Police Housing Corporation Limited Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Police Housing Corporation Limited - APSPHCL Tender
Residential Properties
Opening Date22 Feb 2021
Closing Date1 Mar 2021
Tender Amount₹ 5,83,767
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
₹ 5,000
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
377465Tender No
Short tender notice no. 24/2020-21/ Dt:22-02-2021Tender Authority
Police Housing Corporation Limited ViewPurchaser Address
-Website
http://tender.apeprocurement.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
CADD LAD;VIBRATED REINFORCED CEMENT CONCRETE M - 25 DESIGN MIX CORRESPONDING TO TABLE 9 OF IS 456 USING GRADED 20MM SIZE (SS 5 ) HARD GRANITE MACHINE CRUSHED GRADED METAL (COARSE AGGREGATE) FROM APPROVED QUARRY INCLUDING COST AND CONVEYANCE OF ALL MATERIALS LIKE CEMENT, FINE AGGREGATE (SAND), COARSE AGGREGATE, WATER ETC., TO SITE AND COST OF (EXCLUDING SEIGNIORAGE CHARGES( AND ALL OPERATIONAL , INCIDENTAL AND ALL OTHER TAXES ON ALL MATERIALS AND ALL LABOUR CHARGES FOR STEEL CENTERING ,SHUTTERING AND SCAFFIOLDING WITH PROVIDING CENTERING USING STEEL SCAFFOLDING PIPES, JACK PROPS, WALLETS, FOOT PLATES, BRACKETS,, WALL PLATES AND STEEL CENTRING PLATES ETC., AS PER THE APPROVED SHUTTERING PLAN AND OTHER ACCESSORIES AS PER NORMS AND STABILITY CALCULATIONS USING STAGING CROSS MEMBERS ETC., MACHINE MIXING WITH WEIGH BATCHER, LAYING CONCRETE, VIBRATING, LIFT CHARGES ,CURING ETC.,COMPLETE FOR BUT EXCLUDING COST OF STEEL AND ITS FABRICATION CHARGES FOR FINISHED ITEM OF WORK, FOR FIRST FLOOR SLABS OF 125 MM THICK(APSS NO. 402 & 403 )
4.5
-
41809.05
CADD LAD;VIBRATED REINFORCED CEMENT CONCRETE M - 25 DESIGN MIX CORRESPONDING TO TABLE 9 OF IS 456 USING GRADED 20MM SIZE (SS 5 ) HARD GRANITE MACHINE CRUSHED GRADED METAL (COARSE AGGREGATE) FROM APPROVED QUARRY INCLUDING COST AND CONVEYANCE OF ALL MATERIALS LIKE CEMENT, FINE AGGREGATE (SAND), COARSE AGGREGATE, WATER ETC., TO SITE AND COST OF (EXCLUDING SEIGNIORAGE CHARGES( AND ALL OPERATIONAL , INCIDENTAL AND ALL OTHER TAXES ON ALL MATERIALS AND ALL LABOUR CHARGES FOR STEEL CENTERING ,SHUTTERING AND SCAFFIOLDING WITH PROVIDING CENTERING USING STEEL SCAFFOLDING PIPES, JACK PROPS, WALLETS, FOOT PLATES, BRACKETS,, WALL PLATES AND STEEL CENTRING PLATES ETC., AS PER THE APPROVED SHUTTERING PLAN AND OTHER ACCESSORIES AS PER NORMS AND STABILITY CALCULATIONS USING STAGING CROSS MEMBERS ETC., MACHINE MIXING WITH WEIGH BATCHER, LAYING CONCRETE, VIBRATING, LIFT CHARGES ,CURING ETC.,COMPLETE FOR BUT EXCLUDING COST OF STEEL AND ITS FABRICATION CHARGES FOR FINISHED ITEM OF WORK, FOR FIRST FLOOR BEAMS(APSS NO. 402 & 403 )
1.7
-
16505.13
CADD LAD;VIBRATED REINFORCED CEMENT CONCRETE M - 25 DESIGN MIX CORRESPONDING TO TABLE 9 OF IS 456 USING GRADED 20MM SIZE (SS 5 ) HARD GRANITE MACHINE CRUSHED GRADED METAL (COARSE AGGREGATE) FROM APPROVED QUARRY INCLUDING COST AND CONVEYANCE OF ALL MATERIALS LIKE CEMENT, FINE AGGREGATE (SAND), COARSE AGGREGATE, WATER ETC., TO SITE AND COST OF (EXCLUDING SEIGNIORAGE CHARGES( AND ALL OPERATIONAL , INCIDENTAL AND ALL OTHER TAXES ON ALL MATERIALS AND ALL LABOUR CHARGES FOR STEEL CENTERING ,SHUTTERING AND SCAFFIOLDING WITH PROVIDING CENTERING USING STEEL SCAFFOLDING PIPES, JACK PROPS, WALLETS, FOOT PLATES, BRACKETS,, WALL PLATES AND STEEL CENTRING PLATES ETC., AS PER THE APPROVED SHUTTERING PLAN AND OTHER ACCESSORIES AS PER NORMS AND STABILITY CALCULATIONS USING STAGING CROSS MEMBERS ETC., MACHINE MIXING WITH WEIGH BATCHER, LAYING CONCRETE, VIBRATING, LIFT CHARGES ,CURING ETC.,COMPLETE FOR BUT EXCLUDING COST OF STEEL AND ITS FABRICATION CHARGES FOR FINISHED ITEM OF WORK, FOR FIRST FLOOR LINTEL(APSS NO. 402 & 403 )
0.8
-
8232.96
CADD LAD;VRCC M-20 GRAD EDESIGN MIX CORRESPONDING TO TABLE 9 OF IS 456 USING 20MM SIZE GRADED MACHINE CRUSHED HARD GRANITE METAL, INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, (Excluding Seigniorage Charges), , ON ALL MATERIALS, ALL INCIDENTAL, OPERATIONAL AND LABOUR CHARGES SUCH AS MACHINE MIXING, LAYING CONCRETE, VIBRATING, CURING ETC., COMPLETE AND PROVIDING CENTERING USING STEEL SCAFFOLDING PIPES, JACK PROPS, STEEL CENTERING PLATES ETC., FOR UNSUPPORTED HIEGHT OF 3.66M BUT EXCLUDING COST OF STEEL AND ITS FABRICATION CHARGES FOR FINISHED ITEM OF WORK. SUNSHADES OF 50MM (2") AVERAGE THICK INCLUDING DRIP COURSE OF SIZE 40MM WIDE X 20MM HEIGHT IN CEMENT MORTAR (1:4)PROP - FIRST FLOOR (APSS NO.403)
2.5
-
2329.5
CADD LAD;SUPPLY AND PLACING OF THEDESIGN MIX CONCRETE OF M-25 GRADE CORRESPONDING TO IS 456 USING WEIGH BATCHER/MIXER WITH 20MM SIZE GRADED MACHINE CRUSHED HARD GRANITE METAL FROM APPROVED QUARRY INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, (Excluding Seigniorage Charges) CHARGES, ALL OPERATIONAL, INCIDENTAL AND LABOUR CHARGES SUCH AS WEIGH BATCHING, MACHINE MIXING, LAYING CONCRETE, CURING ETC., COMPLETE WITH MINIMUM CEMENT CONTENT AS PER IS CODE, ETC., COMPLETE BUT EXCLUDING COST OF STEEL AND ITS FABRICATION CHARGES FOR FINISHED ITEM OF WORK. RACKS 38 MM THICK - FIRST FLOOR. (APSS NO.403)
4
-
1250.4
CADD LAD;PLAIN CEMENT CONCRETE (1:3:6) PROP. USING 20MM GRADED HARD GRANITE MACHINE CRUSHED METAL INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, (Excluding Seigniorage Charges), CENTERING USING STEEL SCAFFOLDING PIPES, JACK PROPS, STEEL CENTERING PLATES ETC.,, MACHINE MIXING, LAYING, CURING, FINISHING, ALL OTHER INCIDENTAL, OPERATIONAL, LABOUR CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK. BED BLOCKS IN FIRST FLOOR (APSS NO: 402).
0.3
-
1381.17
CADD LAD;PROVIDING IMPERVIOUS COAT TO EXPOSED RCC ROOF SLAB SURFACE IN CM(1:3), 20MM THICK WITH 1KG OF WATER PROOF COMPOUND PER BAG OF CEMENT LAID OVER ROOF WHEN IT IS GREEN, INCLUDING COST OF ALL MATERIALS, (Excluding Seigniorage Charges) CHARGES, COST & CONVEYANCE OF ALL MATERIALS, INCIDENTAL, OERATIONAL AND LABOUR CHARGES FOR MIXING MORTAR, LAYING, RENDERING SMOOTH AND THREAD LINING, CURING, ROUNDING OFF JUNCTIONS OF WALL AND SLAB ETC,, COMPLETE FOR FINISHED ITEM OF WORK. FIRST FLOOR (APSS.NO: 901&903)
35
-
10524.5
CADD LAD;PLASTERING TO SUPERSTRUCTURE 12 MM THICK IN TWO COATS, WITH A BASE COAT OF 8 MM THICK IN CM (1:6) PROP. AND TOP COAT OF 4 MM THICK IN CM (1:4) PROP. WITH DUBARA SPONGE FINISHING, INCLUDING MAKING GROOVES, COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES, SCAFFOLDING, CURING, ALL OTHER INCIDENTAL AND OPERATIONAL CHARGES ETC., COMPLETE.FOR FINISHED ITEM OF WORK. (Excluding Seigniorage Charges)FIRST FLOOR (APSS NO: 901&904)
250
-
65500
CADD LAD;ORNAMENTAL PLASTERING TO CEILING 12MM THICK WITH A BASE COAT OF 8 MM THICK IN CM (1:5) PROP. AND FINISH COAT OF 4MM THICK IN CM (1:3) PROP. WITH DUBARA SPONGE FINISHING, INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES, SCAFFOLDING, CURING, ALL OTHER INCIDENTAL AND OPERATIONAL CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK. FIRST FLOOR (Excluding Seigniorage Charges) (APSS NO: 901 & 904)
35
-
9677.5
CADD LAD;FLOORING WITH CERAMIC TILES 7.3 MM THICK, SET OVER BASE COAT OF CEMENT MORTAR (1:8), 12 MM THICK OVER CC BED ALREADY LAID OR RCC ROOF SLAB, INCLUDING NEAT CEMENT SLURRY OF HONEY LIKE CONSISTENCY SPREAD @ 3.3.KGS PER SQM & JOINTED NEATLY WITH WHITE CEMENT PASTE TO FULL DEPTH MIXED WITH PIGMENT OF MATCHING SHADE, INCLUDING COST OF ALL MATERIALS LIKE CEMENT, SAND WATER AND TILES ETC., COMPLETE, INCLUDING SEIGNIORAGE CHARGES, ETC., COMPLETE FOR FINISHED ITEM OF WORK,FIRST FLOOR .
2
-
1716.2
CADD LAD;FLOORING WITH DOUBLE CHARGED / MULTI CHARGED STAIN FREE FULL BODY PORCELAIN VITRIFIED TILES WITH DOUBLE LAYER PIGMENT OF SIZE 600 X 600 MM AND THICKNESS BETWEEN 8-10 MM 1ST QUALITY CONFORMING TO IS:13711, IS:13712, IS:13630 (PARTS 1 TO 15) OF ANY COLOUR AND FINISH IN ALL SHADES AND DESIGNS AS DIRECTED BY THE ENGINEER-IN-CHARGE, SET OVER BASE COAT OF CEMENT MORTAR (1:8), 12 MM THICK OVER CC BED ALREADY LAID OR RCC ROOF SLAB, INCLUDING NEAT CEMENT SLURRY OF HONEY LIKE CONSISTENCY SPREAD @ 3.3.KGS PER SQM & JOINTED NEATLY WITH WHITE CEMENT PASTE TO FULL DEPTH MIXED WITH PIGMENT OF MATCHING SHADE, INCLUDING COST OF ALL MATERIALS LIKE CEMENT, SAND WATER AND TILES ETC., COMPLETE, INCLUDING (Excluding Seigniorage Charges) CHARGES, ETC., COMPLETE FOR FINISHED ITEM OF WORK - FIRST FLOOR.
17
-
19184.5
CADD LAD;PROVIDING SKIRTING TO INTERNAL WALLS WITH DOUBLE CHARGED / MULTI CHARGED STAIN FREE FULL BODY PORCELAIN VITRIFIED TILES WITH DOUBLE LAYER PIGMENT OF SIZE 600 X 600 MM AND THICKNESS BETWEEN 8-10 MM 1ST QUALITY CONFORMING TO IS:13711, IS:13712, IS:13630 (PARTS 1 TO 15) OF ANY COLOUR AND FINISH IN ALL SHADES AND DESIGNS AS DIRECTED BY THE ENGINEER-IN-CHARGE IN LENGTH EQUAL TO FLOORING STONES, SET OVER BASE COAT OF CM (1:5) 12 MM THICK WITH CEMENT SLURRY OF HONEY LIKE CONSISTENCY SPREAD AT THE RATE OF 3.30 KGS PER SQM AND JOINTED WITH WHITE CEMENT PASTE MIXED WITH PIGMENT OF MATCHING SHADE TO FULL DEPTH, INCLUDING COST OF ALL MATERIALS LIKE TILES, CEMENT, SAND AND WATER ETC., COMPLETE INCLUDING (Excluding Seigniorage Charges) CHARGES, ETC., COMPLETE FOR FINISHED ITEM OF WORK - FIRST FLOOR.
3
-
3405.9
CADD LAD;Dadooing to internal walls with colour glazed ceramic wall tiles of size 200 x 300 mm / 245 mm x 325 mm and thickness 6 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete including (Excluding Seigniorage Charges), etc., complete for finished item of work,FOR FIRST FLOOR
11
-
5819
CADD LAD;INTRNAL DOOR (SINGLE SHITTER): 1.05X 2.10M: SUPPLYING, POSITIONING AND FIXING OF ISI MARK, STANDARD MAKE, FLUSH DOOR SHUTTER OF 35 MM THICK BOND WOOD SOLID BLOCK BOARD TYPE WITH TEAK PLY ON ONE FACE AND COMMERCIAL PLY ON ANOTHER FACE, INCLUDING DOOR FRAME MADE WITH TEAK WOOD SCANTLING OF SIZE 100 MM X 75 MM, 6 NOS. OF MS 'Z' HOLD FASTS OF SIZE 230 X 40 X 3 MM, 4 NOS. OF 125 MM BUTT HINGES, 2 NOS. 150 MM LONG DOOR HANDLES, 1 NO. ALDROP OF SIZE 300 MM LONG, 2 NOS. 250 MM LONG TOWER BOLTS, 1 NO. DOOR STOPPER WITH BOLTS, NUTS, NF SCREWS, COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES FOR MAKING THE FRAME, SHUTTER, MINOR EXTRA FIXTURES REQUIRED IF ANY AS DIRECTED BY THE ENGINEER-IN-CHRGE OF THE WORK COMPLETE FOR FINISHED ITEM OF WORK. (ALL FITTINGS AND FIXTURES SHOULD BE OF ALUMINIUM, ISI MARK, GOT APPROVED BY THE ENGINEER-IN-CHARGE). (APSS NO: 1001&1002).
2.3
-
11738.74
CADD LAD;PVC TOILET DOOR OF SIZE 0.85 X 2.10 M: S&F OF (A) DOOR FRAME MADE OUT OF PVC MATERIAL CONFORMING TO IS:10151:1982. THE DOOR FRAME SHALL BE MADE FROM EXTRUDED PVC SECTION IN OVERALL DIMENSIONS OF 40 X 48 MM HAVING WALL THICKNESS OF 1.1MM +/-0.3MM WITH USUAL PROCESS VARIATION CORRESPONDING TO SINTEX CODE NUMBER RUPS 414. THE FRAME SHALL BE REINFORCED WITH SPECIAL POLYMERIC REINFORCEMENT AS SHOWN IN DRAWING TO TAKE UP NECESSARY HARDWARE. THE CORNER JOINT SHALL BE MITRE CUT AND WELDED OR JOINED BY MEANS OF CONCEALED CLEATS WITH NECESSARY SCREWS FITTINGS. A TIE ROD TO BE PROVIDED AT BOTTOM. [LAMINATED PROFILE] (B) THE SHUTTER FRAME MADE OUT OF PVC EXTRUDE SECTION HAVING OVERALL DIMENSIONS OF 59 X 24 MM WITH WALL THICKNESS OF 1.0MM +/-0.3MM WITH USUAL PROCESS VARIATION CORRESPONDING TO THE SINTEX CODE NO.DWUF-302. THE SHUTTER FRAME IS GIVEN TAPERED SHAPE TO PROVIDE BETTER GRIP TO THE INFILL PANEL AND TO DRAIN OUT THE WATER. THE INFILL PANEL IS MADE OUT OF SEAMLESS ONE PIECE MULTI CHAMBERED PVC EXTRUDED SECTION HAVING OVERALL DIMENSION OF 610 X 20 MM WITH WALL THICKNESS OF 1MM +/-0.2MM WITH USUAL PROCESS VARIATION CORRESPONDING TO THE SINTEX CODE NO.SPUF-128. THE SHUTTER FRAME SHALL BE MITRE CUT AND JOINED AT THE CORNER POLYMERIC ?L? TYPE CORNERS SHALL BE PROVIDED AT THE CORNERS TO TAKE UP HARDWARE & FIXTURES AND SHALL BE FIXED WITH 19 X 8MM COUNTER SUNK-FULLY THREADED PARALLEL SHANK STEEL SCREWS. ALL THE HARDWARE LOCATIONS SHALL BE REINFORCED WITH SPECIAL POLYMERIC BARS.THE DOOR FRAME SHALL BE FIXED TO THE WALLBY USING 80 MM LONG SCREWS THROUGH THE FRAME WITH THE HELP OF PVC FASTENERS. HARDWARE MADE OUT OF STEEL COATED BUTTERFLY HINGES - 3 NOS. FOR EACH SHUTTER AND ISI MAKE HANDLES, TOWER BOLTS, ALDROPS SHALL BE PROVIDED AS DIRECTED BY THE ENGINEER-IN-CHARGE FOR THE FINISHED ITEM OF WORK.
2
-
4823.2
CADD LAD;SUPPLYING AND FIXING OF UNPLASTICISED POLY VINYL CHLORIDE (UPVC) 3 TRACK SLIDING WINDOWS WITH MESH SHUTTER ? (2-GLASS SHUTTERS AND 1-MESH SHUTTER) DULY MANUFACTURED USING UPVC REINFORCED PROFILES (COMPOSITION OF PROFILE SHALL CONSISTS A MINIMUM OF 5.5 PHR OF TIO2 AND NOT MORE THAN 12 PHR OF CACO3 FOR EVERY 100 PARTS OF PVC RESIN) OF (94 MM X 45 MM)/(80 MM X 52 MM) X 2.20 MM FOR OUTER FRAMES, (58 MM X 39 MM)/(54 MM X 38 MM) X 2.20 MM FOR SLIDING SHUTTER FRAMES CAPABLE OF MOUNTING SINGLE GLAZING SYSTEMSTRUCTURALLY REINFORCED WITH HOT DIP GALVANIZED UP TO 50 MICRONS OF MINIMUM THICKNESS OF 1.0/1.2 MM PREFABRICATED & WELDED THROUGH FUSION WELDING. THE WINDOW SASH SHALL BE FITTED WITH 5 MM THICK CLEAR FLOAT GLASS OF REPUTED MAKE AND MESH SHUTTER FRAME SHALL BE (42 MM X 25 MM)/(52 MM X 21.5 MM) X 2.0 MM FITTED WITH VINYL COATED FIBER MESH- ON ROLLERS/ PULLEY DULY FIXED WITH GREY COLOUR TPV GASKET FOR SASH &GLAZING BEAD SHALL BE CO-EXTRUDED WITH GREY COLOUR SOFT PVC.SYSTEM SHALL HAVE SINGLE POINT LOCKING WITH TOUCH LOCK AND THE SYSTEM IS TO BE INSTALLED AT THE SITE USING ANCHOR FASTENERS, SILICON RUBBER SEALANT, EASY GLAZING/ DEGLAZING AT SITE ETC., INCLUDING COST AND CONVEYANCE OF ALL MATERIALS, ACCESSORIES, LABOUR CHARGES FOR TRANSPORTATION, ERECTION AT SITE COMPLETE FOR FINISHED ITEM OF WORK.(BMT-P.72)
5
-
32972.5
CADD LAD;S & F OF FIXED LOUVERED VENTILATOR MADE OUT OF MULTI CHAMBERED UPVC SECTIONS WITH TPV GASKETS HAVING ISOLATED DRAINAGE AND REINFORCED WITH GALVANIZED IRON PROFILES THROUGHOUT THE WINDOW. THE OUTER FRAME HAVING AN OVERALL SIZE OF 60 X 55 MM WITH REINFORCEMENT OF 1 MM THICKNESS AND MULLION WITH OVERALL SIZE OF 74 X 60 MM WITH REINFORCEMENT OF 1 MM THICKNESS. VENTILATOR SHALL BE PROVIDED WITH 4.5 MM PIN HEAD GLASS, STANDARD HARDWARE. WALL THICKNESS OF FRAME & MULLION SHALL BE 2.0 MM, INCLUDING COST AND CONVEYANCEOF ALL MATERIALS, ACCESSORIES, LABOUR CHARGES FOR TRANSPORTATION,ERECTION AT SITE WITH TEMPLATES FOR CASEMENT SIZING COMPLETE FOR FINISHED ITEM OF WORK.
0.7
-
4203.43
CADD LAD;SUPPLYING AND FIXING MS GRILLS FOR WINDOWS/VENTILATORS OF ALL SIZES AS DIRECTED BY THE ENGINEER-IN- CHARGE INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE AND LABOUR CHARGES FOR FABRICATION, FIXING ETC., COMPLETE FOR THE FINISHED ITEM OF WORK M.S.SQUARE BARS OF ALL SIZES
70
-
5782
CADD LAD;SUPPLYING AND FIXING MS GRILLS FOR WINDOWS/VENTILATORS OF ALL SIZES AS DIRECTED BY THE ENGINEER-IN- CHARGE INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE AND LABOUR CHARGES FOR FABRICATION, FIXING ETC., COMPLETE FOR THE FINISHED ITEM OF WORK M.S.FLATS OF ALL SIZES
20
-
1674
CADD LAD;Painting to new walls with 2 coats of Plastic emulsion paint of approved brand and shade over a base coat of appropriate primer of approved brand, making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 911 for internal walls
145
-
17472.5
CADD LAD;Painting with Exterior Emulsion Paint of approved make (ACE from Asian Paint) and colour to the Exterior Faces of walls as directed 2 coats by diluting 1 lit. of Emulsion Paint with a maximum 750 ml of water within an interval of not less than 6 hours between two coats over 1 coat of Exterior Wall Primer by diluting 1 Lit. of primer with 1 Lit. of water (Total 3 coats) with surface preparation etc., as per standard specification including cost and conveyance of all materials, brushes, labour charges, curing, scaffolding and all other incidental and operational charges etc., complete for finished item of work in all floors.
90
-
15345
CADD LAD;PAINTING TO NEW IRON WORK TWO COATS WITH SYNTHETIC ENAMEL PAINT OF APPROVED BRAND AND SHADE OVER ONE COAT OF RED OXIDE PRIMER COAT (TOTAL 3 COATS) INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, ALL INCIDENTAL, OPERATIONAL & LABOUR CHARGES FOR PREPARING AND CLEANING THE SURFACE OF DIRT WITH SOAP AND BRUSHES, INCLUDING PUTTY, ETC., COMPLETE FOR FINISHED ITEM OF WORK. (APSS NO.1201, 1207, 1212).
5
-
732.5
CADD LAD;PROVIDING "HYSD" STEEL BARS OF DIFFERENT DIAMETERS BELOW 36MM DIAMETER (Fe - 500 GRADE AS PER IS 1786 - 1979)FOR REINFORCEMENT INCLUDING CUTTING, BENDING TO REQUIRED SIZES AND SHAPES, PLACING THEM IN POSITION WITH COVER BLOCKS OF APPROVED SHAPE AND SIZE, TYING FIRMLY WITH M.S BINDING WIRE OF SWG, FORMING GRILLS FOR REINFORCEMENT WORKS AS PER APPROVED DESIGNS AND DRAWINGS TO BE SUPPLIED AT THE TIME OF EXECUTION OF WORK INCLUDING COST AND CONVEYANCE OF DEFORMED BARS, BINDING WIRE, COVER BLOCKS AND ALL WASTAGES SUCH AS OVER LAPS, COUPLINGS, WELDED JOINTS, CHAIRS, SPACE BARS ETC., AS DIRECTED BY THE ENGINEER-IN-CHARGE AND ALL OPERATIONAL, INCIDENTAL LABOUR CHARGES SUCH AS CUTTING, BENDING, PLACING IN POSITION, TYING ETC., COMPLETE FOR FINISHED ITEM OF WORK FOR ALL LENGTHS AS PER DRAWINGS AND TECHNICAL SPECIFICATIONS FOR BARS BELOW 36MM DIA WHERE THEY ARE NOT WELDED.
1.59
-
94258.86
CADD LAD;PROVIDING AND APPLYING SYNTHETIC PLASTER PUTTY OR EQUIVALENT PUTTY SUCH AS BIRLA WALL CARE PUTTY OF AVERAGE 1 TO 2 MM THICK OVER PLASTERED SURFACE TO PREPARE THE SURFACE EVEN AND SMOOTH AFTER THOROUGHLY BRUSHING THE SURFACE TO REMOVE ALL DIRT AND REMAINS OF LOOSE POWDERED MATERIALS, APPLYING EMERY PAPER, SAND THE SURFACE, CLEAN & WIPE OFF LOOSE DUST, APPLYING, KNIFING PASTE FILLER BY PUTTY KNIFE / MUSLIN PAD, AIR DRY FOR 2-3 HRS., SAND WITH 180 AND 320 NO. EMERY PAPER FOR THE SURFACE PREPARATION INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, ALL OPERATIONAL, INCIDENTAL, LABOUR CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK FOR INTERNAL WALLS.
121
-
19493.1
CADD LAD;Flooring with high polished granite 18 mm thick slabs Black set over base coat of cement mortar (1:8), 20 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like cement, sand water and tilesetc., complete, including (Excluding Seigniorage Charges), labour charges for dressing of tilesetc., complete for finished item of work, but excluding the cost of conveyance of all materials for GROUND FLOOR-PLATFORM
4
-
11682
CADD LAD;Supply and Fixing Gyp Board Suspended regular single layer false ceiling (GS-MFSC-4.1 as per India Gypsum) using 12.50 mm thick Gyp Board conforming to IS 2095-1982 fixing to Gyp steel GI perimeter channels of size 20 x 27 x 30 mm (web) of 0.55 mm thick along the perimeter of ceiling screw fixed to brick work / partition at 610 mm c/c and suspending the frame work using Intermediate channels (45 x 15 x 15 x 0.90 mm) from soffit at 1220 mm c/c with ceiling angle (25 x 10 x 0.55 mm) fixed with GI Cleat and steel expansion fasteners & connecting clip to the ceiling channels (with knurled web of 51.50 x 26 x 10.50 x 0.55 mm) fixed in diection perpendicular to the intermediate channel at 457 mm c/c and fixing the 12.50 mm drywall scews at 230 mm c/c & jointing, fixing using joint compound and paper tape to have a flush look including filling the tappered & square edges with jointing compound, two coats of drywall topcoat complete for finished item of work as per India Gypsum Ltd., Specification.
17
-
14390.5
CADD LAD;SUPPLYING AND FIXING 76.2 MM (3") DIA UV RESISTANT UPVC SWR NAHANI TRAP WITH JALI OF APPROVED ISI BRAND INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC., COMPLETE FOR FINISHED ITEM OF WORK.
1
-
94.6
CADD LAD;SUPPLY AND LAYING OF ASHIRVAD / AJAY / ASTRAL FLOW GUARD OR EQUIVALENT CPVC PIPES AND FITTINGS TO MEET THE REQUIREMENT OF ASTM-D 2846 AND ARE PRODUCED IN CTS (COPPER TUBE SIZES 1/2" TO 2") ASHIRWAD FLOWGUARD SDR 13.5 PIPES ARE MADE FROM IDENTICAL CPVC COMPOUNDS HAVING THE SAME PHYSICAL PROPERTIES FOR HOT AND COLD WATER (IS 15778-2007) - 15.90 MM OD PIPES SDR 13.5
15
-
874.5
CADD LAD;SUPPLYING AND LAYING 75 MM DIA SINGLE SOCKET PVC / SWR PIPES OF APPROVED MAKE OF 4 Kg/cm2 CONFIRMING TO IS:13592-1992, WITH NECESSARY UPVC PIPE CLIPS @ 5' INTERVALS AND LABOUR CHARGES FOR LAYING, FIXING, AND COMMISSIONING THE PVC PIPES INCLUDING COUPLERS/ BENDS/TEES ETC., INCLUDING FIXING NECCESSARY FITTINGS LIKE BENDS, PLUGS, COUPLERS, JUNCTIONS, TEES ETC., WITH SOLVENT JOINTING AS PER STANDARDS INCLUDING CUTTING OF WALLS AND FLOORS AND MAKING THE SAME GOOD, INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK.
10
-
1761
CADD LAD;SUPPLY AND FIXING IN POSITION EUROPEAN TYPE WATER CLOSET OF BEST INDIAN MAKE WHITE GLAZED WITH 100 MM 'P' TRAP, PLASTIC SEAT AND LID FOR EUROPEAN WATER CLOSET AND BUFFERS AS PER IS 2548-1963 AND PROVIDING PVC LOW LEVEL FLUSHING SYSTEM OF 8 LITRES CAPACITYOF PARRYWARE SLIMLINE (WHITE) WITH INTERNAL COMPONENTS AND SHORT BEND, 12.70 MM PVC CONNECTION WITH BRASS UNION NUTS C.P COATED, INCLUDING CUTTING THE WALLS AND FLOORS AND MAKING GOOD THE SAME, COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES ETC., COMPLETE.
1
-
3679.5
CADD LAD;SUPPLYING AND FIXING 12.7mm DIA CP LONG BODY BIB COCK FANCY TYPE DELUXE INDIAN MAKE SEIKO /SENIOR/NICE OR EQUIVALENT INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE AND LABOUR CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK .
3
-
1805.1
CADD LAD;SUPPLYING AND FIXING 12.70 MM DIA ANGLE STOP COCK (400 GRAMS)INDIAN MAKE, HEAVY DUTY OF APPROVED ISI BRAND INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC., COMPLETE FOR FINISHED ITEM OF WORK.
1
-
448.8
CADD LAD;SUPPLYING AND FIXING 24" LONG 3/4 " MM DIA, C.P TOWEL ROD WITH BRACKETS AND SCREWS INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES ETC., FOR FINISHED ITEM OF WORK COMPLETE. (BMW-I.132)
1
-
143
CADD LAD;SUPPLYING, LAYING, JOINTING AND TESTING OF SINGLE SOCKET 110 MM DIA PVC / SWR PIPES OF APPROVED MAKE OF 4 Kg/cm2 CONFIRMING TO IS:13592-1992, AND LABOUR CHARGES FOR LAYING, FIXING, AND COMMISSIONING THE PVC PIPES INCLUDING COUPLERS/ BENDS/TEES ETC., INCLUDING FIXING NECCESSARY FITTINGS LIKE BENDS PLUGS, COUPLERS, JUNCTIONS, TEES ETC., WITH SOLVENT JOINTING AS PER STANDARDS INCLUDING EXCAVATION OF TRENCHES AND SOCKET PITS IN ANY SOIL (EXCEPT ROCK REQUIRING BLASTING) UP TO 0.91M DEPTH AND REFILLING WITH EXCAVATED SOILS, WATERING, TAMPING, COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK.
15
-
6826.5
CADD LAD;SUPPLYING AND LAYING 110 MM DIA PVC / SWR PIPES OF APPROVED MAKE OF 4 Kg/cm2 CONFIRMING TO IS:13592-1992, WITH NECESSARY UPVC PIPE CLIPS @ 5' INTERVALS AND JOINTED WITH SOLVENT CEMENT INCLUDING CUTTING OF WALLS AND FLOORS AND MAKING THE SAME GOOD, COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES ETC., COMPLETE FOR FINISHED ITEM OF WORK
10
-
2495
CADD LAD;SUPPLYING AND FIXING 110 MM DIA UV RESISTANT UPVC SWR DOOR TEE AS PER ISI STANDARDS INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC., COMPLETE FOR FINISHED ITEM OF WORK.
2
-
200.2
CADD LAD;SUPPLYING AND FIXING 110 MM DIA UV RESISTANT UPVC SWR COWL AS PER ISI STANDARDS INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC., COMPLETE FOR FINISHED ITEM OF WORK.
2
-
35.2
CADD LAD;SUPPLYING AND FIXING 110 MM DIA UV RESISTANT UPVC SWR single 'Y' Bend AS PER ISI STANDARDS INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC., COMPLETE FOR FINISHED ITEM OF WORK.
1
-
167.2
CADD LAD;SUPPLYING AND FIXING BEST INDIAN MAKE 609.6X457.2mm T.V SHAPE MIRROR WITH PLASTIC FRAME MIRROR INCLUDING WOODEN BLOCKS, SCREWS ETC., INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR CHARGES ETC., FOR FINISHED ITEM OF WORK COMPLETE.
1
-
497.2
CADD LAD;SUPPLY AND LAYING OF ASHIRVAD / AJAY / ASTRAL FLOW GUARD OR EQUIVALENT CPVC PIPES AND FITTINGS TO MEET THE REQUIREMENT OF ASTM-D 2846 AND ARE PRODUCED IN CTS (COPPER TUBE SIZES 1/2" TO 2") ASHIRWAD FLOWGUARD SDR 13.5 PIPES ARE MADE FROM IDENTICAL CPVC COMPOUNDS HAVING THE SAME PHYSICAL PROPERTIES FOR HOT AND COLD WATER (IS 15778-2007) - 28.60 MM OD PIPES SDR 13.5
30
-
4059
CADD LAD;SUPPLYING AND FIXING 25 MM NB SIZE GM GATE(PEET) VALVE AS PER IS - 778, CLASS-I, INDIAN MAKE HEAVY TYPE, INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC., COMPLETE FOR FINISHED ITEM OF WORK.
2
-
2312.2
CADD LAD;PROVIDING AND PLACING ON TERRACE POLYTHELENE WATER STORAGE TANKS (AT ALL FLOOR LEVELS) DOUBLE LAYER APPROVED BRAND CONFORMING TO IS12701-1996 AND MNUFACTURE WITH COVER AND SUITABLE LOCKING ARRANGEMENTS MAKING NECESSARY HOLES FOR INLET & OUTLETS AND OVERFLOW PIPES BUT WITHOUT FITTINGS & BASE SUPPORT FOR TANKS, MAKING GOOD THE SAME TO ENSURE LEAK PROOF WITH AN APPROPRIATE MASONARY PLATFORM INCLUDING COST AND CONVEYANCE OF ALL MATERIALS TO SITE, LABOUR ETC.,COMPLETE FOR FINISHED ITEM OF WORK AS DIRECTED BY THE ENGINEER -IN- CHARGE
1000
-
5500
CADD LAD;Supply and Fixing of 25mm outer dia heavy (2.20mm thickness) grade with IS:9537 part 3 regid PVC pipe (ISI mark) of makes concealed in wall with all required accessories including masonary work and labour charges etc., complete. (For circuit mains, power sockets and computer boards only) (Makes: Sudhakar/VIP/GM
20
-
1836
CADD LAD;Supply and Fixing of 25mm outer dia heavy (2.20mm thickness) grade with IS:9537 part 3 regid PVC pipe (ISI mark) of concealed in Roof Slabs with all required accessories including masonary work and labour charges etc., complete. (Makes: Sudhakar/VIP/GM
20
-
1484
CADD LAD;Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant low smoke FRLS / HFFR PVC insulated 1100V grade as perIS:694/1990 specification flexible copper cable in existing pipe with 6A one way modular switch with 6 modular cover frame, 3 plate Ceiling rose including all labour charges etc., complete for light, bell, fan and exhaust fan points in Non Residential Buildings. Wire Make: (Finolex/RR kabel/Havells) Ceiling rose: Anchor/ Gold Medal Olive /Million Zoom. Switches & Cover frame Make:Legrand Arteor/Carbtree Murano/GM-Zenova
15
-
8520
CADD LAD;Supply and fixing of 6/10A 3/2 pin modular plug socket - 2Nos with 6/10A one way modular switch -2Nos control on a common switch board covered with 6 module cover frame including earth con and including wire leads, earth connections along with all labour charges etc., complete. Make: Legrand Arteor/Carbtree Murano/GM-Zenov.
5
-
3465
CADD LAD;Supply and Fixing of 16/20A Modular 1 way combi Socket with shutter and 16A / 20A 1 Way Modular Switch duly recessed in wall with 3 Modular Box and 3 modular cover frame including earth connections and all labour charges etc., complete. Make: Legrand Arteor/Carbtree Murano/GM-Zenova/
3
-
2004
CADD LAD;Supply and fixing of batten holder / slanting holder in lieu of ceiling rose of light point complete with all connections and all labour charges with 7W LED, 490Lumens bulb (for new installation). Holder Make: Anchor / Gold Medal Olive / Million Zoom LAMP Make:Phillips / OSRAM / GE / Crompton.
3
-
771
CADD LAD;Supply and run of 1 of 14 /0.3mm (1.0 Sq.mm) FRLS / HFFR/ZHFR P.V.C. insulated 1100V grade as perIS:694/1990 specification for insulated flexible copper cable in existing pipe for earth continuity including all labour charges etc., complete. [for Earth lead to circuit mains, power sockets]. Make: Finolex/RR kabel/Havells
50
-
1050
CADD LAD;Supply and run of 2 of 36 /0.3mm (2.5 Sq.mm) FRLS / HFFR/ZHFR P.V.C. insulated 1100V grade as perIS:694/1990 specification for insulated flexible copper cable in existing pipe for run of circuits, power plugs & computer boards including all labour charges etc., complete. Make:Finolex/RR kabel/Havells
25
-
1825
CADD LAD;Supply and run of 2 of 56/0.3mm (4 Sq.mm) FRLS / HFFR/ZHFR PVC insulated 1100V grade as perIS:694/1990 specification for copper cable in existing pipe for mains inlcuding all labour charges etc., complete.[from Distribution boards to A/C points and mains to LDB]. Make:Finolex/RR kabel/Havells
30
-
3327
CADD LAD;Supply and run of 1 of 36 /0.3mm (2.5 Sq.mm) FRLS / HFFR/ZHFR P.V.C. insulated 1100V grade as perIS:694/1990 specification for insulated flexible copper cable in existing pipe for earth continuity including all labour charges etc., complete. [for Earth lead to A/C points and Distribution boards]. Make:Finolex/RR kabel/Havells
20
-
732
CADD LAD;Supply of 48" (1200mm) Sweep 5 Star rated Ceiling Fan, with double ball bearings without Regulatorincluding cost and conveyance of all materials and labour charges etc., complete. Makes: Crompton HS Decora / Havells ES Plus / Orient summer crown
2
-
5110
CADD LAD;Supply of 400w stepped type electronic regulator including cost and conveyance of materials and labour charges etc., complete. Make: Legrand Arteor/Carbtree Murano/GM-Zenov.
2
-
792
CADD LAD;Labour charges for fixing of ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.
2
-
360
CADD LAD;Supply of 40W Patty type tube light luminaire powder coated CRCA sheet steel housing with Copper Chokes and all standard accessories with 40W CFL Tube light including all material etc complete. Makes: Crompton / Bajaj / Surya / Havells / HPL
6
-
1749
CADD LAD;Fixing of 40W tube light luminaire on wall / Ceiling with all accessories including giving connections and all labour charges etc., complete.
6
-
864
CADD LAD;Supply of fresh air exhaust fan of light duty 250V A.C.50Hz../ 300mm size (12") 1350 R.P.M Metallic body plastic blades, wire mesh, etc., complete. complete.Make Crompton/Orient.
1
-
1361
CADD LAD;Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete.
1
-
528
CADD LAD;Supply of 40 W fluorescent street light luminaire with sheet alluminium housing and UV stabilised acrylic cover with Electronic ballast and all standard accessories etc. Makes: Wipro / G.E. / Phillips / Crompton.
1
-
1309
CADD LAD;Fixing of 40W street light luminary with 1.0 Mtr., 25mm dia GI pipe bracket and anti tilting MS flat etc., including giving connections and labour charges etc., complete.
1
-
571