Directorate Of RD PRIS And ULBS Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Directorate Of RD PRIS And ULBS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date28 Feb 2024
Closing Date7 Mar 2024
Tender Amount₹ 12,74,267
Costs
EMD
₹ 25,485Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RDPRI_13687_1Bid Award Id
ViewTender No
117/EE/PRI/MB/23-2024Tender Authority
Directorate Of RD PRIS And ULBS ViewPurchaser Address
-Website
http://eprocure.andaman.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and fixing form work and shuttering to receive the micro concrete including cost of all materials all labour charges, minor tools etc.
11.27
-
-
Supplying, mixing and applying curing membrane or equivalent with water including cost of all materials all labour charges, minor tools etc. complete.
11.27
-
-
Supplying and applying high strength non shrink cementinous free flow concrete ( eith minimum 28 days flexural strength 50kg/sq.cm and compressive strength 500 kg/sq.cm as per BIS 4551-80) for above water level on site to enable completion of pouring in a continous operation. An approved grout concrete mixture of slow speed heavy duty drill and exact quantity of water as recommended should be poured into the vessel slowly and mix the same throughly in a forced action. The mix materials should be placed immediately to position foam work continously to an average thockness of 50mm without any gap including all materials and labour charges etc. complete.
19.84
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
-
-
-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1.55
-
-
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
85.51
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
-
-
-
Of area 3 sq. metres and below
5
-
-
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
-
-
-
Asbestos Cement sheet
148
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources).
4.51
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, if nishing and reinforcement- All work up to plinth level :
-
-
-
1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
2.83
-
-
Centering and shuttering including strutting, propping etc. and removal of form for
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
8.77
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more
259.84
-
-
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
-
-
-
Superiour Hard wood cat-II(B)
0.15
-
-
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)
-
-
-
Superiour Hard wood Cat-II (B)
8.84
-
-
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :
-
-
-
Superiour Hard wood cat-II(B)
2.08
-
-
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
-
-
-
250x16 mm
3
-
-
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
200x10 mm
6
-
-
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
125 mm
6
-
-
100 mm
6
-
-
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge.
5.2
-
-
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.
-
-
-
30 mm thick plain PVC door shutters
1.8
-
-
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
-
-
-
Medium shade pigment using 50% white cement 50% Grey cement
7.34
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
7.47
-
-
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).
-
-
-
6 mm thick Cement fiber board as per IS: 14862
85.51
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
148
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
-
-
-
Ridges plain (500 - 600mm)
14
-
-
12 mm cement plaster of mix :
-
-
-
1:4 (1 cement: 4 River sand)
71
-
-
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification.
-
-
-
Two or more coats on new work
180.78
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :
-
-
-
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
126.69
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work
53.28
-
-
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work
25
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
317.73
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
-
-
-
One or more coats on old work.
22.8
-
-
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge.
11
-
-
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
-
-
-
Kitchen sink without drain board
-
-
-
610x510 mm bowl depth 200 mm
1
-
-
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
215.02
-
-
Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge.
42
-
-
Providing and fixing in position eave or facia board with 12 mm thick non asbestos plain sheet of HILUX Board and 30 cm wide including nailing etc. Complete as per the direction of Engineer-in-charge.
60.7
-
-
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
-
-
-
G.I. pipes
36.72
-
-
Electrical Works
-
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with piano type switch, suitable size PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
-
-
-
Group C
32
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit, alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
95
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC Conduit as required
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
180
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
30
-
-
Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells.
6
-
-
Supplying and fixing Suitable PVC box on surface or in recess, including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.Make anchor/Polycab/Havells.
5
-
-
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden
block including connection etc as required
28
-
-
Supplying of prewired LED tube light 20W LUMEN output 2000lm 6500K Product code PANASONIC PBTM02203 or equivalent to ISI standard.(Havells/Panasonic/Polycab) or Equivalent to ISI Standarad.
17
-
-
Installation, testing and commissioning of pre-wired, LED FITING of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
17
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB /Isolator)
-
-
-
6way Double door
1
-
-
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40 Amps, 2 Pole Isolator
1
-
-
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single Pole MCB
5
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
1
-
-
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
3
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthingas required.
25
-
-
Supplying and fixing of endura rugby Energy saving new generation Bulk head luminair opel defuses 10W LED 600K similar to havells Cat No. LHEOAOP7WZ6W010 or equivalent to ISI standard).
3
-
-
Supplying of A.C. Ceiling fan (1200mm sweep Energy efficient FAN) USHA ENERGIA 50W suitable for operation on 230 Volts, single Phase, 50Hz, A.C Supply including 300mm long rod and without regulator as required. (Make: Bajaj/ Usha/ Orient/Crompton or equivalent to ISI standard).
7
-
-
Supplying and fixing stepped type electronic fan regulator (Shocket type)on the switch box including connections etc. as required.Make : anchor/polycab/havells etc or equvalent to ISI standard.
7
-
-
Installation, testing and commissioning of ceiling fan, including down road and wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
7
-
-
Supplying and fixing of new generation energy saving enviroment friendly long life 25 W LED street light made up of pressure dia cast aluminium housing with high power LED as light source and embeded PC cover having top opening seprate driver compertment with IP65 PROTECTION AND ik07 IMPACET RESISTENCE (MAKE : Polycab CAT No.PUBO506109 ) along with its Mountning (GI PIPE 32mm) (Make: Bajaj /Havells /Orient/Crompton or equivalent to ISI standard).
2
-
-
Supplying of Exhaust fan (300 mm sweep, 900 rpm) Single phase with all accessories etc as required. Similar to Havells, Bajaj or equivalent to ISI Standard.
1
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
1
-
-
Extra for fixing the louvers/ shutters complete with FRLSame for a exhaust fan of all sizes.
1
-
-
Supplying and fixing brass batten/ angle holder including connection etc. as required.
2
-
-
Supplying of LED Lamp 9W (MAKE : WIPRO TEJAS 9W ) (Make: Bajaj/ Havells /Usha /Orient/Crompton or equivalent to ISI standard).
2
-
-
Supplying and fixing rewirable porceline with fuse unit of 32 to 40 amps on energy meter board.
1
-
-
Supplying ,Tesing and commissioning of clamp type hook in 40mm Dia Truss Pipe for installation of high bay lights etc as required.
7
-
-
Providing and fixing wooden board of size 10'' x 12'' for fixing of energy meter ectc. as required.
1
-
-