Indian Army Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Indian Army - OSCC Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 Sep 2024
Closing Date16 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMY_669594_1Bid Award Id
ViewTender No
3052/Op Sad/PRITender Authority
Indian Army ViewPurchaser Address
-Website
http://https://www.indianarmy.nic.in/home
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
P/L PCC 1:4:8 for step
5.92
-
-
Reinforcement of RCC work i/ bending , footing and column
473.58
-
-
Centering and shuttering of footing, column and cc step
95.04
-
-
RCC work in foundation for footing base
5.83
-
-
RCC work in Columns
4.05
-
-
Steel work in single section of u-clamp, MS flat, T- clamp, L-clamp
1.94
-
-
P/F M.S bolts & nuts i/c washer, Uclamp, Ms Flat, T&L clamp
3.02
-
-
Provision for best available local wood (Class B-II) work in frame for floor beam, door frame, window frame, Tie, rafter K/post, strutt, purline, ceiling frame.
3.71
-
-
25mm thick plant flooring
146.06
-
-
25mm thick plant walling of Side wall.
131.17
-
-
P/F panelled glazed Or panelled and glazed shutter for door,window of 38 mm thick
5.67
-
-
P/F Best available local wood glazed shutter for door, window of 35 mm thick.
12.96
-
-
Prov CGI Sheet roofing of 0.50 mm thick
205.92
-
-
Prov ridge or hips 60cm overall
33.24
-
-
25mm thick plant walling but joint of hall, verandah
4.32
-
-
P/F 6mm Thick Plywood/Flase Ceiling of hall n verandah.
144.5
-
-
P/F Plain Square wooden beading 38*12mm of hall n verandah.
298
-
-
Providing and fixing Aluminium tower bolts anodised or with necessary screws etc complete
6
-
-
Providing and fixing Aluminium Handle with necessary screws etc complete
30
-
-
Providing and fixing Aluminium MS Hook and Eyes.
30
-
-
Providing and fixing EV Boards
52.64
-
-
Applying Primer Coat with ready mix Primer
299.6
-
-
Painting two or more coats(execluding primer coat)....
299.6
-
-
Sand and agregate estimate
100
-
-
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm as in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes
157
-
-
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm as in vertical surfaces such as skirting/dado, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 10mm thick rendering in cement mortar 1:4 complete all as specified & directed.
32
-
-
Material and labour for providing point wiring for controlled by one switch with using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable (Maintaining Colour Code) 1100 volts grade with and including PVC casing and capping (size of casing caping as required at site but not less than 20mm) of suitable size including PVC accessories / fittings and fixtures fixed on surface with using new PVC board or sunken type pressed steel box of adequate size, terminal boxes for mounting fittings/junction boxes with and including all accessories and using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable green in colour as in earth continuity conductor
connected to common earth dolly and connecting upto fittings complete all as specified
and directed for:- (a) One light /Fan /Ex Fan point controlled by one, one way switch
(b) One socket outlet 3 or 5 Pin, 6 Amp on independent board
55
-
-
All as per Ser item No 29.00 above but with 2.5 sqmm copper cable in and including PVC casing and capping complete all as specified and as directed.
10
-
-
S&F for switch paino flush type 6 Amps single pole one way 230 volts AC circuit complete all as specified and directed.
15
-
-
S&F for switch paino flush type 16 Amps single pole one way 230 volts AC circuit complete all as specified and directed.
5
-
-
S&F Electronic fan regulator 230 volts, step type, flush type, ISI Marked, complete all as specified and as directed.
4
-
-
M&L for ceiling rose, surface bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate, isolated body (ISI Marked) complete all as specified and as directed.
15
-
-
S&F LED tube light fitting 4 ft. 1 x 18/20 watt, 230 volts, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin core flexible copper conductor cable with suitable size,complete all as specified and directed.
16
-
-
Earthering
1
-
-
Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required ength and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to besuspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights as per specifications and as directed by Engineer – in - Charge.
135
-
-
M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation adacoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc, complete all as per manufacturer instructions complete all as directed.
135
-
-
S & F for aluminum powder coated (powder coated of required colour) three track (2 Nos Glazed shutter & 1 Nos Gauzed shutter) sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.75 x 1.50mm (Section of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass
27
-
-
S&F 30 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & fixed to chowkats of complete all as specified & directed.
15
-
-
M & L main switches, DBs, bus bars chambers including all fittings and fixtures ie MCBs all sizes etc omplete all as specified and directed.
3
-
-
Supply of DBs & SPN MCBs including all fittings and fixtures ie MCBs all sizes etc omplete all as specified and directed.
5
-
-
Transportation
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements