Department Of Power Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Department Of Power - DOP Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Jul 2023
Closing Date23 Sep 2023
Tender Amount₹ 3,42,69,21,400 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,71,34,607Document Cost
₹ 17,700Tender Fee
Refer Documents
Summary
Rdss Under Miao
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_DOP_1326_1Bid Award Id
ViewTender No
MED/487-502Tender Authority
Department Of Power ViewPurchaser Address
-Website
http://arunachaltenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Designing, Fabrication and supply of 7.50 M Long off 410 SP-09 steel tubular poles confirming to IS 2713 (Part 1 ) 1980
3776
-
-
11 KV, 3 Wire, 2.8 m long cross arm made of MS Channel of size 125x 50 x 6 mm complete etc.
701
-
-
11 KV 'Y' - Type cross arm made of Angle of size 50 x 50 x 6 mm in radial structure of 3 arms of 0.8 m long 120° apart complete etc.
949
-
-
Angle bracing set 3.1 m long of size 65 x 65 x 6 mm complete with accessories nut / bolts etc.
701
-
-
MS Channel of size 100 X 50 X 4.7 mm for Air Break switch top bracket transformer mounting and Drop Out fuse (8 X 2 = 16 m) i/c nuts and bolts.
262
-
-
Suspension clamp assembly with eye hook and 2 nos MS Half Round clamp for suspending eye-hook with 3 nos nuts and bolts in complete set
12562
-
-
Dead end clamp with eye hook and 2 nos MS Half Round clamps for suspending eye-hook with 3 nos nuts and bolts in complete set
4188
-
-
Insulated connectors with covers
31405
-
-
Manufacturing and supplying of GI earth clamps.
4616.84
-
-
3Ph Distribution Box with associate accessories complete to connect household services as required.
7853
-
-
Manufacture and supply of Stay Set (Galvanised) with 50x8 mm stay clamp, stay insulator (2 Nos.), MS anchor plate (300mmx300mmx5mm), nut bolts, 2 Nos turn-buckles, 1.8 m long, 18 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
3542
-
-
11 KV polymer Disc insulator 45 KN
4995
-
-
11 KV polymer Disc insulator 45 KN hardware fittings
4995
-
-
11 KV Polymer Pin Insulators with GI PIN
5738
-
-
40 mm dia., 4.5m long GI pipe earth electrode with GI wire for pole earthing including salt charcoal and other accessories complete
2992
-
-
8 SWG GI wire
48.74
-
-
11 KV, 3.1 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm Complete etc
528
-
-
Copper plate earthing of transformer CBS & Battery charger including cost of copper plate size 600 X 600 X 6 mm & copper strip of size 25 X 4 mm i/c salt, charcoal etc. as required.
262
-
-
FOR 100KVA : Supplying, fitting and fixing of chain link fencing of 8 SWG GI wire (50X50X5mm mesh) i/c corner and end post with MS angle of size 50X50X5mm and length not less than 1800mm intermideate post of MS angle of size 40X40X5mm and D length not less than 1800mm i/c supplying, fittings and fixing of hook, eyebolt with nuts, staples bolts etcas required with 3 horizontal line of GL wire 10swg at top middle and bottom and with one vertical line to each fencing tight and erect complete i/c the cost of primer, painting of MS angle iron post in PCC base etc and two cot of Al pain on foundation of cost with PCC works of 1:2:4 CC as per approved drawing.
1680
-
-
FOR 100KVA : Fabrication and Supply of standard size MS Gate as per approved drawing
140
-
-
6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
518.85
-
-
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
23.18
-
-
AERIAL BUNCHED CABLE 3 X 50 SQ.MM+1x25 SQ. MM.+1x16 SQ. MM.
194.13
-
-
AERIAL BUNCHED CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM.
64.89
-
-
AERIAL BUNCHED CABLE 3 X 120 SQ.MM. + 1x70 SQ. MM. +1x16 SQ. MM.
43.07
-
-
AERIAL BUNCHED CABLE 3 X 95 SQ.MM. + 1 x50 SQ. MM.+ 1x16 SQ. MM.
43.06
-
-
AERIAL BUNCHED CABLE 3 X 70 SQ.MM.+1 x50 SQ. MM.+ 1x16 SQ. MM.
193.95
-
-
Danger Plate of size 250 mm x 200 mm of thickness 3 mm. ( 11000V)
1375
-
-
Danger Plate of size 250 mm x 200 mm of thickness 3 mm. ( 415V)
3776
-
-
Anti climbing devices with G. I. thornwire / Barbed wires.
2881.5
-
-
Supply of red oxide paint & 2 coats of paints on poles / equipment / metal surfaces on full rate basis.
6653
-
-
11/0.433 KV Distribution Transformer 16 KVA 3 phase Aluminium wound DTR
2
-
-
11/0.433 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR
58
-
-
11/0.433 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR
62
-
-
11/0.433 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR
140
-
-
Manufacture and supply of Designing Manufacturing & supply of weather proof pole mounted LT Pannel Board with adequate ratings of MCCBs/RCBs, space duly provided or mounting DT Energy & service connection distribution board within the same panel.
262
-
-
Manufacture and supply of 11 KV Distribution Class Lightening Arrester for DT as per technical specification, approved drawings and scope of work.
786
-
-
Manufacture and supply of 11 KV, 50 HZ Air Break Switch conforming to IS : 9920 (Pt - I to IV) with rated voltage 12 KV & rated normal current shall be 400 Amps. Provided with bimettallic connector on the incomming side to accommodate ACSR of sizes 20, 30, 50 Sqmm on the outgoing side.
262
-
-
Manufacture and supply of Outdoor, drop out expulsion type of 11 KV drop out fuse suitable for insullation in 50 HZ, 11 KV distribution system confroming to IS : 9385 (Pt - I to III) with rated voltage shall be 12 KV & rated current shall be 400Amps provided with a suitable arrangement these on 100 X 50 X 6 MM channel cross arm.
262
-
-
3.5CX35 sqmm aluminium conductor cable
1800
-
-
3.5CX50 sqmm aluminium conductor cable
1860
-
-
3.5Cx120 sqmm aluminium conductor cable
4200
-
-
Supply and Installation of Pole mounted Signboard at Distribution Transformer Structure clearly representing about the work, date of commissioning, estimated cost, scheme, employer's details and rating in KVA (Specification same as Danger Plate of size 250 mm x 200 mm of thickness 3 mm.)
262
-
-
Manufacturing, supplying and installation of alluminium PG clamp
8044
-
-
Galvanized stay set complete with galvanised MS anchor plate of size 300 x 300 x 5 mm, anchor rod of length 1800 mm & dia 18 mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as required (of all sizes).
1256
-
-
Earthing with 40 mm dia GI pipe 4.5 mtr long with GI wire for pole earthing including salt charcoal etc. as reqd.
418
-
-
AAA Covered Conductors, 120sqmm
152.96
-
-
11KV Wedge Connector for bare to CC connection
297
-
-
IPC(for connecting 70 sqmm CC to CC)
297
-
-
Erection of Materials as per Scope of Works, Technical Specifications and Approved Drawing
-
-
-
9 M long Steel Tubular poles 410 SP-32
2353
-
-
10 M long Steel Tubular poles 410 SP-44
524
-
-
Erection of 7.5 m long of 410 SP-09 Steel single pole including excavation of pits in all kind of soil/rock complete foundation (including supply of foundation materials) , Top muffing , fixing of cross arm , pole top bracket, anticlimbing device and other accessories complete in all respect as per TS.
3776
-
-
11 KV 'Y' - Type cross arm made of Angle of size 50 x 50 x 6 mm in radial structure of 3 arms of 0.8 m long 120° apart complete etc.
248
-
-
Angle bracing set 3.1 m long of size 65 x 65 x 6 mm complete with accessories nut / bolts etc.
701
-
-
AERIAL BUNCHED CABLE 3 X 50 SQ.MM+1x25 SQ. MM.+1x16 SQ. MM.
194.13
-
-
AERIAL BUNCHED CABLE 3 X 35 SQ.MM.+1x25 SQ. MM.+ 1x16 SQ. MM.
64.89
-
-
Erection of GI earth clamps.
4616.84
-
-
Erection of suspension clamp, Dead end assembly with eye hook , insulated connector and others miscellaneous items required for completion of works
523.4
-
-
Excavation, erection, testing & commissioning of 40 mm dia., 4.5 m long GI pipe earth electrode with GI wire for pole earthing , Charcoal, Salt and other accessories complete
2978
-
-
Erection of 8 SWG GI wire for earthing and guarding by providing GI nut, bolts & washers, turn buckle etc
48.75
-
-
Erection of 11 KV, 3.1 m long Guard Bracket made of Channel of size 100 x 50 x 6 mm Complete etc
528
-
-
Copper plate earthing of transformer CBS & Battery charger including cost of copper plate size 600 X 600 X 6 mm & copper strip of size 25 X 4 mm i/c salt, charcoal etc. as required.
262
-
-
FOR 100KVA : Fitting and Fixing and Fabrication of standard size MS Gate as per approved drawing
140
-
-
Erection of complete stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (2 Nos.) and 0.2 cmt concreting 1 part cement, 3 part sand, 6 part 40 mm size stone aggregate chips (1:3:6) as per technical specifications, approved drawings and scope of works.
3542
-
-
6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
518.85
-
-
6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
23.18
-
-
Painting with 2 coats of red oxide paint & 2 coats of alluminium paints on poles / equipment / metal surfaces on full rate basis.
6653
-
-
Jungle clearance thick and thin including cutting, uprooting and removing trees more than 20cm upto 61 cm girth, filling up and levelling the hollows of dugs roots, stacking the useful materials and disposing of rubbish upto a distance 15m outside the periphery of the area cleared (Girth to be measured 1.22m above ground level and at ground level in case of bamboo or cane clumps).
224.9
-
-
11/0.4 KV Distribution Transformer 16 KVA 3 phase Aluminium wound DTR
2
-
-
11/0.4 KV Distribution Transformer 25 KVA 3 phase Aluminium wound DTR
58
-
-
11/0.4 KV Distribution Transformer 63 KVA 3 phase Aluminium wound DTR
62
-
-
11/0.4 KV Distribution Transformer 100 KVA 3 phase Aluminium wound DTR
140
-
-
Danger Plate of size 250 mm x 200 mm of thickness 3 mm.(415V)
4707
-
-
AAC Conductor 120 Sqmm
152.96
-
-
Anti climbing devices with G. I. thornwire / Barbed wires.
247.5
-
-
AERIAL BUNCHED CABLE 3 X 120 SQ.MM. + 1x70 SQ. MM. +1x16 SQ. MM.
43.07
-
-
AERIAL BUNCHED CABLE 3 X 95 SQ.MM. + 1 x50 SQ. MM.+ 1x16 SQ. MM.
43.06
-
-
AERIAL BUNCHED CABLE 3 X 70 SQ.MM.+1 x50 SQ. MM.+ 1x16 SQ. MM.
193.95
-
-
Galvanized stay set complete with galvanised MS anchor plate of size 300 x 300 x 5 mm, anchor rod of length 1800 mm & dia 18 mm alongwith stay wire, thimble, bow, guy strain insulator, nuts & bolts etc. as required (of all sizes).
1256
-
-
Earthing with 40 mm dia GI pipe 4.5 mtr long with GI wire for pole earthing including salt charcoal etc. as reqd.
418
-
-