Military Engineer Services Tender

... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Special Repairs To Bldg No. P-46 At Mo Under Ge Haddo, Sri Vijaya Puram in South Andaman, Andaman & Nicobar Islands, with an estimated contract value of Rs. 48,27,000. The bid opening date for this tender is 01-05-2025 and the last date for bid submission is 29-05-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date1 May 2025
Closing Date29 May 2025
Tender Amount₹ 48,27,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.

5

-

-

... More
S & F in replacement of LED tube of cap 20 watt, 4' long suitable for flame proof light fitting installed at any position re-fixing of the same after replacing the tube all as specified and directed by Engr In Charge.

12

-

-

... More
Demolition of reinforced cement concrete of any description as in pillar,chajja/facia etc and in any position not otherwise specifically provided for incl cutting reinforcement carefully without disturbing the existing structure complete all as specified and directed

0.48

-

-

... More
Dismantling plain or corrugated steel sheeting, any gauge, thickness including nainital or similar pattern in roof coverings complete all as specified and directed

857

-

-

... More
Material and labour for Fabricating and fixing for exhaust fans Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 all as specified and directed.

80

-

-

... More
Supply and fixing in replacement of Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw.

8

-

-

... More
M&L Reinforced cement concrete (nominal mix) Type B1 1:1.5:3 20 mm graded aggregate in Columns, pillars, piers, posts and struts complete all as specified and directed

1.5

-

-

... More
M&L Formwork flat to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface complete all as specified and directed

20

-

-

... More
M & L PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) 100 mm thick as in sub-floor,finish the top surfaces even and smooth without using extra cement complete all as specified.

360

-

-

... More
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 50 mm (OD) x 38 mm (ID) along with connected accessories like couplers .bends ,end caps etc. for LT cable protection all as specified and directed.

34

-

-

... More
S&F flame proof switch socket with termination chamber made of die cast aluminium, alongwith 01 x plug top, double pole 16A, 250V all as speciifed and directed by Engr In Charge. Make : Sudhir Cat.No.- SS/2C/2021 or equivalent in Bajai/ crompton Greaves.

5

-

-

... More
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium wire staples all as specified and directed

20

-

-

... More
S&F double layer rotational moulded PVC water storage tank cylinderical, vertical with closed top hoisted and fixed in position tank capacity 2000 Ltr with and including PTMT float valve 20mm dia and making connection for inlet and outlet complete all as specified and directed

1

-

-

... More
Taking down Chowkats exc 1.5 Sqm but n. exc 4 Sqm each with shutters (Without taking off shutters from the frame) complete all as specified and directed

2

-

-

... More
S&F for 110mm dia PVC (SWR) grade single socketed pipes in any length complete with rubber ring joints fixed to wall etc using synthetic rubber adhesive cement solvent complete all as specified.

40

-

-

... More
S & F in replacement of SS Enclosure including MCCB 160 to 250 Amps MCCB, 4 pole, 25 KA , 415 V, IK08 and IP30 Protection and with connected fixing accessories with Wall/ panel/ pole etc as specified and directed by Engr In Charge. Make:- L & T model No CM90996OOOO or equivalent in Indo Asian/ Havells.

1

-

-

... More
M&L for removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed

5

-

-

... More
S&F multi wall poly carbonate sheet 4 mm thick with required side lap fixed in position on steel frames as in roof covering with required screws etc., in wall cladding at roof level complete all as specified and as directed.

140

-

-

... More
M&L aluminium wind tie of any size fixed with self tapping screws of size 50/75mm with integral EPDM washer in roof covering all as specified and directed

280

-

-

... More
S&F 1.25mm thick,Mild steel plain sheeting,covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required

11

-

-

... More
M&L Reinforced cement concrete (nominal mix) Type B1 1:1.5:3 20 mm graded aggregate in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed

2

-

-

... More
M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified

84

-

-

... More
Supply only liquid water proofing compound

7

-

-

... More
M&L Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundations or mass concrete complete all as specified and as directed

0.6

-

-

... More
S & F FLP rotary switch with cable termination box in LM (jone switch for 2/3 LP) 16 Amps double pole on/off 250 V all as speciifed and directed by Engr In Charge. Make : Sudhir cat No RI/2C/2021 or equivalent in Bajai/ crompton Greaves.

46

-

-

... More
Taking down of flameproof light fittings of any size/ cap from any position.

30

-

-

... More
Dismantling of 110mm dia cast iron/PVC pipes incl bends/branch pieces jointed in cement mortar and taking out if reqd.

20

-

-

... More
M &L for Mild steel TMT bars 5mm dia over upto and including 10mm dia in stirrups, spacers and binders, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.

30

-

-

... More
Labour for re-installation of existing flameproof light (retrived from Item No-55) of any cap all as specified and directed .

20

-

-

... More
Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed.

12

-

-

... More
Excavation in post hole in hard/dense soil (or similar holes) each n. exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, watering, and removing surplus soil to a distance n. exc 50m and making good surface complete all as specified and directed

15

-

-

... More
M&L formwork for rough finished flat surface to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed

7

-

-

... More
M & L for hardcore of gauge n exc 63 mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface of broken stone or boulders omplete all as specified and as directed.

5.55

-

-

... More
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed

32

-

-

... More
S & F Sub main wiring with PVC insulated FRLS cable 2 runs single core 1.5 sq mm 1100 V grade with stranded copper conductor cable using proper colour coding Phase Red /Yellow /Blue, Neutral- black and earth- green in and including stove enameled steel conduit of suitable size with all accessories required for flame proof wiring such as FLP bends elbow, unions, plug, juction box, flexible connecting pipe, glands etc surface type in wall/ceiling/floor/roof etc provision of PVC insulated FRLS copper conductor single core cable of same size but green in colour as continuous earthing wire for point wiring of flame proof light fittings all as specified and directed. Note : 3 runs of cable and one run of conduit shall be measured as one unit

357

-

-

... More
M&L for PCC (1:3:6) type C-2 (40 mm graded aggregate) 75mm thick as in plinth protection with even and smooth finishing without using extra cement complete Including filling the joints with mastic compound all as specified and directed

60

-

-

... More
S & F rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates Fe 410-w(Gde-E-250 ) quality A complete all as specified and as directed.

2250

-

-

... More
M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed

180

-

-

... More
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed

60

-

-

... More
Taking down of unsv flame proof exhaust fan of cap 380 mm sweep of any make from its existing position and servicing including PVC sleeves lead wires, bearings etc painting, testing and re-fixing in existing position of exhaust fan complete all as specified and as directed. (NOTE :- The brunt motor should be rewinded and the same will be measured and paid separately under relevant item of BOQ)

10

-

-

... More
S&F for 110mm dia PVC (SWR) bends with acess door any radius complete all as specified.

4

-

-

... More
S&F sheet glass 4 mm thick ordinary quality and glazing with aluminium glazing clip in aluminium window/ventilator shutter not exc 0.5 Sqm in each pane complete all as specified and directed.

20

-

-

... More
M&L Flame proof point wiring complete as specified with 1100 volts grade 1.5 sqmm and using same size earth continuity conductor two single core PVC insulated unsheathed cable using proper colour coding Phase Red/Yellow/Blue, Neutral- black and earth- green (FRLS) 1100 volts grade conforming to IS -694 with standrded copper conductor in and including stove enameled steel conduit with all accessories required for flame proof wiring such as FLP bends elbow, unions, plug, juction box, flexible connecting pipe, glands etc surface type in wall/ceiling/floor/roof etc, sunk pressed steel or cast iron flame proof terminal boxes including 1.5 sqmm PVC insulated stranded copper conductor earth wire connected to common earth dolly for 5 pin switch socket outlet , 5/6 Amps on independent board.

5

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed

99

-

-

... More
Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in hard/dense soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed

7

-

-

... More
M&L for cement concrete 1:2:4 type B1 (Using 20mm graded stone agrregate) as in foundation of posts, railing and similar work complete all as specified and directed

7.68

-

-

... More
M&L for returning filling in hard/dense soil including spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed

2

-

-

... More
Taking down old unsv sub main wiring of any size.

357

-

-

... More
S & F FLP die cast alluiminum alloy bulk head fitting , of cap 45 watt including connecting with copper conductor FRLS 1100 volts grade conforming to IS 694 to the fitting complete all as specified and directed . Make:-Sudhir cat No. BH / 124 / 45 or equivalent in CG/ Bajaj. Note: The rate shall be including necessary fitting arrangment for light fitting on ceiling/ wall.

6

-

-

... More
Supply and fixing in replacement of Air termination, single pointed aluminium rod 12mm dia and 300mm long.

18

-

-

... More
M & L for rewinding of unsv flame proof exhaust fan of cap 380 mm sweep of any make by super enamelled copper winding wire of suitable gauge and size with Garware insulating paper, insulating varnish and oven drying for requisite insulation values including necessary and testing after assembling in position complete all as specified and as directed.

4

-

-

... More
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of average 1mm thick wall care putty to make the surface smooth complete all as specified and directed

84

-

-

... More
S&F for 110mm dia PVC (SWR) bends any radius complete all as specified.

8

-

-

... More
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed

83.5

-

-

... More
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth wire 4 MM Dia as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 451 & 452 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.

1

-

-

... More
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32 mm x6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh, RCC cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land , filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 451 & 452 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.

8

-

-

... More
Taking down chowkhats or frames area n. exc 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed

32

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core. Complete all as specified and directed.

38

-

-

... More
Supply and fixing in replacement of Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.

214

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, fixed with self tapping screws all as specified and directed

67

-

-

... More
Dismantling PVC water tanks exc 1000 Ltr but n. exc 2000 Ltr capacity and removing to store complete all as specified

1

-

-

... More
S&F mild steel roof trusses (framed), trrussed, purlins, crane gantries, rails and fastenings and heavy bracket framming (Beam,Tee, Angle, Channels or flat sections) including distance pieces, cleats etc conforming to Fe 410-W (Gde-E-250) quality-A complete all as specifed and directed.

6500

-

-

... More
M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 all as specified

12

-

-

... More
M&L for 100mm thick PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in sub base/Ramp, finish the top surfaces even and fair complete all as specified and as directed

100

-

-

... More
M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface fair and even without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid separately)

180

-

-

... More
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed

1150

-

-

... More
S&F Anodised aluminium grill of approved pattern cut to required size/shape and fixed with position with aluminium bedding & frame with & including F sections, fixed to aluminium windows/ventilators complete all as specified and directed.

60

-

-

... More
Supply and fixing in replacement of Galvanised iron strip 32 x 6mm buried in ground.

98

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed

650

-

-

... More
S&F for 22mm wide of glass dividing strip,3mm thick inserting in position,conforming to design complete all as specified and as directed

240

-

-

... More
M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in sub base, finish the top surfaces even and fair complete all as specified and as directed

430

-

-

... More
M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed

450

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.