Water Resources Department Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Water Resources Department - WRD Tender
Electrical and Electronics
Electrical Works
Opening Date24 Jan 2022
Closing Date22 Feb 2022
Tender Amount₹ 1,84,145
Costs
EMD
₹ 1,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
UKPRR/2021-22/BD/WORK_INDENT776Bid Award Id
ViewTender No
UKPRR/2021-22/BD/WORK_INDENT776Tender Authority
Water Resources Department ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying 6A flush type socket and 6 amps/ flush type SP switch either surface /flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. As per IS 1293 and IS 3654 6 amps 3/5 way with all lead and lifts etc complete & as per directions of Engineer in charge of work.
32
-
4224
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32 Amps D.P.Switch with all lead and lifts etc complete & as per directions of Engineer in charge of work.
2
-
364
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs scews 8"x6"x1.5" with all lead and lifts etc complete & as per directions of Engineer in charge of work.
5
-
350
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs scews 10"x8"x1.5" with all lead and lifts etc complete & as per directions of Engineer in charge of work.
4
-
360
Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs scews 12"x12"x2" with all lead and lifts etc complete & as per directions of Engineer in charge of work.
1
-
150
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 -do- 50-63 Amps SP with all lead and lifts etc complete & as per directions of Engineer in charge of work.
2
-
1446
Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxed, adhesive paste etc, and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxed and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary with all lead and lifts etc complete & as per directions of Engineer in charge of work.
225
-
11925
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694 confirming to latest amendments. -do- 2.5 sqmm with all lead and lifts etc complete & as per directions of Engineer in charge of work.
450
-
14400
Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. -do- 32 Amps with all lead and lifts etc complete & as per directions of Engineer in charge of work.
2
-
348
Supply and Installation/fixing/provision of outdoor type Thermoplastic modular panel enclosure with transparent polycarbonate Lid, shock proof, IP65 (Weather proof), rust proof, dust proof, water proof, corrosion proof having internally embedded gasket on both lid and flap suitable to fix single phase/Three phase energy meter in suitable base plate and having a provision for Fuse/MCB cutout with suitable transparent hinged flap opening for operating MCB alongwith complete tamper proof SEALING facility. -do- 300mm x 300mm x 214mm with all lead and lifts etc complete & as per directions of Engineer in charge of work.
1
-
3754
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS 374-1979 and with double ball bearing system.-do- 56" Sweep (1400mm) Regular model with all lead and lifts etc complete & as per directions of Engineer in charge of work.
14
-
29778
Fixing a ceiling/wall mounting fan of all capacities and all types, with necessary clamps and 'S" hook made out of 15mm dia MS rod, with 5 amps, ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality,mounted on a suitable size wooden board and wired.with all lead and lifts etc complete & as per directions of Engineer in charge of work.
14
-
3640
Fixing all types and all capacities of 1'x4'/2'x2' LED Light fittings indoor on the wall/ceiling/rasfters/girders with necessary supporting frame,using 23/0.0076" twin twisted PVC insulated wires,required Nos.of round blocks and clamps.with all lead and lifts etc complete & as per directions of Engineer in charge of work.
35
-
15750
Fixing halogen/metal halide/SVL/IL/LED floodlight fitting over existing pole/wall ceiling including clamps, bolts, nuts and wiring using suitable wires. with all lead and lifts etc complete & as per directions of Engineer in charge of work.
16
-
2800
Supplying,fixing,wiring earth electrode for grounding conduits, I.C.cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr. Long buried in a pit.. The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification. 7.3.3 of IS 732 using 12mm dia bolts, nuts washers and check nuts etc, the pipe shall have 16 through holes of 12mm dia. with all lead and lifts etc complete & as per directions of Engineer in charge of work.
1
-
2999.7
Supplying of 1.1 KV LT UG cable XLPE or heat resistant PVC insulated, PVC extruded inner sheath armoured UG LT cable as per IS-1554 (Part-1) r IS-7098 Part-1, Armouring strip thickness in average+ 5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 -do- 4 Core 10 sqmm with all lead and lifts etc complete & as per directions of Engineer in charge of work.
50
-
6500
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/stoneware pipe/on wall/on pole as required -do- 6sqmm to 16 sqmm with all lead and lifts etc complete & as per directions of Engineer in charge of work.
50
-
594
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc,complete (As per Civil SR KSRB 1tem No..2, Page-7) -do- In soil (ordinary) with all lead and lifts etc complete & as per directions of Engineer in charge of work.
40
-
3040
Supplying and fixing of class-A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV -do- 50mm with all lead and lifts etc complete & as per directions of Engineer in charge of work.
10
-
3800