Pradhan Mantri Gram Sadak Yojana Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil Works Others
Construction Material
Eprocure
Opening Date2 Feb 2019
Closing Date14 Feb 2019
Tender Amount₹ 91,18,71,178 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SH: Formation cutting

-

-

-

... More
Excavation in soil in Hilly Area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1

278182.48

-

-

... More
Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting Excavation in hilly area in ordinary rock not requiring blasting by mechanical means including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.

9370.67

-

-

... More
Excavation in Hilly Areas in Hard Rock requiring blasting Excavation in hilly areas in hard rock requiring blasting, by mechanical means, lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2.

279896.74

-

-

... More
Deduction for Salvage materials from roadway hard rock cutting (40% volume of item no 3)

111958.7

-

-

... More
Collecting, sorting and stacking blasted or hand broken hard rock and Granular materials from Hill cutting in measurable stack at site of work as directed the Engineer-in-Charge within a lead of 50 m and lift upto 1.50 m including hand breaking in required sizes.

111958.7

-

-

... More
SH: Road Formation in Embankment/Filling

-

-

-

... More
Construction of Embankment with Material Obtained from Roadway Cutting Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5

24635.99

-

-

... More
SH: Shoulder

-

-

-

... More
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

19470.09

-

-

... More
SH: Bituminouse Pavement

-

-

-

... More
Granular Sub-base with Well Graded Material By Mix in Place Method(Table 400.1)Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.

25282.16

-

-

... More
(i) For Grading I Materia

-

-

-

... More
WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(B) By Manual Means

8886.3

-

-

... More
Prime Coat :Medium porosity Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base/WBM/WMM including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502

114233.15

-

-

... More
Tack Coat Providing and applying tack coat with Bitumen emulsion (CRS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.

114233.15

-

-

... More
20mm thick Open-Graded Premix Carpet using Bituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. Case - I By Manual Means (iv) Polymer Modified Bitumen

114233.15

-

-

... More
Seal Coat Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 By Manual Means Case - I : Type A (iv) Crumb Rubber Modified Bitumen

114233.15

-

-

... More
Sub-Head: Cross Drainage Works (CD)

-

-

-

... More
Excavation for Structures Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Ordinary soil upto 3 metre depth.

7517.54

-

-

... More
Plain cement Concrete M10 (1:3:6 Nominal mix) in leveling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109 (I)

283.2

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6

448.29

-

-

... More
Type B (First Class) Bedding Laying (First Class) bedding on well compacted sand, moorum or approved granular material as per Clause 1105

211.81

-

-

... More
Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design in Single Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding (B) 1000 mm dia

442.5

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 PCC Grade M20 (a) Nominal Mix (1:2:4)

2612.24

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawing and technical specification Clause 802, 803, & 1203 IV) R.C.C.grade M 20

820.66

-

-

... More
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202

15.665

-

-

... More
Substructure (CD)

-

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 RCC Grade M20

738.68

-

-

... More
Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3 (I)

288.94

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Random rubble masonry In cement mortar (1:3)

29.5

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed rubble masonry (1st sort), :3 CM

29.5

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed rubble masonry (1st sort), :3 CM

89.68

-

-

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling

808.75

-

-

... More
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & PCC Grade M 20 Nominial mix (1:2:4)

1280.349

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

330

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. RCC Grade M 20 Nominal Mix 1 : 2 : 4

429.34

-

-

... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11

264.44

-

-

... More
Supplying, fitting and placing TMT bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202

57.661

-

-

... More
Superstructure (CD)

-

-

-

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

9.062

-

-

... More
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8

297.19

-

-

... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304 Cement concrete grade M 10

17.27

-

-

... More
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans, covered with sealant complete as per drawing and technical specifications

408

-

-

... More
Construction of toe walls for protection of slopes as per drawing and technical specifications Clause 1302.5 Random rubble masonry in case of stone pitching laid with cement mortar (1:5)

122.04

-

-

... More
Providing bituminous wearing coat comprising of 20 mm thick premix carpet with 5 mm thick seal coat Type B for culverts as per drawing and technical specifications Clauses 1206.2 and 500

496.74

-

-

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

134

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed rubble masonry (1st sort), :3 CM

89.68

-

-

... More
Filling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling

1

-

-

... More
SH: Gabion wall

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth

1247.4

-

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

138.6

-

-

... More
Providing and laying wire created boulder structures boulder size 22.5 cm to 45 cm having 25 kg average weight for each i/c dumping/laying in S.W.G. Wire mesh of 10 cm x 10 cm (woven diagonally) 4mm dia i/c packing with small size stone spalls and carrying of boulders from a lead of 50 mtr and lift up to 1.5 mtr i/c lying properly the mesh by cutting the mouth and hoisting of wire where felt necessary as per direction of Engineer-in-Charge technical specifications Clause 1301. ( Based on SDB Rural Road Chapter-14, Item No.14.2)

1722.6

-

-

... More
SH: Retataing wall

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Upto 3 m depth Ordinary soil

831.06

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6 Wall Base

218.7

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 In cement mortar (1:3) Random rubble masonry

1003.752

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8(I) Granular material Measurement as per Backfill sheet

174.312

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

540

-

-

... More
SH: Unlined channel

-

-

-

... More
Surface Drains in Soil Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions. Excavated material to be used in embankment with a lift upto 3m and lead of 50 m (average lead 25 m) as per Technical Specification Clause 307. Manual Means

6660

-

-

... More
Surface Drains in Hard Rock (blasting prohibited)

4579.74

-

-

... More
SH: Line channnel

-

-

-

... More
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil upto 3 m depth

8032.5

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6. Base Conc

481.95

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Random rubble masonry In 1:4 cement mortar

3396.6

-

-

... More
SH: Road Furniture

-

-

-

... More
Providing and fixing 'Logo' of PMGSY Project Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

1

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and Fixing Maintenance information Board of PMGSY Project (RCC) Providing and fixing of typical PMGSY Maintenance information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc. as per drawing and Technical Specification Clause 1703 (i) 5th Kilometre Stone (precast)

6

-

-

... More
(ii) Ordinary Kilometer stone (precast)

29

-

-

... More
(iii) 200m Stone (precast)

140

-

-

... More
Traffic Signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801

4

-

-

... More
Construction of Job pillars as per Fig. 1600.1 (d) and Technical Specification Clause 1602.4

123

-

-

... More
Rumble Strips Provision of 15 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking paint

2.1

-

-

... More
Trace Cutting

34.951

-

-

... More
SH: Foundation (LSB)

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom backfilling in trenches with excavated suitable material. Ordinary soil i) Upto 3m depth

1535.488

-

-

... More
ii) 3m to 6m depth

3024.256

-

-

... More
iii) Hardrock (requiring blasting)

193.16

-

-

... More
Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well. (A) Assuming depth of water 1.0 m and height of island to be 1.25m.

6

-

-

... More
Providing and constructing one span service road to reach island location from one pier location to another pier location

250

-

-

... More
Providing and laying cutting edge of mild steel weighing 40 kg per metre for well foundation complete as per drawing and technical specification

11.52

-

-

... More
Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification Well curb RCC M25 Grade

215.23

-

-

... More
Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification Well steining RCC M25 Grade

2870.592

-

-

... More
Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification Bottom Plug PCC Grade M25 Using Concrete Mixer

410.6

-

-

... More
Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification Top Plug PCC Grade M25 Using Concrete Mixe

73.876

-

-

... More
Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification Well cap RCC Grade M25 Using concrete Mixer

452.855

-

-

... More
Sinking of 6 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level.(i) Upto 3m depth

18

-

-

... More
(ii) Beyond 3m upto 10m depth

42

-

-

... More
(iii) Beyond 10m upto 20m

59.612

-

-

... More
(iv) Beyond 20 m up to 30 m

2.067

-

-

... More
Sinking of 7 m external diameter well ( other than pneumatic method of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level. (i) Upto 3m depth

12

-

-

... More
(ii) Beyond 3m upto 10m depth

28

-

-

... More
(iii) Beyond 10m upto 20m

32.319

-

-

... More
Sand filling in wells complete as per drawing and technical specifications

2435.587

-

-

... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications

187.693

-

-

... More
Supplying, fitting and placing un-coated Mild steel reinforcement complete in foundation as per drawing and technical specification

0.6

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 : Nominal mix 1:3:6

91.088

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203, PCC Grade M25

1299.144

-

-

... More
Supplying, fitting and placingTMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202

96.342

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 Nominal mix (1:2.5:5)

14.56

-

-

... More
Super-structure (LSB)

-

-

-

... More
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification Technical Specification RCC/PSC Grade M35 Case - I : Using Concrete Mixer

1719.8

-

-

... More
upplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

278.915

-

-

... More
High tensile steel wires/strands including all accessories for stressing, stressing operations and grouting complete as per drawing and

45.5

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

207.537

-

-

... More
Construction of RCC Railing of M25 grade in cast in situ with 20mm nominal size aggregate, true line and grade

543.12

-

-

... More
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their author

124.3

-

-

... More
Supplying, fitting and fixing in position true to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications

6147.576

-

-

... More
Supplying, fitting and fixing in position true to line and level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2003 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.

6147.276

-

-

... More
Drainage spouts complete as per drawing and technical specifications Clause 1209

216

-

-

... More
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211

99.006

-

-

... More
Providing steel R.S.Js/built-up steel sections including cutting, welding/rivetting, hoisting, fixing in position for composite girders with shear connectors complete with painting as per drawing and technical specifications Clause 1205.6 Steel section

458.842

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M 25

358.547

-

-

... More
Providing fitting and fixing mild steel railing complete as per drawing and technical specifications Clause 1208.2

633.92

-

-

... More
Providing and laying a buried expansion joint, covered with 12 mm thick, 200 mm wide galvanised weldable structrual steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia, 100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, as per technical specifications Clauses 1207.2.3

9.9

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

337

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I) Granular material

1329.95

-

-

... More
Providing and inserting dowels bars of 25 mm dia (TMT) to a depth of 400 mm anchored in the hard rock by grouting with cement slurry, as per specification and making good all complete as directed.

86

-

-

... More
SH: LSB Protection Works :

-

-

-

... More
Providing & laying of boulder apron laid in wire crates with 14mm dia GI wire conforming to IS : 280 in 100 mm x 100mm mesh (woven diagonally) including 10% extra for laps 7 joints laid with stone boulder weighing not less than 25 Kg each as per drawing

976.199

-

-

... More
Providing and laying Pitching on slopes laid over prepared Filter media asper drawing and technical specifications clause 1302 I. Stone Boulder

752.526

-

-

... More
Providing and laying Filter material underneath Pitching in slopes complete asper drawing and technical specifications clause 1302

976.199

-

-

... More
Routine Maintenance

-

-

-

... More
First Year

-

-

-

... More
Second Year

-

-

-

... More
Third Year

-

-

-

... More
Fouth Year

-

-

-

... More
Fifth Year

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.