RCC guide posts of 250 mm dia M20 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and Technical Specification Clause 1608.2

28

-

-

... More
SH (G):-BUG Bridge over Walu River of 50 Mtr. clear span

-

-

-

... More
Foundation

-

-

-

... More
Earth work in excavation for foundation of structures as per drawings & technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material as per MORTH clause No.304.

-

-

-

... More
i. In Ordinary Soil

-

-

-

... More
A. Mechanical Means

-

-

-

... More
ii. 3.00m to 6.00m depth (without dewatering)

445.67

-

-

... More
ii. with dewatering

-

-

-

... More
Upto 3m depth

493.21

-

-

... More
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203 PCC M15

17.83

-

-

... More
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203 . RCC M25

143.91

-

-

... More
Sub Structure

-

-

-

... More
Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications clause 804,806,807,1202 & 1204 1i.Height 0.0 m to 5.0m

-

-

-

... More
F. . RCC M-25 Grade

-

-

-

... More
i. Height upto 5.0m to 10m

187.97

-

-

... More
Providing concrete for plain cement concrete in open foundation complete as per drawings and technical specifications clause 1500,1700 & 2100 of MORTH Specification E.PCCM15

30.38

-

-

... More
Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specification clause 1000 and 1002

11.27

-

-

... More
Sub Structure

-

-

-

... More
Supplying, fitting and placing un-coated TMT bar reinforcement in Sub Structure complete as per drawing and technical specification clause 1002,1005,1010 & 1200

23.55

-

-

... More
Providings weep holes in brick massonary/stone massonary, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC Pipe extending through the full width of the structures with slopes of 1(V):20(H) towards drawings face complete as per drawing and technical specifications clause 2200 & 2706

120

-

-

... More
Back filling behind Abutment , Wing Wall and return wall complete as per drawing and Technical specification clause 1204.3.8 i) Granular Material

587.5

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be cast steel/fabricated structure steel, metal and elastomer elements to be as per IRC:83 parts I & II respecitvely and other parts conforming to BS 5400 sections 9.1 & 9.2 and clause 2006 of MORT&H specifications complete as per drawing and approved Technical specifications

500

-

-

... More
Super Structure

-

-

-

... More
Supplying , Fabrication, fixing in position, launching in position, painting etc. all complete for Structural Steel Truss ( Fy=250N/mm^2) including splicing,weilding,bolting etc. all complete as per drawing and Technical specification at section 1900 of MORT&H Specification.

93.85

-

-

... More
Providing and laying reinforced cement concrete in supperstructure as per drawing and technical specifications Clauses 800,1205.4 and 1205.5

-

-

-

... More
ii. RCC M-25 Grade Case I. usuing concrete mixture

-

-

-

... More
ii. Height 5.0m to 10.0m

69.84

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in Super Structure complete as per drawing and technical specification clause 1002,1010 and 1202

9.57

-

-

... More
Providing and laying cement concrete wearing coat M 30 grade including reinforcement complete as per drawing and Technical Specifications of clause 800 and 1206.3

20.91

-

-

... More
Providing, fitting and fixing mild steel railing complete as per drawing and technical specificatin clause 1208.2

122

-

-

... More
Providing and laying of elastomeric slab seal expansion joint complete as per approved drawing and specifications to be installed by manufacturer or their authorised representatives ensuring complience to the manufacturer"s instructions for installation and as per technical specifications clause 1207.2.5

11.9

-

-

... More
Drainage spouts complete as per approved drawings and technical specifications clause 1209

18

-

-

... More
PCC M15 ordinary grade (1:2.5:5) in levelling course below approach slab complete as per drawing and technical specifications clause 800 and 1211

4.65

-

-

... More
Reinforced cement concrete M-25 Grade Approach Slab including reinforcement and form work complete as per drawing and technical specification clause 800 and 1211

13.95

-

-

... More
Protection work:

-

-

-

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause1302

-

-

-

... More
I. Stone/Boulder

399.62

-

-

... More
Providing and laying filter material underneath pitching in slopes as per drawing and technical specifications Clause1302

199.81

-

-

... More
Providing and laying of boulder apron laid in wire crates with 4mm dia GI wire conforming to IS 280 and IS 4826 in 100mmX100mm mesh ( woven diagonally ) including 10 percent extra for laps and joints laid with stone boulders weighing not less than 25 KG each as per drawing and technical specifications clause 1301.

283.98

-

-

... More
SUB: SOIL INVESTIGATION

-

-

-

... More
Cost of transportation of plants, equipments and personal effects to the work site and back as per the mobilisation.

2

-

-

... More
Boring/ drilling holes at the abutments, anchor block in river banks through all kind of soil and rock upto depth of 20 m from the ground level ( 50 mm dia ).

12

-

-

... More
1bore in each abutment point @ 8.00 M Deep

-

-

-

... More
Collection of soil sample and conducting on selection, selected soil and rock samples to natural moisture contents particles size, distribution of liquid and plastic limit, bulk and dry density of confined and specific gravity on soil samples, moisture absorption , unit weight, ceriazial compressive strength test etc. complete.

3

-

-

... More
Compilation of laboratory test result including preparation and submission of report

3

-

-

... More
SH (H):-BUG Bridge over Palo River of 50 Mtr. clear span

-

-

-

... More
Foundation

-

-

-

... More
Earth work in excavation for foundation of structures as per drawings & technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material as per MORTH clause No.304.

-

-

-

... More
i. In Ordinary Soil

-

-

-

... More
A. Mechanical Means

-

-

-

... More
ii. 3.00m to 6.00m depth (without dewatering)

445.67

-

-

... More
ii. with dewatering

-

-

-

... More
Upto 3m depth

493.21

-

-

... More
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203 PCC M15

17.83

-

-

... More
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203 . RCC M25

143.91

-

-

... More
Sub Structure

-

-

-

... More
Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications clause 804,806,807,1202 & 1204 1i.Height 0.0 m to 5.0m

-

-

-

... More
F. . RCC M-25 Grade

-

-

-

... More
i. Height upto 5.0m to 10m

187.97

-

-

... More
Providing concrete for plain cement concrete in open foundation complete as per drawings and technical specifications clause 1500,1700 & 2100 of MORTH Specification E.PCCM15

30.38

-

-

... More
Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specification clause 1000 and 1002

11.27

-

-

... More
Sub Structure

-

-

-

... More
Supplying, fitting and placing un-coated TMT bar reinforcement in Sub Structure complete as per drawing and technical specification clause 1002,1005,1010 & 1200

23.55

-

-

... More
Providings weep holes in brick massonary/stone massonary, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC Pipe extending through the full width of the structures with slopes of 1(V):20(H) towards drawings face complete as per drawing and technical specifications clause 2200 & 2706

120

-

-

... More
Back filling behind Abutment , Wing Wall and return wall complete as per drawing and Technical specification clause 1204.3.8 i) Granular Material

587.5

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be cast steel/fabricated structure steel, metal and elastomer elements to be as per IRC:83 parts I & II respecitvely and other parts conforming to BS 5400 sections 9.1 & 9.2 and clause 2006 of MORT&H specifications complete as per drawing and approved Technical specifications

500

-

-

... More
Super Structure

-

-

-

... More
Supplying , Fabrication, fixing in position, launching in position, painting etc. all complete for Structural Steel Truss ( Fy=250N/mm^2) including splicing,weilding,bolting etc. all complete as per drawing and Technical specification at section 1900 of MORT&H Specification.

93.85

-

-

... More
Providing and laying reinforced cement concrete in supperstructure as per drawing and technical specifications Clauses 800,1205.4 and 1205.5

-

-

-

... More
ii. RCC M-25 Grade Case I. usuing concrete mixture

-

-

-

... More
ii. Height 5.0m to 10.0m

69.84

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in Super Structure complete as per drawing and technical specification clause 1002,1010 and 1202

9.57

-

-

... More
Providing and laying cement concrete wearing coat M 30 grade including reinforcement complete as per drawing and Technical Specifications of clause 800 and 1206.3

20.91

-

-

... More
Providing, fitting and fixing mild steel railing complete as per drawing and technical specificatin clause 1208.2

122

-

-

... More
Providing and laying of elastomeric slab seal expansion joint complete as per approved drawing and specifications to be installed by manufacturer or their authorised representatives ensuring complience to the manufacturer"s instructions for installation and as per technical specifications clause 1207.2.5

11.9

-

-

... More
Drainage spouts complete as per approved drawings and technical specifications clause 1209

18

-

-

... More
PCC M15 ordinary grade (1:2.5:5) in levelling course below approach slab complete as per drawing and technical specifications clause 800 and 1211

4.65

-

-

... More
Reinforced cement concrete M-25 Grade Approach Slab including reinforcement and form work complete as per drawing and technical specification clause 800 and 1211

13.95

-

-

... More
Protection work:

-

-

-

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause1302

-

-

-

... More
I. Stone/Boulder

399.62

-

-

... More
Providing and laying filter material underneath pitching in slopes as per drawing and technical specifications Clause1302

199.81

-

-

... More
Providing and laying of boulder apron laid in wire crates with 4mm dia GI wire conforming to IS 280 and IS 4826 in 100mmX100mm mesh ( woven diagonally ) including 10 percent extra for laps and joints laid with stone boulders weighing not less than 25 KG each as per drawing and technical specifications clause 1301.

283.98

-

-

... More
SUB: SOIL INVESTIGATION

-

-

-

... More
Cost of transportation of plants, equipments and personal effects to the work site and back as per the mobilisation.

2

-

-

... More
Boring/ drilling holes at the abutments, anchor block in river banks through all kind of soil and rock upto depth of 20 m from the ground level ( 50 mm dia ).

12

-

-

... More
1bore in each abutment point @ 8.00 M Deep

-

-

-

... More
Collection of soil sample and conducting on selection, selected soil and rock samples to natural moisture contents particles size, distribution of liquid and plastic limit, bulk and dry density of confined and specific gravity on soil samples, moisture absorption , unit weight, ceriazial compressive strength test etc. complete.

3

-

-

... More
Compilation of laboratory test result including preparation and submission of report

3

-

-

... More
SH (I):-BUG BRIDGE 60 Mtr. Span over Kurung River

-

-

-

... More
Foundation

-

-

-

... More
Earth work in excavation for foundation of structures as per drawings & technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material as per MORTH clause No.304.

-

-

-

... More
i. In Ordinary Soil

-

-

-

... More
A. Mechanical Means

-

-

-

... More
i. 3.00m to 6.00m depth (without dewatering)

535.12

-

-

... More
ii. with dewateringUpto 3m depth

510.51

-

-

... More
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203 PCC M15

18.45

-

-

... More
Providing concrete for plain/Reinforced concrete in open foundation complete as per drawings and technical specifications clause 802,803,1202 & 1203 . RCC M25

148.77

-

-

... More
Sub Structure

-

-

-

... More
Plain/Reinforced Cement concrete, in Substructure complete as per Drawing and Technical Specifications clause 804,806,807,1202 & 1204 1i.Height 0.0 m to 5.0m

-

-

-

... More
F. . RCC M-25 Grade

-

-

-

... More
i. Height upto 5.0m to 10m

30.3

-

-

... More
Providing concrete for plain cement concrete in open foundation complete as per drawings and technical specifications clause 1500,1700 & 2100 of MORTH Specification E.PCCM15

30.38

-

-

... More
Supplying, fitting and placing un-coated TMT bar reinforcement in foundation complete as per drawing and technical specification clause 1000 and 1002

11.65

-

-

... More
Supplying, fitting and placing un-coated TMT bar reinforcement in Sub Structure complete as per drawing and technical specification clause 1002,1005,1010 & 1200

26.52

-

-

... More
Providings weep holes in brick massonary/stone massonary, plain/reinforced concrete abutment, wing wall, return wall with 100mm dia AC Pipe extending through the full width of the structures with slopes of 1(V):20(H) towards drawings face complete as per drawing and technical specifications clause 2200 & 2706

120

-

-

... More
Back filling behind Abutment , Wing Wall and return wall complete as per drawing and Technical specification clause 1204.3.8 i) Granular Material

847.44

-

-

... More
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, complete assembly to be cast steel/fabricated structure steel, metal and elastomer elements to be as per IRC:83 parts I & II respecitvely and other parts conforming to BS 5400 sections 9.1 & 9.2 and clause 2006 of MORT&H specifications complete as per drawing and approved Technical specifications

640

-

-

... More
Super Structure

-

-

-

... More
Supplying , Fabrication, fixing in position, launching in position, painting etc. all complete for Structural Steel Truss ( Fy=250N/mm^2) including splicing,weilding,bolting etc. all complete as per drawing and Technical specification at section 1900 of MORT&H Specification.

138.34

-

-

... More
Providing and laying reinforced cement concrete in supperstructure as per drawing and technical specifications Clauses 800,1205.4 and 1205.5

-

-

-

... More
ii. RCC M-25 Grade Case I. usuing concrete mixture

-

-

-

... More
ii. Height 5.0m to 10.0m

83.61

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in Super Structure complete as per drawing and technical specification clause 1002,1010 and 1202

11.46

-

-

... More
Providing and laying cement concrete wearing coat M 30 grade including reinforcement complete as per drawing and Technical Specifications of clause 800 and 1206.3

25.04

-

-

... More
Providing, fitting and fixing mild steel railing complete as per drawing and technical specificatin clause 1208.2

142

-

-

... More
Providing and laying of elastomeric slab seal expansion joint complete as per approved drawing and specifications to be installed by manufacturer or their authorised representatives ensuring complience to the manufacturer"s instructions for installation and as per technical specifications clause 1207.2.5

11.9

-

-

... More
Drainage spouts complete as per approved drawings and technical specifications clause 1209

22

-

-

... More
PCC M15 ordinary grade (1:2.5:5) in levelling course below approach slab complete as per drawing and technical specifications clause 800 and 1211

4.65

-

-

... More
Reinforced cement concrete M-25 Grade Approach Slab including reinforcement and form work complete as per drawing and technical specification clause 800 and 1211

13.95

-

-

... More
Protection work:

-

-

-

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause1302

-

-

-

... More
I. Stone/Boulder

299.72

-

-

... More
Providing and laying filter material underneath pitching in slopes as per drawing and technical specifications Clause1302

149.86

-

-

... More
Providing and laying of boulder apron laid in wire crates with 4mm dia GI wire conforming to IS 280 and IS 4826 in 100mmX100mm mesh ( woven diagonally ) including 10 percent extra for laps and joints laid with stone boulders weighing not less than 25 KG each as per drawing and technical specifications clause 1301.

303.71

-

-

... More
SUB: SOIL INVESTIGATION

-

-

-

... More
Cost of transportation of plants, equipments and personal effects to the work site and back as per the mobilisation.

2

-

-

... More
Boring/ drilling holes at the abutments, anchor block in river banks through all kind of soil and rock upto depth of 20 m from the ground level ( 50 mm dia ).

-

-

-

... More
1bore in each abutment point @ 8.00 M Deep

12

-

-

... More
Collection of soil sample and conducting on selection, selected soil and rock samples to natural moisture contents particles size, distribution of liquid and plastic limit, bulk and dry density of confined and specific gravity on soil samples, moisture absorption , unit weight, ceriazial compressive strength test etc. complete.

3

-

-

... More
Compilation of laboratory test result including preparation and submission of report

3

-

-

... More
SH (J):- Sausage wire crated boulder Protection Structure(Retaining Wall-3.00 mtr height) & Breast wall - 2.00 mtr high ( As per IRC SP-20-1979) .

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.

564.74

-

-

... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)

704.12

-

-

... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)

440.75

-

-

... More
Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7

396

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

598.2

-

-

... More
SH(K):- PAVEMENT

-

-

-

... More
SHOULDER

-

-

-

... More
Construction of subgrade and earthen shoulders with approved material obtained from way cutting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1.

8065.73

-

-

... More
Granular Sub-base with Well Graded Material ( Clause Table 400.2) Grade-B :-

-

-

-

... More
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Drawing and Technical Specificateion Clause No 401[Gravel/Soil-Aggregate Base (Table 400.2) Grading B]

20243.18

-

-

... More
WBM 3 for Base Course ( 75 mm thick)

-

-

-

... More
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(a)By Manual means.

6054.86

-

-

... More
PRIME COAT

-

-

-

... More
Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 [Low porosity]

80731.5

-

-

... More
Tack coat:-

-

-

-

... More
Providing and applying Tack Coat with Bitumen Emulsion (RS-1)using emulsion distrubuter @ 0.25 to 0.30 Kg per Sqm. On prepared dry and hungry bituminus surface clean with hydraulic broom as per technical specification 503.

80731.5

-

-

... More
20 mm thick Open Graded Premix Carpet using Bitumen Emulsion as per Technical Specification Clause 508.2

-

-

-

... More
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates(0.27Cum/10Sqm) either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100kN static roller capacity ,finished to required level and grades to be folloed by seal coat of either Type - A orType - B or Type - C as per Technical Specification . By Manual Means[Bitumen Emulsion]

80731.5

-

-

... More
Seal Coat :-

-

-

-

... More
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 By Manual Means. Type- A [Bitumen Emulsion(S-S)]

80731.5

-

-

... More
SH (L):-C.C Side Drain [Trapizoidal Shape & V Shape] ( Cross section as per IRC SP-20-2002 -RRM , Page 113 , Fig. 6.2.c )

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (i) Upto 3m depth

699.12

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]

200.02

-

-

... More
Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]

379.79

-

-

... More
Cement plaster 15 mm thick 1:4 on stone masonry

-

-

-

... More
SH(M) :-ROAD FURNITURE:-

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703

-

-

-

... More
a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)

26.06

-

-

... More
b) 5th Km. Stone (size 107.50x58x25cm)

5.21

-

-

... More
c) 200m stone (precost)

130.3

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

46.91

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

46.91

-

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2

52.12

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

156.36

-

-

... More
Providing and Fixing PMGSY Logo Board at starting point

-

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and Fixing Title information Board of PMGSY Project(RCC)

-

-

-

... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

2

-

-

... More
Providing and Fixing Citizen information Board of PMGSY Project(RCC)"A"

-

-

-

... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

3

-

-

... More
Safety Devices and Signs in Construction Zones

-

-

-

... More
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001.

-

-

-

... More
i) Men at work

4

-

-

... More
ii) Diversion

4

-

-

... More
iii) Road closed

4

-

-

... More
iv) Stop

4

-

-

... More
v) Slow

4

-

-

... More
vi) Speed limit

4

-

-

... More
SH(N):-GUARD POST

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil

22.4

-

-

... More
RCC M 20 grade Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807. 1202 and 1204

85.4

-

-

... More
HYSD steel bars Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807. 1202 and 1204

6.83

-

-

... More
Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701

558.25

-

-

... More
SH(O):- LSB Maintenance

-

-

-

... More
SH(P):- 5 - Years Maintenance

-

-

-

... More
First Year Maintenance

-

-

-

... More
Second Year Maintenance

-

-

-

... More
Third Year Maintenance

-

-

-

... More
Fourth Year Maintenance

-

-

-

... More
Fifth Year Maintenance

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.