To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Panchayat Raj Engineering Department Tender
Civil And Construction
Opening Date21 Mar 2025
Closing Date7 Apr 2025
Tender Amount₹ 29,69,949
Costs
EMD
₹ 29,699Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
792190Tender No
AEE/17/2024-25 Dt :11.03.2025Tender Authority
Panchayat Raj Engineering Department ViewPurchaser Address
-Website
http://tender.apeprocurement.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lifting Charges for Removal of 15HP SP Set from Intake Well including hire charges for trypod & pulley and other accessories including Cost and conveyence of all material and labour charges etc complete at Clear Water Sump
2
850
1700
... More
Rewinding of 15HP SP set three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required including all labour charges etc., complete at Clear Water Sump
2
6750
13500
... More
Re-errection charges for Lowering of 15HP S.P Set into the Intake well along with all accessories including cost and conveyance of all materials and labour charges etc., complete at Clear Water Sump
2
6371
12742
... More
Replacement of 80mm dia DI PN 1.6 Tamper Proof DI Flanged Single Chamber Air Release Valves with body & cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination Flange drilling as per IS - 1538 and exclusive of all taxes and including transportation.
1
24255
24255
... More
Lifting Charges for Removal of 15HP SP Set from Intake Well including hire charges for trypod & pulley and other accessories including Cost and conveyence of all material and labour charges etc complete at RSF
2
850
1700
... More
Rewinding of 15HP SP set three phase motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enameled wire 'E' class insulation material and testing etc. as required including all labour charges etc., complete at RSF
2
6750
13500
... More
Re-errection charges for Lowering of 15HP S.P Set into the Intake well along with all accessories including cost and conveyance of all materials and labour charges etc., complete at RSF
2
6371
12742
... More
Rectification of Pipeline leakage in 90mm dia HDPE 6Kg/cm2 Pipe line of following diameter of different places including necessary excavation manually or by machinery, dewatering, removing of mud, cleaning of pipe nd leakage portion, cutting the pipe line, jointing & replacing using CID joint including CID Joint inclusive of using all required machinery, lobour, D.G set, fuel, operator, CID Joints, rubber rings, nuts bolts etc complete(but excluding cost of Pipe)-Trech size 0.70x1.00x2.00mts
10
957
9578
... More
Supply Installation Testing and commissioning of self-healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals ,thecapacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing asrequired.
Makes: As per list of recommended brands Supply and Fixing of 10KVA Capacitors - 3Nos
30
425
12768
... More
Supply Installation Testing and commissioning of self-healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals ,thecapacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing asrequired.
Makes: As per list of recommended brands Supply and Fixing of 8KVA Capacitors - 3Nos
24