Archaeological Survey Of India Tender

... More
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Archaeological Survey Of India - ASI Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date18 Feb 2022
Closing Date26 Feb 2022
Tender Amount₹ 94,40,180 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Proof of EMD or MSME and Application for Tender as per Clause no 10
Tender acceptance and declaration, Power of Attorney
Technical Eligibility Documents Clause 7.01 to 7.10 and Annexure VIII
Work Experience Details
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Item No.3: "Supply, installation, testing & commissioning of Approved BIS standard Indian make LED Floodlight luminaire with system power [170W ± 5%], Available in colour temperature 3000K, made of a single piece Pressure die cast aluminium (PDC) housing with separate driver and optical compartment for Thermal isolation & Powder coated. The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of 10° for optimum light spread. The colour of the fixture should be terracotta. With 5 years of Comprehensive Operation, Maintenance including defect liability period. Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor 0.95, THD 10%, IP67 protection, Luminaire has a Ingress protection of IP66 and Impact Resistance of IK07. Certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%. The luminaire should be provided with Electrical safety class I. Power Factor 0.9. Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge with proper metal cages for lights protections"

19

-

-

... More
Item No.4: Supply, installation, testing & commissioning of Approved BIS standard Indian make LED Floodlight luminaire with system power [50W ± 5%], available in colour temperature 2200K, made of a single piece Pressure die cast aluminium (PDC) housing with separate driver and optical compartment for Thermal isolation & Powder coated. The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of 60° for optimum light spread. The colour of the fixture should be terracotta. with 5 years of Comprehensive Operation, Maintenance including defect liability period. Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor 0.95, THD 10%, IP67 protection, Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK07. Certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%. The luminaire should be provided with Electrical safety class I. Power Factor 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge with proper metal cages for lights protections.

12

-

-

... More
Item No.5: "Supply, installation, testing & commissioning of Approved BIS standard Indian make LED Floodlight luminaire with system power [50W ± 5%], available in colour temperature 3000K, made of a single piece Pressure die cast aluminium (PDC) housing with separate driver and optical compartment for Thermal isolation & Powder coated, The fixture provided has to be with an injection moulded UV stabilized Polycarbonate cover & Lens optics with beam angle of 60° for optimum light spread. The colour of the fixture should be terracotta. Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-305V AC, power factor 0.95, THD 10%, IP67 protection, Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK07. Certification: CE Certified, ROHS compliant, BIS Certification for Luminaires & Drivers Driver Efficiency :85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%. The luminaire should be provided with Electrical safety class I. Power Factor 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge with proper metal cages for lights protections."

24

-

-

... More
Item No.6: "Supply, installation, testing &commissioning of Approved BIS standard Indian make LED Floodlight luminaire with system power [15W ± 5%], available in color temperature of 3000K and beam angle 30 degree, made of Pressure die cast Aluminium [PDC] Housing for better Thermal Dissipation.Powder coated. The colour of fixture should be terracotta. Tilt angle 180' deg. Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V, power factor 0.95, THD 5%, IP66 protection. Luminaire should have an Ingress protection of IP66 and Impact Resistance of IK08. Ø Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & DriversDriver Efficiency :85%, Operating Temperature: 0°C to +50°C, Operating Humidity: 10%-90%. The luminaire should be provided with Electrical safety class I. Power Factor 0.9.Housing to have adjustable base bracket for angle adjustment so that the light direction can be adjusted to illuminate desired structural elements. The work also includes all the accessories , connections in main LT panel box and of all wires, cable, earthing and MCCB/MCBs as per Engineer-in-Charge with proper metal cages for lights protections."

40

-

-

... More
Item No.7: "Supply, installation, testing &commissioning of Approved BIS standard Indian make LED luminaire with system power [20W ± 5%], Available in color temperature 3000K and beam angle of 30 degree, made of Pressure die cast Aluminium [PDC] housing for better Thermal Dissipation. Powder coated. The colour of fixture should be Teracotta. with 5 years of Comprehensive Operation, Maintenance including defect liability period. Integral encapsulated high efficiency electronic driver having a Aluminium extrusion construction with rated voltage of 140-270V, power factor 0.95, THD 5%, IP66 protection. Luminaire has a Ingress protection of IP66 and Impact Resistance of IK08. Ø Certification: CE Certified, Design Patented/Registered, ROHS compliant, BIS Certification for Luminaires & Drivers.

20

-

-

... More
Item No.8: Supply, installation, testing & commissioning of standard Indian make customised Outdoor rated Bollard Pathway Light 10W with housing of Pre cast Concrete Cement Body or Terracota Sandblast / Grey Finish Coating and Light fixture body : Aluminium / PC Luminaire Wattage 10W, Well designed thermal management system with aluminium heat sink Operating Voltage of AC 165-270V 50HZ with universal elcectronic driver, Light colour should be iny range of 2700-3000K, , Mean rated service life L70(tq 25 °C) = 50,000 h.Ingress protection rating (DIN EN 60529): IP65, with "OEM Certification for this tender" The luminaire should be provided with Electrical safety class I. Operating Temperature 0 deg to +50 deg with 5 years of Comprehensive Operation, Maintenance including defect liability period..

58

-

-

... More
Item No.09 Suuply, installation, testing & commissioning of the required earthing system (3 nos.) as per standard engineering practice and the drawings attached. The sectional drawing for the recommended earthing system is attached for reference. To be verified by Engineer-in-charge.

3

-

-

... More
Item No.10 Supply & Installation of Stone fitments, in sandstone to match with the existing material of the monument, with special adhesive for Luminarie installations. Size would range from 15cm to 50cm, as per site requirement & to be verified by Engineer-in-charge.

110

-

-

... More
Item No.11 Supply & Installation of customised wooden channel/conduit & stone channel/conduit (for pathways) , made up of exterior-grade water-resistant/ weatherproof/ termite proof, salt resistant and sturdy MDF board to accommodate the running cables throughout the monument. Thickness of the MDF board should be minimum 10mm. The section drawing is attached for reference.

820

-

-

... More
Item No.12 Supply and Laying of one number 4 core x25 sq mm ISI Marked Aluminium UnArmoured PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground or pipe or trench as required including excavation, sand cushioning, protective covering and refilling the trench etc as required.

50

-

-

... More
Item No.13 Supply and laying of 4.0 sq. mm x 3 core ISI marked, FRLS PVC insulated, single core copper conductor cable in the wooden channel with proper connections, glands, etc

1100

-

-

... More
Item No.14 Supply and fixing Power Supply 24V, 6.3A, 150W

100

-

-

... More
Item No.15 Supply and fixing IP67 weatherproof box for Power Supply with cable glands at input and output of the box, size of the box should be sufficient to accommodate the power supply of the fixtures.

235

-

-

... More
Item No.16 Excavation of soft soil with minimum depth of 300 mm and maximum upto 900 mm and width of 300 mm required for laying of main cable/branch luminarie cables etc. and refill with 15cm thick River sand covered with precast slab/ brick and remaining with earth and to bring back the earth in original condition and providing inspection chambers wherever required.

200

-

-

... More
Item No.17 DEFECT LIABILITY PERIOD 5 YEARS - FREE MAINTENANCE OF THE ILLUMINATION FOR FIVE YEARS. 17(a) Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc. from the date of testing and commissioning of the project for the first year

1

-

-

... More
Item No.17(b). Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc. for 2nd year from the date of expiring the first year warranty period, after testing and commissioning of the project for the Second year

1

-

-

... More
Item No.17(c). Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc for 3rd year from the date expiring the second year warranty period For the third year

1

-

-

... More
Item No.17(d). Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc for 4th year from the date expiring the third year warranty period For the fourth year

1

-

-

... More
Item No.17 (e). Operation & Maintenance and defect liability Charges including replacement of defective fixtures, cables, labour charges etc for 5th year from the date expiring the fourth year warranty period For the fifth Year

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.