Pradhan Mantri Gram Sadak Yojana Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Consultancy Services
Civil And Architectural Services
Eprocure
Opening Date23 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 4,61,63,000 
Notes
Download

Costs

Summary

Construction Of Rcc Bridge With Bug Girder Span 1 X 50.00m Over Aba Nallah

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
II) Ordinary rock (not requiring blasting) (i) Upto 3 m depth

254.4

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203

-

-

-

... More
i) P.C.C grade M 10 , Nominal mix 1:3:6

9.88

-

-

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications H) RCC Grade M35 Case-I) Using Concrete Mixer

111.4

-

-

... More
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

11.14

-

-

... More
Providing and inserting dowels bars of 25 mm dia (TMT) to a depth of 500 mm anchored in the hard rock by grouting with cement slurry, as per specification and making good all complete as directed.

96

-

-

... More
Sub - Structure

-

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications

-

-

-

... More
H) RCC Grade M35, Height upto 5m , Case I) Using concrete Mixer

199.99

-

-

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/JINDAL/SHYAM STEEL)

15.7

-

-

... More
Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.

360

-

-

... More
Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications

360

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

100

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Granular material

247.66

-

-

... More
Super structure

-

-

-

... More
Providing steel R.S.Js/built-up steel sections including cutting, welding/rivetting, hoisting, fixing in position for composite girders with shear connectors complete with painting as per drawing and technical specifications Clause 1205.6 Steel section

107.55

-

-

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification C) RCC Grade M 30 Case I) Using Concrete Mixer (i) For solid slab super-structure (q) Height 5m to 10m

90.7

-

-

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202. (The steel to be used should be from primary producer like TATA/SAIL/ESSER STEEL/ JINDAL/SHYAM STEEL)

8.55

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

20.96

-

-

... More
Providing fitting and fixing mild steel railing complete as per drawing and technical specifications Clause 1208.2

117

-

-

... More
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70mm, complete as per approved drawing and standerd specifications to be installed by the manufacturer,s instructions for installation.

12.1

-

-

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

22

-

-

... More
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211 (i) Nominal mix (1:2.5:5)

5.62

-

-

... More
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211

11.26

-

-

... More
Protection Work

-

-

-

... More
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301

117.88

-

-

... More
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I) Stone/Boulder

114.18

-

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

57.1

-

-

... More
Approach Road and informatory signs

-

-

-

... More
Constrction of embankment with approved materials obtained from borrows pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slop and compacting to meet requirement of table 300.1 and 300.2 with lead upto 1000m as per Technic

1850.77

-

-

... More
Construction of subgrade and earthen shoulders with approved materials obtained from borrow pits with lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table 300.1 & 300.2 with lead upto 1000

78.74

-

-

... More
Granular Sub-base with Well Graded Material (Table 400.1) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material

92.39

-

-

... More
Gravel/Soil-Aggregate Base (Table 400.2) Grading A Construction of gravel/soil-aggregate base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller to achieve the desired density, complete as per Technical Specifications Clause 402

184.78

-

-

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (B) By Mechanical Means

138.59

-

-

... More
Primte Coat : Low porosity (i) Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

1847.81

-

-

... More
Tack Coat (i) Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

1847.81

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - II By Mechanical Means (I) Bitumen (S-90)

1847.81

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 B. By Mechanical Means Case - I : Type A (I) Bitumen (S-90)

1847.81

-

-

... More
Providing and Fixing PMGSY Logo Board at starting point Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC, (Size of RCC post 25cmx25cmx90cm below G.L. & 15cm x 15cm x 260cm above G.L.), (Size of board 1x 85cm x 85cm x 7.5cm) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and Fixing Title information Board of PMGSY Project (RCC) Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC, (Size of RCC post 25cm x 25cm x 90cm below G.L. & 15cm x 15cm x 245cm above G.L.), (Size of board 2 x 90cm x 80cm x 7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

2

-

-

... More
Retaining Wall

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material Ordinary soil Upto 3 m depth

413

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6

105

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Random rubble masonry In cement mortar (1:5)

728

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 Granular material

365.6

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

169

-

-

... More
Conformatory Test

-

-

-

... More
Conduct of Bore Hole testing, as per IRC54:2000, sinking of 150mm dia bore hole into sub-surface and conduct of all necessary tests and submission of report with recommendation in three copies

1

-

-

... More
Conduct of Acceptance load testing of completed bridge before opening to the traffic.

1

-

-

... More
Routine Maintenance

-

-

-

... More
First Year

-

-

-

... More
Second Year

-

-

-

... More
Third Year

-

-

-

... More
Fourth Year

-

-

-

... More
Fifth Year

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.