Sri Venkateswara University Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Sri Venkateswara University Tender

Building Construction
Opening Date28 Jun 2021
Closing Date12 Jul 2021
Tender Amount₹ 1,09,21,374 
This is an estimated amount, exact amount may vary.
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;VRCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for columns.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

38

-

505240.4

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

3.75

-

51483

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;VRCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for T. L. Rectangular beams .

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

40.5

-

465814.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

4.25

-

50130.02

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;VRCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for lintels

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

9.75

-

128831.62

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;VRCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for slab 12.50 cms thick

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

55

-

604890

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

8

-

90072

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;VRCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for slab 10.00 cms thick

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

22

-

268562.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;VRCC M- 20 Nominal mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for slab 15.00 cms thick

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

2.8

-

28537.32

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

9

-

93718.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Cement concrete (1:1 1/2:3) mix using 12mm BSS gauge hard machine crushed granite metal from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete including , water profing compound @1.00 kg per bag of cement, cost of rabbit wire mesh & kept in position tying etc., for finished item of work, for weathering course , 75mm thick . 1.00/0.075 = 13.333 Sqm

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

40

-

276160

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Flooring with pressed clay flooring tiles, (west coast tiles) set over base coat of cement mortar (1:4) 20 mm thick over already laid RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with cement mixed with pigment of matching shade to full depth, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, confirming to APSS and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

560

-

673932

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Cement concrete (1:3:6) mix using 6mm to 12mm BSS gauge hard machine crushed granite metal from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for levelling course .

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

38

-

186238

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;RCC (1:4:8) using 20mm size machine crushed granite metal from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work, for dummy columns.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

10

-

127359

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply annd fixing of 110mm dia PVC rain water down take pipes of approved brand including bends, shoes fixed in position with clamps including cost and conveyance of all materials and operational charges, incidental charges and labour charges etc, complete for finished item of work and as directed during execution in all floors

35

-

19295.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Brick masonry 230 mm thick for panel walls in superstructure with CM (1:5) prop. ( cement : sand ) using second class bricks of size 23 X 11 X 7 cm from approved source having crushing strength not less than 35 Kg / Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including seigniorage charges, sales & other taxes on all materials and all operational, incidental and labour charges such as mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, etc., complete for finished item of work for external walls . (APSS No. 501 & 504).

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

78

-

558550.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

39

-

294789.3

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Reinforced Brick Masonary walls of 11.00cm in CM(1:4) using 2nd bricks having a crushing strength of not less than 35.00kg/cm2 and using two mild steel bars of 6m dia in every third layer of brick masory, with free joints of the main block work including cost and seignorage charges and conveyance of all materials and water from approved sources to work site and all operational, incidental, labour charges such as scaffolding mixing mortor constructing masonary lift charges, curing etc. complete but excluding the cost of steel and its fabrication charges for finished item of work as per SS 509 and as directed during execution. 1.00/0.11 = 9.09 Sqm (excluding cost of steel )

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

12

-

108706.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Plastering 12mm thick in two coats with base coat of 8mm thick in CM (1:4) and top coat of 4mm thick in CM (1:2) with smooth finishing including cost and conveyance of all materials like cement, sand, water etc., to site, cost of seigniorage charges and all other taxes on all materials, and operational, incidental charges and all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves etc. as directed by Engineer-in-charge, complete for finished item of work (APSS No. 901 & 904) for ceilings , beams , sunshades , RCC items etc.,

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

1225

-

655179

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

180

-

105413.4

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Plastering 12mm thick in two coats with base coat of 8mm thick in CM (1:5) and top coat of 4mm thick in CM (1:3) with smooth finishing including cost and conveyance of all materials like cement, sand, water etc., to site, cost of seigniorage charges and all other taxes on all materials, and operational, incidental charges and all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves etc. as directed by Engineer-in-charge, complete for finished item of work (APSS No. 901 & 904) for internal surfaces of brick walls and contigeous RCC surfaces.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

890

-

452342.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

110

-

60986.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Plastering 20mm thick in two coats with base coat of 16mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, cost of seigniorage charges and all other taxes on all materials, and operational, incidental charges and all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves etc. as directed by Engineer-in-charge, complete for finished item of work (APSS No. 901 & 904) for uneven faces of walls for external surfaces of brick walls

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

310

-

160676.1

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - III

475

-

268128

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Flooring with Non - Skid ceramic tiles, of size 300mm x 300mm and thickness between 7-8 of first quality of any colour and finish, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, .

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

130

-

128748.1

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Dadooing to walls with 1st quality white glazed tiles manufactured by ISO approved firm of any size set over 12mm thick CM (1:3) base coat and neat grey cement slurry of Honey like consistency at the rate of 3.3 Kgs per sqmt. and jointed with white cement paste mixed with pigment of matching shade to match the shade of tiles including cost & conveyance of all materials and water to work site, all operational, incidental, and labour charges such as mixing mortar, fixing in position, including lift charges, curing including cutting the brick masonry walls and redoing the same such that the top surface of tiles is to be flushed with plastered surface etc., complete for finished item of work (APSS NO. 701 & 707) and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

270

-

257841.9

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Flooring with Double charged / stain free soluble salt porcelain vitrified tiles with double layer pigment of size 600mm x 600mm and thickness between 8-10mm if any colour and finish in all shades and designs of 1st quality, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, .

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

420

-

544677

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Filling with carted river sand(excluding rock) in trenches, sides of foundations and basement with initial lead in layers not exceeding 15 cm thick, consolidating each deposited layer by watering and ramming including cost and conveyance of water to work site and all operational, incidental, labour charges, hire charges of T & P etc., complete for finished item of work. (APSS NO. 309 & 310)

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

15

-

14851.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 10 mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work and Providing and fixing 30mm thick BRAND FACTORY MADE BOTHSIDE PRELAM SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of MS. Tubes of 19gauge thickness and size of 19mmX19mm for stiles, top and bottom rails. MS. Frame shall have a coat of steel primers of approved make and manufacture. MS. Frame covered with 5mm thick heat moulded ?Rajshri? Prelam Pac ?C? channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 450 angle on either side forming stiles; and 5mm thick, 95mm wide Rajshri Prelam Pac sheet out of which 75mm shall be flat and 20mm shall be tapered in 450 on the inner side to form top and bottom rail 115mm wide Rajshri Prelam Pac sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. 10mm (5mmX2) thick, 20mmwide cross Pac sheet shall be provided as gap insert for top and bottom rail. Panelling of 5mm thick both side Prelam Pac sheet to be fitted in the MS. Frame welded/ sealed to the stiles & rails with 7mm(5mm+2mm) thick X 15mm wide Pac sheet beading on inner side, and joined together with solvent cement adhesive etc. an additional 5mm thick Pac strip of 20mm width is to be stuck on the interior side of the ?C? channel using Pac solvent cement adhesive etc. complete as per direction of Engineer ? in-charge, manufacture specification and drawing.(PVC Solid panel door with frame ) (0.91 x 2.14)

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

16.5

-

80081.1

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing N.P. Push Cock 12.7mm First Quality of approved make or equivalent etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

10

-

2659

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing Angle stop cock 12.7mm (1/2?) Indian Make of approved manufacture and standard make (heavy type) or equivalent etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

10

-

4758

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing C.P. short body Bib cock 12.7mm Indian Make of approved manufacture and standard make (heavy type) or equivalent etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

6

-

3579

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing C.P long body bib cock 12.7mm Indian Make of approved manufacture and standard make (heavy type) or equivalent etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

20

-

12430

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of 12.7mm dia PVC connection with brass union nut , cp coated,inlcuding cost and conveyance of all necessary materials , labour chaerges etc., complete for finished item of work and as directed by engineer - in - charge during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

20

-

2052

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing of 38.1m dia PVC solid waste pipe out let inlcuding cost and conveyance of all necessary materials , labour chaerges etc., complete for finished item of work and as directed by engineer - in - charge during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

13

-

1137.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply, Laying, Jointing and Testing the PVC/SWR Pipe line 6Kgs/Sqcm of approved quality and make with single socket end including cost and conveyance of required materials GI clamps, necessary jointing materials, labour charges for fixing but excluding cost of specials etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

18

-

6568.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

18

-

4285.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing of PVC/SWR specials of approved quality and make including cost and conveyance of all materials etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;75mm dia

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Plain Bend

15

-

717

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Single ?T?

15

-

853.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Coupling

10

-

341

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Single 'Y'

15

-

1074

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Nahany trap with jalli

20

-

1956

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Cowl

3

-

41.1

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Door Bend

4

-

259.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;110mm dia

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Plain bend

8

-

636.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Single 'T'

6

-

620.4

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Coupling

10

-

546

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;single 'Y'

7

-

914.9

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;cowl

3

-

54.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Door bend

4

-

413.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing of Premium make CPVC Pipes and Fittings to meet the requirement of ASTM-D 2846 and are produced in CTS (Copper Tube Sizes 1/2" to 2" Ashirvad Flowgurard SDR 11 pipes are made from idential CPVC compounds having the same physical Properties for Hot and Cold Water (IS 15778:2007), including all incidental, labour charges involved, complete for finished item of work and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;28.60mm OD Pipe

38

-

6220.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;22.20mm OD Pipe

25

-

2642.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying & Fixing white glazed flat back half stalled urinals Ist quality conforming to IS:2556-1995 with standard C.P. spreader of overall size 95x95x57mm conforming to IS:2556-part6, Sec-6-1974 fixed with screws complete Indian make (HSW/Parry/Neycer): 410x265x305mm

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

6

-

16474.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing Indian make Flat Back wash hand basin of approved make and first quality conforming to IS:2556-part-4:1972 with waste fittings like rubber plug, chain, 32mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15mm nominal bore chromium plated pillar tap of first quality Indian make 400grams Seiko/Senior/Nice/ Esso or equivalent complete with standard CI brackets including wooden block:660x460mm ? Single C.P. Pillar cock.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

4

-

11065.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing of White glazed European Water Closet of First Quality conforming to IS:2556-part-2-1973 and approved make white glazed with ?S? trap etc., with plastic seat

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

2

-

5803.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing PVC low level system parry ware slim line with internal components and short bends 10lit capacity single flush

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

2

-

2849.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing TV shape mirror with plastic frame size 609.6mmx457.2mm including cost and conveyance of all materials, labour charges for fixing etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

4

-

2186

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing 20.00mm dia and 609.6mm long CP towel rod with brackets and aluminum screws.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

4

-

1600

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing N.P Soap dish heavy type with NP Screws including cost and conveyance of all materials, labour charges for fixing etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

4

-

959.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and Fixing of Nominal Bore GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;50mm dia

18

-

9765

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;40mm dia

25

-

12262.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing & Placing on Terrace (at all floor levels) polyethylene Vinyl chorile water storage tank with Double layer of approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks complete for finished item of work and as directed during execution. Conforming to IS - 12701 - 1996

5000

-

30000

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars (Fe 415/ Fe 500 grade as per IS 1786-1979) below 36mm dia for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work ( APSS No.126) and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

18

-

1203501.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Drilling holes in CC/ Brick masonry and fixing steel reinforcement using lock fix materials including cost and conveyance of all materials as directed during exection.

25

-

2557.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providng welding to the steel rainforcement of different dia meters to the existing steel rainforcement of slab or beam including cost welding roads, conveyance and rental charges of welding machine labour charges etc., complete as directed during execution.

110

-

2750

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing in position M.S. ornamental grills for windows and ventilators or for verandah openings using M.S.flates, square rods, anglesheets, etc of approved design including necessary holes cuttings, bending , fabrication welding grinding and finishing smooth , incuding cost of making holes in to RCC masonry works and making good the same whereever necessary, including cost and conveyance of all materials, incidental charges etc complete.

2250

-

210375

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;RCC (1:1 1/2:3) mix slab 50mm thick using 6mm to 12mm BSS gauge hard machine crushed granite chips for pre - cast panel parapat 5.00 Cm thick providing pebble desh plastering 28mm thick in cement mortor 1:5 16mm thick for first coat and 12mm thick in cement mortor 1:3 by ading 6 to 12mm chips for second coat to parapat and providing cement mortor 1:4 20mm 100cm vide plastering band and both sides all round thick panel slab etc., including cost and conveyance of all materials from approved sources to site of work, labour charges, water curing fixing the panel parapat in bitween columns with necessary suport complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

31

-

32842.95

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Painting to new walls with 2 coats of ready mixed oil bound washable distemper of approved brand and shade over a base coat of appropriate primer of approved brand, making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for internal walls.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II & Level - III

2405

-

328450.85

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Painting to New walls with 2 coats of exterior emulsion paint using Acrylic emulsion exterior grade paint with weather proof water - based modified acrylic with silicon additions exterior grade having VOC content less than 50 grames / litre of approved brand and shade over one coat of exterior grade cement primer ( total 3 coats ) after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for external walls.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II & Level - III

1650

-

406989

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Throughly Scraping old exterior walls with 2 coats of exterior emulsion paint using Acrylic emulsion exterior grade paint with weather proof water - based modified acrylic with silicon additions exterior grade having VOC content less than 50 grames / litre of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for external walls.

820

-

141335.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing painting for new teak wood joinery two coats over one coat of wood primer usijng first class synthetic enamel paint of approved manufacture and desired shade, including cost and conveyance of all materials , brushes, sand papers, labour charges, incidental charges etc., complete for finished item of work confirming to APSS and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

75

-

14273.25

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing in position of 50mm thick RCC Jallie made of RCC (1:2:4) as per approved designs & drawings supplied by the deparment including cost and conveyance of all materials, labour charges, incidental charges complete for finished item of work and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

13

-

9077.9

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing of granite urinal baffle wall of size 0.76x1.22mts (2-6" x4'-0") using both sides high polished block granite slab of 16-18mm thick, full rounding the outer 3 edges, cutting to the required shape as per drawings supplied, inlcuding labour chaerges , incidental charges , hire & operational charges of tools & plants etc., complete for finished item of work and as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Level - II

8

-

33876

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing in position teak wood framed and planked door of size 1.37 x 2.60 mts using teak - wood frame of section 100 x 75mm, styles and rails of section 100 x 40mm except lock rail of section 150 x 40mm and bottom rail of section 225 x 40mm and 12mm thick cement bonded board for panels inserted in between styles and rails including cost of necessary fittings such as 6 Nos of MS 'Z' hold fasts, 8 Nos of P.C. but hinges 125mm size, 3 Nos of aluminium tower bolsts 200mm size, 1 No of aluminium latch 250mm size 1 No of aluminium aldrop 250mm size, 1 No of aluminium handle of 150mm size, 2 Nos MS flat wind appliance (all aluminium fittings should of approved brand and variety) including cost and conveyance of all materials from approved sources to site of work,cost of screws, nails, fevicol etc., labour charges, incidental charge, Operational charges, T & P hire charges etc., complete for finished item of work confirming to APSS and as directed during execution.

25

-

211875

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing and fixing in position anodized / powder coated aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85 x 31.75mm, with 1.2mm thick, bottom section weight 0.695 x 31.77 kg/m, sides and top sections 1.3mm, thick weight 0.659 kg/m, and shutter comprising top and bottom section of size 40mm x 18mm, 1.25mm thick 0.417 kg/m, shutter outer side 40mm x 18mm, 1.25mm thick weight 0.417 kg/m, shutter interlock section 40mm x 26.7mm, 1.1mm thick, weight 0.469 kg/m. The shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles, tower bolts etc., and providing and fixing 5.0mm thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdviding the frame tennoned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/ cills as the case may be with necessary steel screws, rawl plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortor, aluminium sections pretreated for removal of any rust and protection of further rust formation and coated with the greasy materials for non - adhesion of mortor and any other sticky materials, (this coating should be cleaned after installation) including cost of materials, fixtures, labour and HOM of machinery complete as per specification.

12

-

48417.6

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing and fixing in position anodized / powder coated aluminium windows and vetilators as per approved drawings with sliding shutters using three track window frame section of size 92 x 31.75mm with 1.2mm thick, bottom section 1.3mm thick weight 1.07kg/m, sides and top sections 1.3mm thick weight 0.933kg/m, and shutter comprising top and bottom section of size 40 x 18mm, 1.25mm thick 0.417kg/m, shutter out side 40mm x 18mm, 1.25mm thick weight 0.417kg/m, shutter inter lock section 40 x 26.7mm, 1.1mm thick, weight 0.469kg/m. The shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles, tower bolts etc., and providing and fixing 5.5mm thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tennoned and rivetted in the assenbled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with mecessary steel screws, rawl plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortor, aluminium sectins pretreated for removl of any rust and protection of further rust formation and coated with the greasy materials for Non - adhesion of mortor and any other sticky materials, (this coating should be cleaned after installation) including cost of materials, fixtures,laobur and HOM of machinery complete as per specifications.

65

-

259879.75

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Construction of Brick masonry inspection chamber of size 0.76mX0.76m internal dimension using country bricks(non-modular) in CM (1:4) and plastering in CM(1:3) 20mm thick inside as well out side of the exposed portion including earth work excavation in all types of soils except rock requiring blasting and filling the vanka sand 100mm thick below the bed concrete and laying P.C.C (1:5:10) 150mm thick using 40mm HBG metal and P.C.C(1:1 1/2:3) benching and channeling with an average thickness of 100mm as per standard specification and also finally Providing pre-cast RCC(1:1 1/2:3) cover slabs with 50mm thick using 3mm to 10mm HBG chips using necessary reinforcement including 2 No?s, 8mm dia handles at the top and plastering in CM(1:3) 12mm thick on one side including cost and conveyance of all materials like cement, sand, bricks, steel and its fabrication charges, centering charges etc., complete as directed during execution.(1.20m depth foundation finished level to top level.

2

-

28951

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Fixing of Gunmetal Gate (GM peet) valve as per IS-778 class-I, Indian make heavy type including cost and conveyance of all materials etc., Complete as directed during execution.

-

-

-

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;25mm dia GM Valve

2

-

2413.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;40mm dia GM Valve

1

-

2467.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;50mm dia G.M. Gate Valve

1

-

3610.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing in position white glazed squatting urinal of standerd size, 1st quality confirming to IS: 256-1995 including cost and conveyance of all materials, labour charges, incidental charges etc., complete for finished item of work and as directed during execution.

3

-

7153.11

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing and fixing in position anodized / powder coate aluminium ventilators as per approved drawings with fixed ventilator of size 62.5 x 37.5mm with 1.2mm thick bottom section weight 0.85 kgs/m. The shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles, tower bolts etc., and providing and fixing 5mm thick plain glass for shutters fitted with rubber beading aluminium sectons including cutting to required length, joints mitred subdividing the frame tennoned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels floor beams/cills as the case may be with necessary steel screws, rawl plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortor, aluminium sectons pretreated for removal of any rust and protection of further rust formation and coated with the greasy materials for Non - adhesion of mortor and any other sticky materials, (this coating should be cleaned after installation) including cost of materials, fixtures,labour and HOM of machinery complete as per specificatons.

30

-

109987.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supplying and fixing spreader at urinals including cost and conveyance of all materials labour charges as directed during execution.

7

-

3022.25

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and laying of ISI 25mm outer dia medium (1.80mm thickness) grade with IS:9537 part 3 regid PVC pipe consealed in wall with PVC junction boxes and all required accessories including masonary work for light, fan and separate plug point with supply and fixing of suitable size well seasoned wooden deep box box including all labour charges etc., complete.(Data No. 2020-21-4.1.2)

450

-

38385

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Wiring with run of 2 of 14/0.3mm (1.0 Sqmm) FRLS / HFFR PVC insulated flexible ISI mark copper cable in existing PVC conduit pipe including Supply and fixing of Jumbo Ceiling rose and 6A/10A ISI Mark 1way Modular switch with required modular box and cover frame in existing Surface or Concealed pipe wiring including cost and conveyance of all material and all labour charges etc., complete for light and bell points in N.R.B.(Data No.2020-21-11.1.1)

58

-

36511

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Wiring with run of 3 of 14/0.3mm (1.0 Sqmm) FRLS / HFFR PVC insulated flexible ISI mark copper cable in existing PVC conduit pipe including Supply and fixing of Jumbo Ceiling rose and 6A/10A ISI Mark 1way Modular switch with required modular box and cover frame in existing Surface or Concealed pipe wiring including cost and conveyance of all material and all labour charges etc., complete for fan and exhaust fan points in R.B. (Data No.2020-21-11.1.2)

52

-

41813.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of 6A/10A ISI Mark 3/2 pin Modular socket with 6A/10A 1way Modular switch, 3 Module box with cover frame on a Common switch board including cost and conveyance of all materials and all labour charges etc., complete in N.R.B. / R.B. (Data No.2020-21-12.1.1)

13

-

5196.1

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of 3 Nos 6A ISI mark Modular type switch with 3Nos 6A 3/2 pin wall plug socket on suitable size Modular deep box with cover frame including cost and coveyance of all material and all labour charges etc., complete for Computers in N.R.B. / R.B. (Data No. 2020-21-12.1.5)

19

-

20947.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of ISI mark 16A 3pin / 6A 3 Pin 1 way Modular combi socket, 16 Amps Modular switch, 3 Modular box with suitable cover frame and earth connections including cost and conveyance of all material and all labour charges etc., complete in N.R.B. / R.B. (Data No.2020-21-12.1.4)

2

-

1152.5

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Run of 2 of 36/0.3mm (2.50 Sq.mm) with Run 1 of 22/0.3mm (1.5Sqmm) FRLS / HFFR PVC insulated flexible ISI mark copper cable in existing pipe for run of mains inlcuding all labour charges etc., complete.(Data No.2020-21-13.1.10 )

320

-

29120

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Run of 2 of 56/0.3mm (4.00 Sq.mm) with Run 1 of 36/0.3mm (2.5Sqmm) FRLS / HFFR PVC insulated flexible ISI mark copper cable in existing pipe for run of mains inlcuding all labour charges etc., complete.(Data No.2020-21-13.1.11 )

230

-

30153

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Run of 4 of 56/0.3mm (4.0 Sq.mm) with Run 1 of 36/0.3mm(2.5 Sqmm) FRLS / HFFR PVC insulated flexible ISI mark copper cable in existing pipe for run of mains inlcuding all labour charges etc., complete.(Data No.2020-21-13.1.13)

25

-

5785

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Run of 4 of 126/0.4mm (16.0 Sq.mm) with Run 1 of 84/0.3mm(6.0 Sqmm) FRLS / HFFR PVC insulated flexible ISI mark copper cable in existing pipe for run of mains inlcuding all labour charges etc., complete.(Data No.2020-21-13.1.16 )

45

-

30825

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of 8 Way TPN DB Horizontal with IP 43 Protection as per IS:13032 and suitable for 24 Nos S.P. out goings and for 1 No 4 pole Incommer with 1 No100A FP Isolator and 24 Nos 6-32 A 10kA SP MCBs of including internal connections and labour charges for SURFACE / FLUSH Mounting etc., complete. (Data No.2020-21- 17.1.2)

1

-

13543.3

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply, Transportation and fixing of 1x36/40W box type tube light luminaire with powder coated CRCA sheet steel housing with VPIT / Electronic Ballast and 1No 4'-40W tube Including fixing on wall / ceiling on TW round blocks and all standrad accessories.(Data No.2020-21- 21.1.1)

58

-

53760.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply, Transportation and Fixing of 48" (1200mm) Sweep ISI mark Ceiling Fan as per IS 374 - 1979 / as per IS 374 - 1979 and 5 Star rated Ceiling Fan / 5 Star rated Ceiling Fan with double ball bearings but without regulator including all standard accessories and all labour charges etc., complete.(Data No.2020-21- 23.1.1)

24

-

52240.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Providing independent earthing by exacavating a pit to a depth of 2.25Mtr in all soils as per size specified in the data for Important equipment with 2.5Mtr length 40mm dia 'B' class G.I pipe and 18" dia 3" thick hume pipe ring with R.C.C. Slab cover duly providing staggered holes filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder from the bottom of the pipe giving earth connection from electrode through G.I strip of 25 x 6mm x 200mm length to be bolted with nut bolts including supply and termination of No.8 G.I.wire from bottm of the pipe with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)(Data No.2020-21- 25.1.2)

2

-

8429.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply of 100A 415V TPN Double Break Switch in SS enclose without Fuses Makes:-HPL/Havells /Standard/Indo Asian (ELEC.2.5.2(a))

1

-

5700

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply, Transportation and Fixing of light duty 12" (300mm) ISI, Fresh Air fan / 9" (225mm) ISI, Fresh Air fan with metallic body and blades including making hole in wall and masonary work and all labour charges etc., complete. (Data No.2020-21- 23.1.11)

2

-

4140.2

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of DB with 1 No 20A single phase plug and Socket, in sheet steel enclosure with 1 No 10A to 20A 10 KA SP MCB including internal connection and labour charges for flush Mounting etc., complete. (Data No.2020-21- 19.1.1)

14

-

25020.8

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply of 120sqmm 3.5 Core XLPE insulated 1100V Grade Armoured Alluminium cable as per specification conforming to IS:7098 (Part - 1) of Makes:- Polycab/KEI/RPG/Finolex/Havels/Parogon/ V-Guard/Fortune Art/Gloser/Suncab (Data.2020-21-4.1.2 ) L

65

-

37375

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and fixing of Crimping Type Alluminium Lugs conforming to IS. Specifications for cable of 120Sqmm including Nuts and Bolts with connections etc., (ELEC.2020-21.21.4.1.13) g.

6

-

240

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Earth work Excavation of Trench in hard ground soil and sand filling shall be provided at the bottom of trench before laying the cable and laying of U.G cables from 70 Sqmm up to 400 Sqmm covering the cable with bricks and back filling of Trench duly providing route indicator at every 8 Mters distance embedded in C.C. including cost and conveyance of materials and labour charges etc., complete (Data No.2020-21-21.24.1.2)

40

-

10732

... More
Construction of Examination Hall over the existing Ground Floor at North West Corner of P.S.Block in;Supply and Transportatin of 60w L.E.D Street light luminair made of pressure diecast alluminium with powder coated, having protective toughned glass, supply input voltage 120-270V AC,P.F>0.90 high power LED's system efficacy > 100 im/W and junction temperature < 70*C with ingrees protection IP66 Luminaire performance complies to IS 10322 (Part 5 / Sec-3) Driver surge protection 4KV in house additional surge protection > 10KV with optics distribution THD <10% at 110 volts AC, driver efficacy > 90% CCT:3000K - 5700K minimum CRI>70,ETC., complete. MAKES:- a) Luminair Make: Wipro / Philips (Green line Extra)/ Lighting Technology,(Adomis)/ SCHREDER (Voltana Teceo)/ GE / Vin / Crompton(Hawk-II)/Wipro /Bajaj(Edge+)/Havels (Endura)/VIN(Metrix) b)Led Make: Philips Lumileds / CREE / NICHA/Osaram/ Samsung/ L.G (Data No.2020-21Elec.3.8.23) d

4

-

23600



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.