South Central Railway Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

South Central Railway - SCR Tender

Works
Civil And Construction
Excavation
Ireps
Opening Date15 Oct 2024
Closing Date7 Nov 2024
Tender Amount₹ 40,18,18,035.75 
Notes
Download

Costs

Summary

Doubling Of Track Between Guntur - Bibinagar Section - (i) Execution Of Earth Work (ii) Extension Of Minor Bridges & Rubs (iii)construction Of Platforms, Service Buildings, Foot Over Bridge, Cover Over Platforms (v) Construction Of Mse Walls (iv) Collection Of Ballast & Dumping (v) Supply Of P.way Materials , Transportation Of P.way Materials, Laying & Linking Of Track , Assembling & Insertion Of Points & Crossings And Other Miscellaneous Works Including Electrification & Signaling Works From Km.4.665 To Km 10.00 Between Pagidipalli (including) And Bommaipalli (including) Stations.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
WOOD AND P.V.C. WORK // MISCELLANEOUS-WOOD WORK // Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. // Fixed to openings /wooden frames with rawl plugs screws etc.

-

-

29

... More
FINISHING // CEMENT PLASTER (IN FINE SAND) // 12 mm cement plaster of mix : // 1:6 (1 cement: 6 fine sand)

552

282

124531.2

... More
DISMANTLING AND DEMOLISHING // Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. // In cement mortar

-

-

62

... More
SANITARY INSTALLATIONS // Providing and fixing toilet paper holder : // Vitreous china

3

463

1111.2

... More
STEEL WORK // Providing and fixing bolts including nuts and washers complete.

1038.1

140

116391.77

... More
Transportation of precast PSC slabs from the casting point

92.55

2278

210828.9

... More
Loading, leading and unloading of all types of P.Way fittings and all other miscellaneous material except Rails, sleepers, switches, crossings, SEJs and Glued Joints by road vehicles for different leads. Note: Lead shall be the shortest motorable road length between the points of loading and unloading. Lead up to 5 Km

-

-

9

... More
Under Traffic Block: Dismantling of existing BG turnouts, diamond crossings and derailing switches with all types of rails and sleeper layout, removing rails, switches, crossings, sleepers & fastenings, leveling of ballast to correct profile & stacking all the released materials, sleepers, fastenings, rails, switches & crossings including segregating & stacking at specified locations in a neat and countable manner, within the lead of 250m & all lift, clear of infringements, crossing of track, if any complete, as directed. Note: 1. This item shall be operated only when existing turnout is replaced either with new turnout in case of TTR or with plain track when existing turnout is no more required at that location. 2. Rail cutting will be paid extra under relevant item. 3. Laying of new turnout or plain track on prepared ballast bed, as required, shall be paid separately under relevant item. 1 in 81⁄2 Turnout (Under Traffic Block)

-

-

39

... More
Manufacturing, fabricating and supplying retro-reflective Engineering Indicator boards, made of 2mm thick aluminium sheet or 3mm thick aluminium composite sheet, face to be fully covered with high intensity encapsulated type heat activated retro-reflective sheeting conforming to type-IV of ASTM-D4956-01 in yellow & black or other colour combination including subject matter, message, symbols, borders etc. as approved by Engineer In-charge or as per IRPWM guidelines, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class-2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back-support frame of M.S. angle iron of size 25mm x25mm x 3mmprovided all along the edges of board with theft resistant measures back side of board shall be with non-peelable weatherproof paint, consisting of one coat of zinc chromate primer and two coats of epoxy paint. Vertical post shall have black & white anti-corrosive paint or powder coating complete, as directed. Caution Indicator Board of size 1400mmx400mm with back support frame fixed to vertical post of MS angle of size 50mmx50mmx6mm of 3650 mm long

-

-

50

... More
Erection or removal of temporary Engineering Indicator Board or any other board at specified locations without causing infringement to track etc. complete and as directed. For erection

-

-

91

... More
Supply and using Cement at Worksite Ordinary Portland Cement 53 grade of approved brands/makes

1364.63

7258

9904907.58

... More
Supply of Water tankers daily twice (once in day & Night time) for 30 days during Pre Pre NI, Pre NI & NI Period.

300

540

162000

... More
(SOR NO 102)Supply of CLS Ladder set complete with staging/platform, supports, cast iron ladder base/Shoe. (Inspection by RITES) 3

-

-

103314

... More
(SOR NO. 110) Supply of Junction type / Direction type route indicator as per specification IRS:S 66-84 Amd. 1 or latest. (Inspection by RITES)

-

-

71354

... More
Supply of B type chokes to as per specification IRS: S65- 83 Amd.1 or latest. (Inspection by RDSO)

80

2313

185040

... More
(SOR NO 406 (a) )Supply of Stationary low maintenance secondary lead acid cells as per RDSO specification IRS: S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, acid level indicating floats and vent plugs. 2V, 80AH (Inspection by RDSO) 19

-

-

18

... More
Supply of Hydrometer as per IS: 3104 (Part II)-1982 or latest (Inspection by Consignee)

5

277

1385

... More
Supply of Porcelain insulators for secondary lead acid cells. (Inspection by Consignee)

500

30

15000

... More
(SOR No. 501) Relays-Metal to Carbon Supply of Plug-in type miniature tractive armature Non-AC immune, DC neutral line relay complete with plug board, retaining clip/ATC Clip and connectors as per specifications BRS 930, IRS:S 23-88 Amd. 1 or latest, IRS: S 34-68 Amd.6 or latest, IRS: S 67-85 Amd. 3 or latest (as applicable). (Inspection by RDSO)

-

-

917740

... More
(SOR NO.502) Supply of 24 V DC plug-in type miniature tractive armature, AC immune relay complete with plug board, retaining clip/ATC Clip and connectors as per IRS: S 23-88 Amd. 1 or latest, IRS: S 34-68 Amd. 6 or latest, IRS: S 60-78 Amd. 1or latest, IRS: S 67-85 Amd. 3 or latest (as applicable).(Inspection by RDSO)

-

-

1358010

... More
SOR NO.601)Supply of powder coated Relay rack universal type as per DRG. No. S&T/MFT/291. The relay rack 28 shall be supplied with scaffolding, stainless steel nuts and bolts for fixing the rack, supporting angles, frame mounting triangle base with 'J' bolts, insulation of required numbers and suitable inner frames to suit Q style relays / K50 pre wired tag blocks.(Inspection by Consignee)

-

-

100066

... More
(SOR NO. 605)Supply of non-deteriorating type of fuse holders and fuse links 240V AC/DC as per specification IRS: S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type fuse of E1 fuse link type (up to 20A)

-

-

123500

... More
(SOR NO 1002) Supply of Various Telephones and Telephone Power Supply unit 46

-

-

85288

... More
(SOR NO 1006)Supply of VF Transformer and accessories 49

-

-

47250

... More
(SOR NO 1009) Supply of OFC Related items 52

-

-

3711709

... More
(SOR NO 1010) Supply of IP Based CCTV Camera (Inspection by Consignee) 53

-

-

345860

... More
(SOR NO 1404) Supply of Spare Cards for High Availability Single Section Digital Axle Counter (HASSDAC) as per specification RDSO/SPN/177/2012 Ver. 3.0 or latest. The spare cards shall be supplied as per the make of SSDAC and to the version as specified by the engineer in-charge.(Inspection by RDSO)

-

-

414777

... More
Supply of 50mm x 6mm GI tape for interconnecting earth electrodes. (Inspection by Consignee)

500

546

273000

... More
(SOR NO 1705)Supply of Lugs and Eyelets: (Inspection by Consignee) 68

-

-

22200

... More
Supply of Corium Z 105 Battery cleaner and terminal conditioner of 500ml tin can. (inpection by Consignee)

5

5274

26370

... More
(SOR NO 1717) Supply of transparent plastic cover of superior quality of Various Size. The sheet shall have provision for hanging.

-

-

8900

... More
Location survey for cable route and preparation of tentative cable route plan as per the instructions of Engineer in- Charge.

-

-

1

... More
(SOR NO 2502) "Excavation of trench, including marking of cable alignment, clearing of jungle, roots of trees, 2 bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO!CABLE LAYING!003, as directed by engineer incharge."

-

-

2271250

... More
(SOR NO 2516) "Cable laying at culverts/bridges -Low flood level- to take the cables underground across the drain bed at a depth of 1.2 meter for crossing small culverts with low flood level. After making the trench, the cable trench 12 shall be further dug at an interval of 4 meter to a depth of 0.5 meter and at such intervals concrete supports of 300mm X 500mm to a height of 0.7 meter shall be constructed using 1:3:6 concrete. The pipe shall pass through this concrete at proper height so that the pipe with cables inside it rests in the cable trench at 1 .2 Mtr depth. The concrete supports so cast shall be cured for a period of 5 days before filling the trench. During the curing period of 5 days, the culvert portion of cable laying shall be protected by keeping a watchman day and night."

-

-

80930

... More
(SOR NO 2517) Cable laying at culverts/bridges -High flood level : Excavation of cable trench of 300mm width and 800 mm depth in the ramp from the foot of the culvert on to the top of the culvert by storing the ballast and the 13 excavated soil separately and laying of HDPE/DWC/GI pipe( to be supplied by Railways). The pipe is to be laid , the cables required are to be drawn using bends( to be supplied by Railways) as per the drawing No.SK.15/11. After drawing the cables the bends are to be concreted to a size of 300mmX1000mmX1000mm using required shuttering with 1 cement: 3 sand: 6 graded stone aggregate 20mm nominal size and curing for required days. Except the HDPE/GI/DWC pipe and bends, all other material is to be arranged by the contractor.

-

-

17650

... More
(SOR NO 2523) Provision and laying cement concrete (including transportation of all the material). 17

-

-

79420

... More
(SOR NO 2603) Test lamp arrangement in LBs/RE cuttings (Auto mobile handle type).

110

178

19580

... More
(SOR NO 2605) Supply and fixing of following Teak wood reapers/ Blocks after applying two coats of wood primer.

-

-

81952

... More
(SOR NO 2608) Supply, painting and fixing of gland plate for Location box as per site requirement. 26

-

-

104760

... More
(SOR NO 2610) Excavation of pit in and around the existing location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway 27 representative at site. The work includes, ensuring the safety of the signalling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly reconnected. [All materials required for the work shall be supplied by the Contractor].

-

-

229480

... More
(SOR NO 2612) Alterations to painted termination/ wiring particulars of functions in the existing apparatus 28 cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signalling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re- numbering of apparatus cases and cable termination boxes (Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor).

-

-

12390

... More
(SOR NO 2710) Earthing and soldering of cable armour.(Per Unit = Per cable)

500

31

15500

... More
(SOR NO 2804) Fixing of junction type route indicator - 1 way to 6 way - complete / fixing of additional limb to 41 the existing route indicators, termination of tail cables, wiring as per approved circuits diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].

-

-

9420

... More
(SOR NO 3402 (a)) Initial Charging of Secondary Cells with uninterrupted Power Supply: - 2 volts 80 AH

160

328

52480

... More
(SOR NO 3501) Arranging of sufficient staff by contractor and giving test to the railway in charge in the following stages as per instructions.

-

-

61952

... More
(SOR NO 3917) Circuit Diagrams 96

-

-

72430

... More
(SOR NO 4501) Releasing of the following equipments without causing damage, stacking neatly at a centralised place near the site of work as shown by the in charge, and handing over the same to the Stores depot as per the inventory made.

-

-

286619

... More
(SOR NO 4638) Maintenance of 6 quad cables till handing over or at least for six months. This includes regular testing of Quad parameter from Station to Station, EC socket testing and recording in format specified by Railways. This item will commence only after joint testing of 6 quad cables with required parameters in a block section.

-

-

146352

... More
Site acceptance test and commissioning (inpection by Consignee)

1

301300

301300

... More
Supply of asmade documents (Inspection by Consignee)

1

300000

300000

... More
2(a) (i)- Concrete for foundations and plinth in hard soil. In M10 grade 2

-

-

69440.39

... More
2(a) (ii)-Concrete for foundations and plinth in rocky soil M10 grade. 3

-

-

76306.73

... More
2(b) Concrete for foundations and plinth in other than hard soil and rock 4

-

-

6412789.2

... More
1(a)Preparation of Designs and drawings. 2

-

-

101964.04

... More
1(d) Supply and installation of SWR boards and Flexi Sheets (Fixed on Decolum Sheets) at nominated places including supply of power block caps. 4

-

-

7862.32

... More
3(a) Erection of Traction masts and main masts and LT supply Transformer station. 5

-

-

179636.92

... More
3(b) Erection of fabricated steel work such as TTC, Portals etc. 6

-

-

681970.8

... More
3(c) Erection of fabricated Small Part Steel work etc. 7

-

-

454647.2

... More
3(e) Supply and erection of Guy rod assembly. 8

-

-

128369.47

... More
3(g) Supply of steel reinforcement for RCC work. 9

-

-

117422.04

... More
4(a)(i) Supply and Erection of Single bracket assembly without insulator for conventional OHE. 10

-

-

2330323.28

... More
4(a)(ii) Extra on 4(a) (i) for supporting two OHEs. 11

-

-

33073.02

... More
4(b)(i) Supply without Insulator and erection of a pull off arrangement for Conventional type OHE. 12

-

-

46738.07

... More
6(a) Erection of regulated conventional OHE. 13

-

-

487750.99

... More
7(d) Manual erection of all Aluminum 25 kV Feeder / Return conductor (spider). 14

-

-

5095.13

... More
8(a) (v) Supply and erection of regulating equipment (3 pulley type) with counter weight assembly for conventional OHE. 16

-

-

938632.82

... More
8(b)(ii) Supply without Insulator & erection of materials for termination of Double Overhead equipment conductors (Regulated).

-

-

74880.05

... More
8(b)(iii) Supply without insulator and erection of material for termination of all aluminum 25KV feeder/return conductor (single spider).

-

-

44182.82

... More
8(b)(ix)Supply (other than Insulators) and erection of materials for termination of copper cross feeder with gantries. 20

-

-

80930.62

... More
10(a) Extra on Item 6(a) for supply and erection of additional fittings at a turn-out,diamond crossing or overlap. 22

-

-

21

... More
11(a) (i) Supply and erection of 25 kV solid core cut-in insulator. 23

-

-

39961.1

... More
11(a) (ii) Supply and erection of 25 kV solid core suspension insulator. 24

-

-

46062.94

... More
11(b) Supply without insulator and erection of 25 kV Post Insulators. 25

-

-

42046.32

... More
12(a) Supply without insulator and erection of 25 kV section insulator assembly (Conventional type). 26

-

-

210137.59

... More
12(d) Erection of cermic/ Glasss Fibre PTFE type short neutral section assembly. 27

-

-

6435.14

... More
13(a)Supply and erection of 25 kV Single Pole Isolator with out earth contact assembly (without Insulators) 28

-

-

337259.34

... More
13(e) Extra on item 13 (a),(b) or [c] for an inter locking device. 29

-

-

6399.24

... More
15(e) Supply of materials and erection of large copper jumper wire 160 sq mm between cross feeders and OHE. 31

-

-

45994.57

... More
16(a) Supply and erection of structure bonds. 32

-

-

196558

... More
16(a)(ii) Dismantling of structure bonds. 33

-

-

4956.68

... More
16(a)(iii) Re-erection of structure bonds. 34

-

-

2478.34

... More
16(a)(iv) Supply and erection of structure bonds during NI working. 35

-

-

117934.8

... More
16(b) Supply and erection of longitudinal bond. 36

-

-

27945.42

... More
16(b)(ii) Dismantling of longitudinal bond. 37

-

-

4409.74

... More
16(b)(iii) Re-erection of longitudinal bond. 38

-

-

2204.87

... More
16(b)(iv) Supply and erection of longitudinal bond during NI working. 39

-

-

27945.42

... More
16(c) Supply and erection of transverse and special bonds. 40

-

-

18390.99

... More
16(c)(ii) Dismantling of transverse and special bonds. 41

-

-

5332.7

... More
16(c)(iii) Re-erection of transverse and special bonds. 42

-

-

5332.7

... More
16(c)(iv) Supply and erection of transverse and special bonds during NI working. 43

-

-

36781.98

... More
16(aa) Drilling of holes on rails. 44

-

-

23586.96

... More
17(a) Supply and erection of Earth electrode. 45

-

-

26075.56

... More
17 (c) Supply and erection of earth bus. 46

-

-

9400.6

... More
17(d) Supply and erection of Copper strips for equipment earthing. 47

-

-

1517.77

... More
26(a)(i) Supply and erection of Aluminium Bus-Bar 36 /28 mm 48

-

-

27176.28

... More
26(a)(ii) Supply and erection of 18 mm Copper Bus-bar. 49

-

-

388672.08

... More
26(a)(iii) Supply and erection of all types of Copper connnectors.. 50

-

-

161391.21

... More
26(b)(i) Supply and erection of all types Aluminium Bus-Bar and connectors(36/28) 51

-

-

55480.63

... More
28 Supply and Erection of 25 kV Drop out fuse switch for all oil/dry type L.T.Supply transformerss of all capacities

-

-

38231.39

... More
30(b)(iii) Supply and erection of anticlimbing device etc : L.T. stations 54

-

-

1134.91

... More
31(a) Transfer of equipment from one mast or support to other. 55

-

-

55420.81

... More
31(b) Provision of an additional bracket assembly / assemblies on a mast or support. 56

-

-

39311.6

... More
31(d) Dismantling of existing over Head Equipment 57

-

-

53301.4

... More
31(e) Dismantling feeder wire/Return Conductor. 58

-

-

2555.25

... More
31(f) Splicing and extension of Over head conductors. 59

-

-

21706.84

... More
31(g) Dismantling of a section Insulator assembly 60

-

-

4341.37

... More
31(g)(ii) Dismantling of a PTFE type short nutral section assembly from existing electrified lines. 61

-

-

4341.37

... More
31(h) Slewing of Equipment 62

-

-

17656.04

... More
31(i) Dismantling of an Isolator 63

-

-

8828.02

... More
31(k)(i) Dismantlement of OHE mast / structure by cutting. 64

-

-

41277.18

... More
31(k)(ii) Dismantlement of Uprights of TTCs/Portals by cutting. 65

-

-

39311.6

... More
31(l)(i) Retrieval of traction masts, main masts, TTC uprights etc. 66

-

-

97766.24

... More
31(o) Releasing of Multiple Cantilever Cross arm assemblies where single bracket assembly is leftover on MCC after modification 68

-

-

4443.92

... More
31(p) Dismantlement of drop arms/ booms / temporary masts. 69

-

-

22740.91

... More
31(r) Dismantling of Cantilever assemblies including insulators. 70

-

-

9742.44

... More
31(t)(i) Dismantling of a regulating equipment (3-pulley type) with counter weight assembly for Conventional OHE. 72

-

-

8357.99

... More
31(t)(iii) Dismantling of anticreep with galvanised Steel wire. 73

-

-

6195.85

... More
31(t)(iv) Dismantling of copper jumper 74

-

-

2290.33

... More
31(t)(vii) Dismantlement of materials of termination of all aluminum 25 KV feeder/ return conductor (single spider) 76

-

-

1922.85

... More
31(t)(xi) Dismantling of existing droppers 77

-

-

15724.64

... More
32/3(a) Erection of Traction masts and main masts of Switching stations and LT supply Transformer station under power block 79

-

-

26945.54

... More
32/3(b) Erection of fabricated steel work such as TTC, portals SPS etc. under power block 80

-

-

227323.6

... More
32/4(a) (i) Extra charges on Erection of Single braket assembly suitable for Conventional type OHE (Regulated) under power block 82

-

-

77768.6

... More
32/7(d) Extra charges on Manual erection of all Aluminum 25 kV Feeder / Return conductor (spider) under power block 84

-

-

2340.75

... More
32/8(b) (ii) Extra charges on Erection of materials for termination of Double Overhead equipment conductors (Regulated) under power block

-

-

7708.49

... More
32/9(a) Extra charges on Erection of anti creep with galvanised steel wire suitable for Conventional OHE. (Regulated) under power block

-

-

19813.05

... More
32/10(a) Extra charges on erection of additional fittings at a turn out diamond crossing or overlap under power block 89

-

-

5093.42

... More
32/11(a) (i) Extra charges on Erection of 25 kV solid core cut-in insulator under power block 90

-

-

10631.22

... More
32/11(a) (ii) Extra charges on Erection of 25 kV solid core suspension insulator under power block 91

-

-

7947.78

... More
32/12(a) Extra charges on Erection of 25 kV Section Insulator assembly suitable for Conventional type OHE under power block

-

-

13229.21

... More
32/12(d) Extra charges on Erection of cermic/ Glasss Fibre PTFE type short neutral section assembly under power block

-

-

2346.73

... More
32/13(a) Extra charges on Erection of 25 kV Single Pole Isolator with out earth contact assembly under power block 95

-

-

12263.51

... More
32/15(a) Extra charges on Erection of all types of copper jumpers under power block 96

-

-

9092.94

... More
32/15(e) Erection of large copper jumper wire 160 Sq mm between Cross feeder and OHE under power block 97

-

-

4546.47

... More
32/26(a)(i) Extra charges on Erection of Aluminium Bus-Bar 36 /28 mm under power block 98

-

-

598.22

... More
32/26(a)(ii) Extra charges on Erection of 18 mm Copper Bus-bar. under power block 99

-

-

2153.59

... More
32/26(a)(iii) Extra charges on Erection of all types of Copper connnectors under power block 100

-

-

435.85

... More
32/26(b)(i) Erection of all types Aluminium Bus-Bar and connectors(36/28) under power block 101

-

-

786.23

... More
32/31(b) Extra on Provision of an additional bracket assembly / assemblies on a mast or support under power block. 103

-

-

19655.8

... More
32/31(d) Extra charges on Dismantling of Existing Over Head Equipment under power block. 104

-

-

53301.4

... More
32/31(f) Extra on Splicing and extension of Over head conductors under power block. 105

-

-

21706.84

... More
32/31(g)(ii) Extra charge on Dismantling of a PTFE type short nuetral section assembly from existing electrified lines 107

-

-

4341.37

... More
32/31(h) Extra charges on slewing of equipment under power block. 108

-

-

8828.02

... More
32/31(k) Extra charges on Dismantlement of OHE mast / structure by cutting under power block. 109

-

-

27518.12

... More
32/31(l)(i) Extra charges on Retrieval of traction masts, main masts, TTC uprights etc. under power block. 110

-

-

97766.24

... More
32/31(o) Extra charges on Releasing of Multiple Cantilever Cross arm assemblies where single bracket assembly is leftover on MCC after modification under power block. 112

-

-

4443.92

... More
32/31(r) Extra charges on Dismantling of Cantilever assemblies including insulators under power block. 113

-

-

9742.44

... More
32/31(t)(i) Extra charges on Dismantling of a regulating equipment (3-pulley type) with counter weight assembly for Conventional OHE under power block. 115

-

-

8357.99

... More
32/31(t)(iii) Extra charges on Dismantling of anticreep with galvanised Steel wire\ under power block 116

-

-

6195.85

... More
32/ 31(t)(v) Extra charges on Dismantling of material of termination of over head equipment (Reg.) under power block.

-

-

8819.47

... More
32/31(t)(vii) Extra charges on Dismantlement of materials of termination of all aluminum 25 KV feeder/ return conductor (single spider) under power block 119

-

-

1922.85

... More
32/31(t)(xi) Extra charges on dismantling of existing droppers under power block. 120

-

-

7862.32

... More
32/31(t) (xii) Extra charges on re-adjustment of OHE spans including erection of droppers under power block 121

-

-

39311.6

... More
32/43 Splicing of all types of booms under power block 122

-

-

38980.02

... More
33/ 3(a) Extra on erection rate for steel work done manually under item No. 3(a) 123

-

-

89562.08

... More
33 / 3(b) Extra on erection rate for steel work done manually under item No. 3(b) 124

-

-

568095.35

... More
33/ 6(a) Extra on erection rate for stringing work done manually under item 6(a), 7(d) 125

-

-

51152.94

... More
34 (f) (i) Earth work in excavation and filling including compaction in Normal soil. 126

-

-

9229.68

... More
34 (l) Pitching and grouting on side slopes with contractors stone including plastering 127

-

-

51361.46

... More
36(a) Unloading of all type of Steel Structures. 128

-

-

1982.67

... More
36(b) Loading of all type of Steel Structures. 129

-

-

3213.3

... More
37(a) Unloading of all type of Copper & Aluminum conductors. 130

-

-

181.18

... More
37(b) Loading of all type of Copper & Aluminum conductors. 131

-

-

181.18

... More
39(a) Erection of released guy rod. 132

-

-

4913.95

... More
39(b) Erection of released bracket assembly. 133

-

-

137590.6

... More
39(d) Erection of released termination. 134

-

-

9827.9

... More
39(e) Erection of released additional fittings at turnouts, diamond crossing and over laps 135

-

-

5580.54

... More
39(i) Erection of released copper jumper 136

-

-

2512.52

... More
40 Supply and erection of Number Plates on existing masts 137

-

-

113234.5

... More
3(a)Supply of Traction masts and main masts of switching stations, LT supply transformer station as per RDSO drawings and IS Specifications.

-

-

11038705.5

... More
3(b)Supply of fabricated steel work other than masts such as TTC's (with 8.0m and 5.5m booms), portal sets (with all components) as per RDSO drawings and IS specifications. 3

-

-

8441054.48

... More
15(a)(i) Supply of 160 sq.mm Annealed Stranded Copper jumper wire as per specification. 4

-

-

485918

... More
15(a)(ii) Supply of 130 sq.mm Cadmium copper large span wire as per specification. 5

-

-

536601.5

... More
15(a)(iii) Supply of 105 sq.mm Annealed Stranded Copper jumper wire as per specification. 6

-

-

10732.03

... More
4(ax)(i) Supply of Stay & Bracket insulator set for item 4(a)(i) (iii) (v). 2

-

-

3254224

... More
8(bx)(i) Supply of 9-ton insulators for item no. 8(b)(i) /(ii)/(iii)/(v)/(vi)/(vii)/(viii)/(ix). 3

-

-

175827.52

... More
8(bx)(ii) Supply of 9-ton insulators for item no.8(b)(i) /(ii)/(iii)/(v)/(vi)/(vii)/(viii)/(ix) for polluted zone. 4

-

-

211008.32

... More
9(ax)(i) Supply of 9-ton insulators for item no.9(a), (b),(c). 5

-

-

351731.52

... More
11(ax)(i) Supply of 25KV solid core insulators for item no 11(a)(i),(ii). 6

-

-

175827.52

... More
11(ax)(ii) Supply of 25KV solid core insulators for item no 11(a)(i),(ii) for polluted zone. 7

-

-

105504.16

... More
11(bx) Supply of 25KV Post insulator for 11(b). 8

-

-

228598.72

... More
12(ax) Supply of bar insulator + 9 T Cut in Insulator for item No.12(a). 9

-

-

175842.82

... More
13(ax) Supply of Post & Operating rod insulators for item Nos.13(a). 10

-

-

174122.02

... More
12 (d) PTFE Short Neutral Section Assembly Complete [Phase Break] Suitable for 107 Sq.mm Grooved Copper Contact Wire and 65 Sq. mm Cadmium Copper Catenary Wire as per RDSO Specification no.TI/SPC/OHE/SNS/0000 Rev.1 with A& C slip no.1 or latest.

-

-

1085154.57

... More
27(a)(ii)Supply of 10 kVA, 25 kV/240V, L.T. Supply Transformer (oil type) as per RDSO spec. No.ETI/PSI/15 (11/92) or latest.

-

-

466700.82

... More
27(a)(iii)Supply of 25 kVA, 25 kV/240 volts LT supply Transformers (Oil type) as per latest RDSO Specification No. ETI/PSI/15 (11/92) or latest. 5

-

-

284332.43

... More
28(a) Supply of link pull rod for 25 KV D.O.fuse switch as per latest RDSO spec. 6

-

-

43346.05

... More
31(f)(i) Supply of Contact wire Splice. 7

-

-

12378.62

... More
31(f)(ii) Supply of catenary wire Splice. 8

-

-

4876.88

... More
31(f)(iii) Supply of Large span wire ending clamp. 9

-

-

27963.75

... More
Breaking of mass concrete by using pneumatic breaker (tractor mounted) incl.disposal of debris out of the yard limits incl. crossing of tracks, rehandling etc. 11

-

-

294640.98

... More
Supply and erection of burried rail arrangement in all aspects with railway supplied rail. 12

-

-

39730.9

... More
41(a)(iii) Supply and erection of public caution boards. 15

-

-

80535.6

... More
41(a)(iv) Supply and erection Danger board for L.C. gate height gauge. 16

-

-

46233.4

... More
41(a)(v) Supply and erection of working limit board. 17

-

-

156597

... More
41(a)(vi) Supply and erection of shock treatment chart. 18

-

-

7457

... More
41(b)(i)Supply and erection retro reflective signal board at warning neutral section 250m as per latest RDSO specification.

-

-

16703.68

... More
41(b)(ii)Supply and erection retro reflective signal board at warning neutral section 500m as per latest RDSO specification.

-

-

16703.68

... More
41(b)(iii)Supply and erection retro reflective signal board at warning neutral section 'DJ ON' as per latest RDSO specification.

-

-

16405.4

... More
41(b)(iv)Supply and erection retro reflective signal board at warning neutral section 'DJ OFF' as per latest RDSO specification. 23

-

-

16405.4

... More
Rachet Lever Hoist (Pull lift) 3.2 Tonne Capacity.As per RDSO SPEC: TI/SPC/OHE/TOOLPL/1991 Rev-1, STR:TI/STR/007 Revision-2 WITH ROLLER CHAIN 1.5 MTRS.LONG.

-

-

200010

... More
Supply of safety 33000 volts electrical hand gloves, seamless natural latex rubber of size :300mm, Colour:Cream with stand test potential:33000 volts , maximum working potential:7500 Volts as per IS:4770-1991 of 4

-

-

81184

... More
Rail Jumpers made of multistrand copper PVC Cable 248/0.457mm size with suitable clamps at both ends as per RDSO specification no ETI/OHE/3/(2/94) with A& C slip No. 1(04/95) or latest and as approved by Engineer-3 meter length.

-

-

76300

... More
Rail Jumpers made of multistrand copper PVC Cable 248/0.457mm size with suitable clamps at both ends as per RDSO specification no ETI/OHE/3/(2/94) with A& C slip No. 1(04/95) or latest and as approved by Engineer-5 meter length.

-

-

41640

... More
Rail Jumpers made of multistrand copper PVC Cable 248/0.457mm size with suitable clamps at both ends as per RDSO specification no ETI/OHE/3/(2/94) with A& C slip No. 1(04/95) or latest and as approved by Engineer-13 meter length 8

-

-

64340

... More
Come along clamps LS 9

-

-

70800

... More
Come along clamps catenary. 10

-

-

70800

... More
Come along clamps Contact 11

-

-

46000

... More
Heavy duty pulley 3Tone. 12

-

-

54280

... More
Heavy duty pulley 1Tone. 13

-

-

34440

... More
Pull lift 0.75Tone. 14

-

-

114460

... More
Supply & Erection of Eye rod 1.8 Mtr.Long 20mm DIA with Fasteners counter weight as per RDSO DRG. No.ETI/OHE/SK/588.

-

-

48417.8

... More
Supply & Erection of Set of cast iron counter weight (140 Kg) consisting of 03 nos. 40 Kg. (RI no. 5092) & one20Kg. for regulating equipment.

-

-

155101.05

... More
Supply & Erection of Three Pulley ATDas per RDSO specification for 2400kgf Tension as per RDSO specification no.TI/SPC/OHE/ 3PHTATD/ 0150 With ACS 1. 4

-

-

272350.2

... More
Supply & Erection of 12.24 mm dia ACSR Raccoon with suitable fasteners.(AEC) 5

-

-

436550.31

... More
Supply & Erection of 20mm dia galvanized steel conductor with suitablefasteners.(BEC) 6

-

-

291632.74

... More
Supply & Erection of Tee connector for BEC end and lug for connection. 7

-

-

398060

... More
Digging of trench 300mm deep. 8

-

-

186077.5

... More
BEC Laying and Back filling of trench 300mmdeep 9

-

-

178634.4

... More
Supply & Erection of 25KV 1600Amps DP Isolator with out insulator earth contact assembley terminal connectors & Interlock as per RDSO Specification. 11

-

-

2159656.5

... More
Supply without Insulator and erection of 9Tonne Insulator for termination of AEC. 12

-

-

19420

... More
Cable Route Maker for B.E.C.@ Distance of 150m. 13

-

-

121500

... More
Supply and concealed laying in Roof/Wall/Slab/floor of size OD 32 mm dia 2 mm thick UPVC conduit pipe (ISI marked) HMS (Heavy Mechanical stress) FRLS with all required accessories such as deep boxes, bends, junction boxes etc. including grooving (if required), masonary work and labour charges etc.

-

-

30000

... More
Supply and concealed laying in Roof/Wall/Slab/floor of size OD 25 mm dia 2 mm thick UPVC conduit pipe (ISI marked) HMS (Heavy Mechanical stress) FRLS with all required accessories such as deep boxes, bends, junction boxes etc. including grooving (if required), masonary work and labour charges etc.

-

-

36000

... More
Wiring with two runs of 1.5 Sq.mm. 1100 V and one run of flexible copper conductor 1.5 Sq.mm. 1100 Volts 03 FRLS PVC inulated wires ISI makred (Phase, neutral and earth) in the UPVC conduit pipe with 6A flush modular type switch including 2 way switches where ever required, 6A bell push modular type switch, ceiling rose, bulb holder and modular type plate cover to G.I. switch control box including all labour charges complete for light points, ceiling fan point and exhaust fan points etc.

-

-

84812

... More
Supply, fixing, connecting and commissioning of 6A 5 pin modular plug socket with 6A modular control switch on existing control board with wiring

-

-

13366

... More
Supply and fixing of 16A 5 pin flush power plug and socket and 16A switch control (5 in one) GI box with Top plate cover control for power plug point connection and all labour charges etc.

-

-

12120

... More
Supply and fixing of 20/32/40 Amps metallic plug & socket (industrial type) with 25/32 Amps SP MCB housed in GI switch box with necessary connections.

-

-

2554

... More
Supply, fixing, connecting and commissioning of 20 Watts 1200 mm LED tube light fitting with lamp including wiring, connecting etc. as per latest PCEE's specification

-

-

65871

... More
Supply, fixing, connecting and commissioning of 28 W Energy Efficient BLDC ceiling fan with Remote as per latest PCEE's specification

-

-

141351

... More
Supply, fixing, connecting and commissioning of Energy Efficient Exhaust fan of 300 mm sweep with louvers including necessary holes and masonary work etc.

-

-

27624

... More
Supply, laying, connecting and commissioning of single core 1.5 Sq.mm. 1100 PVC (FRLS) insulated multi stranded copper conductor wires confirming to IS:694/1990 and ISI marked in existing PVC conduit pipe

-

-

14400

... More
Supply, laying, connecting and commissioning of single core 2.5 Sq.mm. 1100 PVC (FRLS) insulated multi stranded copper conductor wires confirming to IS:694/1990 and ISI marked in existing PVC conduit pipe

-

-

40000

... More
Supply, laying, connecting and commissioning of single core 4.0 Sq.mm. 1100 PVC (FRLS) insulated multi stranded copper conductor wires confirming to IS:694/1990 and ISI marked in existing PVC conduit pipe for circuit points

-

-

39600

... More
Supply, laying, connecting and commissioning single core 6 Sq.mm. 1100 V PVC (FRLS) insulated multi stranded copper wires confirming to IS:694/1990 and ISI marked in existing PVC pipe for sub distribution boards as run of supply mains/higher including all labour charges

-

-

39200

... More
Supply, laying, connecting and commissioning of single core 10 Sq.mm. 1100 Volts PVC (FRLS) insulated multi stranded copper wires confirming to IS:694/1990 and ISI marked in existing PVC pipe for sub Distribution boards as run of supply mains/Higher including all labour charges

-

-

15000

... More
Supply, laying, connecting, testing and commissioning of 4 core 120 Sq.mm. LT XLPE UG cable 1100 Volts as per IS:7098/Part-I/1988 or latest

-

-

417000

... More
Supply, laying, connecting, testing and commissioning of 4 core 70 Sq.mm. LT XLPE UG cable 1100 Volts as per IS:7098/Part-I/1988 or latest

-

-

296500

... More
Supply, laying, connecting, testing and commissioning of 4 core 50 Sq.mm. LT XLPE UG cable 1100 Volts as per IS:7098/Part-I/1988 or latest

-

-

216500

... More
Supply, laying, connecting, testing and commissioning of 4 core 25 Sq.mm. LT XLPE UG cable 1100 Volts as per IS:7098/Part-I/1988 or latest

-

-

55500

... More
Supply, laying, connecting, testing and commissioning of 4 core 16 Sq.mm. LT XLPE UG cable 1100 Volts as per IS:7098/Part-I/1988 or latest

-

-

168000

... More
Supply, laying, connecting, testing and commissioning of 2 core 150 Sq.mm. LT XLPE UG cable 1100 volts as per IS:7098/Part.I/1988 or latest.

-

-

1842000

... More
Supply, laying, connecting, testing and commissioning of 2 core 70 Sq.mm. LT XLPE UG cable 1100 Volts as per IS:7098/Part-I/1988 or latest

-

-

510000

... More
Supply and fixing of GI wire of size 8 SWG for providing earthing interconnections along the UG cables with all other connected accessories 23

-

-

112500

... More
Supply and laying of 50 mm dia of B class GI pipe including all accessories etc. 24

-

-

32500

... More
Supply and laying of HDPE pipe of PE-80 grade in PN-4 size 4" inner dia and outer dia 110 mm and wall thickness minimum 4.3 mm, maximum 4.8 mm with 'T' joints, bolts, elbows etc. including all other connected accessories

-

-

124650

... More
Supply and laying of HDPE pipe of PE-80 grade in PN-4 size 2" inner dia and outer dia 63 mm and wall thickness minimum 2.5 mm, maximum 2.8 mm with 'T' joints, bolts, elbows etc. including all other connected accessories

-

-

715000

... More
Excavation of cable trench in ordinary soil to depth of 1250x450mm filling the trench (after laying the cables) to bring the original condition

-

-

838500

... More
Excavation of cable trench under rock/CC/Tar/RCC road/Track and making good providing cement concrete after laying the cable 29

-

-

174000

... More
Supply and fixing of HT/LT cable route indicators as per the details given in the drg. No. DEE/CN/BZA/2001/23 30

-

-

243000

... More
Design, Fabrication, supply, erection, testing and commissioning of cubicle type 14 SWG LT weather proof (out door type) main distribution board panel with copper busbar of 600 Amps capacity including Ammeter, voltmeter, selector switches and RYB indication and Digital KWH meter with RS485 Port meters CT's of suitable ratio etc. in general confirming to Rly. spec. No. B/E.CN/Spec/01 with the following switch gear. For each outgoing MCCBs LED indication in on position to be 31 provided, MCCB should be provided with Ammeter, Voltmeter, selector switches and RYB indicaton lamps. LT panel board should confirming to IS:8263, MCCB's should be confirming to IS:2516. Arrangements of switch should be lockable & shutdown condition to avoid electrician and MCCBs feeder details stricking on the panel 1x320 A 4 pole MCCB 50 KA incoming, 3x100 A TP MCCB 25 KA out going, 3x63 Amps TP MCB 10 KA out going, 2x40 Amps TP MCB 10 KA outgoing, 4x32 Amps TP MCB 10 KA outgoing, 1x50 KVAR power capacitor and 1x320 Amps Change over switch 1 No. Three phase Electronic Energy meter with CT's of suitable ratio

-

-

200375

... More
Construction of masonry plinth of suitable size for installation of LT main distribution board panel with all 32 connected works including required hardware etc. complete. The scope also includes fixing of the panel on the masonry plinth with suitable clamps and connected hardware. This work is to be executed as per the planning and instructions of Railway site Engineer

-

-

4600

... More
Supply & fixing of 8 way Vertical TPN distribution board fixed on wall with the following switches 1x160 Amps 25 KA 4 pole MCCB for incoming and 4 Nos. of 63 Amps TP MCB, 4 Nos of 32 Amps TP MCB, 4 Nos. of 20 Amps DP MCB, 4 Nos of 10 A SP MCBs for outgoing

-

-

98882

... More
Supply and fixing of 6 way TPN double door with lock & key distribution board with 1x32 TP MCB for incoming and 3 Nos. of 20 Amps DP MCB, 6 Nos. of 20 A SP MCBs outgoing including internal connections, grouting, earthing, fixing, testing and all labour charges etc. including cable entry box and trunking arrangement

-

-

34

... More
Supply, fixing, connecting, installation, testing and commissioning of Automatic change over panel complete 35 for colour light signaling system having 3 phase supply 150 Amps capacity with all connected accessories viz. Rotary selector switch, air break contractor, MCCBs, MCBs, LEDs, alarm buzzer, alarm reset micro switch etc. meeting RDSO technical specification No. TI/SPC/PSI/CLS/0020 with latest amendment

-

-

182000

... More
Supply, fixing, connecting, installation, testing and commissioning of Automatic change over panel complete 36 for colour light signalling system having 3 phase supply 60 Amps capacity with all connected accessories viz. Rotary selector switch, air break contractor, MCCBs, MCBs LEDs alarm buzzer, alaram reset micro switch etc. meeting RDSO technical specification No. TI/SPEC/PSI/CLS/0020 with latest amendment 37

-

-

58562

... More
Supply, fixing, connecting and commissioning of Weather proof terminal box with Bimetallic bus bar with clamp bolts nuts including all accessories etc. (For AT) as per Drg No. E.252/TrD/HQ/AT-JB/2022-23 (Alt-1)

-

-

24000

... More
Supply, fixing and commissioning of 160 A 4 pole MCCBs with 25 KA breaking capacity (for AT terminal box as per enclosed Drawing).

-

-

6432

... More
Supply, fixing and commissioning of 63 A 4 pole MCCB with 16 KA breaking capacity (for AT terminal box as per enclosed Drawing).

-

-

3890

... More
Supply, erection and commisioning of 5 mtr long dip galvanised octagonal pole with 130 mm bottom A/F & 70 41 mm top A/F made up of 3 mm thick HT sheet along with base plate of size 200x200x12mm, M16x600 long 'J' type EN 8 grade foundation bolts, 1000 mm long single/double arm bracket (as per site requirement) with concrete foundation and plinth in hard soil including excavation of soil, tamping of concrete grouting with Bakelite sheet and MCB (for mounting inside the base compartment of Pole) with all accessories

-

-

501630

... More
Supply, fixing, testing and commissioning of 40 Watts AC LED street light luminaries with glass IP 65 including all connected accessories etc. as per latest PCEE's Specification

-

-

86796

... More
Fixing and commissioning of LED street light fitting on wall with 1.2 mtr/required length of ISI marked 'B' class GI pipe/Bracket (as necessary) of 2" dia/suitable dia with clamps, bolts and nuts etc. including internal connections complete

-

-

1872

... More
Supply of FRP ladder type cable tray of size 310mmx80mmx3mm thickness including all accessories. The entire work has to be carried out as per the instruction and guidelines of Railway site Engineer

-

-

37000

... More
Erection of FRP ladder type cable tray of size 310mmx80mmx3mm thickness along with supply and fixing of clamping arrangements at regular intervals by MS strip of size 40mmx5mm thick including powder coating. The entire work has to be carried out as the instructions and guidelines of Railway site Engineer.

-

-

13350

... More
Design, Supply, installation, commissioning including transportation of complete set of 10 kWp solar photovoltaic system including connecting to the existing grid/local supply through suitably designed power conditioning unit 46 (PCU) on the roof top of building. Complete set consists of Solar panels, module mounting structure, junction boxes, power conditioning unit (PCU), Import & Export metering, cable and other accessories as per RDSO specification No. RDSO/PE/SPEC/PS/0092-2008 (Rev-0) Amdt. 4 October 2012 or latest. The Solar Photovoltaic system (SPVS) to be erected over terrace of building and the output is to be connected at Main distribution board (The rate Excludes annual Maintenance Contract cost)

-

-

804513

... More
Supply, fixing, installation & commissioning of 2 Ton 5 star capable of delivering 24000 BTU/hr and above with operating on refrigerant R-410A/R-32 INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit 47 and outdoor condencing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc. inclduing suitable wall mounting bracket for fixing of outdoor unit, dual barrier coating in order to protect coil from oxidigation 48

-

-

125000

... More
Design, supply, fixing, testing and commissioning of ON delay timer circuit arrangements for 2 platform 49 lightings ON/OFF operation in 1.6 mm thick CRCA sheet enclosure of 16"x12"x8" size with door and lock & key arrangement comprises following switchgears including stickering and all other connected accessories complete. a) 2 Nos. of micon 225 Timer b) 2 sets of 3 pole contactor 45A AC1 (25A AC3) c) 2 sets of ON push button with elements d) 2 sets of LED indication lamps e) 8 way/2 sets of 4 way terminal connector & internal wiring arrangements

-

-

9432

... More
Supply, fixing, connecting and commissioning of SMC cable termination junction Box of size 250x200x105 with shock proof, rust proof, fire resistant, weather proof with IP65 potection suitable for termination of 2/4 core LT UG cables upto 70 sq.mm., 3 phase 415 volts including hylam sheet, heavy duty terminal connections, clamping arrangements etc.

-

-

23100

... More
Supply, fixing, connecting and commissioning of SMC cable termination junction Box of size 340x200x105 with 51 shock proof, rust proof, fire resistant, weather proof with IP65 protection suitable for termination of 2/4 core LT UG cables upto 150 sq.mm., 3 phase 415 volts including hylam sheet, heavy duty terminal connections, clamping arrangements etc.Note: Makes as per approved list of CEE/C/SC

-

-

26000

... More
Supply, erection and commissioning of 3 phase 4 way loop-in/loop-out junction box of size 10"x10"x6" with suitable hinged door, adequately gasketted to maintain insect proof, having locking arrangements to be fixed on wall/pole including all required connected accessories. The box shall be served with two prime coating of red oxide & finished with ash colour paint 53

-

-

4260

... More
Supply, fixing, connecting and commissioning of DP metal enclosure with One No. of 40 Amps DPMCB including provision for timer & contactor fixing with all necessary accessories etc. 55

-

-

4108

... More
Supply and Fixing of AC operated heavy duty 230 /440 Volt power contactor 32 Amps conforming to IS:13947- 4-1/IEC:947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required.

-

-

3440.88

... More
Supply and erection of Earth electrode of 48.4 mm outer dia & 40 mm inner dia, 3.1 m long steel tube 57 galvanised with welded MS galvanised lug as per drawing No. ETI/OHE/P/7021 & RDSO specification No. TI/SPC/PSI/ERTHNG/0210 or latest including excavation of pit, protective concrete box with cover and all other connected materials like GI wire, charcoal, salt etc.

-

-

95350

... More
Supply, Laying and connecting of GI flat of size 50x6 mm with all accessories such as bolts and nuts etc. complete for earthing interconnections

-

-

16500

... More
Supply, fabrication, fixing and connecting of MS sheet iron box of size 1.10 Mtrs. x 1.50Mtrs. x 0.55 Mtrs. MS 59 sheet not less than 16 SWG and 4 Nos. of 200 Amps Fuse cutouts with masonry plinth, clamps, bolts, nuts and locking arrangements. The box shall be painted with two coats of red oxide and two coats of siemens grey paint with all accessories for supply points

-

-

16122

... More
Design, fabrication, supply, erection and commissioning of suitable size MS sheet iron box, MS sheet not less than 16 SWG with clamps, bolts, nuts, washers, box shall be painted with two coats of red oxide and two coats of Siemens Grey paint with all accessories for supply points

-

-

2500

... More
Fabrication, Supply and fixing of clamping arrangements for LED station name boards, necessary cross 61 arms/rag bolts to fix the boards at a specified location to wall/roof is also to be supplied by the contractor as advised by Site Engineer. The wiring is to be made by 2 Nos. of 1.5 sq.mm. PVC insulated multi stranded copper wire through 1/2" PVC conduit pipe/casing and capping/PVC flexible pipe of good quality along with 14 SWG bare copper wire for earth continuity

-

-

1935

... More
Suppy, fixing, testing and commissioning of LED based station Name Board in English/Telugu/ Hindi on the basis of number of letters per board in RGB colour complete with all connected accessories. The complete board shall confirms to specification No. GTL/E/M /SPEC /LED/10/1

-

-

248283

... More
Design, fabrication, supply and fixing of LED double side glow sign boards with high quality LED's with 63 computerised vinyl stickering lettering in 'Telugu', 'Hindi', 'English'. The signage pictorials shall be as advised by Site Supervisor with all other connected accessories complete as per RDSO specification No. RDSO/PE/SPEC/PS/0086-2009 (Rev. '0') Amdt-1

-

-

52480

... More
Fabrication, Supply and fixing of GI clamping arrangements for single side/double side glow boards of 64 25"x25"/49"x25"/other required sizes etc. necessary GI cross arms/GI rag bolts to fix the boards at a specified location to wall/roof is also to be supplied by the Contractor as advised by site Engineer. The wiring is to be made by 2 Nos. of 1.5 sq.mm. PVC insulated multi stranded copper wire through 1/2" PVC conduit casing and capping along with 14 SWG bare copper wire for earth continuity

-

-

5000

... More
Supply, fixing, connecting and commissioning of a) 3 Nos. of 6 Amps one way with LED indicator switch, b) 3 Nos. of International socket, 16/6 Amps (shuttered), c) 1 No. 16 A SP Tiny Trip MCB, d) 2 Nos. of Plastic Enclosures with cover for surface mounting including fixing of charging point on the wall complete with all other connected accessories etc.

-

-

4324

... More
Supply and fixing of suitable rack arrangements for cell charging a) supply of 18 SWG sheet steel of size 0.38 66 mtr. x 0.3 mtr. and Bending to required shape & drilling of 4 Nos. of holes at the top of the sheet, b) Painting of above items for one coat of Red-oxide and two coats of ivory colour including fixing on the wall complete with all other connected accessories etc.

-

-

1868

... More
Design, Fabrication, supply, erection, testing and commissioning of 16 Mtrs. special steel plates high mast shaft system, including wiring with PVC insulated copper flat cable complete made up of two sections as per the specification No. SCR/EL/HMTL/2002/01 enclosed with all accessories except those mentioned as separate item in this schedule. (i) Supply and fixing of accessories for 16 M high mast including head frame, stainless steel wire rope 6mm dia. double drum winch, 67 motor, galvanized lantern carriage arrangements suitable for 9 luminaires and with its control gear box with all connected material (ii) Excavation of earth design & casting M 20 concrete foundation for 16 mtrs high mast with all connected works and supply of required materials (iii) Supply and fixing of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates with all connected material (iv) Supply, fixing and commissioning of 3 phase non reversible power tool for electrical operation of raising and lowering of lantern carriage with all connected materials as per the specification No. SCR/EL/HMTL/2002/01

-

-

397228

... More
Supply, fixing, connecting and commissioning of Energy saving IP65 flood light luminaries with high power LED Light of 200 Watts including all connecting accessories as per PCEE's Specification No. SCR/LED (OD)/Light Fittings/003 (Amdt.5) - 2023 or latest

-

-

165024

... More
Supply, fixing and connecting of copper cable of 2 core x 4 sq.mm with all connected accessories Note: Makes as per approved list of CEE/C/SC

-

-

69

... More
Supply, fixing and connecting of 4 pole 100 Amps MCCB, 25 KA to be fixed at existing LT control panel board complete with all connected accessories etc.

-

-

4339

... More
Supply, fabrication and erection of protective fencing around the high mast with 50mm dia x 1.5 mtrs. long medium class GI pipe 10 Nos. and ornamental chain made of 5mm dia rod shackles and length of not less than 18.5m of each round including all masonry works for retaining wall as per site required.

-

-

4939

... More
Supply, installation, testing and commissioning of 1.4 kVA, 24 V DC inverter pure sine wave output, single phase input/single phase output and internal cable connection

-

-

13200

... More
Supply and fixing of 12V 100 AH SMF battery with 3 years warranty including wire leads, connections etc. complete 74

-

-

22968

... More
Dismantling of RSJ/RCC/Tublar/Platform poles and handing over the same to the concerned supervisor of maintenance his stores.

-

-

20000

... More
Preparation and submission of completion drawings in A3 size with all relevant details and executed Wiring diagrams. The drawings shall be submitted in 1+6 copies etc. along with AUTOCAD CD

-

-

1000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.