Department Of Education Tender
BidAssist is a very user-friendly website that helps us to explore all the new opportunities so as to achieve growth in our business. It helps us to attain all the information with respect to any e-tender the Arunachal Pradesh government has posted on its website in a very hassle-free manner.
Department Of Education Tender
Civil And Construction
Eprocure
Opening Date4 Oct 2024
Closing Date18 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 3,38,049Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_ARED_1948_1Bid Award Id
ViewTender No
EDN(EW)/Plg-015/2024-25/28Tender Authority
Department Of Education ViewPurchaser Address
-Website
http://arunachaltenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
39.98
-
-
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
69.41
-
-
Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering in : b) Walls including attached buttresses, pilasters and their caps and bases and string courses etc. up to floor two level.
49.14
-
-
Providing and laying damp proof course 38 mm thick with cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 12.5 mm nominal size).
29.98
-
-
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in :
a) 1 : 1.5 : 3 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
73.6
-
-
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to
47.58
-
-
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface.
148.14
-
-
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
480
-
-
Reinforced cement concrete work in stair cases (excluding landing) except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface, preparing of the top surface and finishing, nosing upto floor two level but excluding the cost of centring, shuttering and reinforcement with M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
15.09
-
-
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
959.28
-
-
b) Column Pillars Struts.
1058.56
-
-
c) Lintels, beams, girders, bressumers and cantilevers etc.
1983.59
-
-
d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas, slab
416.25
-
-
f) Stairs (excluding landings) except spiral stair cases.
52.95
-
-
Reinforcement of RCC work including bending, binding and placing in position complete. a) Mild steel.
36666.11
-
-
Brick work with best available local bricks in foundations and plinth in cement mortar 1:6 (1 cement : 6 fine sand).
37.98
-
-
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level
3452.59
-
-
Providing approved best available local wood (Class B-II) work in frames of doors, windows, clerestory window and other frames, wrought framed and fixed in position.
319.2
-
-
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws.
a) 38 mm thick best available local wood, class - B I
127.68
-
-
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and panelling to be paid for separately) : a) (I) Polyester powder coated aluminium (minimum thickness of polyester powder coating
50 micron)
965.75
-
-
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-incharge. (Cost of aluminium snap beading shall be paid in basic item) a) (I) With float glass panes of 8 mm thickness.
175.59
-
-
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal
245.6
-
-
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.
a) Ornamental Grill.
4716.6
-
-
Providing and fixing aluminum butt hinges anodised, transparent or dyed to required color or shade with necessary screws etc complete. a) 100 x 63 x 4 mm
588
-
-
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 100 mm
64
-
-
b) 75 mm
58
-
-
Providing and fixing M.S. hooks and Eyes
(a) 150 mm.
132
-
-
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
108
-
-
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts
and bolts complete, i/c fixing the railing with necessary accessories & stainless steel
dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members .
3173.8
-
-
Welding by gas plant
3173.8
-
-
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement. b) 50 mm thick
1920
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete a) Size of Tile 500x500 mm
162.87
-
-
White glazed tiles 5mm.thick in flooring, skirting, risers of step and dado in 12 mm thick cement plaster 1 : 3(1 cement: 3 coarse sand) painted with white cement slurry.
255.7
-
-
15 mm cement plaster 1 : 3 (1 cement : 3 fine sand). On the rought side of single or half brick
4210.53
-
-
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
4210.53
-
-
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
4210.53
-
-
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
4210.53
-
-
Distempering (two or more coats) with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
4210.53
-
-
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
164.58
-
-
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
164.58
-
-
Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 :6 (1 cement : 3 sand : 6 hard graded stone chips or aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete.
333
-
-
Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SW drain pipe 100 mmdia 1.80 m long complete as per standard design.
1
-
-
Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls (internal work). a) 15mm nominal bore.
11
-
-
b) 20mm nominal bore.
18
-
-
Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc (external work). a) 20 mm nominal bore
57
-
-
Providing and fixing brass bib cock of approved quality. a) 15mm nominal bore.
45
-
-
Providing and fixing brass stop cock of approved quality. a) 20 mm nominal bore
3
-
-
Providing and fixing PVC connection pipe with brass union 30cm length.
a) 15mm nominal bore.
12
-
-
b) 20mm nominal bore.
12
-
-
Painting G.I. pipes and fittings with white paint over a coat of ready mixed priming coat both of approved quality for new work.
a) 15 mm dia pipe
30
-
-
b) 20mm dia pipe
30
-
-
Providing and fixing white vitreous china water closet squating pan (Indian type WC pan) size 580 mm with 100 mm and sand cast iron P or S trap, 12.5 Litre high level CI flushing cistern (of approved make) with fittings RS or CI brackets, 32 mm dia galvan.
a) Long Pan patten WC Pan
16
-
-
Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleadt with CP brass screws and washers.
4
-
-
Providing and fixing white vitreous china wash basin with RS or CI brackets painted white 15 mm CP brass pillar taps and CP brass chain with rubber plug 32 mm CP brass waste of standard pattern, 32 mm dia CP brass trap and MI unions complete, including cutting and making good the walls where required. b) Flat back wash basin size 550x400 mm with single 15 mm CP brass pillar taps of heavy quality.
4
-
-
Providing and fixing rubber plug for sink or wash basin.
4
-
-
Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.
a) 50 mm dia
14.4
-
-
b) 100 mm dia
14
-
-
Providing and fixing sand cast iron heel rest sanitary bend.
a) 100 mm dia
4
-
-
b) 50 mm dia
5
-
-
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth
74
-
-
Septic Tank
Earth work in excavation in foundation and trenches etc. in all kinds of soil (excluding soil containing 50% or more of shingle or small size boulders upto 30 cm size, saturated soil and rock), lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers, when required, into plinth sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus soil as directed within a lead of 50m.
82.26
-
-
Providing and laying in foundations and plinth cement concrete 1 : 5 : 10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering.
6.58
-
-
Reinforced cement concrete in walls (any thickness) including attached pillasters, buttresses, plinth and string course, fillets etc from top of foundation up to floor two level including finishing and plastering the exposed surfaces with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface excluding cost of centring, shuttering and reinforcement in : a) 1 : 1.5 : 3 (1 cement : 1.5 corase sand : 3 stone aggregate 20 mm nominal size)
16.4
-
-
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centring and shuttering and reinforcement with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size).
4.94
-
-
Reinforcement of RCC work including bending, binding and placing in position complete.
a)Mild Steel.
1727.26
-
-
Centring and shuttering including strutting, propping etc. and removal of form work for:
a) Suspended floors, roofs, landing shelve and theirsupports, balconies and chajjas (3.50m height)
48.12
-
-
b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
101.64
-
-
12 mm thick cement plaster 1:3( 1 cement : 3 fine sand)
101.64
-
-
Neat cement punning
101.64
-
-
Cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement.
a) 40 mm thick.
32.9
-
-
Carriage of Materials
1
-
-
Electrification POINT WIRING Point wiring in PVC conduit, with modular type switch.
Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FR PVC insultated copper conductor single core cable in surface/recessed PVC conduit,with modular switch, modular switch, suitable size G.I. box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required. a) Group A
200
-
-
b) Group B
200
-
-
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
220
-
-
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
a) 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire (5A Plug).
480
-
-
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
300
-
-
25 mm
300
-
-
S/F modular type switch/socket :-
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
A) 5/6 Amps Switch
140
-
-
b)15/16 Amps Switch
100
-
-
c) 5/6 Amps Socket
60
-
-
d) 15/16 Amps socket outlet
82
-
-
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
120
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required
184
-
-
Supplying and fixing brass batten/ angle holder including connection etc. as required.
240
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
94
-
-
Installation, testing and commissioning of ceiling fan, includingwiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.5/6 amps switch
42
-
-
Installation, testing and commissioning of resistance type ceiling fan regulator,in existing switch box including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable,earthing the regulator etc. as required.
42
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. a) 510 mm sweep
3
-
-
CHAPTER 2 – MCCB, MCB & DB’S
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
a) 32 Amp TP&N
30
-
-
b) 63 Amp TP&N
25
-
-
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
a) 100 Amp
15
-
-
b) 125 Amp
15
-
-
Supplying and fixing of following ways surface/ recess
mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used
where 3 phase outlets are required.)
a) 4 way (4 + 12), Double door
8
-
-
Fittings
Supplying of 1200mm AC sweep ceiling Fan( Orient/Usha make)
108
-
-
Modular fan regulator ( anchor/Roma step make)
108
-
-
20 Wats LED Bulbs ( bajaj/ Phylips make)
150
-
-
15 Wats LED Bulbs ( bajaj/ Phylips make)
72
-
-
Fluorescent Tube set fitting/ ( bajaj/ Phylips make)
120
-
-
Fire Extinguisher
18
-
-
Furniture for Classroom Good Quality Bench & Desk.
53
-
-
Wooden table
6
-
-
Wooden Arm Chair
6
-
-
White Board
8
-
-
Furniture for Dormitory Wooden Bed
50
-
-
Wooden Writing Table
50
-
-
Wooden Arm Chair
50
-
-
Furniture for Diningn Hall Dining Table (5'x12")
4
-
-
Wooden Arm Bench (1'x12)
8
-
-
Land Development
Excavation in Hill Area in Soil by Mechanical Means (Excavation in soil in hilly area by mechanical means including cutting and trimming of side slopes and disposing of excavated earth with all lifts and lead upto 1000 metres)
4012.75
-
-
Excavation in Hilly Area in Ordinary Rock by Mechanical Means not Requiring Blasting. (Excavation in hilly area in ordinary rock not requiring ballasting by mechanical means including cutting and trimming of slopes and disposal of cut material with all lift and lead upto 1000 metres )
1719.75
-
-