Sri Padmavati Mahila Visvavidyalayam Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Sri Padmavati Mahila Visvavidyalayam - SPMVV Tender

Works
Electrical and Electronics
Electrical Works
Opening Date29 Jul 2024
Closing Date12 Aug 2024
Tender Amount₹ 6,74,428 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Testing of Transformer oil for dielectric breakdown strength

5

3819

763.73

... More
Replacing old and unserviceable gasket of top cover plate of transformer having following capacity of up to 315 KVA

5

4772

954.39

... More
Replacing L.T bushing Upto 315 KVA . for distribution Transformer by new one.

30

7648

254.93

... More
Supply of 40A 2 Pole 30mA RCCB for earth leakage protection.Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti pro/HPL(Techno)

15

51560

3437.32

... More
Supply of 40A 2 Pole 100mA RCCB for earth leakage protection.Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti pro/HPL(Techno)

15

54645

3642.98

... More
Supply of 40A 4 Pole 30mA RCCB for earth leakage protection. Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti pro/HPL(Techno)

5

18922

3784.37

... More
Supply of 40A 4 Pole 100mA RCCB for earth leakage protection. Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti pro/HPL(Techno)

5

19629

3925.76

... More
Supply of 63A 4 Pole 30mA RCCB for earth leakage protection. Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti pro/HPL(Techno)

5

21884

4376.72

... More
Supply of 63A 4 Pole 100mA RCCB for earth leakage protection.Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti pro/HPL(Techno)

5

24331

4866.23

... More
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure

4

12961

3240.23

... More
Supply and fixing of PVC synthetic elastomer electrically insulated at conforming to IS: 15652-2006 with Class A insulation having 2mm thickness upto 3.3KV.

10

49252

4925.15

... More
Supply Installation Testing and commissioning of Heavy duty Three phase 440 V , 50 Hz capacitor (Bank)self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. Makes: L&T/Seimens/Epcos/Schneider/Havells

100

38133

381.33

... More
Supply of 6A to 35 A HRC Fuse Links as per IS 13703-Part 2/IEC 60269-Part 2Makes: L & T / G E / C & S / Standard / HPL / Havells / Siemens / Indo Asian

15

1012

67.48

... More
Supply of 45A to 63A HRC Fuse Links as per IS 13703-Part 2/IEC 60269-Part 2Makes: L & T / G E / C & S / Standard / HPL / Havells / Siemens / Indo Asian

15

1542

102.83

... More
Supply of 100 A to 160 A HRC Fuse Links as per IS 13703-Part 2/IEC 60269-Part 2Makes: L & T / G E / C & S / Standard / HPL / Havells / Siemens / Indo Asian

15

4804

320.27

... More
Supply of 250A to 350A HRC Fuse Links as per IS 13703-Part 2/IEC 60269-Part 2Makes: L & T / G E / C & S / Standard / HPL / Havells / Siemens / Indo Asian

15

7134

475.59

... More
Supply of 400A HRC Fuse Links as per IS 13703-Part 2/IEC 60269-Part 2Makes: L & T / G E / C & S / Standard / HPL / Havells / Siemens / Indo Asian

15

13577

905.12

... More
Providing independent earthling by excavating a pit to a depth of 2.25Mt in all soils, as per size specified in the Data, using 40mm dia 'B' class GI pipe of 2.5 Mtrs length with necessary No.8 G.I. double earth wire and accessories with 18" dia 2" thick hume pipe ring duly providing staggered holes including filling with 20Kg Salt and 40Kg Charcoal or 40Kg bentonite powder in layers and all labour charges etc., complete.

10

41949

4194.94

... More
Supply and laying of following sizes 8 SWG Copper wire(0.1155Kgs/1Mtr) Earth wire/Strip in horizontal /Vertical run inGround/surface/Recessincluding,revitting,soldering,saddles,making connection etc as required

120

11826

98.55

... More
Carryout routine maintenance and servicing of LT.Cubical pannel board having approximately 15 to 22 Nos of switches cleaning with power blower and servicing the contacts, tightning the connection of incoming and outgoing cables, and checking the operating machanism for smooth functioning of switches and putting them in smooth working condition.

4

15270

3817.58

... More
Loading, transportation and Unloading of transformer from site to Workshop or vice verse Upto 500 KVA

1

5726

5726.37

... More
Supply and transportation of 60W LED Street light Luminaire made of pressure diecast alluminium body with powder coated, having protective toughned glass, Supply Input voltage 120 - 270 V AC, P.F 0.90, high power LED's having System efficacy 100 lm/W and junction temprature 70°C, with Ingrees protection IP66, Luminaire performance complies to IS 10322 (Part 5 / Sec-3), Driver surge protection 4KV, In house additional Surge protection 10 KV with optics distribution , THD10% at 110 Volts AC, driver efficiency 90%, CCT: 3000K - 5700K, minimum CRI70, etc., complete. Makes : a) LUMINAIRE MAKE : Wipro(Skyline) / Philips (Green line) / GE-Venture / Crompton(Neo Series) / Bajaj (Edge) /Halonix(Lumos - Super) / Havells (Endura Series) /Capart(Premium)/Greenlites(Hi-Lux) /Polycab/Keselec/ HPL(City Vision)/ Jaquar(Premium)/Eveready/ Surya (Pollux) / FortuneArrt (Leaf) / Rhino(GPSL04) b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG

6

32443

5407.17

... More
Supply and fixing of Three Phase Electronic energy Meter AC,50 HZ as per IS13010 up to 40A range with 200% over load capacity complete with connections etc., complete on the existing board. Makes: CONZERVE / ELMEASURE / MECO / HPL /

5

16496

3299.14

... More
Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 2000 / 5 to 3200 /5 Ratio, 15 VA, class 1 accuracy Make: Kappa/L&T/Seimens/C&S/Schneider

15

26511

1767.4

... More
Supply of 63A ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: L&T / Schneider / C&S / ABB / SIEMENS.

5

14112

2822.48

... More
Supply of 250A ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: L&T / Schneider / C&S / ABB / SIEMENS.

2

21104

10551.9

... More
Supply of 400A ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: L&T / Schneider / C&S / ABB / SIEMENS.

2

32546

16272.91

... More
supply of G.I Nuts, Bolts and Washers each set.

50

750

15

... More
Aggregates 13.2/12.5 mm nominal size (SS5)(M-052)

16.58

28730

1732.8

... More
Stone crusher dust finer than 3 mm with not more than 10% passing 0.075 sieve (M-021)

16.58

12799

771.98



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.