Hindustan Shipyard Limited Tender
... More
The HSL has issued a formal invitation for competitive bids for the Hindustan Shipyard Limited project, for Battery Charger Rectifier And Ups Servicing Works On in Visakhapatnam, Andhra Pradesh. The bid opening date for this tender is 28-05-2025 and the last date for bid submission is 30-05-2025. Interested bidders for Hindustan Shipyard Limited tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.
Hindustan Shipyard Limited - HSL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 May 2025
Closing Date30 May 2025
Tender AmountRefer Documents
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Battery Charger Rectifier And Ups Servicing Works On
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_HSL_97205_3Tender No
20 / 22040 / 059 / Rectifier and UPS/ 2025-26Tender Authority
Hindustan Shipyard Limited ViewPurchaser Address
-Website
http://https://www.hslvizag.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Commercial Questionnaire, HSL GTC, GST Compliance
BOQ Items
... More
3 KW BATTERY, 24V CHARGER - 1, M/S RADIANT ELECTRONICS:
FLUCTUATIONS IN OUTPUT VOLTAGE.IS OBSERVED. OVERHAULING OF 12V, 3KW BATTERY CHARGER IS REQUIRED.
VARIOUS ITEMS OF TRANSRECTIFIER ARE MALFUNCTIONING. REPLACEMENT OF BELOW MENTIONED ITEMS IS REQUIRED: -
(A) 10 AMP, 3 POLE ON/OFF SWITCH (QTY-1)
(B) INDICATING LAMP WITH COVER (QTY-1)
(C) LAMP 220 V (QTY-3)
(D) FUSE LINK- 6A (QTY-3)
(E) FUSE LINK-2A (QTY-3)
(F) FUSE LINK-125A (QTY-1)
(G) FUSE BASE-250A (QTY-1)
(H) FUSE BASE-15A (QTY-1)
(J) 10A, 3POLE, 4 WAY VOLTAGE CONTROL SWITCH (QTY-1)
(K) SURGE SUPPRESSOR CAPACITOR (QTY-1)
(L) SET OF COILS (3NOS) FOR TRANSFORMER (QTY-1)
(M) DIODE (QTY-2)
-
-
-
... More
3 KW BATTERY, 24V CHARGER - 2, M/S RADIANT ELECTRONICS:
FLUCTUATIONS IN OUTPUT VOLTAGE.IS OBSERVED. OVERHAULING OF 24V, 3KW BATTERY CHARGER IS REQUIRED. VARIOUS ITEMS OF TRANSRECTIFIER ARE MALFUNCTIONING. REPLACEMENT OF BELOW MENTIONED ITEMS IS REQUIRED: -
(A) 10 AMP, 3 POLE ON/OFF SWITCH (QTY-1)
(B) INDICATING LAMP WITH COVER (QTY-1)
(C) LAMP 220 V (QTY-3)
(D) DIODE (QTY-2)
(E) FUSE BASE-250A (QTY-1)
(F) FUSE BASE-400A (QTY-1)
(G) 10A, 3POLE, 4 WAY VOLTAGE CONTROL SWITCH (QTY-1)
(H) SURGE SUPPRESSOR CAPACITOR (QTY-1)
(K) SET OF COILS (3NOS) FOR TRANSFORMER (QTY-1)
-
-
-
... More
4 KW BATTERY, 12V CHARGER, M/S RADIANT ELECTRONIC:
VARIOUS ITEMS OF TRANSRECTIFIER ARE MALFUNCTIONING. REPLACEMENT OF BELOW MENTIONED ITEMS IS REQUIRED: -
(A) 6 AMP, 3 POLE ON/OFF SWITCH (QTY-1)
(B) INDICATING LAMP WITH COVER (QTY-1)
(C) LAMP 220 V (QTY-3)
(D) FUSE LINK- 2A (QTY-3)
(E) FUSE LINK-50A (QTY-3)
(F) FUSE BASE-63A (QTY-1)
(G) FUSE BASE-15A (QTY-1)
(H) 6A, 3POLE, 4 WAY VOLTAGE CONTROL SWITCH (QTY-1)
(J) SURGE SUPPRESSOR CAPACITOR (QTY-1)
(K) SET OF COILS (3NOS) FOR TRANSFORMER (QTY-1)
(L) DIODE (QTY-2)
-
-
-
... More
3KW TRANS-RECTIFERS, M/s RADIANT ELECTRONIC TRANSFORMER RECTIFIER: Input Voltage: 415 V, 3 Phase, 50 Hz. Output Voltage: 12/24 V DC
FREQUENT VOLTAGE DROPS OBSERVED. OVERHAULING OF THE RECTIFIER IS REQUIRED. WORK INCLUDES REMOVAL OF THE RECTIFIER AND REWINDING. FITMENT OF THE RECTIFIER POST REWINDING AND TRIALS.
-
-
-
... More
1KW TRANS-RECTIFERS, M/s RADIANT ELECTRONIC TRANSFORMER RECTIFIER:
FLUCTUATIONS IN OUTPUT VOLTAGE.IS OBSERVED. OVERHAULING OF 24V, 1KW BATTERY CHARGER IS REQUIRED.
-
-
-
... More
CABLE FROM RECTIFIER TO CHARGING TERMINALS INSIDE BCR COMPARTMENT IS PERISHED. RECABLING FROM RECTIFIER TO CHARGING TERMINALS IS REQUIRED FROM 03 RECTIFIERS TO 06 BATTERY CHARGING TERMINALS. WORK INVOLVES GLAND PIERCING, LAYING OF CABLE AND GLAND PACKING. (CABLE LENGTH - 100 MTRs, CABLE TYPE - 02 CORE 04 SQMM).
-
-
-
... More
BATTERY CHARGER, M/S ELAK(PORTABLE) :
24V,1 KW PORTABLE BATTERY CHARGING RECTIFIER IS NOT WORKING. REPAIR/ REPLACEMENT OF 24V, 1 KW PORTABLE BATTERY CHARGING RECTIFIER IS REQUIRED.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements