Pradhan Mantri Gram Sadak Yojana Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Pradhan Mantri Gram Sadak Yojana - PMGSY Tender
Manpower Supply
Eprocure
Opening Date16 Jul 2018
Closing Date1 Aug 2018
Tender Amount₹ 38,13,00,360 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 77,82,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_CEAR_65981_1Bid Award Id
ViewTender No
RWD/DPIU-II/PMGSY/CT-NIT/2Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Construction of reference pillars as per Fig 1600.1 (b) as per drawing and techinical specification Clause1602.1
75
-
-
Construction of job pillars as per Fig 1600.1 (d) as per drawing and techinical specification Clause1602.4
40
-
-
SH: EARTHWORK IN ROAD FORMATION { Formation cutting }
-
-
-
EARTHWORK IN HILLY ROAD-FC Excavation in all kinds of soil,ordinary rock and hard rock ( requiring blasting including cutting and trimming of slopes as per specification and deposal cut materilas with a lift upto 1.5 mtr and lead upto 20mt
697121.25
-
-
SH : EARTHEN DRAIN
-
-
-
Construction of unlined surface drain of avareage cross-sectional area 0.40sqm in all kinds soil to specified line,grade,levels and dimensions excavated materials to be used in embankment with a lift of 3m and lead of 50m(Avarage lead 25m) as per technica
18820
-
-
SH: CD,Protection and Minor Bridges
-
-
-
CD and Protection Work. Earth work in excavation for structure as per drawing and technical specification clause 305.1 in all kinds of soil, ordinary rock,hard rock ( requiring blasting)-( blasting prohibited) and marshy soil including setting out,constr
35696.73
-
-
Providing concrete for plain/reinforced concrete in open foundations as drawing and technical specifications clause 802,803,1202 and 1203. PCC grade M15 1:2.5:5 ( Hand mixing).
2673.22
-
-
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed Rubble masonry ( 1st sort ) In 1:4 cement mortar
5862.44
-
-
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed Rubble masonry ( 2nd sort ) In 1:5 cement mortar
11270.12
-
-
Providing and laying reinforced cement concrete in super structure as per drawing and specification clause -800 , 1205.4 & 1205.5 ( RCC M25).
753
-
-
Providing and laying reinforced cement concrete in superstructure as per Drg. and technical specification clauses 800,1205.4,1205.5 For nominal mix 1:2:4(Hand mixing)
494.56
-
-
Supplying fitting and placing HYSD bar reinforcement(Fe415) in superstructure complete as per drawing and technical specification.Clause -1002,1010 &1202 (as per RRM plate No. 7.08)
91.56
-
-
Back filing behind the Abutment, wing wall and return wall complete as per drawing and technical specifications ,clause 1204.3.8 Granular materials
4720.84
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
4504
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
I). P.C.C grade M 10
-
-
-
(I) Nominal mix 1:3:6
189.3
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
For height upto 5 m.
-
-
-
III) R.C.C. grade M 20
1979.04
-
-
Drainage spouts complete as per drawing and technical specification clause 1209.
42
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
For height upto 5 m.
-
-
-
III) R.C.C. grade M 20
28.17
-
-
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
113.88
-
-
Providing and laying of an elastometri slab expansion joint complete as per approved drawing and approved specification to be installed by manufacture/supplier or their authorised representative ensuring compliance to the manufacture's.
36
-
-
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping /laying in SWG wire mesh of 10 cm x 10 cm (woven diagonally) 4 mm dia i/c lying properly the mesh by cutting the mouth and
510.3
-
-
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing .Three MS plates of 1.6mm thk.top and middle plate duly welded with MS flat iron 25mmx5mm size on back on edges. The lower plate will be welded with MS angle iron frame of 25mmx25mmx5mm.The angle iron frame of the lower most plate and flate iron frame of middle plate will be welded to 2nos.75mmx75mmof 12 swg sheet tubes posts duly embedded in c.c M-15 grade blocks of 450mmx450mmx600mm,600mmbelow ground level.The top most diamond plate will be welded to middle plate by 47mmx47mm of 12 swg steel plate tube . All M.S will be stove enameled on both sides.Lettering and printing arrows,borders etc will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour.All section of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per Drg.clause 1701 and 1700.1
2
-
-
Kilometre stone : Reinforcement cement concrete M15 grade kilometre stone/local stone of standard design as per IRC -8 fixing in position including painting etc as per drawing and technical specification Clause 1703
-
-
-
5th Kilometere stone precast
6
-
-
Ordinary Kilometre stone (precast)
35
-
-
Providing and fixing traffic signs for limited period at suitable location in construction zone comprising of warning zone approved transition zone….
-
-
-
Men at work
2
-
-
Diversion
2
-
-
Road closed
2
-
-
Stop
2
-
-
Slow
2
-
-
SH : MAJOR BRIDGE SPAN 50.00 METRE(BUG)
-
-
-
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side
437.48
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
PCC M10 ( Nominal Mix 1:3:6)
7.81
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
PCC Grade M20
78.24
-
-
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204
-
-
-
R.C.C. grade M 25
113.1
-
-
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203
-
-
-
PCC M15 (Nominal Mix 1:2.5:5)
16.5
-
-
Providing steel R.S.Js/built-up steel sections including cutting, welding/rivetting, hoisting, fixing in position for composite girders with shear connectors complete with painting as per drawing and technical specifications Clause 1205.6
101.36
-
-
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5
-
-
-
R.C.C M 25
62.05
-
-
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
6.84
-
-
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
12.5
-
-
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
6.04
-
-
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
10.75
-
-
Providing fitting and fixing mild steel railing complete as per drawing and technical specifications Clause 1208.2
116.6
-
-
Providing and laying of an elastomeric slab seal expansion joint complete as per approved drawing and approved specifications to be installed by manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer’s instruction
9.4
-
-
Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
340
-
-
Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
340
-
-
Drainage spouts complete as per drawing and technical specifications Clause 1209
12
-
-
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing
80
-
-
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8
390.85
-
-
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211
8.28
-
-
Providing and inserting dowels bars of 25 mm dia (TMT) to a depth of 400 mm anchored in the hard rock by grouting with cement slurry, as per specification and making good all complete as directed.
84
-
-
Providing & laying of boulder apron laid in wire crates with 14mm dia GI wire conforming to IS : 280 in 100 mm x 100mm mesh (woven diagonally) including 10% extra for laps 7 joints laid with stone boulder weighing not less than 25 Kg each as per drawing
250
-
-
Providing and laying Pitching on slopes laid over prepared Filter media asper drawing and technical specifications clause 1302 I. Stone Boulder
230.51
-
-
Providing and laying Filter material underneath Pitching in slopes complete asper drawing and technical specifications clause 1302
115.25
-
-