L024-road From Tali-pija Pmgsy Road To Richik.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CEAR_132399_1Bid Award Id
ViewTender No
AR1908130Tender Authority
Pradhan Mantri Gram Sadak Yojana ViewPurchaser Address
-Website
http://http://omms.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
c] Back Pillar.
601
-
-
... More
d] Job Pillar
96
-
-
... More
SH: SITE CLEARANCE
-
-
-
... More
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material. i)By Manual means:- (a) In area of thorny jungle.
10.8
-
-
... More
SH: EARTHWORK IN ROAD FORMATION
-
-
-
... More
Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site with a lift upto 1.5 m and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and crosssections as per Technical Specification Clause 302.3.5
352488.17
-
-
... More
SH: SUBGRADE PREPARATION
-
-
-
... More
Loosening of the ground upto a level of 300mm below the sub grade level watering graded and compacted in layers to meet requirement of Tables 300.1 and 300.2 for subgrade construction as per technical specification Clause 303.5.2
18981.04
-
-
... More
SH: EARTHEN SHOULDER
-
-
-
... More
Construction of sub-grade and earthen shoulders with approved material obtained from borrow pith with all lifts and leads, transportating to site, spreading , grading to required slope compacted to meet requirement of Table 300.2 with lead upto 1000 m as per technical specification clouse 303.1.
3734.33
-
-
... More
SH: Non Frost Susceptible Sub-Base (NFSSB)
-
-
-
... More
Non Frost Susceptible Sub-Base (NFSSB) : Construction of Non Frost Susceptible Sub-Base (NFSSB) by Non Frost Susceptible Sub-Base (NFSSB) : Construction of Non Frost Susceptible Sub-Base (NFSSB) by providing granular material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete in all aspects as per Morth specification clause 401. Using naturally occuring gravel
14179.77
-
-
... More
SH: Crushed Stone Base (CSB) :
-
-
-
... More
Providing Crushed Stone Base (CSB) by Providing crushed stone aggregate & stone dust, depositing on a prepared surface by hauling vehicles, spreading, and mixing with a motor grader, watering and compacting with a vibratory roller to achieve the desired compaction as per Morth specification clause complete in all aspects. By Mix in Place Method
7089.88
-
-
... More
SH: Prime Coat
-
-
-
... More
Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.
47265.87
-
-
... More
SH: Tack coat
-
-
-
... More
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.
47265.87
-
-
... More
SH: Bituminous Concrete (40 mm thick)
-
-
-
... More
Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects. (i) For Grading II (13 mm nominal size)
1890.63
-
-
... More
SH: EARTHEN SIDE DRAIN
-
-
-
... More
Construction of Unlined surface drains of average cross-sectional area 0.40 sqm by manual or by mechanical means or both, in all kinds of soil, earth mixed with boulders, ordinary rock, soft rock and hard rock without blasting or with controlled blasting or any alternative methods including cutting and trimming of sides & bottom in accordance with the cross section and loading in tippers and disposal of cut materials & debris with all lead and lifts complete as per specification and as directed by the Engineer-in-Charge
9455
-
-
... More
SH: PUCCA SIDE DRAIN (TRAPEZOIDAL SHAPED)
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of side I. Ordinary soil (i) Upto 3 m depth
1080
-
-
... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 a) Nominal mix 1:2.5:5 PCC grade M15
216
-
-
... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 (i) In 1:4 cement mortar
339.84
-
-
... More
Cement Plaster 15 mm thick 1:4 on stone masonry
370.56
-
-
... More
Neat cement punning
3705.6
-
-
... More
SH: R.C.C Slab Culvert (1.50 mtr-26 Nos, 2.00 mtr-5 Nos, 4.00 mtr-6 Nos. & 6.00 mtr-2 Nos. )
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
4186.28
-
-
... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)
458.82
-
-
... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
2863.01
-
-
... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
1621.97
-
-
... More
Back filling behind the abutment, wing wall and retain wall completeas per the drawing & technical specification.[Granular material]
687.48
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
1586
-
-
... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 (R.C.C grade M 20)
108.97
-
-
... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 I. (R.C.C grade M 20) (ii) For nominal mix 1:2:4 (Hand mixed)
301.76
-
-
... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11
444.08
-
-
... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
24.31
-
-
... More
SH : PROTECTIVE WORKS (R/B Wall: 2 m ht.- 300 mtr., R/B Wall: 3 m ht.- 500 mtr.)
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.
2602
-
-
... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)
1862.1
-
-
... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 4 (1 cement : 4 fine sand).(CRM)
1183.2
-
-
... More
Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7
1470
-
-
... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]
1032.5
-
-
... More
SH : GUARD POSTS (820 Nos.)
-
-
-
... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
2.62
-
-
... More
RCC M 20 grade: Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 804, 805, 806, 807. 1202 and 1204
10
-
-
... More
HYSD steel bars: Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
0.82
-
-
... More
Painting two coats including prime coat on new concrete surface: Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
80.52
-
-
... More
SH: ROAD FURNITURE
-
-
-
... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
-
-
-
... More
a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)
12
-
-
... More
b) 5th Km. Stone (size 107.50x58x25cm)
2
-
-
... More
c) 200m stone (precost)
60
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
21.6
-
-
... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
21.6
-
-
... More
Providing and fixing of typical VVP informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
2
-
-
... More
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2
24
-
-
... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704
72
-
-
... More
Providing and Fixing VVP Logo Board at starting point: Providing and fixing of typical VVP Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint.
1
-
-
... More
Providing and Fixing Title information Board of VVP Project(RCC): Providing and fixing of typical VVP Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
2
-
-
... More
Providing and Fixing Citizen information Board of VVP Project(RCC)"A": Providing and fixing of typical VVP Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint.
3
-
-
... More
Safety Devices and Signs in Construction Zones: Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001.
-
-
-
... More
a. Men at work
4
-
-
... More
b. Diversion
4
-
-
... More
c. Road closed
4
-
-
... More
d. Stop
4
-
-
... More
e. Slow
4
-
-
... More
f. Speed limit
4
-
-
... More
SH: Routine Maintenance
-
-
-
... More
First Year
-
-
-
... More
Second Year
-
-
-
... More
Third Year
-
-
-
... More
Fouth Year
-
-
-
... More
Fifth Year
-
-
-