Pradhan Mantri Gram Sadak Yojana Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date23 Sep 2024
Closing Date7 Oct 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Mrl02-delinge To Kembing Village Pmgsy Road

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation in ordinary rock using mechanical means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.

3033.23

-

-

... More
PAVEMENT

-

-

-

... More
SHOULDER: Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.

2531.25

-

-

... More
GRANULAR SUB-BASE: Granular Sub-base with Well Graded Material (Table 400.1) (A)By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing bymix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (i) For Grading I Material

2230.22

-

-

... More
WBM 3 FOR BASE COURSE ( 75 mm thick) : Providing, laying, spreading and compacting stone aggregates of specificsizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.

1067.18

-

-

... More
CELL FILLED CONCRETE PAVEMENT( 100 mm thick): Construction of plastic cel filled cement concrete pavement, with M30 gradeconcrete, thickness as per design, over a prepared sub base with 53 gradeOrdinary Portland Cement (OPC) or any other type as per Clause 1501.2.4 M30 (Grade). Coarse and fine aggregates conforming to IS :2386, maximum in a concrete mixer of not less then 0.2 cum capacity and appropeiate weigh batcher using approved mix design(As periRC 44-2088, laid in approved fixed side fomwork (steel channe, wedges, steel plates incuding leveling the fomwork as per drawing).spreading the concrete with sholvels, rakes, cnpaced using screed and plate vibrators and finished in continuous operation,.Concrete should have a slump of 30-50MM with use of approved plasticizer if reauiredFormwork of plastic cels should be made of High Density Polyethylene (HDPE), sheets having thickness ranging from 0.20-0.22MMwith sides 150MMx150MM and height as fxed by engineer in charge. To be laid in ful widfth of the carriageway.Iron spikes of about 200MM long are to be used to keep the cell walls taut. Nylon thread or rope may be used to prevent collase of cells during placement of concrete. Iron spikes to be taken out for use in other place as soon as the concrete is in place.The subbase should be provided with concrete/stone block or brick on edge on either side of the carriageway protecting the subbase with full thickness of the concrete poavement for its confinement and protection. curing of concrete slabs for 14 - days, curing compound (where specified) and water finishing to lines and grade as per drawing andTechnical Specification of cell flled Concrete Pavement Published by NRRDA.

19125

-

-

... More
HPC : 3 Nos.

-

-

-

... More
Earthwork in excavation for foundation of structures upto 3 m depth as per drawing and technical specification Clause 1104 includding setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.

204

-

-

... More
Plain Cement Concrete M10 (1:3:6 nominal mix) in levelling course below open foundation of Head walls as per drawings & Technical Specification Clause 1109

11.16

-

-

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets as per Clause 1106. [1000 mm dia]

22.5

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

66.87

-

-

... More
CD WORKS:- 1.5m, 2.00m & 4.m-1No

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth

455.56

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 [Hand Mixing]

43.12

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed Rubble masonry ( 2nd sort ) In 1:4 cement mortar

220.81

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed Rubble masonry ( 2nd sort ) In 1:5 cement mortar

186.96

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 With Granular material

591.58

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7

56

-

-

... More
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. For design mix RCC M 20

51.47

-

-

... More
Stone masonry in cement mortar 1:3 for parapet Complete as per drawing and technical specifications Clauses 700 and 1208.4 Coursed rubble masonry (1st sort)

9.35

-

-

... More
Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and technical specification Clauses 615, 710 and 1204.3.11

19

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

0.61

-

-

... More
Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202

2.13

-

-

... More
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302

1.22

-

-

... More
Providing and laying curtain walls complete as per drawing and technical specification Clause 1304 Cement concrete grade M 10

3.51

-

-

-

-

-

... More
Earth work in excavattion for foundation of structure as per drawing and technical specification clause 307 i/c setting out construction of shoring and bracing deleterious matter, dressing of sides and bottom and backfilling with approve materials(By manual means)

2250

-

-

... More
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 a) Nominal mix 1:3:6

60.6

-

-

... More
Providing and laying plain cement concrete M15 grade. Nominal mix

24.78

-

-

... More
Plastering with cement mortar 1:4

274.82

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. (I) Random Rubble masonry (i) In 1:4 cement mortar

74.88

-

-

... More
Cement Plaster 15 mm thick 1:4 on stone masonry

1

-

-

... More
Neat cement punning

57.12

-

-

... More
PROTECTION WALL

-

-

-

... More
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.Ordinary soil Upto 3 m depth

364.8

-

-

... More
Stone masonry in cement mortar for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Coursed Rubble masonry ( 2nd sort ) In 1:5 cement mortar

298.55

-

-

... More
Stone masonry for substructure complete as per drawing & technical specification Clauses 702, 704, 1202 and 1204 Dry rubble masonry (1st sort)

240.88

-

-

... More
ROADS SIGNS & STONES

-

-

-

... More
Providing and fixing of typical PMGSY Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and fixing of typical PMGSY Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2

43

-

-

... More
Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001.

-

-

-

... More
Diversion one km ahead

2

-

-

... More
Road ahead closed

6

-

-

... More
Men at work

6

-

-

... More
Road closed

6

-

-

6

-

-

6

-

-

... More
Kilometre Stone

-

-

-

... More
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703

-

-

-

... More
i) Ordinary Kilometer Stone (Precast)

6

-

-

... More
First Year

1

-

-

... More
Second Year

1

-

-

... More
Third Year

1

-

-

... More
Fourth Year

1

-

-

... More
Fifth Year

1

-

-

... More
INCLUDING GST

-

6358145

-

... More
INCLUDING GST

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.