Department Of Town Planning And Urban Local Bodies Tender

... More
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.

Department Of Town Planning And Urban Local Bodies Tender

Eprocure
Opening Date29 May 2021
Closing Date18 Jun 2021
Tender Amount₹ 97,95,01,538 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres).By Mechanical Means for items No. 202( b) & ( c) Cement Concrete Grade M-15 & M-20

1052.5

-

-

... More
Removing all type of hume pipes and stacking within a lead of 1000 metres including earthwork and dismantling of masonry works. Up to 600 mm dia

2034

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately).By Mechanical Means Bituminous courses

7276.78

-

-

... More
Dismantling Kerb Stone channel (Dismantling kerb stone channel by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre)

2034

-

-

... More
Removal of Telephone / Electric Poles and Lines (Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately)

452

-

-

... More
Excavation in Ordinary Rockusing Hydraulic ExcavatorCK-90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)

33875.79

-

-

... More
Construction of Embankment with Material Deposited from Roadway cum 133.00 Cutting (Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2)

11754.09

-

-

... More
Granular Sub-base with Close Graded Material (Table:- 400-1) By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) (i) for grading- I Material

13638.15

-

-

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.)

9657.12

-

-

... More
Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.)

165555.18

-

-

... More
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade.

164212.82

-

-

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing)

20594.06

-

-

... More
Construction of Median and Island with Soil Taken from Roadway Cutting (Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other tructures, spread, graded and compacted as per clause 407)

314

-

-

... More
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) A) Using Concrete Mixer

44486

-

-

... More
Granular Sub-base with Close Graded Material (Table:- 400-1) By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) for grading- I Material

9358.2

-

-

... More
Providing SUN ROCK HIGH CTS/DEVI paver block/tiles of concrete grade M30 or above of approved quality, size, shape of specified thickness over a leveling bedding layer of 30mm compacted sand over a base course of WBM or PCC (base course to be paid separetly) including cutting where necessary finished spreading, sweeping jointing sand and compacting the pavers using vibrating compactor as specfied and directed. 60mm thick

41630

-

-

... More
Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.

4302.9

-

-

... More
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.

29557.6

-

-

... More
Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) A) Using Concrete Mixer

13020

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

963.38

-

-

... More
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.

563.06

-

-

... More
Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth

99.17

-

-

... More
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth

55.16

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : Foundation, footings, bases of columns etc. and mass concrete.

288.75

-

-

... More
Brick work with best available local bricks in foundation and plinth in cement mortar 1:3 (1 cement : 3 fine sand).

175.62

-

-

... More
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).

6259

-

-

... More
Precast R.C.C. grating with frame 500x450 mm horizontal grating

550

-

-

... More
Fixing R.C.C. grating

550

-

-

... More
PVC blind pipe 150 mm dia as per IS: 12818

1100

-

-

... More
Fixing PVC Pipe

550

-

-

... More
Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing)

26.73

-

-

... More
Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retroreflectorised sign asper IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing)

108.92

-

-

... More
Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work (Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control ) a) Over 10 cm in width

30325

-

-

... More
Up to 10 cm in width

35258.85

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) Solid Lines in White Colour

8194.9

-

-

... More
Brocken Lines in White Colour

1501.2

-

-

... More
Stop Lines in White Colour

136.95

-

-

... More
Applying Zebra Crossing

600.1

-

-

... More
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paintin all shades on new plastered concrete surfaces) For Kerb stone painting

173

-

-

... More
Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, dia cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973

24283.33

-

-

... More
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)Ordinary soil, Manual Means

4398.21

-

-

... More
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications PCC Grade M15

291.91

-

-

... More
RCC Grade M30 Using Concrete Mixer

270.75

-

-

... More
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications

24.37

-

-

... More
Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications.RCC Grade M30 Height upto 5m, Using concrete Mixer

1441.2

-

-

... More
Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and technical specifications

144.12

-

-

... More
Tubular Steel Railing on Precast RCC posts, 1.2 m high above ground level (Providing, fencing and erecting 50 mm dia painted steel pipe railing in 3 rows on precast M20 grade RCC vertical posts1.8 metres high (1.2 m above GL) with 3 holes 50 mm dia for pipe, fixed 2 metres centre to, complete as per approved drawing)

374

-

-

... More
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit.) Girth from 300 mm to 600 mm

60

-

-

... More
Girth from 600 mm to 900 mm

60

-

-

... More
Girth from 900 mm to 1800 mm

60

-

-

... More
Clearing Grass and Removal of Rubbish

2.5

-

-

... More
Clearing and Grubbing Road Land .(Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.) By Mechanical Means, In area of light jungle

1.47

-

-

... More
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres). By Mechanical Means for items No. 202( b) & ( c) Cement Concrete Grade M-15 & M-20

248

-

-

... More
Removing all type of hume pipes and stacking within a lead of 1000 metres including earthwork and dismantling of masonry works. Up to 600 mm dia

240

-

-

... More
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately). By Mechanical Means,Bituminous courses

343.28

-

-

... More
Dismantling of Cement Concrete Pavement (Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately)

950.1

-

-

... More
Dismantling Kerb Stone channel (Dismantling kerb stone channel by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metre)

240

-

-

... More
Dismantling of Fencing (Dismantling of barbed wire fencing/ wire mesh fencing including posts, foundation concrete, back filling of pit by manual means including disposal of dismantled material with all lifts and up to a lead of 1000 metres, stacking serviceable material and unserviceable material separately. )

1079.73

-

-

... More
Dismantling of CI Water Pipe Line (Dismantling of CI water pipe line 600 mm dia including disposal with all lifts and lead upto 1000 metres and stacking of serviceable material and unserviceable material separately under supervision of concerned department)

800

-

-

... More
Removal of Telephone / Electric Poles and Lines (Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately)

53

-

-

... More
Excavation in Ordinary Rock using Hydraulic Excavator CK-90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead upto 1000 m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.)

33599.7

-

-

... More
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)

11051.91

-

-

... More
Granular Sub-base with Close Graded Material (Table:- 400-1) By Mix in Place Method (Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) for grading- I Material

1612.33

-

-

... More
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.)

1189.75

-

-

... More
Preparation of sub grade (Preparation of sub grade by excavating earth to an average depth of 22.50 cm, dressing to camber and consolidating with road roller, making good the undulations etc. and disposal of surplus earth, lead upto 50 m.)

12383.34

-

-

... More
Consolidation of sub-grade with road roller of 8 to 12 tonne capacity including making good the undulations etc. with earth or quarry spoils etc. and rerolling the sub grade.

14327.34

-

-

... More
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )

2105.17

-

-

... More
Construction of Median and Island with Soil Taken from Roadway Cutting (Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other tructures, spread, graded and compacted as per clause 407)

170.95

-

-

... More
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408). Using Concrete Batching and Mixing Plant

10510.45

-

-

... More
Prime coat (Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical means.)

1044

-

-

... More
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom.

1044

-

-

... More
Dense Graded Bituminous Macadam (Providing and laying dense bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects.) (ii) for Grading II (19 mm nominal size)

73

-

-

... More
Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects) ii) for Grading-II(10 mm nominal size)

42

-

-

... More
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflector is ingglassbeads@250gms per sqm area,thickness of 2.5mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) Solid Lines in White Colour

48

-

-

... More
Road Markers/Road Stud with Lense Reflector (Providing and fixing of roadstud 100x 100 mm, die cast in aluminium, resistantto corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973)

80

-

-

... More
Providing and Layng light duty non-pressure NP2 Class RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement : 2 fine sand) including testing joints etc complete.

63

-

-

... More
Horticulture works

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal andstacking of serviceable materials and then disposing of surplus soil, byspreading and neatly levelling within a lead of 50 m and making up thetrenched area to proper levels by filling with earth or earth mixed withsludge or / and manure before and after flooding trench with water (excludingcost of imported earth, sludge or manure).

3378.81

-

-

... More
Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).

844.7

-

-

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).

281.57

-

-

... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 km lead complete (manure measured in stacks will be reduced by 8% for payment) :

422.35

-

-

... More
Rough dressing the trenched ground including breaking clods.

5631.35

-

-

... More
Fine dressing of the ground.

5631.35

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

1548.62

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge

1548.62

-

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure orextra earth to be paid for separately)

632.75

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavatedearth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts ofstacked volume of earth after reduction by 20% : 1 part of stacked volumeof manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost ofmanure, sludge or extra good earth if needed to be paid for separately). Holes 90 cm dia, and 90 cm deep

2277

-

-

... More
Half brick circular tree guard in bricks, internal diameter 1.25 metre and height 1.2 metre above ground and 0.20 m below ground, bottom two courses laid dry and top three courses in cement mortar 1:6 (1 cement : 6 fine sand) and the intermediate courses being in dry honey comb masonry as per design complete: With common burnt clay F.P.S. (non modular) bricks of class designation 5.0

2277

-

-

... More
Complete maintenance of trees (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department and other T & P material/articles shall be provided by the contractor) and as per direction of officer in charge. Trees for 1200 no (beyond 8 year Slow & beyond 6 Fast growing group)

136620

-

-

... More
Complete maintenance of shrubs (Out side garden features), jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc, (excluding the cost of material which shall be supplied by the department) and as per direction of officer in charge.

143297

-

-

... More
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water) Trees Plant

2277

-

-

... More
Hedge Plant /Ground cover

67169.18

-

-

... More
Shrubs Tecoma gaudichaudi

408.92

-

-

... More
Thevetia nerifolia

408.92

-

-

... More
Nerium oleander (kaner)

785.22

-

-

... More
Tabernaemontana coronaria

785.22

-

-

... More
Duranta golden

12001.2

-

-

... More
Clerodendrum inerme

7065.11

-

-

... More
Wedelia trilobata

13167.66

-

-

... More
Alternanthera species red

7994.48

-

-

... More
Alternanthera species green

4006.72

-

-

... More
Ophiopogon black

6102.55

-

-

... More
Ophiopogon green

7221.59

-

-

... More
Tradescantia

7221.59

-

-

... More
Jacaranda mimosifolio

496.67

-

-

... More
Cassia fistula

281.67

-

-

... More
Kigelia pinnata

179.67

-

-

... More
Alstonia scholaris

345

-

-

... More
Delonix Regia

162.67

-

-

... More
Michelia champa

318.67

-

-

... More
Ficus benjamina

243.33

-

-

... More
Erythrina indica

249.33

-

-

... More
Electrical Works

-

-

-

... More
Supply , installation testing and commissioning of outdoor type external lighting feeder pillar of suitable size made out of M.S. sheet 2mm thick (14 SWG) duly compartmentalized, double door with locking arrangement (IP-65), duly fixed on MS angle iron frame work of size 50mm x 50mm x 6mm, 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) and having following accessories mounted inside the cubical panel i/c connection, inter connection with aluminium thimbles, earthing with two nos. earth struds duly painted with power coating and 9 tank process of approved shade complete etc. as required. Smart feeder Panel-10kVA-10kVA rated Switching point controller system (SPCS) with GPRS, Timer, Energy measurement systems and switching controllers with outgoing as required to feed 32 luminaires for individual control of luminaire.

39

-

-

... More
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, unarmoured/Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 laid in air or through existing cable trench/ duct/ cable tray/ HDPE pipe including fitting required size of lugs at the both end of the cable by using crimping tool and making good damaged done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make). 25 Sq.mm four core armoured cable

45974.6

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm

31158.6

-

-

... More
Supply Installation, testing and commissioning of LED Luminaire 180W for streetlight application with Dimmable driver and integrated SLC including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.

726

-

-

... More
Supply Installation, testing and commissioning of LED Luminaire 150W for streetlight application with Dimmable driver and integrated SLC including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.

102

-

-

... More
Supply Installation, testing and commissioning of LED Luminaire 120W for streetlight application with Dimmable driver and integrated SLC including connection with 3x1.5 sqmm flexible fire retardant copper connecting wire of required length complete as required for outdoor application.

348

-

-

... More
Supply of Hot-Dip Galvanized conical 9m height Poles for Street Lighting with decorative brackets, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec.

1176

-

-

... More
ITC of Hot-Dip Galvanized conical 9m height Poles for Street Lighting with decorative brackets, arrangements, including suitable boards, bakelite sheet , MCBs and 20mm dia 1.5m long MS rod earthing as per IS specifications suitable to withstand the wind speed of 47 m/sec. including civil foundation , sleeves, excavation and back filling complete in all respect with all required accessories.

1176

-

-

... More
Web application charges per luminaire & on cloud hosting (annual subscription)

1176

-

-

... More
SMS Alerts Charges (Yearly – for 50,000 SMS),

2

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

745

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

873

-

-

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

31953.23

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)

31027.23

-

-

... More
Supplying, installation, testing and commissioning of IP Based CCTV system for building security comprising of PTZ Fixed camera, cabling, recording , display system and hard ware software support. Note: Rate includes peripheral IP Based PTZ camera besides indoor camera at reception, corridors, lift lobby etc., wiring upto CCTV room and setting up monitoring unit/ units, as required. per sqm.(for external surveillance of plot area)

200761

-

-

... More
RCC Drain

-

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

37916.96

-

-

... More
Providing coarse sand in foundation in layer of 7.5 cm.

1059.86

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

1059.86

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works upto plinth level.

5987.39

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

54521.97

-

-

... More
(ii)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

11035.92

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. Tar/ TMT steel

475508.57

-

-

... More
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres) II By Mechanical Means B) Prestressed / Reinforced cement concrete grade M-20 & above

557.76

-

-

... More
LANDSCAPE FALL

-

-

-

... More
Clearing and Grubbing Road Land. (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.) By Mechanical Means, In area of light jungle

0.18

-

-

... More
Dismantling of CI Water Pipe Line (Dismantling of CI water pipe line 600 mm dia including disposal with all lifts and lead upto 1000 metres and stacking of serviceable material and unserviceable material separately under supervision of concerned department)

120

-

-

... More
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.

65.28

-

-

... More
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.

6.68

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). Below Plinth Level

28.55

-

-

... More
Above Plinth Level

30.82

-

-

... More
Reinforcement of RCC work including bending, binding and placing in position complete. Tar/ TMT steel

4749.12

-

-

... More
Centring and shuttering including strutting, propping etc and removal of form work for : (i) Foundation, footings, bases of columns etc. and mass concrete.

180

-

-

... More
(ii) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.

46.08

-

-

... More
(iii)Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).

86.4

-

-

... More
Random Rubble masonary in cement mortor 1:6 (including OH & CP)

22.9

-

-

... More
Pointing on stone work with cement mortar 1 : 3 (1 cement : 3 fine sand) Raised and Cut pointing

54.72

-

-

... More
Demolishing cement concrete 1 : 3 : 6 or richer mix including disposal off material within 50 metres lead.

2

-

-

... More
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).

40.32

-

-

... More
Providing and laying damp proof course 25 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm nominal size).

66.24

-

-

... More
Electrical Works

-

-

-

... More
SITC of polycarbonate weather proof (IP- 65) outdoor type junction box with required MCB and timer for controll of waterfall lights  including 2nos 600mm long spike to mount it 150mm above ground including terminal/connector block as required by site incharge.

1

-

-

... More
Supply of following size Aluminium conductor , XLPE Insulated, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988 . - 10Sq.mm 2 core cable

150

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE  power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. - Upto 35 Sq.mm

150

-

-

... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)

150

-

-

... More
SITC of 10W under water LED RBG surface lights for water wall pond with IP 68 enclosure and with required control and fixture control wiring.

60

-

-

... More
SITC of pool water LED RBG strip light of length 5.4 meters of waterfall width for 12 levels of water levels

12

-

-

... More
Random Rubble Maonry

-

-

-

... More
Random Rubble masonary in cement mortor 1:6 (including OH & CP)

1561.5

-

-

... More
Pointing on stone work with cement mortar 1 : 3 (1 cement : 3 fine sand) a) Flush Pointing

4592.5

-

-

... More
IIT VETTING

-

-

-

... More
Cost of vetting of Concrete Design Mix from IIT

1

-

-

... More
SURVEY WORKS

-

-

-

... More
Topographics Survey

1

-

-

... More
Geo-Technical Survey

1

-

-

... More
LABORATORY ESTABLISHMENT

-

-

-

... More
Cost of Laboratory Establishment

1

-

-

... More
OPEX Operation and Maintenance (O&M) for of Smart Roads, Street Lighting, Arboriculture & CCTV Surveillance

-

-

-

... More
YEAR -01

1

-

-

... More
YEAR -02

1

-

-

... More
YEAR -03

1

-

-

... More
YEAR -04

1

-

-

... More
YEAR -05

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.