Roads And Buildings Department Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Roads And Buildings Department Tender

Works
Civil And Construction
Road Construction
Opening Date13 Feb 2024
Closing Date27 Feb 2024
Tender Amount₹ 2,67,74,856 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vibrated cement concrete in Open foundations complete as per Drawing and technical specifications as per MORT&H (5th revision ) specification Nos.1500, 1700 & 2100 VCC M-20-Footings of abutments & wing walls

64

499136

7799

... More
Vibrated Reinforced Cement Concrete in open foundation complete as per Drawing and Technical Specifications and as per MORT&H (5th revision ) specification Nos. 1500, 1700 & 2100.---VRCC M-25- Footings

72

597744

8302

... More
Providing and Laying Cutting Edge of Mild Steel weighing 40 kg per metre for Well Foundation complete as per Drawing and Technical Specification. 1200 & 1900

1.6

195122

121951

... More
Vibrated Reinforced Cement Concrete in well foundation complete as per Drawing and Technical Specifications and as per MoRTH (5th revision ) specification Nos. 1200, 1500 & 1700 M-25 for Well Curb

16

153632

9602

... More
Plain Vibrated Cement Concrete in well foundation complete as per Drawing and Technical Specification and as per MoRTH (5th revision )specification Nos.1200, 1500 & 1700. M-20-Well Steining

100

824900

8249

... More
Plain Cement Concrete in well foundation complete as per Drawing and Technical Specifications and as per MoRTH(5th revision ) specification Nos.1200,1500 & 1700. M-20 Bottom Plug Concrete with 10% extra cement to be placed using tremie pipe

55

470745

8559

... More
Sand filling in wells complete as per drawing and technical specifications as per MORTH (5th revision) specification No. 1207

158

361504

2288

... More
Plain Vibrated Cement Concrete in well foundation complete as per Drawing and Technical Specifications and as per MOST(5th revision ) specification Nos. 1200, 1500 & 1700.---M-20- Top Plug

13

97487

7499

... More
Vibrated Reinforced Cement Concrete in well foundation complete as per Drawing andTechnical Specifications and as per MoRTH(5th revision ) specification Nos. 1200, 1500 & 1700.---M-25- Well Cap

54

448308

8302

... More
Sinking of 7 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level (well cap bottom). as per MORT&H specification No. 1200. For piers in sandy soils upto 3m depth

3

48510

16170

... More
Sinking of 7 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level (well cap bottom). as per MORT&H specification No. 1200. For piers in sandy soils - 3m to 10m depth

4.1

89335

21789

... More
Sinking of 7 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level (well cap bottom). as per MORT&H specification No. 1200. in soft rock

1.5

51228

34152

... More
Plain Vibrated Cement Concrete in sub structure complete as per Drawing and Technical Specifications and as per MORT&H(5th revision) Nos.1500,1700 & 2200.-VCC -M-20 Substructure for wing walls and abutments

154

1270346

8249

... More
Vibrated reinforced Cement Concrete in sub structure complete as per Drawing and Technical Specifications and as per MoRTH specification Nos.1500,1700 & 2200 excluding cost of reinforcement M-25 Sub structure bed blocks & backing wall height up to 5m

23

202446

8802

... More
Vibrated reinforced Cement Concrete in sub structure complete as per Drawing and Technical Specifications and as per MoRTH specification Nos.1500,1700 & 2200 excluding cost of reinforcement M-25 Sub structure for Piers, Piers hammer head bed blocks & Pedestals up to 5m

62

545724

8802

... More
Vibrated reinforced Cement Concrete in sub structure complete as per Drawing and Technical Specifications and as per MoRTH specification Nos.1500,1700 & 2200 excluding cost of reinforcement M-25 Sub structure for Piers, Piers hammer head bed blocks & Pedestals 5m to 10m

103

936270

9090

... More
Vibrated reinforced Cement Concrete in sub structure complete as per Drawing and Technical Specifications and as per MoRTH specification Nos.1500,1700 & 2200 excluding cost of reinforcement M-30 Sub structure Bearing pedastals

3

27213

9071

... More
Suplying ,fitting and fixing in position true to line and level elastomeric neoprene bearing confirming to IRC: 83 (Part -II ) ,section IX and Clause 2005 of MoRTH Specifications complete including all accessories as per drawing and Technical Specifications and MORTH (5th revision ) Spn.2000&2200 Bearing size 500x360x96mm

32

401920

12560

... More
Furnished and placing vibrated reinforced cement concrete in super structure as per drawing and Technical Specifications and MoRTH (5th revision) SPN.1500,1600,&1700 excluding cost of steel and its fabrication charges- T Beam Girder Slabs

480

4979040

10373

... More
Construction of precast RCC railing of M 30 grade , aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to center spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertiacal post for expansion, complete as per approved drawings and Technical Specifications as per MoRTH (5th revision) spn nos.2703,1500,1600,&1700 excluding cost of steel and its fabrication charges.

148

155548

1051

... More
Vibrated reinforced cement concrete M 40 grade using 20mm & 10mm hard broken graded granite crushed metal (SS-5) including cost, conveyance of all materials to site and labour charges, centering, machine mixing, laying, vibrating, curing etc., including other incidental hire and operational charges of all T&P and all water leads etc., complete as per approved drawings and as directed during execution but excluding cost of steel and its fabrication charges for finished item as per MoRT&H specification 809,1500,1700 & 2200 (5th revision ) and as directed by the Engineer-in-Charge for Crash barrier, excluding Reinforcement.

148

327968

2216

... More
PCC M15 grade levelling course below approach slab complete as per drawing and technical specifications no. 2700

9

63279

7031

... More
Vibrated Reinforced cement concrete approach slab excluding reinforcement complete as per SD/104., and as per MORT&H specification no.1500, 1600, 1700 & 2704.- VRCC M30-grade

20

163600

8180

... More
Providing and laying cement concrete wearingcoat M30 grade excluding reinforcement and fabrication charges complete as per drawing MOST Drg.No.SD.205 and as per technical MORT&H specification no.1500,1600,1700,2702

57

466374

8182

... More
Supplying ,fitting and placing uncoated HYSD bar reinforcement in foundation complete as per drawing and Technical Specifications as per MoRTH (5th revision) specification No. 1600. FOUNDATION

17

1574319

92607

... More
Supplying ,fitting and placing uncoated HYSD bar reinforcement in sub structure complete as per drawing and Technical Specifications as per MoRTH (5th revision) specification No. 1600.&2200 SUB STRUCTURE

20

1858560

92928

... More
Supplying ,fitting and placing uncoated HYSD bar reinforcement in super structure complete as per drawing and Technical Specifications as per MoRTH (5th revision) specification No. 1600. SUPER STRUCTURE

90

8561340

95126

... More
Providing Grouted Revetment with rough stone (HBG) of not less than 300 mm size grouted with 0.20 cum of CC (1:4:8) including cost, and conveyance of materials to site and including labour charges for packing the stones for revetment etc., complete for finished item of work as per MoRT&H specification 2504 ( 5th Revision) and as directed by the Engineer-in-Charge for quadrential revetment.

30

107340

3578

... More
Pitching with ss revetment 300 mm size rough stone including cost and conveyance of materials to site and including labour charges for packing the stones for revetment etc., complete for finished item of work as per MoRT&H specification 2504 ( 5th Revision ) and as directed by the Engineer-in-Charge for Pitching of slopes for Toe wall.

12

31716

2643

... More
Providing and laying filter material with Gravel underneath pitching in slopes including cost, and conveyance of materials to site including labour charges etc., complete for finished item of work as per MoRT&H Specification 2504 (5th Revision) and as directed by the Engineer-in-Charge under Revetment.

15

28725

1915

... More
Back filling behind Abutments with gravel including cost ,conveyance of all materials to site etc., complete as per Clause 710.1.4 of IRC : 78and as per MoRT&H Specification No. 2200 (5th Revision) and as per Drawing and technical specifications for finished item of work

111

166500

1500

... More
Providing and laying of filter media using 50% of 150 mm IRC soling stone and 50 % of 40 mm HBG metal satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to athickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind the abutment, wing wall and return wall to the full height compacted to a firm condition including cost and conveyance of all meterials ,and all labour charges as directed by the departmental officers as per drawing and Technical specifications as per clause 710.1.4 of IRC:78 and 2200 of MoRT&H (5th Revision) for finished item of work.

71

195250

2750

... More
Providing weep holes in VCC Abutments, Return walls and wing walls with 100mm Diameter AC/PVC pipe extending through the full width of the structure at 1.00m C/C in both horizontal and vertical direction so that the weep holes in each horizontal direction is staggered from the weep holes laying above and below lines as shown in drawing including cost and conveyance of the A.C/PVC pipes and labour charges for cutting to required length, placing the pipe with a slope of about 1V : 20H towards stream side face etc., complete for finished item of work for weep holes as per MoRT&H specification 2706 & 2200 (5th Revision)

114

33972

298

... More
Supplying and fixing of GI drainage spouts complete as per MoRT&H Specification No.2705

24

83568

3482

... More
Providing and laying of a Strip seal expansion Joint catering to maximum horizontal movement upto 70mm, complete as per drawing and standard specificxations to be installed by the manufacturer/ supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation

60

444240

7404



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.