Indian Army Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Indian Army Tender
Machinery and Tools
GEM
Opening Date23 Aug 2024
Closing Date13 Sep 2024
Tender Amount₹ 15,91,900
Costs
EMD
₹ 31,838Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
GEM/2024/B/5314515Bid Award Id
ViewTender No
GEM/2024/B/5314515Tender Authority
Indian Army ViewPurchaser Address
-Website
http://bidplus.gem.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
dcs_ot_dhanvantari_em_and_br_2024-08-22-10-10-38_fa7fb10045895b10348eebe28e96213a.pdf
boq_item_sample_file2_2024-08-22-10-10-38_9ba2dab2708d48213a8707f6ae151f76.csv
BOQ Items
Hermetic sealed Scroll , Hermetic sealed Scroll compressor of capacity 11 TR Model No - SH140 suitable for operation on 3 phase, 415 volts, 50 Hz AC Make Danfoss/Copeland / Emerson
Note The Contractor shall submit TC and warranty certificate for compressor before claiming payment
3
-
-
3 Pole power contactor , 3 Pole power contactor 3 Phase 415 V 32 to 40 Amps rated or suitable all per existing
2
-
-
Strip heater , Strip heater of rating 3.0 KW with finned tubular air heating elements filled with best quality MGO powder, stainless steel-304 sheathed with GI fins and 80/20 Nichrome wire Make Daspass or equivalent
30
-
-
gas R 410A , Supply and charging refrigerant gas R 410A for gas charging complete one time for topping up or making full qty as per the pressure requirement of plant and /testing for any leakage and rectifying the same as directed by Engineer in Charge and testing on full load condition for 8 Hrs period. Make Mafron/ Freon/ Floron
61
-
-
compressor oil , Supply only compressor oil for carrying out repairs under relevant items above Make SERVO/ Sheetal N-68 /Sandon/Equivalent
40
-
-
false ceiling , M/L for removing false ceiling carefully, keeping it in safe custody for refixing, dismantling GI duct sheet from ceiling suspended indoor unit of 3400 CFM capacity, strip opening defective duct heater with wiring complete and supply, install, testing and commissioning of Duct heaters of capacity 9.0 KW suitable for duct size all as per exisiting with air flow sensor, humidy state/ thermostat digital with controls/control wiring complete including any modification required for existing ducting including duct joints/sealant etc complete.
Note As Per PDF File att
1
-
-
defective GI tray , M&L for replacement of defective GI tray made out of 22 guage GI shet as per existing size for collecting condensed water of indoor unit with necessary UPVC (SCH40) pipe of dia 25 mm along with all connected fittings and accessories from GI tray outlet to outside of the room complete all as specified and as directed.
3
-
-
erection of GI sheet with TDF 22 Guage , M&L for taking down and supply, assembly and erection of GI sheet with TDF flange rectangular/ square duct made out of L shaped hallow profile, duly factory boxed including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints complete or any other shape as per site requirement of following sizes (a) 22 Guage
2
-
-
erection of GI sheet with TDF 24 Guage , M&L for taking down and supply, assembly and erection of GI sheet with TDF flange rectangular/ square duct made out of L shaped hallow profile, duly factory boxed including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints complete or any other shape as per site requirement of following sizes (b) 24 Guage
2
-
-
25 mm thickness insulation , M&L for fixing in repair defective duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and
including the following
As per PDF File att
5
-
-
40 mm thickness insulation , M&L for fixing in repair defective duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and
including the following (b) 40 mm thickness insulation
5
-
-
Touch screen Surgeon , Dismanlting old defective surgeon control panel, Supply, Install, Testing and Commissioning of Touch screen Surgeon control panel including of all fittings & fixtures complete, mounted flush in the operation theatre wall along with Distribution board provided to allow access to the panel for maintenance. Each control panel consists of following
Day time digital clock 01 Elapsed time digital clock 01 Hands free telephone 01 Medical Gas Alarm 5 gas
Temperature & Humidity display standard Clock 01 MAKE JK DIGILINE MARS STERILE SOLUTION
1
-
-
UPS of capacity 05 KVA , M&L for carrying out inspection, checking, repair and rectification of IGBT based UPS of capacity 05 KVA comprising of the following outlined services (a) Inspecting the UPS for serviceability/ functionality of components in UPS. During this the system shall be cleaned and general performance will be checked including inspection of all spare parts such as IGBT, Drive cards, relay cards, AC capcitors, inverter cooling fan, ceramic fuses and including replacing the defective spares if any complete, re-assembling, calibration of UPS complete and testing & commissioning complete all as specified and as directed. B, C , & D As per PDF File att
2
-
-
AC DC Capacitor , Supply only the following spares for carrying out repairs to UPS of capacity 5 KVA
(a) AC DC Capacitor (bal detail as per PDF file)
1
-
-
IGBT , Supply only the following spares for carrying out repairs to UPS of capacity 5 KVA (b) IGBT
2
-
-
Isolation feed back transformer , Supply only the following spares for carrying out repairs to UPS of capacity 5 KVA (c) Isolation feed back transformer (bal detail as per PDF file)
1
-
-
12 V 42 AH SMF Batteries , Supply only the following spares for carrying out repairs to UPS of capacity 5 KVA (d) 12 V 42 AH SMF Batteries (bal detail as per PDF file)
4
-
-
CPVC tubing , Taking down 15mm Steel /16mm CPVC tubing and connections complete all as specified and as directed
32
-
-
CPVC tubing 20mm , Taking down 20mm Steel / CPVC tubing and connections complete all as specified and as directed
26
-
-
32mm Steel CPVC tubing , Taking down 25mm or 32mm Steel / CPVC tubing and connections complete all as specified and as directed
42
-
-
CPVC pipes 20 mm , Supply and fixing of CPVC pipes 20 mm dia outer bore SDR 11 plain CPVC SDR 11 fittings on walls /ceilings or laying in floors including clamps etc complete all as specified.
32
-
-
CPVC pipes 25mm dia , Supply and fixing of CPVC pipes 25mm dia outer bore SDR 11 and plain CPVC SDR 11 fittings on walls /ceilings or laying in floors complete all as specified.
26
-
-
CPVC pipes 32mm dia , Supply and fixing of CPVC pipes 32mm dia outer bore SDR 11 and plain CPVC SDR 11 fittings on walls /ceilings or laying in floors complete all as specified.
16
-
-
CPVC pipes 40mm dia , Supply and fixing of CPVC pipes 40mm dia outer bore SDR 11 and plain CPVC SDR 11 fittings on walls /ceilings or laying in floors complete all as specified.
26
-
-
20 mm Brass Elbow , S&F 20 mm Brass Elbow (As per PDF file attach with BOQ)
20
-
-
0 mm Brass Elbow reducer , S&F 20 mm Brass Elbow reducer(3/4 x 1/2) (As per PDF file attach with BOQ)
25
-
-
Male Brass Threaded Adaptor , S&F Male Brass Threaded Adaptor (MTA/MBTA) 20mm bore (As per PDF file attach with BOQ)
30
-
-
Male Brass Threaded Adaptor , S&F Male Brass Threaded Adaptor (MTA/MBTA) 25mm bore (As per PDF file attach with BOQ)
15
-
-
Female Brass Threaded Adaptor , S&F Female Brass Threaded Adaptor (FTA/FBTA) 20mm bore (As per PDF file attach with BOQ)
18
-
-
Female Brass Threaded Adaptor , S&F Female Brass Threaded Adaptor (FTA/FBTA) 25mm bore (As per PDF file attach with BOQ)
40
-
-
0 mm outer dia Brass Tee , Supply and fixing 20 mm outer dia Brass Tee (As per PDF file attach with BOQ)
25
-
-
25 mm outer dia tank Adaptor , Supply and fixing 25 mm outer dia tank Adaptor (As per PDF file attach with BOQ)
20
-
-
20mm outer dia union , Supply and fixing 20mm outer dia union (As per PDF file attach with BOQ)
15
-
-
20mm outer dia union 2 , Supply and fixing 20mm outer dia union (As per PDF file attach with BOQ)
18
-
-
32 mm Brass Elbow , S&F 32 mm Brass Elbow (As per PDF file attach with BOQ)
25
-
-
40 mm Brass Elbow , S&F 40 mm Brass Elbow (As per PDF file attach with BOQ)
15
-
-
Male Brass Threaded Adaptor , S&F Male Brass Threaded Adaptor (MTA/MBTA) 32mm bore (As per PDF file attach with BOQ)
14
-
-
Male Brass Threaded Adaptor , S&F Male Brass Threaded Adaptor (MTA/MBTA) 40mm bore (As per PDF file attach with BOQ)
15
-
-
Female Brass Threaded Adaptor , S&F Female Brass Threaded Adaptor (FTA/FBTA) 32mm bore (As per PDF file attach with BOQ)
22
-
-
Female Brass Threaded Adaptor , S&F Female Brass Threaded Adaptor (FTA/FBTA) 40mm bore (As per PDF file attach with BOQ)
24
-
-
wall panels and hermatically sealed doors , Ascertain of discoloration on wall panels and hermatically sealed doors , sample to be collected from affected area in Mdular OT and testing to be done IN NABL Accredited lab and report to be submitted.
4
-
-
modular OT , Cleaning of modular OT for discoloration or any foreign element patches and making good to its original state including disinfection. Note To be done as per report through item 24.
4
-
-
Evaluation Notes How It Works ?
Potential Partner