Public Works Department Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Public Works Department - PWD Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date12 Jun 2024
Closing Date20 Jun 2024
Tender Amount₹ 43,46,701
Costs
EMD
₹ 86,934Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Extension Of Front Porch/balcony With Glass Panelling, Padauk Panel Claddings, Polishing Of Existing Cladding, Repair And Other Finishing Works Including Supply Of Furnitures Woods Laminate, Flooring For H-123 Type-v Bungalow At Megapode, Haddo Unde
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_APWD_14398_1Bid Award Id
ViewTender No
NIT No. 13/EE/PBND/2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://http://apwd.and.nic.in/APWD/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
2.42
-
-
... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
9.76
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
... More
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
10.28
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fllets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
-
-
-
... More
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
19.01
-
-
... More
Reinforced cement concrete work in beams, suspended foors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
23.42
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for
-
-
-
... More
Foundations, footings, bases of columns, etc. for mass concrete.
16.8
-
-
... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
96
-
-
... More
Suspended floors, roofs, landings, balconies and access platform
108
-
-
... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers
91
-
-
... More
Columns, Pillars, Piers, Abutments, Posts and Struts
55
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.
1524
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
-
-
-
... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.
2974
-
-
... More
Providing and laying Autoclaved Aerated concrete blocks (AAC) masonry 150mm/230mm/300 mm thick AAC with Grade-1 blocks of density 551-650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
4.8
-
-
... More
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
50.26
-
-
... More
Providing and fixing wooden laminate flooring consisting of individual pieces of 1286X194X8mm all jointed together and laid on the floor over a plastic sheet and 3mm PU foam sheet including providing matchking skirting all round and T-profile at all the door openings all complete as required and as per the direction of Engineer-in-charge.
77.4
-
-
... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
-
-
-
... More
12.5 mm thick tapered edge gypsum moisture resistant board
106
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift
57
-
-
... More
12 mm cement plaster of mix :
-
-
-
... More
1:4 (1 cement: 4 fine sand)
286
-
-
... More
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
-
-
-
... More
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm
392
-
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
392
-
-
... More
Providing and fixing stainless steel grade 304 curtain rod with two decorative type stainless steel brackets including extra supports at middle with necessary stainless steel screws wherever necessary etc complete as per the direction of Engineer-in-charge.
-
-
-
... More
25mm dia
48
-
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
-
-
-
... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
5.62
-
-
... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1
-
-
... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
-
-
-
... More
Of area 3 sq. metres and below
2
-
-
... More
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :
-
-
-
... More
Of sectional area 40 square centimetres and above
0.45
-
-
... More
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
41
-
-
... More
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
-
-
-
... More
For thickness of tiles 10 mm to 25 mm
51.48
-
-
... More
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
-
-
-
... More
G.S. Sheet
30.32
-
-
... More
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking within 50 metres lead :
-
-
-
... More
Thickness above 10 mm up to 25 mm
51.61
-
-
... More
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
25.35
-
-
... More
Providing and fixing 12mm thick with timber Cat-I(A) wall panelling on existing frames with necessary nails/screws etc complete as per the direction of Engineer-in-charge (Frame work to be paid separately).
49
-
-
... More
Providing and fixing wood work in frames of false ceiling, partition etc sawn and put up in position with
-
-
-
... More
Kiln seasoned and chemically treated superior hardwood cat-II (B)
0.28
-
-
... More
Providing and fixing ceramic heavy duty parking tiles of size 300x300mm (Thickness to be specified by the manufacturer) of 1st quality of approved make and colour on 20mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pignment etc. complete as per the direction of Engineer-in-charge
62
-
-
... More
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/ 120 no. and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)
49
-
-
... More
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately)
6.2
-
-
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
1600
-
-
... More
Providing and fixing 12mm thick frameless toughened glass for partition and walling and fixed in position in existing frame etc. complete as per the direction of Engineer-in-charge. (Cost of frame and beading shall be paid separetely).
116.54
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
... More
Two or more coats on new work
78
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
-
-
-
... More
Double charge vitrified tile polished finish of size
Size of Tile 600 x 600 mm
77.4
-
-
... More
Providing and fixing PVC weep hole.
-
-
-
... More
75mm dia PVC pipe
10
-
-
... More
Providing and fixing 6mm thick mirror of superior glass (of approved quality) and of required shape and size with wooden moulded frame of padauk wood cat-I(A) of size 100x40mm with 6 mm thick hard board backing :
-
-
-
... More
Size 2600x2600mm
1
-
-