Military Engineer Services Tender
... More
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date29 Mar 2025
Closing Date24 Apr 2025
Tender Amount₹ 4,24,000
Costs
EMD
₹ 8,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_699171_1Tender No
8142/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
All as per item 2 above but One socket out let 5/ 6 Amps point on the same board complete all as specified and as directed.
1
-
-
... More
All as per item 2 above but One socket out let 5/ 6 Amps point on the independent board complete all as specified and as directed.
2
-
-
... More
All as per item 2 above but for wiring with 2.50 Sq mm single core copper conductor for one socket out let 15/16 Amps point on the independent board complete all as specified and as directed.
2
-
-
... More
S&F in repairs switch socket combination 2 in 1, 5 Pin, 5/ 6 Amps, white ivory finish flush type complete all as specified and as directed.
2
-
-
... More
S&F for of switch socket combination outlet 2 in 1, 5 Pin 6/ 16 Amps multipurpose 230 Volt flush type complete all as specified and as directed.
2
-
-
... More
S&F for switch piano flush type 5/ 6 Amps single pole one way complete all as specified and as directed.
12
-
-
... More
S&F for switch piano flush type 15/ 16 Amps single pole one way complete all as specified and as directed.
2
-
-
... More
S&F for ceiling rose, bakelite, surface type, 220/ 240 Volts, three terminals complete all as specified and as directed.
4
-
-
... More
S&F for lamp holder, insulated body, with back plate suitable for batten/ angle fittings complete all as specified and as directed.
2
-
-
... More
S&F for plug top 15/ 16 Amps, insulated body, white colour complete all as specified and as directed.
2
-
-
... More
M&L for sub main wiring with 3 run of 4.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete including taking down old unseriveable complete all as specified and as directed
Note : (i) Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
8
-
-
... More
M&L for sub main wiring with 3 run of 6.00 Sqmm (nominal cross-sectional area) FRLSH PVC insulated unsheathed single core cable of working voltage 1100 Volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit including taking down old unseriveable complete all as specified and as directed
Note : (i) Three run of submain wiring cable along with 25 mm PVC conduit pipe shall be measured as one unit length.
8
-
-
... More
S&F sheet metal enclosure for 8 way distribution boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F sheet metal enclosure for 4 way distribution boards (DB’s), double door, single pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F sheet metal enclosure for 4 way distribution boards (DB’s), double door, triple pole and neutral with 200 Amps rated bus bar, IP-43 protection suitable for fixing MCBs/ isolators with and including blanking plates c including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F MCB TPN 40 Amps, 415 Volt, 10 kA, 'C' Curve rating, complete all as specified and as directed.
1
-
-
... More
S&F MCB, single pole and neutral 40 Amps, 240 Volts, ‘C’ curve, 10 kA complete all as specified and as directed.
1
-
-
... More
S&F MCB, single pole 5 Amps to 32 Amps, 240 Volts, ‘C’ curve, 10 kA complete all as specified and as directed.
10
-
-
... More
S&F energy efficient surface and wall mounted LED batten 18/ 20 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed.
15
-
-
... More
S&F energy efficient surface and wall mounted LED batten 2 feet, 9/ 10 Watts, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. Diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old tube light fitting complete all as specified and as directed.
2
-
-
... More
S&F energy efficient 2 feet x 2 feet LED light fitting 36 Watts with nano diffuser technology to ensure minimum loss in light transmitted, long life of over 30000 hours including taking down old unseriveable complete all as specified and as directed
Make: Crompton Cat No. LCTLRP-30-FO-CDL or equivalent in Bajaj/ Crompton.
6
-
-
... More
M&L for disconnecting of electric connection from ceiling rose and taking down the ceiling/ exhaust fan any type sweep for carrying out repairs / rewinding/ replacement/ cleaning etc and refixing the same in position after repairs including fixing/ labour only for replacement of unserviceable parts, greasing, oiling etc and replacement of minor rubber parts, connectors, bolts, nuts etc including replacing of unserviceable flexible connection wire etc upto 1 metre length complete all as specified and as directed. Note: - The new parts required shall be supply only under relevant items herein after and shall be measured and paid separately)
4
-
-
... More
M&L for rewinding of coils of ceiling fan of any make and sweep by following ways:- (i) Taking out complete coils from the rotor of ceiling fan (ii) Rewinding of ceiling fans of any sweep by using super enameled copper wire and turns as per existing gauge and approved quality including insulation paper, varnishing, drying and refitting the ceiling fan and testing the speed complete all as specified and as directed.
2
-
-
... More
All as per item No. 26 here-in-above, but of exhaust fan of sweep 250 mm to 450 mm complete all as specified and as directed.
2
-
-
... More
Supply only following parts/ components of ceiling fan existing make and size complete all as specified and as directed. (Note: Parts and components supplied under this item shall be fixed under items herein before) :-
(a) Gun metal bush bearing
2
-
-
... More
(b) ball bearing complete all as specified and as directed.
2
-
-
... More
(c) capacitor 2.5 MFD complete all as specified and as directed.
3
-
-
... More
S&F step type electronic fan regulator, AC, 230 Volts, including taking down old unserviceable fan regulator complete all as specified and as directed.
2
-
-
... More
Supply only following parts / components of exhaust fan of existing make and size complete all as specified and as directed :- (a) Gun metal bush bearing
1
-
-
... More
(b) ball bearing complete all as specified and as directed.
1
-
-
... More
(c) capacitor 4 MFD complete all as specified and as directed. Make : USHA/SARDA/KELTRON/UNIVERSAL.
2
-
-
... More
M&L for painting of ceiling fans in situ with one coat of synthetic enamel paint by spraying including filling cavities with filler, after cleaning dust etc complete all as specified and as directed.
10
-
-
... More
EXTERNAL ELECTRIC SUPPLY
Excavation in trenches not exceeding 1.50 mtr wide and not exceeding 1.50 mtr deep and getting it out in soft/loose soil including forming bottom surface to required level for laying pipes/ cables and water pipe lines complete all as specified and as directed.
25
-
-
... More
Returning, filling in excavated soil including spreading, leveling, watering, well ramming in layers not exceeding 25cm complete all as specified and as directed.
23
-
-
... More
Removing the surplus excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50 mtr above starting point complete all as specified and as directed.
2
-
-
... More
Supplying, Laying & connecting cable 1100 Volts grade, aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-I) amended upto date including taking out old existing cable complete all as specified and directed of following sizes:-
Note : Earthwork excavation , GI protcetion pipe shall be measured and paid separately in their respective items.
-
-
-
... More
10 sqmm X 4.0core
35
-
-
... More
16 sqmm X 4.0 core
35
-
-
... More
25 sqmm X 3.5 core
15
-
-
... More
35 sqmm X 3.50 core
15
-
-
... More
50 sqmm X 3.50 core
15
-
-
... More
95 sqmm X 3.50 core
15
-
-
... More
Supply and laying DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 145mm and inner dia 126mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed.
20
-
-
... More
Supply and laying DWC (Double Wall Corrugated) HDPE pipe, ISI marked IS 14390 Part-II, of outer dia 50mm and inner dia 38mm with smooth internal and profiled external surface for non pressure underground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed.
80
-
-
... More
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 16 to 35 Sqmm, indoor/ outdoor type complete all as specified and as directed.
1
-
-
... More
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 50 to 95 Sqmm, outdoor type complete all as specified and as directed.
1
-
-
... More
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core/ 4 core XLPE, armoured aluminium conductor cable of size 240 Sqmm, outdoor type complete all as specified and as directed.
1
-
-
... More
M&L for painting of street light poles, by removing of old paint and applying one coat of red oxide metal primer and two coats of approved aluminium paint on steel tubular swaged pole, cross arms and service brackets complete all as specified and as directed.
12
-
-
... More
M&L for painting of RCC pole by two coats of cement based paint complete all as specified and as directed.
4
-
-
... More
Taking down LED street/ flood light fittings, post top lantern and bollard light of any size complete all as specified and as directed.
6
-
-
... More
S&F in repair/replacement of new generation energy saving and environmental friendly 35 Watts street light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F in repair/replacement new generation energy saving and environmental friendly 120 Watts flood light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F in repair/replacement new generation energy saving and environmental friendly 200 Watts flood light fitting long life versatile pressure die-cast aluminium IP66 road way luminaire with high power LEDs as light and electronic driver including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F in repair/replacement post top lantern fitting LED type of size 1x10 Watts with IP 65 protection, Resistant to impact and corrosion, moon light effect and eficient light distribution including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F LED bollard light fitting 1x14 Watts with IP 65 protection of neutral white colour in die-cast housing and Polycarbonate diffuser cover on base plate mounting with operating voltage 140-270 V, AC, 50 Hz, including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
Taking down the LED street/ flood lights/ bollard lights of any type/ size from its existing position, replacing new driver and refixing the light fitting in its original position complete all as specified and as directed. .
6
-
-
... More
S&F in repair driver suitable for 35 Watts LED security light fitting long life versatile pressure die-cast aluminium IP66, including taking down old driver complete all as specified and as directed. Make: Crompton /Bajaj/ Havells.
1
-
-
... More
S&F in repair driver suitable for 120 Watts LED flood light fitting long life versatile pressure die-cast aluminium IP66, including taking down old driver complete all as specified and as directed.
1
-
-
... More
S&F in repair driver suitable for 200 Watts LED flood light fitting long life versatile pressure die-cast aluminium IP66, including taking down old driver complete all as specified and as directed.
1
-
-
... More
S&F in repair driver suitable for post top lantern fitting LED type of size 1x10 Watts with IP 65 protection, Resistant to impact and corrosion, moon light effect and eficient light distribution complete all as specified and as directed. Make: Philips /Bajaj/ Havells.
1
-
-
... More
S&F in reoairdriver of bollard/garden light fitting LED type of size 1x40 Watts with IP 65 protection, resistant to impact and corrosion, moon light effect and efficient light distribution complete, including taking down old driver complete all as specified and as directed.
1
-
-
... More
S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 139 x 119 x 70 mm (internal dimensions) comprising 2 Nos aluminium busbar of adequate capacity including suitable size MS clamps all as directed, including taking down old unserviceable junction box complete all as specified and as directed.
1
-
-
... More
S&F LT Junction box for street lights, Sheet Moulding Compound (SMC), hinged door type and locking arrangement, off white colour of size 240 x 140 x 95 mm (internal dimensions) comprising 4 Nos aluminium busbar of adequate capacity including suitable size MS clamps all as directed, including taking down old unserviceable junction box complete all as specified and as directed. Make: Sintex cat part No. GSJB 2817 or equivalent.
2
-
-
... More
S&F MCCB 4 Pole, 415 Volt, 100 Amp with breaking capacity 16 kA, rating with thermal magnetic protection unit complete including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F MCB 4 Pole, 415 Volt, 32 Amp with breaking capacity 10 kA, rating with thermal magnetic protection unit including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
S&F MCCB 4 Pole, 415 Volt, 63 Amp with breaking capacity 16 kA, rating with thermal magnetic protection unit complete including taking down old unseriveable complete all as specified and as directed
1
-
-
... More
M&L for wiring with 1100 Volt grade, 2 runs of 1.5 Sqmm single core FRLSH PVC insulated unsheathed multi stranded copper conductor cable drawn through rigid PVC conduit from street light in box/ looping box to street light fitting along with 1.5 Sqmm single core FRLSH PVC multi stranded copper conductor cable green in colour as continuous earth wire complete all as specified and as directed.
10
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (each pit not less than 2.25 mtr below ground level) with Top edge of earth plate not less than 1.5 mtr below normal ground level, including provision of galvanised earth strip 32x6 mm connected by means of bolts, nuts, check nuts and washers of galvanised iron steel, provision of 40mm dia GI pipes medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 15 mm dia GI pipe perforated medium grade for watering arrangement and PCC 1:3:6 type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 for earth pit. Cover with 6 No's 8 mm dia high strength deformed steel TMT bars on both ways, including test terminal block made of gun metal or phosphorous bronze 75x75x25 mm and drilled and screwed including 3 nos 8 mm dia, 25 mm long at hex head screw also necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance not exceeding 50 mtr, provision of char coal and salt complete all as shown in electrical plate No. 3 of schedule Part-I 2009 all as specified, directed and Testing on completion, including taking down old unserviceable earthing complete all as specified and as directed.
1
-
-
... More
M&L for painting of LT panel of any type (indoor/ outdoor) by removing of old paint and applying one coat of red oxide metal primer and two coats of approved synthetic enamel paint to LT panel complete all as specified and as directed.
2
-
-
... More
M&L PCC 1:2:4, type B1 (using 20 mm graded crushed granite stone aggregate) as in coping complete all as specified and as directed.
0.3
-
-
... More
EXTERNAL WATER SUPPLY Taking up or down steel tubing/PPR pipe and connections Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
6
-
-
... More
S&F for 40 mm bore dia. medium grade GI tubing with all fittings like bend, elbow etc fixed to wall/ ceiling or laid in ground including Taking up complete all as specified and as directed.
6
-
-
... More
S&F for 25 mm bore dia. Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe including taking down old unserviceable complete all as specified and as directed.
1
-
-
... More
Ditto as per item no above but size 40 mm bore dia Ditto
1
-
-
... More
S&F for 20 mm bore PTMT ball valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed including taking down existing old ball valve complete all as specified and as directed.
1
-
-
... More
M & L for cleaning and removing all scale and dirt etc, from tanks and from mouths of circulating pipes of tank capacity 500 ltrs complete all as specified and as directed.
2
-
-
... More
M&L for cleaning of over head water storage tank capacity not exceeding 25,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door complete all as specified and as directed.
1
-
-
... More
M&L for cleaning of semi underground water storage sump of capacity not exceeding 20,000 ltrs by removing mud, silt, cutting of grass, roots and pumping out waste water, scrapping with wire brush, spreading bleaching powder, drying of tank and refilling fresh water including repairs to the opening door and outside painting to semi UG sump as per existing colour scheme complete all as specified and as directed.
1
-
-
... More
M&L for taking down existing water supply pumping set centrifugal/ monoblock type of capacity 7.5 HP by dismantling from existing connections of any make or model complete for servicing, cleaning, greasing, minor repairing including repairing/ replacement of bearings, shaft, motor capacitors, replacing rusted bolt-nuts-washers and re-assembling after testing & reconnecting for smooth running complete all as specified and as directed.
1
-
-
... More
S&F for brass foot valve of size 50 mm including removing the existing unserviceable foot valve complete all as specified and as directed.
1
-
-
... More
S&F for three phase fully automatic DOL starter suitable for 7.5 HP centrifugal pump set complete all as specified and as directed. Make: L&T or equivalent make of Standard/ Havells.
1
-
-
... More
M & L for laying DI pipe with spigot and socketed ends, class K-7 in any length all as per IS 8329/2000 with blue epoxy coated with suitable rubber tyton joint complete for 80mm dia pipe complete all as specified and as directed.
6
-
-
... More
COOLING APPLIANCES
M&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R 134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 40/80 Ltrs capacity water coolers complete all as specified and as directed.
1
-
-
... More
M&L for cleaning including cleaning the system, flushing through with CO2/N2 removal of complete dirt, oil brazing the line, pressure testing, rectification of leakages, dehydrating, vacumising, charging of R-12/R-22 gas, replacement of copper pipe, copper strainer, topping up compressor oil, testing & commissioning the water coolers of capacity 40/80 Ltrs complete all as specified and as directed.
3
-
-
... More
S&F in repairs relay assembly suitable for water cooler of any capacity as per existing complete all as specified and as directed. (Make : Sriram / Sarada)
1
-
-
... More
S&F in repairs thermostatic switch suitable for water cooler of any capacity as per existing complete all as specified and as directed. (Make: Indofoss / Ranutrol)
1
-
-
... More
S&F in repairs capacitor suitable for water cooler of any capacity as per existing complete all as specified and as directed. (Make : Sarada / Unistar)
1
-
-
... More
S&F in repairs overload protector suitable for water cooler of any capacity as per existing complete all as specified and as directed. (Make : Sriram / Kirloskar)
1
-
-
... More
S&F in repairs fan motor with fibre blade suitable for water cooler of any capacity complete all as specified and as directed. (Make : AUF / Freeflow)
1
-
-
... More
S&F in repairs PVC hose connections, for water out let pipes including fixing by proper clips complete all as specified and as directed.
1
-
-
... More
S&F in repairs PVC float valve of 15mm bore (including ball) suitable for water cooler of any capacity as per existing complete all as specified and as directed.
1
-
-
... More
S&F in repairs capillary tube including brazing for water cooler of any capacity complete all as specified and as directed.
1
-
-
... More
S&F in repairs wiring kit for water cooler of any capacity complete all as specified and as directed.
1
-
-
... More
AC & REFRIGIRATION
M&L for taking down defective sealed compressor from the unit and supply and fix factory reconditioned compressor obtained for the exchange of old compressor including cleaning the refrigeration circuit with appropriate cleaning agent flushing through with CO2/N2, brazing the line, pressure testing rectification of leakages, dehydrating, vacumising, charging of R134A gas, replacement of copper pipe, copper strainer, topping up compressor oil including to and fro transportation of the unit to the workshop testing & commissioning of 165 ltrs capacity. Make: LG / Whirlpool / Usha (Tecumsha)
1
-
-
... More
M&L for taking down the AC unit of any capacity by disconnecting all electrical and piping connections and performing following maintenance tasks:-
4
-
-
... More
(a) Removal of dust from the outer body with the help of a blower.
(b) Cleaning the condenser coils with water and cleaning agent/soap solution and decaling it.
(c) Painting the base tray with one coat of black enameled paint.
(d) Cleaning of air filter of with vacuum cleaner or washing the filter in lukewarm water with detergent.
(e) Cleaning of anti allergy and triple filter and drying the filter in direct sunlight for 2 hrs.
(f) Cleaning of plasma filter with vacuum cleaner or washing the filter in lukewarm water with detergent and drying the filter in shade.
(g) Cleaning of micro protection filter with vacuum cleaner only.
(h) Cleaning of indoor unit with a soft, dry cotton cloth.
(j) Checking all connections including functioning of relays, capacitors, overload protectors, thermostats, industrial socket (Metal clad) and circuit breaker.
(k) Refixing all items and making it serviceable.
Note: All new parts shall be measured and paid separately.
-
-
-
... More
M&L for taking down the AC unit of any capacity (both indoor & outdoor units) by disconnecting electrical connections and piping, shifting to new location and reinstalling with necessary additions/ alterations, fittings and fixtures, making good the disturbed surfaces complete all as specified and as directed.
1
-
-
... More
S&F for copper pipe line heavy duty upto 5/8" dia with puff insulation and flair nuts from indoor to outdoor split type AC of 1.5/2 TR capacity complete all as specified and as directed.
4
-
-
... More
S&F in repairs of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 45/4.0 mfd complete all as specified and as directed.
1
-
-
... More
S&F in repairs of capacitor (conforming to IS:2993-1975) AC 230 Volts in plastic container 55/6.0 mfd complete all as specified and as directed.
1
-
-
... More
S&F in repairs condenser unit complete set suitable for 1.50 Ton split type AC unit including removing the existing unit complete all as specified and as directed.
1
-
-
... More
S&F in repairs fan blade suitable for 1.50 Ton split AC complete all as specified and as directed.
1
-
-
... More
S&F in repairs blower motor capacitor complete all as specified and as directed.
1
-
-
... More
S&F in repairs remote with holder suitable for split type ACs complete all as specified and as directed.
1
-
-
... More
S&F in repairs swing motor as per existing model/ make for split type AC 1.5/ 2 TR complete all as specified and as directed.
1
-
-
... More
M&L for disconnecting and taking down burnt compressor of capacity 1.5 TR from split AC unit and supply and install the new compressor 1.5 TR capacity duly filled with gas as per existing model and size and testing also complete all as specified and as directed. Make:- LG / Voltas. Note:- Guarantee card with original purchase voucher of the original manufacturer shall be produced before payment.
1
-
-
... More
S&F in repairs PCB Board suitable for 1.5 Ton split AC complete all as specified and as directed.
1
-
-
... More
Supply and charging of refrigerant gas R-22/ R134A/ R32 in cooling appliances after dehydration all as per standard practice testing for proper cooling effect and satisfactory performance complete all as specified and as directed. Make : Mafron / Floron
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%