Municipal Administration And Urban Development Department Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Municipal Administration And Urban Development Department Tender

Works
Eprocure
Opening Date21 Dec 2018
Closing Date21 Jan 2019
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Andhra Pradesh Urban Water Supply And Septage Management Improvement Project With Aiib In Chittoor District, Andhra Pradesh (package - Ii)

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification

4539

-

-

... More
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification

6189.5

-

-

... More
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom in all soils mixed with boulders upto 30 cm size and backfilling in trenches with excavated suitable material by Manual Means (RBR-FNDN-1 (I A i).

16013.2

-

-

... More
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means for disintegrated rock, soft rock, soft shale and medium hard rock comprisiing of lime stone, sand stone, hard shale, schiest, fissured rock without resorting to blasting (RBR-FNDN-1.IV).

2825.9

-

-

... More
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material in all soils by Mechanical Means (RBR-FNDN-1 (I B i).

41760.9

-

-

... More
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material in ordinary rock ( not required blasting) as per Technical Specification (RBR-FNDN-1 (I B i)

2198

-

-

... More
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification

7369.2

-

-

... More
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards but excluding GST and as per the Technical Specification.

-

-

-

... More
110 OD HDPE Pipes

62017

-

-

... More
160 OD HDPE Pipes

3485

-

-

... More
200 OD HDPE Pipes

658

-

-

... More
250 OD HDPE Pipes

1963

-

-

... More
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.

-

-

-

... More
110 OD HDPE Pipes

62017

-

-

... More
160 OD HDPE Pipes

3485

-

-

... More
200 OD HDPE Pipes

658

-

-

... More
250 OD HDPE Pipes

1963

-

-

... More
Supply and Delivery of 300mm dia DI K7 Pipes Centrifugally cast (spun) ductile iron pressure pipes for water, gas and sewage with socket spigot ends conforming to IS.: 8329/2000 in standard working lengths for classification K - 7 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating. Rates are ex-factory,including transportation but excluding taxes & duties.

650

-

-

... More
Lowering 300mm dia D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries but excluding cost and conveyance of pipes from source of supply (Ref to specifications. BIS No.3114/1994)

650

-

-

... More
Jointing 300mm dia D.I. pipes and fittings with rubber gasket (push-on-joint), excluding the cost of the gasket but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete Reference to specifications IS 3114/1994/12888/1987

133

-

-

... More
Supply and Delivery of HDPE fittins conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards but excluding GST and as per the Technical Specification.

-

-

-

... More
MS FLANGES

-

-

-

... More
OD 110

621

-

-

... More
OD 160

36

-

-

... More
OD 200

7

-

-

... More
OD 250

19

-

-

... More
END CAPS

-

-

-

... More
110 OD HDPE

124

-

-

... More
160 OD HDPE

7

-

-

... More
200 OD HDPE

1

-

-

... More
250 OD HDPE

4

-

-

... More
REDUCERS

-

-

-

... More
OD 110mm x 125mm

621

-

-

... More
OD 180mm x 200mm

36

-

-

... More
OD 225mm x 250mm

7

-

-

... More
TEES

-

-

-

... More
110 OD HDPE

621

-

-

... More
160 OD HDPE

36

-

-

... More
200 OD HDPE

7

-

-

... More
250 OD HDPE

19

-

-

... More
BENDS

-

-

-

... More
110 OD HDPE

621

-

-

... More
160 OD HDPE

36

-

-

... More
200 OD HDPE

7

-

-

... More
250 OD HDPE

19

-

-

... More
Supply and Delivery of upto 500mm dia Centrifugally Cast (Spun) Ductile Iron Fittings Conforming to Is:9523/2000 having dimentions as per table. The Rates mentioned here under are for Fittings, Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) ( Ex-Works) including Transportation,but excluding Taxes and Duties Etc.

1760.9

-

-

... More
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking but excluding GST as per standards and as directed by Engineer-in-charge

-

-

-

... More
100mm dia

116

-

-

... More
150mm dia

11

-

-

... More
200mm dia

4

-

-

... More
250mm dia

9

-

-

... More
300mm dia

4

-

-

... More
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification

-

-

-

... More
100mm dia

124

-

-

... More
150mm dia

12

-

-

... More
200mm dia

5

-

-

... More
250mm dia

9

-

-

... More
300mm dia

4

-

-

... More
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking but excluding GST as per standards and as directed by Engineer-in-charge for scour

-

-

-

... More
100mm dia

14

-

-

... More
150mm dia

1

-

-

... More
200mm dia

1

-

-

... More
Supply and Delivery of PN 100mm dia 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking but excluding GST as per standards and as directed by Engineer-in-charge

14

-

-

... More
Supply and delivery of 100mm dia PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking but excluding GSTas per standards and as directed by Engineer-in-charge

14

-

-

... More
Labour charges for 100mm dia fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/Air cushion valve including cost of jointing material such as bolts, nuts and rubber insertions etc., complete and as per technical specification

14

-

-

... More
Manufacture, Supply and Delivery of CI Dismantling Joints with both side flange end suitable for installation in between flange end pipes. These rates are excluding Taxes etc., complete.as per technical specifications

-

-

-

... More
100mm dia

183

-

-

... More
150mm dia

15

-

-

... More
200mm dia

5

-

-

... More
250mm dia

7

-

-

... More
300mm dia

3

-

-

... More
Construction of RCC valve chamber as per department approved type design and as per Technical Specification

-

-

-

... More
100mm

183

-

-

... More
150mm

15

-

-

... More
200mm

5

-

-

... More
250mm

9

-

-

... More
300mm

4

-

-

... More
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification for Trench Restoration

43542.6

-

-

... More
Plain Cement concrete (1:4:8) using 40 mm metal with concrete mixture. For Road restoration as per drawings and as per technical specification clauses for Trench Restoration

4912.7

-

-

... More
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification for Trench Restoration

8597.3

-

-

... More
Manufacturing supply delivery of Electromagnetic flow meter of various sizes as per ISO 9001,meter tube should be of SS304 material, CS flanges of PN10 rating, liner – hard rubber, electrodes – SS316, Coil housing –SS304 fully welded construction for corrosion resistance, IP68 Protection , Accuracy +/- 0.5 % of measured value inclusive of linearity , repeatability etc, Grounding rings of SS304, Display – 2 line backlit LCD display with 8 digit. The complete meter assembly with signal converter must be wet accuracy tested and calibrated as a unit near minimum, intermediate, and maximum specified flow ranges of the meter (full range of flow). The overall uncertainty of the calibration rig should be at least three times better than the uncertainty of the full bore electromagnetic flow meter. The competent Government authority such as FCRI/NABL must certify the test facility with 5 years warranty for Flow meter and has the facility to integrate to SCADA in future (Output should be Pulse and 4-20mA) and as per technical specifications

-

-

-

... More
100mm dia

6

-

-

... More
300mm dia

2

-

-

... More
Manufacturing supply delivery of 100mm dia Pressure reducing valve of Approved make including supply, installation, testing and commissioning upto the satisfaction and as directed by Engineer-in-Charge and as per technical specifications

1

-

-

... More
Providing 15mm dia 5050 Nos New House service connections

-

-

-

... More
Providing 15mm dia House Service Connection as per standard specification including the cost of the materials like Clamp Saddle,Ferrule Tapping Saddle confirming to I.S stadard manufactured from virgin resin of PE-80 , Compression Elbows, MDPE PE100 Pipe including lowering, laying and jointing including earth work excavation,UPVC Casing pipe with Two Calmps for drain crossings,Drilling of Holes for RR Masonary and CC Walls , Boring&Tunneling below CC &BT Roads ,saw cutting of groves in CC Roads and refilling the pipe line trench after laying the pipe line and including cost of 15mm dia meter of BIS standard etc complete as directed by departmental officer for finished item of work.( CC Roads and BT Roads should not be distrubed)

-

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)

2525

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)

1515

-

-

... More
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe)

1010

-

-

... More
Provide installing and giving Satisfactory field testing of battery Operated "B" Class 15mm AMR Ultrasonic Meters having no moving part in Contact with water with magnetically sealed coupled and Hermitically sealed register ,with full brass body confirming to ISO 4064 along with manufacturing test certificate with battery life of min.10 years with GSM /RF Technology for communication to server with PC Software including all materials required for fixing ,labour and giving satisfactory leak proof test etc Complete,General Specifications:-1) Meter should be battery operated with no moving parts,low prtesser ,loss,dry type as per FCRI /MID.2)Display:- 8 digit LCD,3)Encloser :-Protection class IP 68 4) Tempature :-Ambit 50deg .C 5) Pressure:-minimum life of 10 Years 7) Memory built -In and should have storage for at least 12 months with daily /monthly accumulated totailised data with time and date should be available .It should able to access memory of the meter through serial communications 8) End Connection:- Screwed up to 40mm BSP/Npt coupling 9) Installation:- Should be able to install in any orientation 10) Transducre :-Inbuilt as per detailed Technical Specifications. 11) The acceptance /routine test shall be either conducted by M/S.Fliud Control Research In stitute, Palght,Kerala or any of the Laboratories apporved by the National Accerditation Board for Calibration Laboratories (NABL) or EEC pattern apporaval certificates with at least 5 years battery life, including dual channel data loggers ,fixing specials,installation at site etc.. including providing and fixing in position poly propylene water meter box to accommodate water meter all charges and excluding GST

5050

-

-

... More
Supply delivery and comissioning the Handheld Devices for meter reading and bill printing. The power back up of this item shall be for 24 hours, android based with on line and offline capabilities, portable credit/debit card machine reader integrated. The connectivity to the central server will be via rest full services with highest security standards, in json data format as directed by the departmental offer. The bill generation, collection shall reflect across the entire system and the acknoledgement of the receipt shall be sent by SMS to the consumer. SIM charges for 7 years shall be provided. This item shall include the cost of consumables for the defect liability period of 2 years.

8

-

-

... More
Providing for Implementation of Environmental Management Plan in the estimate for Chittoor Municpal Corporation.

-

-

-

... More
I. Monitoring Costs : Construction Phase (Two years)

-

-

-

... More
Air Quality Monitoring ( 5 Monitoring station) once in a month for three seasons during the construction period at distribution network and as per Standard Specifications.

20

-

-

... More
Noise level Monitoring ( 5 Monitoring station) once in a month for three seasons during the construction period distribution network as per Standard Specifications.

20

-

-

... More
Water Quality Monitoring surface / ground (6 Monitoring station) once in a month for three seasons during the construction period distribution network as per Standard Specifications.

10

-

-

... More
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5) as directed by the Engineer - in - Charge

135

-

-

... More
Sprinkling of water with 5000 Litres capacity tankers (excluding rainy days) as directed by the Engineer - in - Charge

450

-

-

... More
Hiring for 1 No Vehicles for 24 Months including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,

24

-

-

... More
PUTTUR MUNICIPALITY (CAPEX)

-

-

-

... More
Provide installing and giving Satisfactory field testing of battery Operated 15mm "B" Class AMR Ultrasonic Meters having no moving part in Contact with water with magnetically sealed coupled and Hermitically sealed register ,with full brass body confirming to ISO 4064 along with manufacturing test certificate with battery life of min.10 years with GSM /RF Technology for communication to server with PC Software including all materials required for fixing ,labour and giving satisfactory leak proof test etc Complete,General Specifications:-1) Meter should be battery operated with no moving parts,low prtesser ,loss,dry type as per FCRI /MID.2)Display:- 8 digit LCD,3)Encloser :-Protection class IP 68 4) Tempature :-Ambit 50deg .C 5) Pressure :-minimum life of 10 Years 7) Memory built -In and should have storage for at least 12 months with daily /monthly accumulated totailised data with time and date should be available .It should able to access memory of the meter through serial communications 8) End Connection:- Screwed up to 40mm BSP/Npt coupling 9) Installation:- Should be able to install in any orientation 10) Transducre :-Inbuilt as per detailed Technical Specifications . 11) The acceptance /routine test shall be either conducted by M/S.Fliud Control Research In stitute ,Palght,Kerala or any of the Laboratories apporved by the National Accerditation Board for Calibration Laboratories (NABL) or EEC pattern apporaval certificates with at least 5 years battery life, including dual channel data loggers ,fixing specials,installation at site etc.. including providing and fixing in position poly propylene water meter box to accommodate water meter all charges and excluding GST

2000

-

-

... More
Supply delivery and comissioning the Handheld Devices for meter reading and bill printing. The power back up of this item shall be for 24 hours , android based with on line and offline capabilities, portable credit/debit card machine reader integrated. The connectivity to the central server will be via rest full services with highest security standards , in json data format as directed by the departmental offer. The bill generation, collection shall reflect across the entire system and the acknoledgement of the receipt shall be sent by SMS to the consumer. SIM charges for 7 years shall be provided. This item shall include the cost of consumables for the defect liability period of 2 years.

2

-

-

... More
Supply distrubution and fixing, installation of Supervisory Control and Data Acuasation System (SCADA) in Disribution system including Chlorine Analyser,Turbidity Analyser and Hand Held Devices etc., Complete.

-

-

-

... More
Chlorine Analyzer: Supply, installation , delivery and testing wall mounted ABS plastic enclosure based Online Chlorine Analyzer of Amphreometric or Potentiometric type. Specifications of Range: 0 to 5 mg/L free or total residual chlorine, Resolution 0.01 PPM, Accuracy: +/- 0.05 PPM or better, Cycle Time: 4 minutes, Inlet: Sample Temperature: 5 to 40 °C, operating Temperature: Range 5 to 60 °C. Local LCD Display to display the values. Output: 4-20 mA or 0-10 VDC to integrate into PLC if needed. PH Compensation must be Auto/Manual. All accessories that are required for the must be provided.This item shall include the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Turbidity Analyzer. Supply, installation , delivery and testing of wall mounted Turbidity Analyzer make of HACH/ ABB/ Forbes Marshall with specifications of Range 0.00-500.0(NTU/FNU), Operating Temperature : 0 – 60 °C, Displayed Resolution : 0.01 (0.00-19.99), 0.1(20.0-500.0)NTU/FNU, Response Time : Initial response in 1 minute, 15 seconds for a full-scale step change Signal, Sample, Temperature : 0 to 50°C (32 to 122°F), Output 4-20mA to integrate into PLC if needed. Local LCD Display to display the values . This item includes the cost of consumables for the defect liability period of 2 years.

1

-

-

... More
Supply, delivery , installation of Data Logger with solar powered , battery backup of 5 days including SIM charges for 7 years, transmission rate shall be every 10 minutes cycle that can be configurable from 2 minutes upto 8 hours as needed.This unit shall have additional battery pack to power up ( 5 days backup) for the instruments connected to this item . The data collected from the instruments such as the bulk flow meter , preassure sensors , chlorine etc must be transmitted to the central SCADA Servers via the restfull web services hosted by the servers in the requred data format.

1

-

-

... More
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
Control Centre Meter Intergations with server as directed by the Engineer - in - Charge

1

-

-

... More
Supply, testing installation and commissioning of command control: Reputed / Branded Hardware servers (2 nos) with 8GB RAM and 1TB Hard Disk including for operating system server license CentOS/Lunix , Windows OS, key board mouse with 20" LED monitor, Routers, firewall, bill printer , as required for running the software and internet broad band connection with static IP for for 84 months . 2 nos desktop with windows operating system with 8GB RAM and 1TB Hardisk, key board mouse and 20" LED monitor , 3 Nos work station with 3 chairs for each work station , racks for servers , network wiring , power wiring , etc . This item shall, including cost, conveyance , warrenty for 2 years , complete as directed by the departmental officers.

1

-

-

... More
Supply, testing and commissioning of 55" LED monitor with Ethernet/HDMI/VGA/WIFI with waranty for 2 years

1

-

-

... More
Software shall have modules such as Consumer master , grievence , billing , reports , SMS integration , Access log module, online payment module , consumer logins , metering details , dash board , with authentication and authorisation module , issue tracker , accounting and finance module. The soft ware shall expose restfull web services for further/future integrations with other software. The database, web-server shall be open source, license free, portable with all internationally accepted security standards. Authorisation and user access control shall be implemented for the applications mentioned. The application/software shall provide Restful Web Service interface with JSON data format so that it can be integrated to other centralised software and the Android application. All the data received from the instruments and meters shall be stored in database for a period of 4 years and reports shall be retrieved on demand. The data shall be integrated to the SCADA server as directed by the deparmental officer.

1

-

-

... More
Printer - 3 in one on color printer with refillable ink bank as directed by the Engineer - in - Charge

1

-

-

... More
Supply, Delivery and Installation of 1600VA UPS with solar panels, battery enclosures with doors along with racks, to provide 40 hours battery backup calculated at 50% load. The solar panels should to charge the battery to full capacity in 7 hours of sunshine. As per relevant specification amended time to time for single phase input with input circuit breakers provided protection, sine wave from with sealed battery, maintenance free, recharge time conform to standards. The Batteries shall be of VLRA Type. This item shall, including cost, conveyance, etc complete as directed by the departmental officers.

1

-

-

... More
CHITTOOR MUNICIPAL CORPORATION OPEX

-

-

-

... More
Manning, Operation and Maintenance of Chittoor Municpal Corporation Water Supply Improvement Scheme For 7 Years.

-

-

-

... More
Supply and delivery of Supervisor ( Diploma Engineer )

84

-

-

... More
Personal required for operating Valves in distribution lines

-

-

-

... More
Valve Operator/Turn Cocks

405

-

-

... More
Helpers for Distribution

810

-

-

... More
Hiring for 1 No Vehicles for 84 Months including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,

84

-

-

... More
Repairs to pumpsets & Water pipe lines ( for Five years )

-

-

-

... More
i)Replacement of glands of sluice valves

200

-

-

... More
II) Replacements of balls of Air valves

200

-

-

... More
Pipe Jointing Materials whenever repairs occurred

-

-

-

... More
Manufacture, Supply, & Delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to anywhere in A.P. etc., complete

-

-

-

... More
MS FLANGES

-

-

-

... More
OD 110

160

-

-

... More
OD 160

8

-

-

... More
OD 200

6

-

-

... More
OD 250

6

-

-

... More
End Caps

-

-

-

... More
OD 110

35

-

-

... More
OD 160

1

-

-

... More
OD 200

1

-

-

... More
OD 250

1

-

-

... More
Reducers

-

-

-

... More
OD 110 x 125 mm

70

-

-

... More
OD 180 x 200mm

4

-

-

... More
OD 225 x 250mm

6

-

-

... More
Tees

-

-

-

... More
OD 110

50

-

-

... More
OD 160

4

-

-

... More
OD 200

6

-

-

... More
OD 250

4

-

-

... More
Bends

-

-

-

... More
OD 110

80

-

-

... More
OD 160

4

-

-

... More
OD 200

6

-

-

... More
OD 250

4

-

-

... More
Service Charge for bill generations , collections and maintainence for 5050consumers x 12 months x 7 years = 424200 . This item includes cost of consumables .

424200

-

-

... More
II. Monitoring costs : Operation Phase ( One year)

-

-

-

... More
Air Quality Monitoring (5 Monitoring stations) twice in a year at distribution network as per Standard Specifications.

10

-

-

... More
Noise level Monitoring ( 5 Monitoring stations) twice in a year at distribution network as per Standard Specifications.

10

-

-

... More
Water Quality Monitoring ( 6 Monitoring Locations) twice in a year at distribution network as per Standard Specifications.

5

-

-

... More
PUTTUR MUNICIPALITY (OPEX)

-

-

-

... More
Manning,Operation and Maintanance of Puttur Municipality Water Supply Improvement Scheme for 7 Years

-

-

-

... More
Personal required for operating Valves in distribution lines

-

-

-

... More
Valve Operator/Turn Cocks

162

-

-

... More
Helpers for Distribution

162

-

-

... More
Purchase pipe jointing materials whenever repairs occurred

-

-

-

... More
DI Detatchable Joints above 300mm

50

-

-

... More
Manufacture, Supply, & Delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to anywhere in A.P. excluding GST etc., complete

-

-

-

... More
MS FLANGES

-

-

-

... More
OD 110

40

-

-

... More
OD 160

8

-

-

... More
OD 200

6

-

-

... More
OD 250

6

-

-

... More
End Caps

-

-

-

... More
OD 110

25

-

-

... More
OD 160

15

-

-

... More
OD 200

3

-

-

... More
OD 250

4

-

-

... More
Reducers

-

-

-

... More
OD 110 x 125 mm

25

-

-

... More
OD 180 x 200mm

10

-

-

... More
OD 225 x 250mm

6

-

-

... More
Tees

-

-

-

... More
OD 110

22

-

-

... More
OD 160

4

-

-

... More
OD 200

6

-

-

... More
OD 250

4

-

-

... More
Bends

-

-

-

... More
OD 110

20

-

-

... More
OD 160

10

-

-

... More
OD 200

10

-

-

... More
OD 250

10

-

-

... More
Providing qualified Diploma with minimum 2 Years of experience in SCADA/Computers , flow meters and instruments maintainence etc including daily routine checks on HMI , Flowmeter , PLC at all locations around the project and also operate ( 1 techinican x 366 days x 7 years = 2562 days ) inc ESI, PF and other statutory levies as directed by the departmental officers

2562

-

-

... More
Service Charge for bill generations , collections and maintainence for 2000 consumers x 12 months x 7 years = 168000 . This item includes cost of consumables .

168000

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.