Public Works Department Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Public Works Department - PWD Tender
Housekeeping Services
Eprocure
Opening Date6 Feb 2024
Closing Date14 Feb 2024
Tender Amount₹ 16,27,353
Costs
EMD
₹ 32,547Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_APWD_13317_1Bid Award Id
ViewTender No
91/DB/CD-I/RGT/2023-24Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://apwd.and.nic.in/APWD/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
510
-
-
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
-
-
-
One or more coats on old work
249
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
-
-
-
25 mm nominal dia Pipes
65
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
-
-
-
20 mm nominal dia Pipes
10
-
-
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
2000
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.
-
-
-
Semi rigid pipe
32 mm dia
2
-
-
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:
-
-
-
White Vitreous china Orissa pattern W.C. pan of size580x440 mm with integral type foot rests
2
-
-
Providing and fixing brass bib cock of approved quality :
-
-
-
15 mm nominal bore
6
-
-
Providing and fixing brass stop cock of approved quality :
-
-
-
15 mm nominal bore
4
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm dia CPBrass single hole basin mixer of approved quality and make, includingpainting of fittings and brackets, cutting and making good the wallswherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a15 mm CP Brass single hole basin mixer
2
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
29
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
-
-
-
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
399
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
-
-
-
40 mm thick with 20 mm nominal size stone aggregate
38
-
-
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
16
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
41
-
-
Providing and fixing CPVC ball valve of approved quality:
-
-
-
25 mm nominal bore
2
-
-
Providing and fixing soil, waste and vent pipes with PVC pipe including jointing with seal ring leaving 10 mm gap for thermal expansion. (i) Single socketed pipes.
-
-
-
100 mm dia pipe
20
-
-
Providing and fixing PVC plain bend of required degree for PVC soil pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
-
-
-
100 mm dia
4
-
-
Construction of septic tank with CC wall in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) 20 cm thick including RCC pre-cast top slab 10 cm thick with CC 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) 20 cm thick foundation concrete 1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with water proof cement mortar 1:4 (1 cement: 4 fine sand) finished with floating coat of neat cement, 50 mm thick CC floring 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), including RCC baffle wall 10 cm and RCC slab cover and MS footrest for manhole at 30 cm c/c etc. complete as per design, drawing and direction of Engineer-in-charge.
-
-
-
25 users having inside dimention 2.10x1.20x1.60m including 30 cm free board.
1
-
-
Constructing cement concrete chamber 60x60x75 cm inside, in cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 40mm nominal size) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per the direction of Engineer-in-charge.
4
-
-
Providing and fixing PVC single equal plain junction of required degree for PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
-
-
-
100x100x100 mm
2
-
-
Supplying and fixing of mini /giant tyre fenders, making hole, cutting,bending and fixing of MS plate , GI nipples and flanges,washer,wire rope,wire grip cardium compound and accessories in position as directed by the Engineer-in-charge including cost of gaint tyre fenders MS plate, GI nipples, flanges, washers, wire rope, cardlum compound and accessories, cost of transportation charge of all materials to worksite,scaffolding charges,all labour charges, cost of minor tools etc. complete.
22
-
-
Lifting the raint / mini tyre the berthing face with the help of crane / forklift for replacing nipple flange, wire rope etc. complete and including cost of all labour charges and cost of minor tools etc. complete.
22
-
-
Evaluation Notes How It Works ?