Directorate Of RD PRIS And ULBS Tender

To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.

Directorate Of RD PRIS And ULBS Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date6 Feb 2024
Closing Date19 Feb 2024
Tender Amount₹ 30,84,958 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)

7.53

-

-

... More
1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size).

3.3

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.

1373.33

-

-

... More
Centring and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete.

60.1

-

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

69.3

-

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

20

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :

-

-

-

... More
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size).

10.26

-

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5coarse sand : 3 graded stone aggregate 20 mm nominal size).

1.41

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :

-

-

-

... More
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).

1.25

-

-

... More
Providing and fixing up to floor five level precast cement concrete hollow block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete.

-

-

-

... More
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

20.72

-

-

... More
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.

-

-

-

... More
40 mm thick with 20 mm nominal size stone aggregate

28

-

-

... More
Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete.

5.25

-

-

... More
12 mm cement plaster of mix :

-

-

-

... More
1:4 (1 cement: 4 fine sand)

189.1

-

-

... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.

-

-

-

... More
Electric resistance or induction butt welded tubes

2315.29

-

-

... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

679.51

-

-

... More
Providing and fixing bolts including nuts and washers complete.

43.58

-

-

... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.

-

-

-

... More
G.I. pipes

110.04

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

206.5

-

-

... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :

-

-

-

... More
Ridges plain (500 - 600mm)

21

-

-

... More
Extra for providing and fixing wind ties of 40x 6 mm flat iron section.

84

-

-

... More
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Two or more coats on new work

59.46

-

-

... More
Providing and fixing in position eaves or facia board with 12 mm thick non asbestos plain sheet of HILUX Board and 30 cm wide including nailing etc complete as per the direction of Engineer - in - charge.

61.2

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.

-

-

-

... More
Two or more coats on new work

85.2

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

94.9

-

-

... More
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in- charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).

64.8

-

-

... More
Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately).

-

-

-

... More
6 mm thick Cement fiber board as per IS: 14862

28

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

31.9

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.

-

-

-

... More
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

5.52

-

-

... More
Wiring for Light Point /Fan Point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.

-

-

-

... More
Group -C

55

-

-

... More
Wiring for Light / Power Plug with 2 x 4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 no 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.

18

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
2 x 2.5 sq.mm + 1x 2.5 sq.mm earth wire

41.5

-

-

... More
1 x 6 sq.mm + 2 x 6 sq.mm earth wire

16

-

-

... More
Supplying and Fixing PVC box of 150mmX75mmX60mm (norminal size)on surface or in recess with suitable size of phenoilc lamination sheet cover in front including providing and fixing 3 pin 5/6 A Socket outlet and 5/6 A Piano type switch connection painting etc as required.

6

-

-

... More
Supplying and fixing Two Module type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

16

-

-

... More
Supplying and fixing PVC box of size 180 mm x100mm x60 mm deep (nominal size)on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps piano type switch connection painting etc .as required.

3

-

-

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

38

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)

-

-

-

... More
12 way, Double door

1

-

-

... More
Supplying and Installation of LED light similar to Havells COMET Surface LED Fitting, Lamp type 18W, Ordering code: LHEAAWP5IL1W018 Ultra modern slim surface mounted square LED panel al. die cast body which provides soft light and glare free symmetrical illumination suitable as required. Make: Havells or Equivalent to ISI Standard.

12

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 140/415 volts,"C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required.

-

-

-

... More
Single pole

10

-

-

... More
Supplying and fixing following rating, Double pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required.

-

-

-

... More
63 amps

1

-

-

... More
Earthing with Copper Earth Plate 600mm x 600mm x 3mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metres long etc. with charcoal, coke and salt as required.

1

-

-

... More
Providing and fixing 25mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring washer excavation and refilling etc. as required.

2

-

-

... More
Providing and fixing 25mm x 5 mm copper strip on on surface or in recess for connections as required.

18.5

-

-

... More
Supplying and installation of ceiling fan (1200 mm sweep),i/c wiring the down rods of standard length (upto 30cm) with 1.5sq.mm FRLS PVC insulated, copper conductor, single core cable etc. as required .Make: Crompton or equivalent to ISI standard.

16

-

-

... More
Supplying and Installation of 10W LED Bulk head wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. Make Bajaj or equivalent to ISI standard.

12

-

-

... More
Supplying and installation of 20 w LED tube light fitting/ fluorescent tube fitting/ compact fluorescent fitting of all type complete with all accessories and tube etc.directly on ceiling/ wall,i/c connection with 1.5sq mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required .Make: Havells CAT No. LHEXBXPNIN1W020 or equivalent to ISI standard.

15

-

-

... More
Providing and fixing wooden Board of size 10" X 12" for fixing of energy meter etc. as required.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.