Andhra Pradesh Central Power Distribution Company Limited Tender

To know what Andhra Pradesh government has posted about any AP etender, Bidassist helps us to get a one-stop platform where a registered bidder can have access to the details on each and every eprocurement tender. There is no need to provide the details on the AP E-procurement website i.e. https://www.apeprocurement.gov.in as BidAssist helps us find the specific etender we're looking for. BidAassist has collated each and every Eproc Andhra Pradesh Tender on its website.

Andhra Pradesh Central Power Distribution Company Limited - APCPDCL Tender

Works
Electrical and Electronics
Eprocure
Opening Date30 Jan 2021
Closing Date25 Feb 2021
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Providing 3 Ph Supply To 59 Lwe Effetced Villages In Guntur District

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SUPPLY AND ERECTION OF LINES AND DTRS FOR PROVIDING 3 PHASE POWER SUPPLY TO LEFT WING EXTREMISM (LWE) EFFECTED VILLAGES IN GUNTUR DISTRICT WITH FINANCIAL ASSISTANCE FROM WORLD BANK
BILL OF QUANTITIES
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Foundation (Plinth) for VCB

-

-

-

... More
Cement concrete (1:4:8) using 40mm size well graded, HBG metal for foundations, including cost of conveyance of materials, all leads and lifts, consolidation, curing etc., complete for finished item of work. (base concreting) (including seigniorage charges) (MATERIAL PORTION)

1

-

-

... More
Cement concrete (1:3:6) using 20 mm size well graded, HBG metal for foundations, including cost of conveyance of materials, all leads and lifts, consolidation, curing etc., complete for finished item of work. (base concreting) (including seigniorage charges) (MATERIAL PORTION)

6

-

-

... More
White washing two coats with Surya cem of approved quality to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials, labour charges and incidental such as scaffolding, lift charges etc., complete for finished item of work.(MATERIAL PORTION)

14

-

-

... More
11 KV Isolators (400 A) double break with post type insulators with Earth AB Switch(G.I. Bolts should only be used)

16

-

-

... More
11KV 20 KA, feeder VCB with CTs (400-200-100/1-1 A) & Control & Relay Panel with all accessories as per specification

8

-

-

... More
24 V, 40 AH Bttery set including Battery Charger of Conventional Type for 11KV VCB as per Specification

8

-

-

... More
75 x 8 mm M.S. Flat (Earth Mat)

18

-

-

... More
50 x 6 mm M.S. Flat (Risers)

560

-

-

... More
Connecting the VCB to bus with fired wedge connectors

-

-

-

... More
Single 200 sq. mm ACSR Conductor

160

-

-

... More
Wedge connector suitable for four hole paddle for PT/ CT/ CB/ Isolator etc for termination with ampact panther conductor

48

-

-

... More
Wedge connector suitable for four hole paddle for PT/ CT/ CB/ Isolator etc for termination with ampact DOG conductor

24

-

-

... More
Wedge connector suitable for single panther to single panther conductor

24

-

-

... More
Four hole paddle 895 A for termination for PT/ CT/CB/ Isolator etc

48

-

-

... More
Four hole paddle 610 A for termination for PT/ CT/CB/ Isolator etc

24

-

-

... More
Palm connector suitable for (20 to 25 mm )dia stud

24

-

-

... More
Erection of 11KV line with 55Sq.mm AAA Conductor over proposed 9.1 Mts PSCC Poles (including erection of 11KV line in place of existing 6.3 KV line)

-

-

-

... More
9.1M long 280Kg working load PSCC pole

6432

-

-

... More
1.07Mts V 'X' arms/ Chanel Cross arm with back clamp and bolts and nuts complete as per specification

6432

-

-

... More
11 KV Top Cleat with clamp for 9.1Mtrs. PSCC poles

6432

-

-

... More
11 KV side arm with strut with 75X40X6 mm MS Channel & 50X50X6 mm MS Angle including cost of materials, bolts & nuts.

1072

-

-

... More
Special clamps made up of 50X6 mm MS Flat including cost of materials, bolts & nuts.

2144

-

-

... More
Supply and erection of Double-pole structure with 9.1M long 280Kg working load PSCC poles including pit excavation in all soils, back filling, bracing sets, 40 mm dia 2.5 Mtr. GI pipe earthing, running of earths with GI No.8 Earth wire and 6Nos. 11KV Composite Polymer Insulators with metal parts, 3Nos. 11KV Pin Insulators with GI Pin and hardware complete as per drawing duly providing 4Nos. Stay Sets with base palte and Clamps (excluding base concreting & Stay concreting) (as per technical specification) (MATERIAL PORTION)

143

-

-

... More
11KV 45KN Composite Polymer Insulator & Hard ware as per specification

25726

-

-

... More
11KV 45KN Composite Polymer Insulator & Hard ware as per specification

6432

-

-

... More
11KV Stay set complete with base palate and clamps including fixing of bow, fixing and binding of eye bolts, anchor roads, guy insulators

2144

-

-

... More
Sprial earth coil

6432

-

-

... More
Cement concrete (1:4:8) using 40mm size well graded, HBG metal including cost of all materials and curing dewatering the pits before and after concreting viz., dry, wet, partially submerged, fully submerged, rocky etc., complete for PSCC pole as per specification where ever necessary as per the department instructions. (MATERIAL PORTION)

-

-

-

... More
Concreting of Pit size: 0.76X0.76X1.6Mtrs. (0.924 Cum) for 9.1 Mt PSCC Pole (Where ever essential)

1072

-

-

... More
Stay Concreting of Pit size: (0.3 Mt X 0.45 MtX 1.2 Mt) (0.162 Cum) ( Where ever essential)

715

-

-

... More
55Sq.mm AAA Conductor as per Specification

1093

-

-

... More
Supply & Erection of 100 KVA & 25 KVA DTRs - MATERIAL PORTION

-

-

-

... More
9.1M long 280Kg working load PSCC pole

227

-

-

... More
1.5 Mtrs 11KV Tapping Channel Cross arm with 75x40mm with back clamp made up of 50X6mm MS flat

454

-

-

... More
11KV 45KN Composite Polymer Insulator & Hard ware as per specification

681

-

-

... More
11KV 45KN Composite Polymer Insulator & Hard ware as per specification

1362

-

-

... More
11 KV 200 Amp tilting AB switch with insulators along with 2Nos. 2' length of 75X40X6mm MS channel for supporting AB switch pipe and 1No. Stay clamp set, 1No. Back clamp 50X6mm MS flat, 2Nos. MS angle 50X50X6mm of 2' length for supporting AB switch including bolts, nuts & washers

227

-

-

... More
11 KV Horn Gap fuse unit including bolts, nuts and washers

227

-

-

... More
Weather proof LT Disribution box made out of sheet moulded compound (SMC) with flame retardant properties as per specification (6 Nos.300A, 500V knife type porcelain fuse units)

227

-

-

... More
Construction of DTR plinths-Size 4'x4'x6'(above ground) and 4'x4'x3' (below ground) with brick masonry / RR masonry wall - Excavation of pit of size 4’x4’x3’, laying bed concrete with CC(1:4:8) using 40mm and 20mm HBG metal for 6” depth, Construction of distribution transformer plinth with 9” thick 8' height brick masonry wall in CM (1:6) all-round, filling the hollow portion with sand, laying of 6” thick PCC (1:3:6) using 20 mm and 12mm HBG metal on top and plastering all-round the outer side of wall with CM (1:5) 12mm thick and white washing two coats, including cost and Transport of all materials.(MATERIAL PORTION)

227

-

-

... More
11KV/440 V, 3-Ph OUTDOOR 100KVA Amorphous / CRGO Core Aluminium conductor , STAR-2 BIS marked (Energy Efficiency Level-III) Distribution Transformer as per specification

95

-

-

... More
11KV/440 V, 3-Ph OUTDOOR 63KVA Amorphous / CRGO Core Aluminium conductor , STAR-2 BIS marked (Energy Efficiency Level-III) Distribution Transformer as per specification

49

-

-

... More
11KV/440 V, 3-Ph OUTDOOR 25 KVA Amorphous / CRGO Core Aluminium conductor , STAR-2 BIS marked (Energy Efficiency Level-III) Distribution Transformer as per specification

83

-

-

... More
120Sq.mm Single core XLPE cable for Wiring of 3-Ph 100 KVA DTR with suitable U clamps, Supporting Channel with 2ft flat of 50x6mm, lugs etc - Cost per each DTR (with 40 Mt Cable)

95

-

-

... More
95 Sq.mm Single core XLPE cable for Wiring of 3-Ph 25 KVA DTR with suitable U clamps, Supporting Channel with 2ft flat of 50x6mm, lugs etc - Cost per each DTR (with 40 Mt Cable)

132

-

-

... More
80mm dia 6mm thick 2.54Mtrs. long CI earth pipe with 25 mmX3 mm G.I.Earth Flat, with bentonite powder and soil with ratio 1:4 as per standards

598

-

-

... More
11KV Stay set complete with base palate and clamps including fixing of bow, fixing and binding of eye bolts, anchor roads, guy insulators

210

-

-

... More
Cement concrete (1:4:8) using 40mm size well graded, HBG metal including cost of all materials and curing dewatering the pits before and after concreting viz., dry, wet, partially submerged, fully submerged, rocky etc., complete for PSCC pole as per specification where ever necessary as per the department instructions. (MATERIAL PORTION)

-

-

-

... More
Concreting of Pit size: 0.76X0.76X1.6Mtrs. (0.924 Cum) for 9.1 Mt PSCC Pole( Where ever essential)

227

-

-

... More
Stay Concreting of Pit size: (0.3 Mt X 0.45 MtX 1.2 Mt) (0.162 Cum) ( Where ever essential)

227

-

-

... More
Providing security fencing of size 2.4m x 3m x3m (total area 28.8 sqm) to Distribution Transformer structures with gate and locking arrangement which is one side removable and three sides fixed fencing using G.I. Chain link mesh 8 gauge 50.8mm x 50.8mm (2” x2”) size, MS angle 50 x 50 x 6, MS flat 35 x 6, MS flat 25x 6, bolts, nuts, Aldrop, hinges, concreting the supports with PCC (1:3:6), painting one coat red oxide, two coats synthetic enamel paint, complete for finished item of work . Whenever it is not possible to provide fencing of size 2.4mx3mx3m, then size may be reduced and payment shall be arranged based on the actual area. (MATERIAL PORTION)

6537.6

-

-

... More
Conversion of LT S-Ph 3W line to LT 3-Ph 5 W line

-

-

-

... More
8.0 M long 200Kg working load PSCC pole

1126

-

-

... More
LT 3-Ph 5W cross arm ( 50x50x6 mm MS Angle ) with suitable back clamp made up of 50X6mm MS flat including cost of bolt & nuts and washers etc.,

6475

-

-

... More
LT Pin insulator with GI pin with double nuts & double washers

21395

-

-

... More
LT Shackle insulators with metal parts

5630

-

-

... More
LT Stay set complete including fixing of bow, fixing and binding of eye bolts, anchor roads, guy insulators

1689

-

-

... More
34Sq.mm AAA Conductor as per specification

920

-

-

... More
LABOUR

-

-

-

... More
Erection of 2 Nos. 11 KV Bays with VCBs & Addl. 8 Nos. VCBs in the existing 33/11KV Sub-Stations

-

-

-

... More
Erection Charges for Structural supports (GI Joists 150 x 150 mm drilling holes etc.,) and structural Members (GI Channel 100 x 50mm) , GI Angle and seating channels, G.I. bolts & Nuts including transport, loading and unloading charges complete

2

-

-

... More
Foundation (Plinth) for VCB

-

-

-

... More
Cement concrete (1:4:8) using 40mm size well graded, HBG metal for foundations, including cost of conveyance of materials, all leads and lifts, consolidation, curing etc., complete for finished item of work. (base concreting) (including seigniorage charges) (LABOUR PORTION)

1

-

-

... More
Cement concrete (1:3:6) using 20 mm size well graded, HBG metal for foundations, including cost of conveyance of materials, all leads and lifts, consolidation, curing etc., complete for finished item of work. (base concreting) (including seigniorage charges) (LABOUR PORTION)

6

-

-

... More
White washing two coats with Surya cem of approved quality to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials including cost of all materials, labour charges and incidental such as scaffolding, lift charges etc., complete for finished item of work.(LABOUR PORTION)

14

-

-

... More
Erection Charges of 11 KV Isolators (400 A) double break with post type insulators with Earth AB Switch (with G.I. Bolts) including transport, loading & unloading Charges complete

16

-

-

... More
Erection Charges of 11KV 20 KA, feeder VCB with CTs (400-200-100/1-1 A) & Control & Relay Panel with all accessories as per specification including transport, loading & unloading Charges complete

8

-

-

... More
Erection of 24 V, 40 AH Bttery set including Battery Charger of Conventional Type for 11KV VCB including transport, loading & unloading charges complete as per Specification

8

-

-

... More
Laying of earth mat including excavation of trenches welding and fixing of trenches welding and fixing lugs, connecting to equipment and including connecting cast iron pipes with the following size of MS flats. including transport, loading , unloading & erection charges

-

-

-

... More
75 x 8 mm M.S. Flat (Earth Mat)

18

-

-

... More
50 x 6 mm M.S. Flat (Risers)

560

-

-

... More
Connecting the VCB to bus with fired wedge connectors (LABOUR CHARGES)

-

-

-

... More
Coonecting the equipment with Wedge connector suitable for four hole paddle for PT/ CT/ CB/ Isolator etc for termination with ampact panther conductor including transport, loading, unloading Charges complete

48

-

-

... More
Coonecting the equipment with Wedge connector suitable for four hole paddle for PT/ CT/ CB/ Isolator etc for termination with ampact DOG conductor including transport, loading, unloading Charges complete

24

-

-

... More
Coonecting the equipment with Wedge connector suitable for single panther to single panther conductor including transport, loading, unloading Charges complete

24

-

-

... More
Coonecting the equipment with Four hole paddle 895 A for termination for PT/ CT/CB/ Isolator etc including transport, loading, unloading Charges complete

48

-

-

... More
Coonecting the equipment with Four hole paddle 610 A for termination for PT/ CT/CB/ Isolator etc including transport, loading, unloading Charges complete

24

-

-

... More
Coonecting the equipment with Palm connector suitable for (20 to 25 mm )dia stud including transport, loading, unloading Charges complete

24

-

-

... More
Erection of 11KV line with 55Sq.mm AAA Conductor over proposed 9.1 Mts PSCC Poles (including erection of 11KV line in place of existing 6.3 KV line)

-

-

-

... More
Detailed survey and tree clearance

357

-

-

... More
Erection of 9.1M long 280Kg working load PSCC poles including pit excavation (pit size 0.6X0.75X1.5Mtrs.) in all soils except which require blasting as per specification (excluding cost of pole concreting) including transport, loading, unloading Charges complete

6432

-

-

... More
Erection of 1.07Mts V 'X' arms/ chanel cross arm with back clamp and bolts and nuts complete as per specification including transport, loading, unloading Charges complete

6432

-

-

... More
Erection of 11 KV Top Cleat with clamp for 9.1Mtrs. PSCC poles including transport, loading, unloading Charges complete

6432

-

-

... More
Erection of 11 KV side arm with strut with 75X40X6 mm MS Channel & 50X50X6 mm MS Angle including transport, loading, unloading Charges complete

1072

-

-

... More
Erection of special clamps made up of 50X6 mm MS Flat

2144

-

-

... More
Supply and erection of Double-pole structure with 9.1M long 280Kg working load PSCC poles including pit excavation in all soils, back filling, bracing sets, 40 mm dia 2.5 Mtr. GI pipe earthing, running of earths with GI No.8 Earth wire and 6Nos. 11KV Composite Polymer Insulators with metal parts, 3Nos. 11KV Pin Insulators with GI Pin and hardware complete as per drawing duly providing 4Nos. Stay Sets with base palte and Clamps (excluding base concreting & Stay concreting) (as per technical specification) (LABOUR PORTION)

143

-

-

... More
Erection of 11KV 45KN composite polymer insulators & Hard ware as per specification including transport, loading, unloading Charges complete

25726

-

-

... More
Erection of 11KV 45KN composite polymer insulators & Hard ware as per specification including transport, loading, unloading Charges complete

6432

-

-

... More
Erection of 11KV Stay set complete with base palate and clamps including fixing of bow, fixing and binding of eye bolts, anchor roads, guy insulators and pit excavation in all soils except which require blasting as per specification (excluding concreting)

2144

-

-

... More
Fixing of Sprial earth coil

6432

-

-

... More
Cement concrete (1:4:8) using 40mm size well graded, HBG metal including cost of all materials and curing dewatering the pits before and after concreting viz., dry, wet, partially submerged, fully submerged, rocky etc., complete for PSCC pole as per specification where ever necessary as per the department instructions. (LABOUR PORTION)

-

-

-

... More
Concreting of Pit size: 0.76X0.76X1.6Mtrs. (0.924 Cum) for 9.1 Mt PSCC Pole( Where ever essential)

1072

-

-

... More
Stay Concreting of Pit size: (0.3 Mt X 0.45 MtX 1.2 Mt) (0.162 Cum) ( Where ever essential)

715

-

-

... More
Paving out 55Sq.mm AAA Conductor and stringing duly arranging temporary guys, jointing, clamping, jumpering, pin binding, tensioning and strain insulators binding etc., on the poles maintaining ground clearances as per specification including transport, loading and unloading charges and including providing of double jumpers at cut point

1093

-

-

... More
Numbering of poles with AC black paint as back ground and white paint for numbering complete as per specification.

6432

-

-

... More
Erection of 100 KVA & 25 KVA DTRs - LABOUR

-

-

-

... More
Erection of 9.1M long 280Kg working load PSCC poles including pit excavation (pit size 0.6X0.75X1.5Mtrs.) in all soils except which require blasting as per specification (excluding cost of pole concreting) including transport, loading, unloading Charges complete

227

-

-

... More
Erection of 1.5 Mtrs 11KV Tapping Channel x-arm 75x40mm with back clamp made up of size 50X6mm MS flat including transport, loading, unloading Charges complete

454

-

-

... More
Erection of 11KV 45KN composite polymer insulators & Hard ware as per specification including transport, loading, unloading Charges complete

681

-

-

... More
Erection of 11KV 45KN composite polymer insulators & Hard ware as per specification including transport, loading, unloading Charges complete

1362

-

-

... More
Erection of 11 KV 200 Amp tilting AB switch with insulators on already erected 9.1 M PSCC pole along with 2Nos. 2' length of 75X40X6mm MS channel for supporting AB switch pipe and 1No. Stay clamp set, 1No. Back clamp 50X6mm MS flat, 2Nos. MS angle 50X50X6mm of 2' length for supporting AB switch including bolts, nuts & washers including transport, loading, unloading Charges complete

227

-

-

... More
Erection of 11 KV Horn Gap fuse unit on already erected 9.1 m PSCC pole with complete structure of HG fuse set including bolts, nuts and washers including transport, loading, unloading Charges complete

227

-

-

... More
Fixing of Weather proof LT Disribution box made out of sheet moulded compound (SMC) with flame retardant properties as per specification (6 Nos.300A, 500V knife type porcelain fuse units)

227

-

-

... More
Construction of DTR plinths-Size 4'x4'x6'(above ground) and 4'x4'x3' (below ground) with brick masonry / RR masonry wall - Excavation of pit of size 4’x4’x3’, laying bed concrete with CC(1:4:8) using 40mm and 20mm HBG metal for 6” depth, Construction of distribution transformer plinth with 9” thick 8' height brick masonry wall in CM (1:6) all-round, filling the hollow portion with sand, laying of 6” thick PCC (1:3:6) using 20 mm and 12mm HBG metal on top and plastering all-round the outer side of wall with CM (1:5) 12mm thick and white washing two coats, including cost and Transport of all materials.(LABOUR PORTION)

227

-

-

... More
Erection of 11KV/440 V, 3-Ph 100 KVA DTR as per specification including transport, loading, unloading Charges complete

95

-

-

... More
Erection of 11KV/440 V, 3-Ph 63 KVA DTR as per specification including transport, loading, unloading Charges complete

49

-

-

... More
Erection of 11KV/440 V, 3-Ph 25 KVA DTR as per specification including transport, loading, unloading Charges complete

83

-

-

... More
Wiring of 3-Ph 100 KVA DTR with 120Sq.mm Single core XLPE cable from transformer LV bushing to A type distribution box and from A type distribution box to LT line with suitable clamps,channel,lugs,jumpering etc.including transport, loading, unloading Charges complete

95

-

-

... More
Wiring of 3-Ph 63/25 KVA DTR with 95Sq.mm Single core XLPE cable from transformer LV bushing to A type distribution box and from A type distribution box to LT line with suitable clamps,channel,lugs,jumpering etc.including transport, loading, unloading Charges complete

132

-

-

... More
Providing Earthing with 80mm dia 6mm thick 2.54Mtrs. long CI earth pipe including excavation of pit, earthing with 25mmX3mm Earth Flat, supply and refilling the pit with bentonite powder and soil with ratio 1:4 and giving connections etc., as per departmental standards including transport, loading, unloading Charges complete

598

-

-

... More
Erection of 11KV Stay set complete with base palate and clamps including fixing of bow, fixing and binding of eye bolts, anchor roads, guy insulators and pit excavation in all soils except which require blasting as per specification (excluding concreting)

227

-

-

... More
Cement concrete (1:4:8) using 40mm size well graded, HBG metal including cost of all materials and curing dewatering the pits before and after concreting viz., dry, wet, partially submerged, fully submerged, rocky etc., complete for PSCC pole as per specification where ever necessary as per the department instructions. (LABOUR PORTION)

-

-

-

... More
Concreting of Pit size: 0.76X0.76X1.6Mtrs. (0.924 Cum) for 9.1 Mt PSCC Pole( Where ever essential)

227

-

-

... More
Stay Concreting of Pit size: (0.3 Mt X 0.45 MtX 1.2 Mt) (0.162 Cum) ( Where ever essential)

227

-

-

... More
Providing security fencing of size 2.4m x 3m x3m (total area 28.8 sqm) to Distribution Transformer structures with gate and locking arrangement which is one side removable and three sides fixed fencing using G.I. Chain link mesh 8 gauge 50.8mm x 50.8mm (2” x2”) size, MS angle 50 x 50 x 6, MS flat 35 x 6, MS flat 25x 6, bolts, nuts, Aldrop, hinges, concreting the supports with PCC (1:3:6), painting one coat red oxide, two coats synthetic enamel paint, complete for finished item of work . Whenever it is not possible to provide fencing of size 2.4mx3mx3m, then size may be reduced and payment shall be arranged based on the actual area. (LABOUR PORTION)

6537.6

-

-

... More
Conversion of LT S-Ph 3W line to LT 3-Ph 5 W line - LABOUR

-

-

-

... More
Erection of 8.0 M long 200Kg working load PSCC poles including pit excavation in all soils except which require blasting as per specification including transport, loading, unloading Charges complete

1126

-

-

... More
Erection of LT 3-Ph 5W cross arm ( 50x50x6 mm MS Angle ) with suitable back clamp made up of 50X6mm MS flat on already erected 8.0 Mtr. PSCC pole for 3-Ph 5W line with bolt & nuts and washers etc. including transport, loading, unloading Charges complete

6475

-

-

... More
Fixing of LT Pin Insulators with GI pins with double nuts & double washers on erected LT 3-Ph 5W cross arm complete

21395

-

-

... More
Fixing of LT Shackle Insulators with metal parts on erected LT 3-Ph 5W cross arm complete

5630

-

-

... More
Erection of LT Stay set complete including fixing of bow, fixing and binding of eye bolts, anchor roads, guy insulators and pit excavation in all soils except which require blasting as per specification including transport, loading, unloading Charges (excluding concreting)

1689

-

-

... More
Paving out 34Sq.mm AAA Conductor and stringing duly arranging temporary guys, jointing, clamping, jumpering, pin binding, tensioning and strain insulators binding etc., on the poles maintaining ground clearances as per specification including transport, loading and unloading charges including providing of double jumpers at cut point

920

-

-

... More
Dismantling of material for conversion of 6.3 lines to 11KV line

-

-

-

... More
Dismantling of 8.0 Mt PSCC Pole and transport to nearest Sub-Station point /any other location as instructed by the Engineer-in-Charge including transporting and loading, unloading charges

998

-

-

... More
Dismantling of existing 34 Sqmm Conductor of 6.3KV line and handing over to district stores including transporting and loading, unloading charges

71

-

-

... More
Dismantling of Top Cleat

998

-

-

... More
Dismantling of existing 1-Ph DTRs

-

-

-

... More
Dismantling of existing 1-Ph 16KVA or 15 KVA DTR with accessories and handing over to the District Stores including transport , loading & unloading charges

466

-

-

... More
Dismantling of material for conversion of LT S-Ph 3W line to LT 3-Ph 5 W line and handover the materials to Stores

-

-

-

... More
Dismantling of LT 1-Ph , 3WCross arms

3716

-

-

... More
Dismantling of LT Suspension clamp /dead end clamps with eye hook

2477

-

-

... More
Dismantling of LT S-Ph, 2X16+25 Sqmm AB Cable

10

-

-

... More
Disconnection & Re-Connection of Sservice Coonections

3728

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.