Directorate Of RD PRIS And ULBS Tender
... More
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Directorate Of RD PRIS And ULBS Tender
Civil And Construction
Building Construction
Eprocure
Opening Date5 Jan 2024
Closing Date18 Jan 2024
Tender Amount₹ 19,47,350
Costs
EMD
₹ 38,947Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_RDPRI_12911_1Bid Award Id
ViewTender No
99/EE/PRI/MB/23-2024Tender Authority
Directorate Of RD PRIS And ULBS ViewPurchaser Address
-Website
http://eprocure.andaman.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
... More
1:4:8 (1 Cement : 4 Pulverised sand (zone-III) derived from natura sources : 8 graded stone aggregate 40 mm nominal size derived from natura sources)
8.33
-
-
... More
1:3:6 (1 Cement : 3 Pulverised sand (zone-III) derived from natura sources : 6 graded stone aggregate 40 mm nominal size derived from natura sources)
5.08
-
-
... More
1:2:4 (1 Cement : 2 Pulverised sand (zone-III) derived from natura sources : 4 graded stone aggregate 20 mm nominal size derived from natura sources)
0.59
-
-
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
... More
1:1.5:3 (1 cement : 1.5 Pulverised sand (zone-III) derived from natura sources: 3 graded stone aggregate 20 mm nominal size derived from natura sources).
7.3
-
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
... More
Thermo-Mechanically Treated bars of grade Fe-500D or more.
2038.18
-
-
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement
-
-
-
... More
1:1.5:3 (1 cement : 1.5 Pulverised sand (zone-III) derived from natura sources: 3 graded stone aggregate 20 mm nominal size derived from natura sources).
3.05
-
-
... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III)derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
4.14
-
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for:
-
-
-
... More
Foundations, footings, bases of columns, etc. for mass concrete
75.62
-
-
... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers
72.69
-
-
... More
Columns, Pillars, Piers, Abutments, Posts and Struts
48.85
-
-
... More
Providing and laying Hollow cement concrete block walling 200mm thick consisting of hollow block of size 400x200x200 mm of mix 1:3:6 (1 Cement : 3 Pulverised sand (zone-III) : 6 graded stone aggregate 40 mm nominal size) laid in cement martar 1:6 (1 Cement :6 Sand).
15.98
-
-
... More
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.
-
-
-
... More
G.I. pipes
237.18
-
-
... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
-
-
-
... More
Fixed to openings /wooden frames with rawl plugs screws etc.
388.2
-
-
... More
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
461.36
-
-
... More
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
-
-
-
... More
Electric resistance or induction butt welded tubes
551.23
-
-
... More
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
50.86
-
-
... More
Providing and fixing bolts including nuts and washers complete.
28.56
-
-
... More
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mmhick stone aggregate 40 mm nominal size, well rammed and consolidated and grouted with Pulverised including finishing the top smooth.
15
-
-
... More
Providing cement concrete surface drain i/c earth work excavation, 10cm thick baseconcrete and 15cm thick side walling with 1:3:6 (1 Cement : 3 sand : 6 graded stone aggregate 40 mm nominal size ) finishing with 12mm thick cement plaster 23x23cm surface drain.
36
-
-
... More
Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
80.52
-
-
... More
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
-
-
-
... More
Ridges plain (500 - 600mm)
12.5
-
-
... More
12 mm Cement Plaster of mix:
-
-
-
... More
1:4 (1 Cement :4 River Sand)
411.35
-
-
... More
White washing with lime to give an even shade :
-
-
-
... More
New work (three or more coats)
411.35
-
-
... More
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :
-
-
-
... More
New work (two or more coats) over and including water thinnable priming coat with cement primer
150.9
-
-
... More
Finishing walls with water proofing cement paint of required shade :
-
-
-
... More
New work (Two or more coats applied @ 3.84 kg/10 sqm)
84.31
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
... More
Two or more coats on new work
103.85
-
-
... More
Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :
-
-
-
... More
Two or more coats on new work
178.07
-
-
... More
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
-
-
-
... More
0.63 mm thick with zinc coating not less than 275 gm/m²
24.4
-
-
... More
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge
-
-
-
... More
Extruded section profile size 42x50 mm
5.4
-
-
... More
25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places
2.52
-
-
... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
-
-
-
... More
110 mm
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements