Pradhan Mantri Gram Sadak Yojana Tender

BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Pradhan Mantri Gram Sadak Yojana - PMGSY Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date23 Sep 2024
Closing Date7 Oct 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Mrl01-pha Kuwa To Rai Balo Village

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
WBM 3 FOR BASE COURSE ( 75 mm thick) : Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fillup the intersices of coarse aggregate,watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.(a)By Manual means.

1

-

-

... More
PRIME COAT: Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 [Low porosity]

1

-

-

... More
Tack coat:Providing and applying Tack Coat with Bitiminous [RS - I] using emulsion distrubuter @ 0.25 to 0.30 Kg per Sqm. On prepared dry and hungry bituminus surface clean with hydraulic broom as per technical specification 503.

1

-

-

... More
Mix Seal Surfacing 25 mm thickness: Mix Seal Surfacing : Providing, laying and rolling of close-graded premix surfacing material of 25 mm thickness composed of 11.2 mm to 0.9 mm (Type-A) or 13.2 mm to 0.9 mm (Type-B) aggregates using penetration grade bitumen to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 8-10 kN static roller and finishing to required level and grades as per Technical Specification Clause 509

1

-

-

... More
CD WORKS:- 1.5m, 2.00m & 6.00m:- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.

1

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)

1

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. II) Coursed Rubble Masonry (First sort) ii) In 1:4 Cement mortar.

1

-

-

... More
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. II) Coursed Rubble Masonry (second sort) ii) In 1:4 Cement mortar.

1

-

-

... More
Back filing behind the Abutment, wing wall and return wall complete as per drawing and technical specifications ,clause 1204.3.8 Granular materials

1

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

1

-

-

... More
Providing and laying reinforced cement concrete in super structure as per drawing and specification clause -800 , 1205.4 & 1205.5 ( RCC M25).

1

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (R.C.C grade M 20) Abutment Capping

1

-

-

... More
Supplying fitting and placing HYSD bar reinforcement(Fe415) in superstructure complete as per drawing and technical specification.Clause -1002,1010 &1202 (as per RRM plate No. 7.08)

1

-

-

... More
Providing concrete for plain concrete for superstructure complete as per drawings and technical specifications Clause 1303.3(PCC grade M10) For coping of return wall

1

-

-

... More
Plain/reinforced cement concreete in substructure as per drawing and techanical specification Clauses 802,804,805,806,807,1202 and 1204 (RCC grade M20) a. For end pillars

1

-

-

... More
10 METRE RCC MINOR BRIDGE: Earthwork in excavation for structures as per drawing and Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable materialtechnical specification Clause 305.( for drain & CD 1.50 mtr) Ordinary soil Upto 3 m depth

1

-

-

... More
Providing concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 (PCC grade M10)

1

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 P.C.C grade M 15 [Nominal mix 1:2.5:5(Hand mixing)]

1

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C grade M 20

1

-

-

... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing

1

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 (i) Granular material

1

-

-

... More
Supplying, fitting, and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications Clauses 1002, 1005,1010 and 1202

1

-

-

... More
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) Section IX complete, including all accessories as per drawings and technical specification Clause 1207.1

1

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 25 [for height upto 5Mtr]

1

-

-

... More
Drainages spouts complete as per drawing and technical specification clause 1209.

1

-

-

... More
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3

4.79

-

-

... More
Providing and laying a buried expansion joint, covered with 12 mm thick, 200 mm wide galvanised weldable structrual steel plate as per IS:2062, placed symmetrical to centre line of the joint, resting freely over the top surface of the deck concrete, welding of 8mm dia, 100mm long galvanised nails spaced 300mm c/c along the centre lne of the plate. as per technical specifications Clauses 1207.2.3

12

-

-

... More
Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.

12

-

-

... More
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3

45.6

-

-

... More
R&B WALL: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trnches with excavated suitable material.

6007.35

-

-

... More
Plain/ reinforcement cement concrete in sub structure complete as per drawing and technical specification clauses 802,804,805,806,807,1202 and 1204 PCC grade M15 nominal mix 1:2.5:5

320.8

-

-

... More
Stone masonry ( second sort) with hard stone in foundations and plinth as per drawing and techanical specifications Clauses 702,704,1202&1203 in cement mortar 1 : 3 (1 cement : 3 fine sand).(CRM)

1519.12

-

-

... More
Providing weepholes in stone masonary RCC work, wing wall etc 100 dia AC pipe extending through the full width of the structures with slope of 1(V) :20(H) towards drawing face complete as per drawing and techanical specification Clauses 614,709.1204.3.7

1057

-

-

... More
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 [Granular material]

796.64

-

-

... More
KUTCHA DRAIN: Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. a. Ordinary Soil

5325.05

-

-

... More
b. Ordinary Rock

5325.05

-

-

... More
PUCCA DRAIN:- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. (i) Upto 3m depth

261

-

-

... More
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 803, 1202 ans 1203 [M -15 Plain base concrete]

52.2

-

-

... More
Stone Masonry work in cement mortar in foundation complete as per drawings and technical specification Clauses 702,704,1202 & 1204 [CRM in CM 1:5]

83.52

-

-

... More
Cement plaster 15 mm thick 1:4 on stone masonry

1067.2

-

-

... More
Road Signage: Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 a). Ordinary 1 Km-stone (size - 66 X 35 X 25 cm)

20

-

-

... More
b) 5th Km. Stone (size 107.50x58x25cm)

4

-

-

... More
c) 200m stone (precost)

100

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

36

-

-

... More
Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on 2 inch dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701

36

-

-

... More
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6 mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1

2

-

-

... More
Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed foundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2

40

-

-

... More
Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704

120

-

-

... More
Providing and Fixing VVP Logo Board at starting point:Providing and fixing of typical VVP Logo board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting 15cmx15cmx260cm above G.L.),(Size of board 1x 85cmx85cmx7.5cm, ) incl.earth work,and lettering with appropiate colour with required shade of approved quality ready mix paint.

1

-

-

... More
Providing and Fixing Title information Board of Vibrant Village Programmet(RCC):Providing and fixing of typical VVP Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl.earth work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat, painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

2

-

-

... More
Providing and Fixing Citizen information Board of VVP Project(RCC)"A":Providing and fixing of typical VVP Citizen information sign board as per MORD specifications and drawing of cast-in-situ RCC,(Size of RCC post 25cmx25cmx90cm below G.L. & 15cmx15cmx245cm above G.L.),(Size of board 2x 90cmx80cmx7.5cm, ) incl. work, finishing with 15mm pluster 1:4 and neat cement punning, applying priming coat,painting and lettering with appropiate colour with required shade of approved quality ready mix paint.

3

-

-

... More
Safety Devices and Signs in Construction Zones:Provision and fixing of traffic signs for limited period at suitable locations in construction zone comprising of warning zone, approach transition zone, working zone and terminal transition zone with a minimum distance of 2-3 m from the edge of the carriageway. The bottom edge of the lowest sign plate to be not less than 2 m above the road level, fixed on 600 mm x 600 mm x 6 mm angle iron post, founded and installed as per approved design and drawings, removed and disposed of after completion of construction work, all as per IRC:SP:55-2001. a. Men at work

4

-

-

... More
b. Diversion

4

-

-

... More
c. Road closed

4

-

-

... More
d. Stop

4

-

-

... More
d. Slow

4

-

-

... More
e. Speed limit

4

-

-

... More
SETTING OUT : a] Reference benchmark and working bench mark

20

-

-

... More
b] Reference Pillar

20

-

-

... More
c] Back Pillar.

1001

-

-

... More
d] Job Pillar

160

-

-

... More
GUARD POSTS

200

-

-

... More
First Year

1

-

-

... More
Second Year

1

-

-

... More
Third Year

1

-

-

... More
Fourth Year

1

-

-

... More
Fifth Year

1

-

-

... More
INCLUDING GST

-

27901000

-

... More
INCLUDING GST

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.