Andhra Pradesh Education And Welfare Infrastructure Development Corporation Tender
To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.
Andhra Pradesh Education And Welfare Infrastructure Development Corporation - APEWIDC Tender
Pipes and Pipe Related Activities
Opening Date18 Dec 2020
Closing Date28 Dec 2020
Tender Amount₹ 1,81,26,470 This is an estimated amount, exact amount may vary.
Costs
EMD
Refer DocumentsDocument Cost
Refer DocumentsTender Fee
₹ 35,400
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
364549Bid Award Id
ViewTender No
104/MD/APEWIDC/VJA/2020-21, Dated: 09.12.2020Tender Authority
Andhra Pradesh Education And Welfare Infrastructure Development Corporation ViewPurchaser Address
-Website
http://tender.apeprocurement.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R- 410A),refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: Mitsubishi /DAIKIN/Toshiba/O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary
ODU should delvier the required capacity at the ambient conditions of the place as per ISHRAE Standards. The System should be highly energy efficient and COP shall not be less than 3.7.
The outdoor units shall be suitable for operation between 5 and 53 deg C in
cooling mode. 12 HP 70% payment on delivery
2
499906
249953
... More
Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R- 410A),refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: Mitsubishi /DAIKIN/Toshiba/O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary
ODU should delvier the required capacity at the ambient conditions of the place as per ISHRAE Standards. The System should be highly energy efficient and COP shall not be less than 3.7.
The outdoor units shall be suitable for operation between 5 and 53 deg C in
cooling mode. 14 Hp
70% payment on delivery
2
565803
282901.35
... More
Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R- 410A),refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: Mitsubishi /DAIKIN/Toshiba/O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary
ODU should delvier the required capacity at the ambient conditions of the place as per ISHRAE Standards. The System should be highly energy efficient and COP shall not be less than 3.7.
The outdoor units shall be suitable for operation between 5 and 53 deg C in
cooling mode. 16 HP
70% payment on delivery
3
968000
322666.6
... More
Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R- 410A),refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: Mitsubishi /DAIKIN/Toshiba/O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary
ODU should delvier the required capacity at the ambient conditions of the place as per ISHRAE Standards. The System should be highly energy efficient and COP shall not be less than 3.7.
The outdoor units shall be suitable for operation between 5 and 53 deg C in
cooling mode. 18 HP 70% payment on delivery
2
708958
354478.8
... More
Supply of Air cooled VRV / VRF Air Conditioning system of having high COP complete with indoor and outdoor units duly charged with refrigerant R-410A and oil (first charge) suitable for cooling with individual controller, (suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and complete with all accessories, fittings etc. The units shall be BMS Compatible. Outdoor Units shall be fully inverter system complete with 100% scroll/rotary compressor and drive arrangement, initial charge of refrigerant (R- 410A),refrigerant piping, drier, sight glass, dual pressure cutout all housed and supported properly in cabinet, air cooled condenser & its controller for following capacities. The VRV system shall be cooling only system. Makes: Mitsubishi /DAIKIN/Toshiba/O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary
ODU should delvier the required capacity at the ambient conditions of the place as per ISHRAE Standards. The System should be highly energy efficient and COP shall not be less than 3.7.
The outdoor units shall be suitable for operation between 5 and 53 deg C in
cooling mode. 20 HP 70% payment on delivery
8
3117596
389699.45
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/ Toshiba/ O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Hi Wall type units 1 TR 70% payment on delivery
18
562394
31244.13
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba/ O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Hi Wall type units 1.6 TR
70% payment on delivery
6
204507
34084.5
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba/ O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Hi Wall type units 2.0 TR
70% payment on delivery
2
70441
35220.65
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 0.63 TR 70% payment on delivery
11
458964
41724
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 0.83 TR 70% payment on delivery
1
41724
41724
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 1.0 TR 70% payment on delivery
3
124749
41583.09
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 1.5 TR
70% payment on delivery
32
1490629
46582.15
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 2.0 TR 70% payment on delivery
26
1240676
47718.3
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 2.6 TR
70% payment on delivery
42
2195042
52262.9
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 3.2 TR
70% payment on delivery
1
53399
53399.05
... More
Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower section and drive arrangement, initial charge of refrigerant & oil, integral refrigerant piping, electronic expansion valve, electrical panel with controls and duly wired, thermostatic control. Makes: Mitsubishi /DAIKIN/Toshiba /O General/LG/Samsung/Voltas/Blue Star/Carrier/Hitachi/Panasonic Type Of Units :Roundflow/4 way Cassette units 4.0 TR
70% payment on delivery
8
436282
54535.2
... More
Supply and Installation of Ref Nets for Triple ODU connections ODU
1
10453
10452.58
... More
Supply and Installation of Multi Connection Joint / Ref Nets for IDUs ODU
1
4772
4771.83
... More
Low Side Equipments
-
-
-
... More
Lifting, shifting, positioning, Installation and testing of the ODUs including all accessories with Vibration Isolators for ODUs etc., complete 6 to 8 HP
2
15906
7953.05
... More
Lifting, shifting, positioning, Installation and testing of the ODUs including all accessories with Vibration Isolators for ODUs etc., complete 10 to 12 HP
3
34085
11361.5
... More
Lifting, shifting, positioning, Installation and testing of the ODUs including all accessories with Vibration Isolators for ODUs etc., complete 14 to 20 HP
15
204507
13633.8
... More
Lifting Shifting, Positioning ,Installation Testing and commissioning of the following indoor units with including all required accessoires etc complete.,
Type Of Units :Hi Wall Units 1.0 TR to 2.0 TR
26
35448
1363.38
... More
Lifting Shifting, Positioning ,Installation Testing and commissioning of the following indoor units with including all required accessoires etc complete., Type Of Units :Round Flow /4 way Cassette units 1.0 TR to 2.0 TR
73
124409
1704.23
... More
Lifting Shifting, Positioning ,Installation Testing and commissioning of the following indoor units with including all required accessoires etc complete., Type Of Units :Round Flow /4 way Cassette units 2.6 TR to 4.5 TR
51
144859
2840.38
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's recommendations 41.30 mm Dia
300
630564
2101.88
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's recommendations 34.9 mm Dia
300
391971
1306.57
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's recommendations 28.60 mm Dia
300
357888
1192.96
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's recommendations 22.20mm Dia
100
107934
1079.34
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site akes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's
recommendations 19.10 mm Dia
100
96573
965.73
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's recommendations 15.90 mm Dia
100
85211
852.11
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico
The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's
recommendations 12.70 mm Dia
100
73850
738.5
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site Makes:Totaline/Mandav/Mexico The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's recommendations 9.52 mm Dia
100
54535
545.35
... More
Supply, installation and testing of Refrigerant Piping consisting of Copper tubes of wall thickness 20G/22G inclusive of Suction Gas Piping & Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber Insulation with finish as required.The piping to be mounted & supported properly with suitable size of clamp,M.S. hanger, tray etc., as required at site akes:Totaline/Mandav/Mexico
The insulation shall be closed cell/cross linked elastomeric Nitrile rubber of thickness 13/19 mm. The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and above 19.1 mm dia, the insulation thickness shall be 19 mm. Testing of refrigerant piping and procedure shall be done as per Manufacturer's
recommendations 6.40 mm Dia
125
59648
477.18
... More
Providing Pressure testing of entire system with Nitrogen and vaccuming nitrogen for all indoor and outdoor units. The pressure testing shall be done as per OEM recommendation. Gas
318
451620
1420.19
... More
Supply and transportation of R 410A Gas for the system. Gas
636
758723
1192.96
... More
Supply and Transportation of XLPE/PVC insulated & PVC sheathed unarmoured control cables of 1.1 KV grade with copper conductor as per IS 7098 Part-I -1988 etc complete Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/ Gloster/ orbit /Paragon/RR Kabel/RPG Wire 2C x 1.5 sq.mm
1300
132925
102.25
... More
Supply and Fixing of 25 mm outer dia 2.20 mm thick Heavy grade with IS:9537 part 3 FRLS regid PVC pipe (ISI MARK,Makes:- VIP / Besto plast / GoldMedal / Million plast / GM / Sudhakar / Polyline) concealed in Roof Slabs with all required MS deep boxes and all accessories including and labour charges etc., complete. Makes:- VIP / Besto plast / GoldMedal / Million plast / GM / Sudhakar / Polyline 25 mm(2.20mm thickness)
1300
115635
88.95
... More
Supply, installation and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings(Including enlarger, bends, T Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap. 25 mm dia
200
34084
170.42
... More
Supply, installation and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings(Including enlarger, bends, T Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap. 32 mm dia
200
40902
204.51
... More
Supply, installation and testing of UPVC Drain Piping with 6mm Nitrile Rubber class "O" Insulation covered with interwoven glass cloth protection. Necessary pipe fittings(Including enlarger, bends, T Joints etc) has to be considered to connect the UPVC drain pipe to cast iron floor trap. 40 mm dia
350
87483
249.95
... More
Supply, installation, testing &commissioning of Stand alone, intelligent Touch controller with Display for controlling the indoor & outdoor units from a Remote place for all the circuits.
1
84075
84075.1
... More
70% of amount will be released for supply equipment to work site and balance 25% after installation/ commission only
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements