Military Engineer Services Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Military Engineer Services - MES Tender
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date5 Sep 2024
Closing Date4 Oct 2024
Tender Amount₹ 24,00,000
Costs
EMD
₹ 48,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666731_2Bid Award Id
ViewTender No
80335/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Microprocessor based controller for generator set monitoring, metering and control system with LED display, AMF function, electronic governor. Engine metering : Oil pressure, engine temperature, stanting battery volltage, engine running hours, AC Alternator metering : L-L voltage, and L-N voltage, current, KVA, frequency, kwh, PF etc. Engine Protection :- Low lube oil pressure high/ low/ weak coolent temperature, battery high/ low/ weak volts, fail to crank/ start sensor failure, cranking lockout, low fuel level. AC alternator protection :- over/ under voltage, over/ under frequency, loss of AC sensing, over speed, over current, KW overload.
-
-
-
Civil Works:- (i) As per manufacturer's instruction, All type of civil work like foundation, base plate with anti-vibration pad of ISI marked engine and alternator and shock vibration absorption material including PCC plateform (1:2:4) type B-1 using 20 mm graded aggregate and brick work in CM 1:4 all around the foundation including finishes all as directed by Engineer -in -charge for resting of DG set and sound proof enclosures. (ii) Rates of PCC Foundation are deemed to be included in quoted rates. Note:-
(i) DG Set as mentioned in item Ser No 01 along with Alternator, Control & Meeting Circuit and AMF Panel with detailed technical specification, wiring, circuit diagram duly indicating various spares (makes/ capacity) along with bill of materials will be got approved from the Accepting Officer before placing order to the firm.
-
-
-
M&L for earthing complete with galvanized iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground [earth pit not less than 2.25 meters deep below ground level] with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade and connected to pole structure / panel board/earthing test point all as shown in electrical plate No. 3 of SSR Part-I [2009] and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 50mm thick RCC 1:2:4 mix type B1 using 20mm graded stone aggregate, cover reinforced with 8mm dia TMT bras 150mm C/C both ways, GI funnel with watering pipe 40mm dia, wire mesh, protection pipe, earth strip up to 7.50m long, complete in addition to item No. 1 [a] to [e] of preamble [Notes] under sub heading earthing, specified in SSR Part-II.
6
-
-
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 185 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
60
-
-