To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Bharat Heavy Electricals Limited - BHEL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Oct 2024
Closing Date8 Nov 2024
Tender Amount₹ 16,93,000
Costs
EMD
₹ 33,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Preventive And Breakdown Maintenance Of Ht, Lt Breakers And Transformers
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BHEL_41448_1Bid Award Id
ViewTender No
MandS/PandC/2024/61Tender Authority
Bharat Heavy Electricals Limited ViewPurchaser Address
-Website
http://https://eprocurebhel.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Maintenance of LT capacitor banks (detailed scope in Annexure A)
30
619
18599.4
Maintenance of DC tripping units and charges (detailed scope in Annexure A)
50
110
5520.5
Dusting and cleaning (detailed scope in Annexure A)
350
474
166089
Transformer oil filtration to improve dielectric strength of oil with High Vacuum Filter machine of capacity 2400 LPH or more. The filter unit shall filter Transformer oil to achieve BDV of 60 KV or more. The party shall have authorisation from the licensing authorities to test and issue the test certificates. The party shall issue transformer oil test certificates as per IS 6792. The job also includes filling of the transformer if low oil level. The transformers are located at various locations in the factory. The transformer of various capacities from 1000 KVA to 16000 KVA will be given for filteration as per the availability. Power Supply will be provided by BHEL Free of cost
97913
2
274156.4
Transformer oil BDV Testing before and after Transformer oil filteration. Reports of Transformer Oil BDV to be given before Filteration. (Total Transformers = 70). The lab issuing the test report should be certified by NABL and should have authorisation given by the CEIG for issuing test certificated on BDV. The authorisation letter should be submitted at the time of test reports
56
387
21672
Transformer oil acidity testing charges before and after filteration. (Total Transformers = 70).This should be done as per IS 1448. The method used should be stated while submitting tender. The lab issuing the test report should be certified by NABL and should have authorisation given by the CEIG for issuing test certificate. The authorisation letter should be submitted at the time of test reports.
56
466
26096
Transformer oil testing for moisture content (PPM) as per IS 13567:1992, Tan Delta as per IS: 6262: 1971 before and after filteration (Total Transformers = 70). The lab issuing the test report should be certified by NABL and should have authorisation given by the CEIG for issuing test certificate. The authorisation letter should be submitted at the time of test reports.
56
764
42803.6
Leakage Arresting of the list of Transformers up to 3000 KVA highlighted in Annexure - A. The details of the Transformers, type of leakage, make and year of manufacturing. The type of leakage is also given in the annexure. All the required tools required for leakage arresting is under the scope. All the materials required for Leakage arresting are under the scope of the vendor. Gaskets used should be of 70 C grade. Oil seals and O rings are also under the vendor scope
2
24412
48825.8
Shifting, laying and dressing of the following cables:
-
-
-
1C X 500 sq.mm cable
40
40
1630
3C X 95 sq.mm cable
80
52
4212
3.5C X 300 sq.mm LT PVC cable
140
90
12600
In soil, excavation of 1000mm deep and 500mm width trench, supply & spreading of sand, supply & laying of bricks & shabad stone as per IS:1255 1983 and back filling after laying the cable with marking plates. Existing HT cables are lying in the route. Hence, Contractor has to take additional safety precautions. If any existing cable happens to be damaged during the above excavation, the responsibility lies with the contractor for repair/restoration of cable at free of cost to BHEL.
100
678
67820
Execution of Straight through joints for the following HT/LT cables
-
-
-
1C X 500 sq.mm cable
8
2681
21450.08
3C X 95 sq.mm cable
10
3605
36050
3.5C X 300 sq.mm LT PVC cable
14
3605
50470
Removal of existing cables, dismantling, shifting to Scrap Yard or handing over of the following items to Power distribution or following the instructions of the Site Engineer
-
-
-
b) 415V LT ACB panel of size: 4150mm X 1000mm X 2300mm. Approx. weight: 3000Kgs
1
7899
7899.6
Shifting, Assembly, Erection, Testing & Commissioning of free issued CSS LT Extension panel of size 2060mm (L) X 575mm (B) X 1900mm (H) inside T3 Substation. Feeder combination of panel: Incoming - 2000A ACB(2 nos), Outgoing - 630A MCCB (6 nos). Approximate Weight: 500 Kgs.
1
7066
7066.08