East Coast Railway Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
East Coast Railway - ECOR Tender
Telecommunication Services
Ireps
Opening Date16 Jul 2024
Closing Date6 Aug 2024
Tender Amount₹ 60,47,536.4
Costs
EMD
₹ 1,21,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
S&t Portion Of Work In Connection With Upgradation Of Vbl, Dmnj & Pvp Stations Under Amrit Bharat Scheme
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
AB_UPGRAD_VBL_DMNJ_PVP-WALTAIR DIVISION-S AND T/ECORTender No
AB_UPGRAD_VBL_DMNJ_PVPTender Authority
East Coast Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavation of trenches of following depth and width 0.3 Meter detailed below including clearing of roots and trees etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, 4 ramming, consolidation o f soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Signalling Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS. Note: Before refilling of the trenches, the cable laid are to be tested and recorded for its insulation value and after satisfaction of site Engineer the refilling process should start and after monsoon the route is to be attended for backfilling the rain cuts, wash out of soils where ever found. Depth 1.0 M
2.4
88821
213170.4
Excavation of trenches including clearing of roots of trees etc., in rocky area up to a depth to be indicated by Railway Engineer at site as per the site condition [Minimum 0.6 meter] and width 0.3 Mts. at the 6 bottom. This includes concreting & plastering as per the instructions of site Engineer and complete back filling by digging earth from a lead of 30 Mtr. In case 0.8 meter depth or higher is achieved no concreting is required, otherwise concreting up to 100 mm thickness should be done. All materials required for the above works shall be supplied by the Contractor.
75
255
19125
Excavation of trenches in all kinds of soils including soft rocky area and clearing of track etc. to a depth of 1.0 M and width of 0.3 M for track crossing /pucca road/level crossing gate/platform/station circulating area or any other place as advised by site Engineer including transportation and laying of DWC/RCC/Split 7 RCC/G.I. pipes with or without coupler. This includes repairing of track/pucca road/level crossing gate/ platform/station circulating area surface to original position by ramming and concreting wherever required soon after the work is over. DWC/RCC/GI pipes shall be supplied by the Railway. DWC pipes wherever required shall be supplied in 6 Mtr. length and shall be cut to size as per requirement. All other materials including cement are to be supplied by the contractor.
162
335
54270
Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. 8 to 1.0 mtr a t places to be indicated by site Engineer for entering of cables inside the building. Only G.I pipes supplied by Railway and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonry floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer and also transportation of G.I Pipe from Store by the tenderer.
6
6108
36648
Massonary chase cutting 3/2" X 3/2" at work site plastering of PVC pipe in the chase, drawl of 2/5/10/20/50 pair switch board cable through it, covering and plastering the chase with contractor's cement. All materials required for the work are to be supplied by the contractor.
600
406
243600
Fixing of aluminium/Krone type CT Boxes/rossetts and termination on following PIJF/U/G cable, SB cables in cable termination box including all other works required for cable termination. This includes plumbing of cable, painting, cementing & lettering of CT box.
3
481
1443
Excavation of trench of size 15cm X 30cm on platform with different surfaces duly cutting the platform with tile/platform cutting machine and laying of cables through CPVC/G.I. pipe of required size at site duly removing the existing platform surface such as shabad stone, granite etc., without damaging . The surface of the 1 platform to be restores to its original shape after completion of work. In case the platform surface stones are damaged, the contractor has to arrange for the tiles /tiles of similar type at his own cost. During digging, all precautions to be taken to avoid inconvenience to the travelling public. The work is to be carried out preferably when the platform is free from occupancy. Protection, barricading arrangement has to be done on platform till the work is completed. All materials including CPVC/GI pipe has to be arranged by the contractor as per the site condition.
750
433
324750
Fixing of PVC conduit pipes firmly with wall and ceiling sealing with PVC saddles at regular interval of 50 cm.
6830
2
13660
Laying and drawing of Data communication cable through 25 mm PVC conduit pipe.
1150
9
10350
Laying and drawing of Power cable through 25 mm PVC conduit pipe.
1150
15
17250
Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU.
6
83
498
Installation, testing and commissioning of 4K HD 8 MP Bullet type IP Colour camera.
11
2697
29667
Supply of Permanently lubricated two layer type HDPE duct, outer dia 40 mm, inner dia 33 mm with 1 three end plugs and two couplers for every Km length of pipe in length of 500 m confirming to RDSO Spec. No. RDSO/SPN/TC/45/2013.Rev.2.0 Amendment 2.0 or latest. Inspection by representative of Railway. Note: The HDPE Duct should be pre inserted with 4 mm nylon rope, inside the HDPE Duct.
2.6
132496
344489.6
Supply of Screened cable 2 core with PVC pipe (Thickness 2mm, dia 25mm). Inspection by the Representative of Railway.
1900
44
83600
PVC Switch board cable 20 pair/0.5mm, as per TEC Spec No- GR/WIR-06/03, MAR-2002 with latest Amendment. Inspection by the Representative of Railway.
600
97
58200
PVC Switch board cable 10 pair/0.5mm, as per TEC Spec No- GR/WIR-06/03, MAR-2002 with latest Amendment. Inspection by the Representative of Railway.
600
60
36000
Supply of double walled corrugated pipe 6 mtr in length, 120 mm outer dia and 103 mm inner dia, 5 with one suitable coupler conforming to RDSO Specification No. RDSO/SPN/204/2011 Version 1.1 Amdt 1 or latest for underground cable protection. Colour-Orange. Inspection by the Representative of Railway. Note: If required, the DWC pipe shall be supplied split in two halves.
27
4117
111159
Supply of 100 Pair Krone CT Box with LSA plus disconnecting modules, Make- M/s Krone Communication Bangalore. Inspection by the Representative of Railway.
3
4389
13167
Supply of Large Professional Large Format Display (55") as per Technical specification in Annexure-II. Make: GLOBUS, SAMSUNG, LG or similar. Inspection by Representative of Railway.
5
44623
223115
Supply of PA Column Speaker , Make: Ahuja or similar Inspection by Representative of Railway.
13
1908
24804
Supply of 12 Core OFC cable with armoured ECCS tape (single mode OS1 HDPE Fibre cable for 3 Networking) as per Technical Specification In Annexure-III per conforming to IEC 60793-1 , IEC 60793-2, and to conform other normative specifications as specified in IEC: 60793 part 1 and Part 2. Inspection by Representative of Railway.
2500
27
67500
Supply of 6 Core armoured Optical Fibre Single Mode Cable as per Technical Specification In Annexure-V. Inspection by Representative of Railway.
1500
20
30000
Supply of White PVC Pipe of dia 1 Inch (25mm) of Standard IS :9537 (Part 3) as per Technical specification in Annexure-VI attached with Pipe length of 3mtrs each. Inspection by Representative of Railway.
6830
33
225390
Supply of CAT 6 U/UTP cable for Indoor use 305 mtrs as per Technical Specification In Annexure- VII. Inspection by Representative of Railway.
6
3965
23790
Supply of 5 pair colour coded and PVC insulated twin twisted overall and pair shielded data communication cable (7 strands of min 0.3 mm dia). Inspection by Representative of Railway.
1150
44
50600
Supply of 8 port with 2 SFP networking switch with PoE (8 ports Managed PoE + Layer 2 access Switch) as per Technical Specification in Annexure-VIII. Inspection by Representative of Railway.
15
9440
141600
Supply of 24 port PoE Switch gigabit smart managed switch + 4 SFP DGS-1210 as per Technical Specification in Annexure-IX. Make: D-Link or similar. Inspection by Representative of Railway.
9
19388
174492
Supply of Caller ID Push button Telephone as per Technical Specification in Annexure-X. Make: Alcatel or Giga set or similar. Inspection by Representative of Railway.
60
629
37740
Supply of HDMI cable (20 Mtr) as per Technical Specification in Annexure-XI. Inspection by Representative of Railway.
6
2800
16800
Supply of 8 port HDMI splitter as per Technical Specification in Annexure-XII. Inspection by Representative of Railway.
3
2478
7434
Supply of 12 port loaded LIU rack mountable, LIU as per Technical Specification in Annexure-XIII. Inspection by Representative of Railway.
6
5219
31314
Supply of Single Mode OFC Patch Cord (length-5m) (LC-SC/SC-SC/LC-LC/FC-LC) as per site requirement and as per Technical Specification in Annexure-XIV. Inspection by Representative of Railway.
60
981
58860
Supply of 30 Mbps 2W/4W/LAN Extender supporting short and longer distance [upto 10 Kms or more] dual power supply AC/DC as per Technical Specification in Annexure-XV. Inspection by Representative of Railway.
3
24662
73986
Supply of Microphone, Make : Ahuja or similar. Inspection by Representative of Railway.
3
2582
7746
Supply of Microphone Cable (Shielded) 2 Core 15 Stands. Inspection by Representative of Railway.
150
5
750
Supply of Microphone stand, Make: Ahuja or similar. Inspection by Representative of Railway.
3
991
2973
Supply of Wireless router 300 mbps as per Technical Specification in Annexure-XVI. Inspection by Representative of Railway.
15
968
14520
Supply of desktop computers with Intel core i3, 4 GB RAM, 1TB HDD, DVD r/w, 22 Inch LED 21 Monitor, Keyboard, mouse , with operating system as legal Windows 10 professional, with Legal MS office, with 3 years onsite warranty, Desired make of computers: HP, ACER, DELL or Similar. Inspection by Representative of Railway.
3
44586
133758
Supply of 32 channel, 4 SATA port with 4 TB storage NVR as per Technical Specification in Annexure-XVII (32 CH NVR, 4 SATA + 2 LAN, 4 TB HDD). Inspection by Representative of Railway.
3
35919
107757
Supply, transportation & installation of Optical Fibre cable joint enclosure RDSO spec. No: RDSO/SPN/TC/68/2014 Rev.0.1 Amd or latest and splicing of OFC (24 Fibre) and testing. OFC splicing shall be done in presence of Railway Representative. For supply portion Inspection by representative of Railway.
15
18027
270405
Krone type fibre box indoor surface installation complete with modules and locks suitable for 50 pair. Inspection by the Representative of Railway.
3
7443
22329
Supply and installation of OFC distribution (management system) box as per RDSO Spec. 4 RDSO/SPN/TC/037-2000, Drg. N0. RDSO/TCDO-170, suitable for 19" rack complete with 24 fibre FCPC/STPC couplers 24 pitails and suitable tray as per specification and drawing. Make 3M model:8423 or similar (latest version). This includes transportation, Installation and testing. This includes transportation, Installation and testing. Inspection by representative of railway.
6
79334
476004
Supply, Installation and Commissioning of 5 KVA Online UPS Double conversion with external battery and battery rack, UPS capacity 5.0 KVA indicative back up time120 Minutes as per Technical Specification in Annexure-XVIII, Inspection by Representative of Railway.
3
85550
256650
Supply, transportation, installation and commissioning of 19" Rack 6 U as per Technical Specification in Annexure-XIX. Inspection by Representative of Railway.
12
6225
74700
Supply, transportation, installation and commissioning of 19", 9 U wall mount Rack as per Technical Specification in Annexure-XX. Inspection by Representative of Railway.
12
8113
97356
Supply and Installation of 2MP 30XPTZ camera (Make: HIK Vision or similar) as per Technical Specification in Annexure-XXI. Inspection by Representative of Railway.
10
44559
445590
Supply & installation of 2 MP IP bullet camera optics day/night functionality smart IR, upto 30 mtrs (98 ft) IR distance optical glass window with higher light transmission IR anti-reflection window to decrease the 5 infrared transmittance 2D/3D DNR (Digital Noise Reduction) compression ultra 265, H.265, H 264, MJPEG ROI (Region of interest) network ONVIF conformance structure wide temperature range: -30deg C to 60deg.C (- 22deg F to 140deg.F) wide voltage range of +-25% IP67 3-Axis. Make/brand- cp plus or hikvision or similar. Inspection by Representative of Railway
25
3796
94900
Supply and installation of centralized storage recording server for CCTV network to the details as per technical specification in Annexure-IV Inspection by RITES.
3
247800
743400
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements