Central Bank Of India Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Central Bank Of India - CBI Tender
Civil And Construction
Building Construction
Eprocure
Opening Date19 Jun 2024
Closing Date6 Jul 2024
Tender Amount₹ 7,44,220
Costs
EMD
₹ 30,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Summary
Interior Work Icluding Elecrical And Cabling
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CBoI_760363_1Tender No
RAJAHMUNDRY CURRENCY CHESTTender Authority
Central Bank Of India ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Notice for inviting tender to for participating undertaking interior works including woodwork, electrical, data cabling, AC works and seating provision for the new premises for the proposed Currency Chest at Rajahmundry Branch, Rajahmundry.
Technical Bid
Financial Bid
BOQ Items
Providing & Fixing Branch Manager table & side table made of Phenol bonded, water proof (BWP) 18mm thk Commercial ply IS303 framework & necessary 2" X 2" & 2" X 1 1/2" SalWood supports & bedding patti as required. The height of the table including side table shall be 2'-6". Depth of the table shall be 3'-0" & side table shall be 1'-6". The table shall have one drawer for key board at the corner of the table & side table. The 1'-6" wide side-unit to have two drawers and one shutter below the drawers at the side of the table. The front apron shall be made of Phenol bonded, water proof (BWP) 12mm thk Commercial ply IS303 framework covered with additional phenol bonded, water proof (BWP) 12mm thk Commercial ply IS303 finished with approved shade / make/laminate as per Banks Standard Design.
-
-
-
Side table to have 2 Drawers at the top and 1 openable shelf at the bottom. All the exposed surfaces of the table & side table shall be finished in 1.00mm thick approved color laminate for vertical surfaces and 1.5mm thk approved color laminate for horizontal surfaces, made Phenol bonded, water proof (BWP) 12mm thk Commercial ply IS303 framework tapered box finish, Foot Rest with Rubber Matting, Brass Powder Coated Wire Manager, Twin Telepscopic Drawer Fittings, Locks, CPU metal stand with casters, necessary teak wood round 2" Moulding etc. complete as per instruction of the Architect.
-
-
-
All exposed surfaces including working TOP of counter shall have decorative laminate. All exposed surfaces shall have 1.00mm thk approved color laminate in two shades for vertical surfaces & approved color 1.5mm thick laminate for horizontal surfaces.The internal surfaces shall have same finish including approved Single Lock for Drawer Units, approved Stainless Steel Brush Finish Handles, approved Brass Powder Coated Wire Manager, Twin Type Telescopic Drawer Channels, Footrest with Rubber Matting etc. complete as per instructions of Architect.
-
-
-
The rates shall be inclusive of making of the opening for the Electrical / ComputerWires / Switches & A.C. Pipes etc. complete. All exposed portion, beading, moulding shall be of 1st Quality Teak Wood only without knots.
1
-
-
COUNTER WITH SIDE TABLE/Long L Table
-
-
-
Table Size: - 11-9" X 2'-0"
-
-
-
Side Table Size: - 11-3" X 2'-0"
-
-
-
Providing & Fixing Providing and fixing staff L shaped work stations with same main specifications of table as BM table, but without modesty, item includes 3 Drawer units and accesories as above, Finished with 1.0 mm thk. Laminate
-
-
-
The rates shall be inclusive of making of the opening for the Electrical / ComputerWires / Switches & A.C. Pipes etc. complete. All exposed portion, beading, moulding shall be of 1st Quality Teak Wood only without knots.
1
-
-
FIRE-RATED FULL HEIGHT PARTITION upto 8'6" for
ELECTRICAL ROOM including Fire-rated Door
-
-
-
Supply and installation of Bison Panel (cement bonded particle board) with Fire rating of 240 hrs with required components such a Rockwool tight puff, supporting studs and additional fitments, finished on both sides with laminate as per above items with provision of fire- rated door of 3' x 7' with necessary fitttings with louvers at the bottom for air circulation
59.5
-
-
BOTH SIDE LAMINATE DOOR WITH DOOR FRAME
-
-
-
Providing & fixing both side laminate door including door frame made out of 4" X2 1/2" C.P.T.Wood frame fixed as per required position including shutters madeout of 4" X 1 1/2" teak wood frame all round with 6" X 1 1/2" panel at 3'-0" in height including 2" X 1 1/2" brass at 1'-6" c/c both ways. 6mm thk Commercial ply (MR grade) IS303 covering on both sides finish with approved color 1.00mm thk laminate including frame work of approved shade / make along with PUNIT or SHALIMAR make Heavy Brass Hinges, Brush Finish Stainless Steel Handles, door stopper, door closure, powder-coated Tower Bolts, etc.complete as per the instructions of Architect.
-
-
-
LOCKERS upto 7'0" height- Laminate Finish
-
-
-
Providing & Erecting full height storage 1'-6" deep. Each unit to contain 28 locker shelves with closed shutter and individual locks for each locker. All exposed surfaces finished with 1.00mm thick laminate of approved shade from outside & similar finish on the inside including SS fittings and Fixtures, Stainless Steel Brush Finish Handles, high quality locks, Box Hinges, Shelf size at 1'-0" c/c as per instructions of the Architect.
28
-
-
GYPSUM / HILUX FALSE CEILING WITH PAINTING
-
-
-
Providing & Fixing suspended Gypsum / Hilux Board Grid with PoP ceiling combination false ceiling including recess/drop as per Architect design/detail drawing, which includes providing & fixing G.I.Perimeter channels of size 0.55mm thick having one flange of 20mm &another flange of 30mm & a web of 27mm along with perimeter of ceiling screwfixed to brick wall / partition with the help of nylon sleeves and screws at 600mmcenters then suspending G.I. Intermediate channels of size 45mm X 0.9mm thickwith 2 flanges of 15mm each from the soffit at 1220mm centers with ceiling angle of width 25 X 10mm X 0.55mm thick fixed to soffit with G.I. & steel expansion fastners. Ceiling section of 0.55mm thickness having knurled verb of 51.5mm & two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips & in direction perpendicular to the intermediate channel at 457mm centers.12.5mm tapered edge gypboard (conforming to IS-2095-1982) is then screw fixed to ceiling to ceiling section with 25mm drywait at 230mm centers.Screw fixing is done mechanically either with screwdriver of drilling machine withsuitable attachment.The boards are to be jointed and finished so as to have a flush look, which includesfilling with CRACK SEAL / tape & finishing the tapered & square edges of theboards with jointing compound, paper tape & two coats of primer suitable for Gypboard.
-
-
-
Rate includes provision for recessed/dropped portion in the ceiling with necessary provision for concealed optical fibre lighting as per design specified by architect
-
-
-
Note: - For light fittings, grills diffusers and cutouts, speakers, fire detectors etc.have to be made with the frame of perimeter channels of size 20 X 27 X 30mm X0.545mm thick, supported suitably as per direction of Architect, Electric or A.C.Consultants & shown as per detail drawing without additional payments.
-
-
-
Entire false ceiling shall be finish with 3 coats of ICI. Plastic Emulsion paint withnecessary scraping, palti, leveling & smooth finish with scaffolding, cleaning etc.
-
-
-
Note:- Area of the False Ceiling will be measured in plan i.e. wall to wall.
-
-
-
Note: - Existing false ceiling should be removed without any extra charge by theContractor and carefully stacked as directed / taken out from site.
-
-
-
12mm Thk MAIN GLASS DOOR - 3' wide single leaf door
-
-
-
Providing and Fixing 12mm thick Toughened glass main door with Garware Film (Ice Dot) (Basic Cost Rs.36/-Per SFT) or "V" cut engraving fixed in the frame work along with Brush Finish Stainless Steel 1" Dia 2'-0" Height approved design Handles with 8 Lever Locks, Pull & Push Plate, DORMA make Heavy Duty Floor Spring, etc.complete as per instructions of the Architect.
63
-
-
BOXING AT ENTRANCE DOORWAY
-
-
-
Providing & fixing laminate boxing made of Phenol bonded, water proof (BWP) 18mm thk Commercial ply IS303 framework & necessary 2" X 2" & 2" X 1 1/2" SalWood supports. The height of the boxing should be upto ceiling ifrom lintel height. Depth of the boxing shall be 15'' and length must cover the complete length of the Branch entrance. The boxing must be finished with approved shade / make/laminate as per Banks Standard Design.
40
-
-
SINGLE COTS with MATTRESS and Pillows- 3' x 6'
1
-
-
Supply and installation of MS single cot with head panel along with 4" foam mattress and pillows
-
-
-
BUNKER COTS with MATTRESS and Pillows- 3' x 6' x 2
1
-
-
Supply and installation of MS single (1+1) cot with head panel along with 4" foam mattress and pillows
-
-
-
WARDROBE upto 7'0" height- Laminate Finish
-
-
-
Providing & Erecting full height storage 2'-0" deep. The top, sides, drawers, slidingshutters / folding shutters and shelves shall be made out of 18mm thk Commercial ply (MR grade) IS303 with C.P.T.Wood frame work.All exposed surfaces finished with 1.00mm thick laminate of approved shade from outside & similar finish on the inside including Brass fittings and Fixtures, Stainless Steel Brush Finish Handles, 6" Tower Bolts, Box Hinges, Shelves at 1'-6" c/c with drawer below as shown in the detail drawing & instructions of the Architect.
-
-
-
FULL HEIGHT PARTITION FULLY/PARTIALLY
GLAZED (Both Side Laminate Finish) upto 8'6"
-
-
-
Providing & Erecting in position approx 8'-6" height or as per the actual sitecondition partitions to be made out of 2" X 2" G.I. sectional frame work 1'-6" / 2'-0" c/c both ways with proper joinery finished with 9mm thk Commercial ply (MR grade) IS303 covering on both sides finished with approved color 1.00mm thk laminateon the outside, complete with wherever support is required, G.I. Sections shall be rigidly fixed to the existing Ceiling, Floors, Beams, Doors & the Side Walls, whichever is applicable, as per instructions of Architect. Wherever required, partial glazing with Garware Film (Ice Dot) (Basic Cost Of Film Rs.50/- Per SFT) fixed (at one inch from cut-out edge) as a border to semicircular cut-out and top.
-
-
-
All the exposed surfaces of the partition including grooves as required / directedon the site, upto false ceiling height shall be finished with 1.00mm thick laminate in 2 or 3 shades. 4" Bank branding to be provided at top and bottom level.
-
-
-
The necessary openings in the partitions shall be provided for A.C. Grill, ElectricalConduits, Electrical Switches, Light Fixtures, Painting, A.C. Opening, Running Display, Speaker, Fire Detectors, Electric Fixtures, Wall Paintings, Planter Boxes,Mirror, Fixtures as per requirements or instructions.
-
-
-
NOTE: - Height of the partitions upto sofit of false ceiling shall be considered for payment but not above it. However the alternate & corner vertical members of the partitions shall continue up to the
R.C.C. Ceiling
-
-
-
Total for Furnishing Works
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements