Indian Army Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Indian Army - OSCC Tender
Civil And Construction
Eprocure
Opening Date7 Sep 2024
Closing Date28 Sep 2024
Tender AmountRefer Documents
Costs
EMD
₹ 1,20,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARMY_672852_1Bid Award Id
ViewTender No
553/OP SAD/PRITender Authority
Indian Army ViewPurchaser Address
-Website
http://https://www.indianarmy.nic.in/home
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M and L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips. used TMT bars 12
1190.42
-
-
M and L for Mild steel bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders Use TMT bars 10
2074.11
-
-
M and L for RCC M 20 Design Mix 20mm graded aggregates in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete
25
-
-
Providing PCC 1:2:4 type B2 40 mm stone agg as in plinth protection 100mm thick finishing cement concrete even and smooth without using extra cement.
60
-
-
RCC M and L for RCC M 20 Design Mix 20mm graded aggregated in Columns, pillars, piers, post and struts
24.75
-
-
Use and Waste for work to sides of concrete foundations, bases of columns, raft and raft beams, sides and soffits if any of foundation and plinth beams and similar work, vertical or to batter in flat
51.84
-
-
Use and Waste form work to sides of pillars, posts, struts, piers, columns and stanchions
207.4
-
-
Use waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilever, shelves including sup ports, overhangs, etc, also splays between floors and beams, etc.
123.75
-
-
M and L for Brickwork with subclass B bricks, straight or curved on plan exc 6m mean radius built in CM 1:6
28
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft loose soil
51.03
-
-
Removing excavated material n exc 50m and depositing where directed at a level exc 1.5 m above the starting point
13.49
-
-
S and F for steel work in tubular trusses including special shaped washers etc complete using ERW or induction but welded tubes conforming to IS 1161 1979 grade SI 240
2500
-
-
S and F Pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering cladding to wall, fixed with self tapping screws as specified.
495.36
-
-
S and F Pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall, fixed with self tapping screws as specified.
53.12
-
-
M and L for rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 with water proofing compound complete as specified and directed
345.29
-
-
M and L for rendering 15 mm thick on other than fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish.
61
-
-
Supply only integral waterproofing compound
104
-
-
M and L for two coats of cement base paint over one coat of white wash on newly plaster surface of walls including preparation of newly surface.
345.29
-
-
M and L for preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
46.14
-
-
M and L for 75 mm thick PCC 1:3:6 type C 2 Using 40 mm graded aggregate as sub base in floor
359
-
-
M and L for Sand filling under floors or in foundations including watering and consolidation
25.4
-
-
M and L for Polythene film, 150 micron thick, laid on a coat of bitumen primer, 0.30 to 0.50 kg per sq. m all as specified and directed.
359
-
-
M and L for Non skid ceramic coloured tiles 7 to 8mm thick square rectangular area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm in floor ,over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed.
359
-
-
M and L for 4 mm thick non AC E Board of size 595 into 595mm fixed in ceilings and applying one coat of distemper oil emulsion including preparation complete all as specified and as directed
359
-
-
Wiring for light point fan point exhaust fan point call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
6
-
-
Supply and fixing 5 oblique 6 amps switch piano type on the existing switch box cover including connections etc. as required.
6
-
-
Supply and fixing 3 pin, 5 amp ceiling rose on the existing junction box wooden block including connection etc as required.
2
-
-
Installation, testing and commissioning of LED FLOOD LAMP 100WATT, complete with all accessories and tube lamp etc. directly on ceiling wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
4
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required 8 ways. But without MCB RCCB Isolator
1
-
-
Supply and fixing 5 amps to 32 amps rating, 240/ 415 volts, C curve, miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1
-
-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as requiredof 40 amps
1
-
-
Supply and fixing 3 pin 5 6 amp socket outlet piano type on the existing switch box cover including connections etc. as required.
6
-
-
Wiring for circuit submain wiring along with earth wire 2 2.5 sq. mm 1 2.5 sq. mm earth wire of FR PVC insulated copper conductor, single core cable in surface recessed medium class PVC conduit as required
50
-
-